Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 413
Filter
1.
Eur Heart J ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747561

ABSTRACT

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

3.
Article in English | MEDLINE | ID: mdl-38693866

ABSTRACT

AIMS: Evaluation of left and right ventricular longitudinal systolic function may enhance risk stratification following aortic valve replacement (AVR). The study objective was to evaluate the changes in left and right ventricular longitudinal systolic function and RV-pulmonary artery (RV-PA) coupling from baseline to 30-days and 1-year after aortic valve replacement (AVR). METHODS AND RESULTS: LV longitudinal strain (LS), tricuspid annulus plane systolic excursion (TAPSE), and RV-PA coupling were evaluated in patients from the PARTNER-2A surgical AVR (SAVR) arm (n=985) and from the PARTNER-2 SAPIEN-3 registry (n=719). TAPSE and RV-PA coupling decreased significantly following SAVR, but remained stable following TAVR. Lower LV LS, TAPSE, or RV-PA coupling at baseline were associated with increased risk of the composite of death, hospitalization, and stroke at 5-years (Adjusted-HRs for LV LS<15%: 1.24 95%CI 1.05-1.45, p=0.001; TAPSE<14mm: 1.44 95%CI 1.21-1.73, p<0.001; RV/PA coupling<0.55mm/mmHg: 1.32 95% CI 1.07-1.63, p=0.011). Reduced TAPSE at baseline was the most powerful predictor of the composite endpoint at 5-years. Patients with LV ejection fraction <50% at baseline had increased risk of the primary endpoint with SAVR (HR: 1.34, 95%CI 1.08-1.68, p=0.009) but not with TAVR (HR: 1.12, 95%CI 0.88-1.42). Lower RV-PA coupling at 30-days showed the strongest association with cardiac mortality. CONCLUSION: SAVR but not TAVR was associated with a marked deterioration in RV longitudinal systolic function and RV-PA coupling. Lower TAPSE and RV-PA coupling at 30-days were associated with inferior clinical outcomes at 5-years. In patients with LVEF<50%, TAVR was associated with superior 5-year outcomes.

4.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38749619

ABSTRACT

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/adverse effects , Severity of Illness Index
5.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599690

ABSTRACT

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Cardiac Catheterization/methods
6.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38552656

ABSTRACT

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Adolescent , Adult , Aged , Female , Humans , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Prospective Studies , Prosthesis Design , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
7.
JACC Cardiovasc Interv ; 17(3): 391-401, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38355267

ABSTRACT

BACKGROUND: Although permanent pacemaker (PPM) implantation is a common complication of transcatheter aortic valve replacement (TAVR), hospital variation and change in PPM implantation rates are ill defined. OBJECTIVES: The aim of this study was to determine hospital-level variation and temporal trends in the rate of PPM implantation following TAVR. METHODS: Using the American College of Cardiology/Society of Thoracic Surgeons TVT (Transcatheter Valve Therapy) Registry, temporal changes in variation of in-hospital and 30-day PPM implantation were determined among 184,452 TAVR procedures across 653 sites performed from 2016 to 2020. The variation in PPM implantation adjusted for valve type by annualized TAVR volume was determined, and characteristics of sites below, within, and above the 95% boundary were identified. A series of stepwise multivariable hierarchical models were then fit, and the median OR was used to measure variation in pacemaker rates among sites. RESULTS: From 2016 to 2020, the overall rate of PPM implantation was 11.3%, with wide variation across sites (range: 0%-36.4%); rates trended lower over time. Adjusted for annualized volume, there were 34 sites with PPM implantation rates above the 95th percentile CI and 28 with rates below, with wide variation among the remaining sites. After adjusting for patient-level covariates, there was variation among sites in the probability of PPM implantation (median OR: 1.39; 95% CI: 1.35-1.43, P < 0.001); although some of the variation was explained by the addition of valve type, residual variation in PPM implantation rates persisted in additional models incorporating site-level covariates (annualized volume, region, teaching status, hospital beds, etc). CONCLUSIONS: Although PPM implantation rates have decreased over time, substantial site-level variation remains even after accounting for observed patient characteristics and site-level factors. As there are numerous outlier sites both above and below the 95% confidence limit, dissemination of best practices from high-performing sites to low-performing sites and guideline-based education may be important quality improvement initiatives to reduce rates of this common complication.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors , Registries , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
8.
Ann Thorac Surg ; 2024 Feb 03.
Article in English | MEDLINE | ID: mdl-38316377

ABSTRACT

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.

9.
Am J Med ; 137(4): 321-330.e7, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38190959

ABSTRACT

PURPOSE: There are concerns that transcatheter or surgical aortic valve replacement (TAVR/SAVR) procedures are preferentially available to White patients. Our objective was to examine differences in utilization of aortic valve replacement and outcomes by race/ethnicity in the US for patients with aortic stenosis. METHODS: We performed a serial cross-sectional cohort study of 299,976 Medicare beneficiaries hospitalized with principal diagnosis of aortic stenosis between 2012 and 2019 stratified by self-reported race/ethnicity (Black, Hispanic, Asian, Native American, and White). Outcomes included aortic valve replacement rates within 6 months of index hospitalization and associated procedural outcomes, including 30-day readmission, 30-day and 1-year mortality. RESULTS: Within 6 months of an index admission for aortic stenosis, 86.8% (122,457 SAVR; 138,026 TAVR) patients underwent aortic valve replacement. Overall, compared with White people, Black (HR 0.87 [0.85-0.89]), Hispanic (0.92 [0.88-0.96]), and Asian (0.95 [0.91-0.99]) people were less likely to receive aortic valve replacement. Among patients who were admitted emergently/urgently, White patients (41.1%, 95% CI, 40.7-41.4) had a significantly higher aortic valve replacement rate compared with Black (29.6%, 95% CI, 28.3-30.9), Hispanic (36.6%, 95% CI, 34.0-39.3), and Asian patients (35.4%, 95% CI, 32.3-38.9). Aortic valve replacement rates increased annually for all race/ethnicities. There were no significant differences in 30-day or 1-year mortality by race/ethnicity. CONCLUSIONS: Aortic valve replacement rates within 6 months of aortic stenosis admission are lower for Black, Hispanic, and Asian people compared to White people. These race-related differences in aortic stenosis treatment reflect complex issues in diagnosis and management, warranting a comprehensive reassessment of the entire care spectrum for disadvantaged populations.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aged , United States/epidemiology , Aortic Valve/surgery , Cross-Sectional Studies , Medicare , Treatment Outcome , Aortic Valve Stenosis/surgery , Risk Factors
10.
Eur Heart J Open ; 4(1): oead124, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38174348

ABSTRACT

Aims: Aortic valve stenosis (AS) results in higher systolic pressure to overcome resistance from the stenotic valve, leading to heart failure and decline in cardiac output. There has been no assessment of cerebral blood flow (CBF) association with neurocognition in AS or the effects of valve replacement. The goal was to determine if AS is associated with altered cerebral haemodynamics and impaired neurocognition, and whether transcatheter aortic valve replacement (TAVR) improves haemodynamics and cognition. Methods and results: In 42 patients with planned TAVR, transcranial Doppler (TCD) assessed bilateral middle cerebral artery (MCA) mean flow velocities (MFVs); abnormality was <34.45 cm/s. The neurocognitive battery assessed memory, language, attention, visual-spatial skills, and executive function, yielding a composite Z-score. Impairment was <1.5 SDs below the normative mean. The mean age was 78 years, 59% Male, and the mean valve gradient was 46.87 mm/Hg. Mean follow-up was 36 days post-TAVR (range 27-55). Pre-TAVR, the mean MFV was 42.36 cm/s (SD = 10.17), and the mean cognitive Z-score was -0.22 SDs (range -1.99 to 1.08) below the normative mean. Among the 34 patients who returned after TAVR, the MFV was 41.59 cm/s (SD = 10.42), not different from baseline (P = 0.66, 2.28-3.67). Post-TAVR, average Z-scores were 0.17 SDs above the normative mean, not meeting the pre-specified threshold for a clinically significant 0.5 SD change. Conclusion: Among patients with severe AS, there was little impairment of MFV on TCD and no correlation with cognition. Transcatheter aortic valve replacement did not affect MFV or cognition. Assumptions about diminished CBF and improvement after TAVR were not supported.

11.
Struct Heart ; 8(1): 100225, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38283566

ABSTRACT

Background: Baseline left ventricular diastolic dysfunction (LVDD) is associated with poor health status in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR), but health status improvement after TAVR appears similar across all grades of LVDD. Here, we aim to examine the relationship between changes in LVDD severity and health status outcomes following TAVR. Methods: Patients who underwent TAVR and had evaluable LVDD at both baseline and 1 year in the PARTNER (Placement of Aortic Transcatheter Valves) 2 SAPIEN 3 registries and PARTNER 3 trial were analyzed. LVDD grade was evaluated using echocardiography core lab data and an adapted definition of American Society of Echocardiography guidelines. Health status was assessed using the Kansas City Cardiomyopathy Questionnaire Overall Summary (KCCQ-OS) score. The association between ΔLVDD severity and ΔKCCQ-OS was examined using linear regression models adjusted for baseline KCCQ-OS. Results: Of 1100 patients, 724 (65.8%), 283 (25.7%), and 93 (8.5%) had grade 0/1, 2, and 3 LVDD at baseline, respectively. At 1 year, LVDD severity was unchanged in 790 (71.8%) patients, improved in 189 (17.2%), and worsened in 121 (11.0%). Among 376 patients with baseline grade 2 or 3 LVDD, 50.3% had improvement in LVDD. In the overall cohort, KCCQ-OS score improved by 21.9 points at 1 year. There was a statistically significant association between change in LVDD severity (improved, unchanged, and worsened) and ΔKCCQ-OS at 1 year (p = 0.007). Conclusions: Change in LVDD grade was associated with change in health status 1 year following TAVR.

12.
Struct Heart ; 8(1): 100234, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38283574

ABSTRACT

In 2022, the Food and Drug Administration approved a second mitral transcatheter edge-to-edge repair device for the treatment of primary mitral regurgitation (PASCAL Precision Transcatheter Valve Repair System, Edwards Lifesciences, Irvine, CA). The PASCAL Precision system consists of a guide sheath, implant system, and accessories. The implant system consists of a steerable catheter, an implant catheter, and the implant (PASCAL or PASCAL Ace). The guide sheath and steerable catheter move and flex independently from each other and are not keyed, allowing for freedom of rotation in three dimensions. This manuscript provides an overview of the PASCAL Precision system and describes the basic and advanced steering maneuvers to facilitate effective and safe mitral transcatheter edge-to-edge repair.

13.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38096587

ABSTRACT

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Rheumatic Heart Disease , Tricuspid Valve Insufficiency , Humans , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/complications , Rheumatic Heart Disease/complications , Retrospective Studies
14.
JACC Cardiovasc Imaging ; 17(1): 79-95, 2024 01.
Article in English | MEDLINE | ID: mdl-37731368

ABSTRACT

Tricuspid regurgitation (TR) is a highly prevalent and heterogeneous valvular disease, independently associated with excess mortality and high morbidity in all clinical contexts. TR is profoundly undertreated by surgery and is often discovered late in patients presenting with right-sided heart failure. To address the issue of undertreatment and poor clinical outcomes without intervention, numerous structural tricuspid interventional devices have been and are in development, a challenging process due to the unique anatomic and physiological characteristics of the tricuspid valve, and warranting well-designed clinical trials. The path from routine practice TR detection to appropriate TR evaluation, to conduction of clinical trials, to enriched therapeutic possibilities for improving TR access to treatment and outcomes in routine practice is complex. Therefore, this paper summarizes the key points and methods crucial to TR detection, quantitation, categorization, risk-scoring, intervention-monitoring, and outcomes evaluation, particularly of right-sided function, and to clinical trial development and conduct, for both interventional and surgical groups.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Diagnostic Imaging , Predictive Value of Tests , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Clinical Trials as Topic
15.
Catheter Cardiovasc Interv ; 103(2): 367-375, 2024 02.
Article in English | MEDLINE | ID: mdl-37890014

ABSTRACT

AIMS: Characterize the impact of residual tricuspid regurgitation (TR) on right ventricle (RV) remodeling and clinical outcomes after transcatheter tricuspid valve intervention. METHODS: We performed a single-center retrospective analysis of transcatheter tricuspid valve repair (TTVr) or replacement (TTVR) patients. The primary outcomes were longitudinal tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), pulmonary artery systolic pressure (PASP), and RV dimensions (RVd). We used multivariable linear mixed models to evaluate association with replacement versus repair and degree of TR reduction with changes in these echo measures over time. Multivariable Cox regression was used to identify associations between changes in these echo measures and a composite clinical outcome of death, heart failure hospitalization, or re-do tricuspid valve intervention. RESULTS: We included a total of 61 patients; mean age was 77.5 ± 11.7 and 62% were female. TTVR was performed in 25 (41%) and TTVr in 36 (59%). Initially, 72% (n = 44) had ≤ severe TR and 28% (n = 17) had massive or torrential TR. The median number of follow up echos was 2: time to 1st follow-up was 50 days (interquartile range [IQR]: 20, 91) and last follow-up was 147 (IQR: 90, 327). Median TR reduction was 1 (IQR: 0, 2) versus 4 (IQR: 3, 6) grades in TTVr versus TTVR (p < 0.0001). In linear mixed modeling, TTVR was associated with decline in TAPSE and PASP, and TR reduction was associated with decreased RVd. In multivariable Cox regression, greater RVd was associated with the clinical outcome (hazard ratio: 9.27, 95% confidence interval: 1.23-69.88, p = 0.03). CONCLUSION: Greater TR reduction is achieved by TTVR versus TTVr, which is in turn associated with RV reverse remodeling. RV dimension in follow-up is associated with increased risk of a composite outcome of death, heart failure hospitalization, or re-do tricuspid valve intervention.


Subject(s)
Heart Failure , Tricuspid Valve Insufficiency , Humans , Female , Aged , Aged, 80 and over , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Retrospective Studies , Ventricular Remodeling , Treatment Outcome , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/complications , Heart Failure/diagnostic imaging , Heart Failure/therapy
17.
Article in English | MEDLINE | ID: mdl-37962288

ABSTRACT

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

18.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Article in English | MEDLINE | ID: mdl-37930776

ABSTRACT

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Aged , Male , Tricuspid Valve Insufficiency/epidemiology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Prospective Studies , Quality of Life , Treatment Outcome , Cardiac Catheterization/methods , Severity of Illness Index
19.
JACC Cardiovasc Interv ; 16(23): 2868-2879, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37902145

ABSTRACT

BACKGROUND: High surgical risk may preclude mitral valve replacement in many patients. Transcatheter mitral valve replacement (TMVR) using transfemoral transseptal access is a novel technology for the treatment of mitral regurgitation (MR) in high-risk surgical patients. OBJECTIVES: This analysis evaluates 30-day and 1-year outcomes of the Intrepid TMVR Early Feasibility Study in patients with ≥moderate-severe MR. METHODS: The Intrepid TMVR Early Feasibility Study is a multicenter, prospective, single-arm study. Clinical events were adjudicated by a clinical events committee; endpoints were defined according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 33 patients, enrolled at 9 U.S. sites between February 2020 and August 2022, were included. The median age was 80 years, 63.6% of patients were men, and mean Society of Thoracic Surgeons Predicted Risk of Mortality for mitral valve replacement was 5.3%. Thirty-one (93.9%) patients were successfully implanted. Median postprocedural hospitalization length of stay was 5 days, and 87.9% of patients were discharged to home. At 30 days, there were no deaths or strokes, 8 (24.2%) patients had major vascular complications and none required surgical intervention, there were 4 cases of venous thromboembolism all successfully treated without sequelae, and 1 patient had mitral valve reintervention for severe left ventricular outflow tract obstruction. At 1 year, the Kaplan-Meier all-cause mortality rate was 6.7%, echocardiography showed ≤mild valvular MR, there was no/trace paravalvular leak in all patients, median mitral valve mean gradient was 4.6 mm Hg (Q1-Q3: 3.9-5.3 mm Hg), and 91.7% of survivors were in NYHA functional class I/II with a median 11.4-point improvement in Kansas City Cardiomyopathy Questionnaire overall summary scores. CONCLUSIONS: The early benefits of the Intrepid transfemoral transseptal TMVR system were maintained up to 1 year with low mortality, low reintervention, and near complete elimination of MR, demonstrating a favorable safety profile and durable valve function.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Male , Humans , Aged, 80 and over , Female , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Feasibility Studies , Prospective Studies , Cardiac Catheterization/methods , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology
20.
JACC Cardiovasc Interv ; 16(23): 2820-2832, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37905772

ABSTRACT

BACKGROUND: Favorable 6-month outcomes from the CLASP IID Registry (Edwards PASCAL transcatheter valve repair system pivotal clinical trial) demonstrated that mitral valve transcatheter edge-to-edge repair with the PASCAL transcatheter valve repair system is safe and beneficial for treating prohibitive surgical risk degenerative mitral regurgitation (DMR) patients with complex mitral valve anatomy. OBJECTIVES: The authors sought to assess 1-year safety, echocardiographic and clinical outcomes from the CLASP IID Registry. METHODS: Patients with 3+ or 4+ DMR who were at prohibitive surgical risk, had complex mitral valve anatomy based on the MitraClip Instructions for Use, and deemed suitable for treatment with the PASCAL system were enrolled prospectively. Safety, clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. Study oversight included a central screening committee, echocardiographic core laboratory, and clinical events committee. RESULTS: Ninety-eight patients were enrolled. One-year Kaplan-Meier (KM) estimates of freedom from composite major adverse events, all-cause mortality, and heart failure hospitalization were 83.5%, 89.3%, and 91.5%, respectively. Significant mitral regurgitation (MR) reduction was achieved at 1 year (P < 0.001 vs baseline) including 93.2% at MR ≤2+ and 57.6% at MR ≤1+ with improvements in related echocardiographic measures. NYHA functional class and Kansas City Cardiomyopathy Questionnaire score also improved significantly (P < 0.001 vs baseline). CONCLUSIONS: At 1 year, treatment with the PASCAL system demonstrated safety and significant MR reduction, with continued improvement in clinical, echocardiographic, functional, and quality-of-life outcomes, illustrating the value of the PASCAL system in the treatment of prohibitive surgical risk patients with 3+ or 4+ DMR and complex mitral valve anatomy.


Subject(s)
Cardiac Catheterization , Mitral Valve Insufficiency , Humans , Cardiac Catheterization/adverse effects , Echocardiography , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Treatment Outcome , Clinical Trials as Topic
SELECTION OF CITATIONS
SEARCH DETAIL
...