Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
NPJ Prim Care Respir Med ; 34(1): 23, 2024 Aug 20.
Article in English | MEDLINE | ID: mdl-39164292

ABSTRACT

Electronic inhalers provide information about patterns of routine inhaler use. During a 12-week study, 360 asthma patients using albuterol Digihaler generated 53,083 inhaler events that were retrospectively analyzed. A total of 41,528 (78%) of the recorded inhalation events were suitable for flow analysis (having a PIF ≥ 18 L/min and <120 L/min). Median PIF, inhalation volume, inhalation duration, and time to PIF for these events steadily decreased between the first and last 10 days of the study, by 5.1%, 12.6%, 15.9%, and 6.4%, respectively. Continuous short-acting beta2-agonist (SABA) overuse, defined as ≥2 SABA inhalations/week throughout the study period, was seen in 29% (n = 104) of patients. Of 260 patients with ≥1 instance of acute short-term SABA overuse, 55 (21%) had a confirmed exacerbation. Electronic recording of real-life inhaler use can capture valuable, objective information that could inform disease management and clinical decision-making.


Subject(s)
Asthma , Nebulizers and Vaporizers , Humans , Asthma/drug therapy , Male , Female , Retrospective Studies , Middle Aged , Adult , Administration, Inhalation , Albuterol/administration & dosage , Albuterol/therapeutic use , Bronchodilator Agents/administration & dosage , Bronchodilator Agents/therapeutic use , Aged , Young Adult , Adrenergic beta-2 Receptor Agonists/administration & dosage , Adrenergic beta-2 Receptor Agonists/therapeutic use , Adolescent
2.
NPJ Prim Care Respir Med ; 34(1): 13, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38806496

ABSTRACT

The Test of Adherence to Inhalers (TAI) Toolkit links an adherence measurement instrument (the TAI) to proven effective interventions for different causes of non-adherence to inhaled medication. This study aimed to assess the usability and feasibility of the TAI Toolkit in clinical practice. The TAI Toolkit was piloted in eight primary and secondary care settings. Each study site included 10 patients with asthma and/or COPD and suspected non-adherence. Healthcare professionals (HCPs) recorded clinical data and TAI Toolkit outcomes. Data on usability and feasibility were collected in semi-structured interviews and with the System Usability Score (SUS). Of the included patients, 81% were non-adherent, and sporadic non-adherence was the most common (69%). The TAI Toolkit was valued with a mean SUS-score of 85.9 by the HCPs. They found the toolkit to 'be visually attractive', 'easy-to-use' and 'give insight into patients' adherence', thereby offering good potential for its use in clinical practice.


Subject(s)
Asthma , Feasibility Studies , Medication Adherence , Nebulizers and Vaporizers , Pulmonary Disease, Chronic Obstructive , Humans , Medication Adherence/statistics & numerical data , Male , Pulmonary Disease, Chronic Obstructive/drug therapy , Female , Middle Aged , Asthma/drug therapy , Administration, Inhalation , Aged , Adult
3.
Adv Ther ; 41(6): 2151-2167, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38664329

ABSTRACT

Chronic obstructive pulmonary disease (COPD) constitutes a major global health burden and is the third leading cause of death worldwide. A high proportion of patients with COPD have cardiovascular disease, but there is also evidence that COPD is a risk factor for adverse outcomes in cardiovascular disease. Patients with COPD frequently die of respiratory and cardiovascular causes, yet the identification and management of cardiopulmonary risk remain suboptimal owing to limited awareness and clinical intervention. Acute exacerbations punctuate the progression of COPD in many patients, reducing lung function and increasing the risk of subsequent exacerbations and cardiovascular events that may lead to early death. This narrative review defines and summarises the principles of COPD-associated cardiopulmonary risk, and examines respiratory interventions currently available to modify this risk, as well as providing expert opinion on future approaches to addressing cardiopulmonary risk.


Subject(s)
Cardiovascular Diseases , Pulmonary Disease, Chronic Obstructive , Pulmonary Disease, Chronic Obstructive/complications , Pulmonary Disease, Chronic Obstructive/therapy , Humans , Cardiovascular Diseases/prevention & control , Cardiovascular Diseases/etiology , Disease Progression , Risk Factors , Heart Disease Risk Factors
5.
BMJ Open Respir Res ; 10(1)2023 12 22.
Article in English | MEDLINE | ID: mdl-38135462

ABSTRACT

BACKGROUND: Patients with chronic obstructive pulmonary disease (COPD) may be prescribed multiple inhalers that require different techniques for optimal performance. Mixing devices has been associated with poorer COPD outcomes suggesting that it leads to inappropriate inhaler technique. However, empirical evidence is lacking. AIMS: Compare the nature and frequency of dry powder inhaler (DPI) technique errors in patients with COPD using (1) a single DPI or (2) mixed-devices (a DPI and pressurised metered dose inhaler (pMDI)). METHODS: Data from the PIFotal study-a cross-sectional study on Peak Inspiratory Flow in patients with COPD using a DPI as maintenance therapy, capturing data from 1434 patients on demographic characteristics, COPD health status and inhaler technique-were used to select 291 patients using mixed-devices. Frequency matching based on country of residence and DPI device type was used to select 291 patients using a DPI-only for comparison. Predetermined checklists were used for the evaluation of DPI video recordings and complemented with additional errors that were observed in ≥10%. Error proportions were calculated for the (1) individual and total number of errors, (2) number of critical errors and (3) number of pMDI-related errors. RESULTS: The study sample contained 582 patients (mean (SD) age 69.6 (9.4) years, 47.1% female). DPI technique errors were common, but not significantly different between the groups. The majority of patients made at least one critical error (DPI-only: 90.7% vs mixed-devices: 92.8%). Proportions of total, 'pMDI-related' and critical errors did not significantly differ between the groups. CONCLUSION: The nature and frequency of inhaler technique errors did not substantially differ between patients prescribed with a single DPI and mixed-devices. Currently, 'pMDI-related errors' in DPI use are not accounted for in existing checklists. TRIAL REGISTRATION NUMBER: ENCEPP/EUPAS48776.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Humans , Female , Aged , Male , Cross-Sectional Studies , Metered Dose Inhalers/adverse effects , Administration, Inhalation , Dry Powder Inhalers
SELECTION OF CITATIONS
SEARCH DETAIL