Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Perfusion ; 34(6): 453-459, 2019 09.
Article in English | MEDLINE | ID: mdl-30736721

ABSTRACT

BACKGROUND: Venoarterial extracorporeal membrane oxygenation support is a well-established tool in the care of severe refractory cardiac and respiratory failure. The application of this support may serve as a bridge to transplant, recovery or to implantation of a ventricular assist device. Venoarterial extracorporeal membrane oxygenation support can be administered through an open surgical access via the common femoral or axillary artery or a percutaneous approach using Seldinger technique. Both techniques may obstruct the blood flow to the lower limb and may cause a significant ischemia with possible limb loss. Malperfusion of the distal limb can be avoided using an ipsilateral distal limb perfusion, which may be established by adding a single-lumen catheter during venoarterial extracorporeal membrane oxygenation treatment to overcome the obstruction. The aim of this study is to distinguish the presence or absence of a distal limb perfusion regarding the incidence of distal limb ischemia. Furthermore, expected risk factors of open and percutaneous femoral venoarterial extracorporeal membrane oxygenation installation were evaluated for the development of distal limb ischemia. METHODS: Between January 2012 and September 2015, 489 patients received venoarterial extracorporeal membrane oxygenation support at our institution. In total, 307 patients (204 male, 103 female) with femoral cannulation were included in the analysis. The cohort was distinguished by the presence (group A; n = 237) or absence (group B; n = 70) of a distal limb perfusion during peripheral venoarterial extracorporeal membrane oxygenation treatment. Furthermore, a risk factor analysis for the development of distal limb ischemia was performed. RESULTS: The main indications for venoarterial extracorporeal membrane oxygenation therapy were a low cardiac output syndrome (LCOS) (53%) and failed weaning of extracorporeal circulation (23%). A total of 23 patients (7.49%) under venoarterial extracorporeal membrane oxygenation support developed severe distal limb malperfusion (3.38% in group A vs 21.42% in group B). Preemptive installation of distal limb perfusion extended the intervention-free intervals to 7.8 ± 19.3 days in group A and 6.3 ± 12.5 in group B. A missing distal limb perfusion (p = 0.001) was identified as a main risk factor for critical limb ischemia. Other comorbidities such as arterial occlusion disease (p = 0.738) were not statistically significantly associated. Surgical intervention due to vascular complications after extracorporeal membrane oxygenation explantation was needed in 14 cases (4.22% in group A and 5.71% in group B). CONCLUSION: We were able to identify the absence of distal limb perfusion as an independent risk factor for the development of critical distal limb ischemia during femoral venoarterial extracorporeal membrane oxygenation treatment. The application of a distal limb perfusion should be considered as a mandatory approach in the context of femoral venoarterial extracorporeal membrane oxygenation treatment regardless of the implantation technique.


Subject(s)
Catheterization , Extracorporeal Membrane Oxygenation , Extremities/blood supply , Femoral Artery/surgery , Ischemia , Adult , Aged , Female , Humans , Ischemia/physiopathology , Ischemia/surgery , Male , Middle Aged , Retrospective Studies , Risk Factors
2.
Interact Cardiovasc Thorac Surg ; 22(6): 744-9, 2016 06.
Article in English | MEDLINE | ID: mdl-26920726

ABSTRACT

OBJECTIVES: Aortic valve replacement in patients with a small aortic annulus may result in patient-prosthesis mismatch (PPM). Aortic root enlargement (ARE) can reduce PPM, but leads to extended cardiac ischaemia times. Sutureless valves have the potential to prevent PPM while reducing cardiac ischaemia times. METHODS: Between January 2007 and December 2011, a total of 128 patients with a small aortic annulus underwent surgery for aortic valve stenosis at our centre. Thirty-six (17% male, n = 6) patients received conventional valve replacement with ARE and 92 (16% male, n = 18) subjects received sutureless valve implantation (Sorin Perceval). We conducted a comparative, retrospective study with follow-up. RESULTS: The sutureless group showed a significantly higher age (79 years) than the ARE patients (62 years, P < 0.001) and received significantly more concomitant cardiac procedures (33%, n = 30 vs 6%, n = 2, P = 0.001). The mean operation, cardiopulmonary bypass and cross-clamp times were significantly lower in sutureless patients (147 ± 42, 67 ± 26 and 35 ± 13 min, respectively) than in ARE patients (181 ± 41, 105 ± 29 and 70 ± 19 min, respectively, P < 0.001). The mean postoperative effective orifice area (EOA) indexed to the body surface area was 0.91 ± 0.2 cm(2)/m(2) in ARE patients and 0.83 ± 0.14 cm(2)/m(2) in sutureless patients (P = 0.040). The rate of patients with severe PPM was 6% (n = 2) in ARE patients and 11% (n = 8%) in sutureless patients (not significant, n.s.). The 30-day mortality rates were 2% (n = 2) in sutureless patients and 6% (n = 2) in ARE patients (n.s.). The 1- and 5-year survival rates of the sutureless group were 92 and 54% years, respectively, whereas the 1- and 5-year survival rates of the ARE group were 76% (n.s.). CONCLUSIONS: Although the sutureless valve patients received significantly more concomitant procedures, all operation-associated times were significantly shorter. Despite sutureless valve patients being older, the 30-day mortality and survival rates were comparable in the two groups. Since the indexed EOA was only slightly lower and the incidence of severe PPM was not significantly higher in the sutureless valve patients, we conclude that sutureless valve implantation is an alternative to conventional ARE to treat a small aortic annulus and avoid PPM, especially in geriatric patients who benefit from the quick implantation process.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Postoperative Complications/prevention & control , Suture Techniques , Adult , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnosis , Echocardiography, Doppler , Female , Humans , Male , Middle Aged , Operative Time , Prosthesis Design , Retrospective Studies , Survival Rate , Treatment Outcome
3.
J Heart Valve Dis ; 19(3): 286-91, 2010 May.
Article in English | MEDLINE | ID: mdl-20583390

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: Composite replacement is the standard treatment for the repair of aortic aneurysm with aortic valve pathology. With improved long-term durability and no requirement for long-term anticoagulation, tissue-valved conduits have become increasingly popular. Herein are reported the results achieved with 50 consecutive 'Bentall' operations, using the first commercially available prefabricated stentless tissue-valved conduit (Vascutek BioValsalva). METHODS: Between September 2007 and September 2009, a total of 50 patients (10 females, 40 males; mean age 65 +/- 7 years) received a BioValsalva conduit. Concomitant procedures included coronary artery bypass grafting (CABG; n = 15), other valve (n = 5), and aortic arch replacement with circulatory arrest (n = 20; three of these had an additional frozen elephant trunk). Four of the procedures were re-operations. A six-month follow up with echocardiography and clinical examination was completed in 25 patients. RESULTS: The 30-day mortality was 8% (4/50). Three of these patients underwent concomitant procedures. The cardiopulmonary bypass (CPB) and cross-clamp times were 178 +/- 30 min and 106 +/- 7 min, respectively. The triple-layered vascular graft proved to be hemostatic, without suture-line bleeding. Both, the initial and follow up echocardiography showed no valvular insufficiency, with a mean gradient of 13 +/- 5 mmHg. All patients were in NYHA class I-II. CONCLUSION: The BioValsalva prefabricated tissue-valved conduit showed very good early results. The ischemic time required to construct a 'home-made' stentless tissue-valved conduit was eliminated, thus reducing the cross-clamp time. The conduit also offered the hemodynamic advantages of a stentless valve.


Subject(s)
Aortic Aneurysm/surgery , Blood Vessel Prosthesis , Heart Valve Diseases/surgery , Heart Valve Prosthesis , Adult , Aged , Aged, 80 and over , Aortic Aneurysm/epidemiology , Blood Vessel Prosthesis Implantation , Comorbidity , Female , Heart Valve Diseases/epidemiology , Heart Valve Prosthesis Implantation , Humans , Male , Middle Aged , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL
...