1.
J ISAKOS ; 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38692433

ABSTRACT

OBJECTIVES: The purpose of this study was to define the rate of preoperative opioid use among patients undergoing hip arthroscopy, ascertain which clinical factors are associated with opioid use, and assess the effect of preoperative opioid usage on preoperative patient-reported outcome (PRO) measures. METHODS: A single institution orthopedic registry was retrospectively analyzed for patients undergoing hip arthroscopy for femoroacetabular impingement (FAI) syndrome with or without labral tear between 2015 and 2022. Patients completed Patient-Reported Outcomes Measurement Information System (PROMIS) in six domains, Numeric Pain Scores (NPS), and Musculoskeletal Outcomes Data Evaluation and Management System expectations domain preoperatively. Patients' charts were reviewed to determine demographic factors and identify any active opioid prescription within 6 weeks before surgery. Bivariate analysis was used to determine associations between preoperative opioid use and baseline PROs. Statistically significant bivariate associations were further tested by multivariate analysis to determine independent predictors. RESULTS: A total of 123 patients were included (age 39.7 â€‹± â€‹12.0 years; 87 females; body mass index 27.4 â€‹± â€‹5.7 kg/m2). There were 21 patients (17%) using opioids preoperatively. Prior orthopedic or other surgery and lower education level were associated with preoperative opioid use. Patients with preoperative opioid use scored statistically significantly worse compared with those without preoperative opioid use on baseline PROMIS Physical Function (38.6 vs 40.5, p â€‹= â€‹0.01), Pain Interference (65.9 vs 60.2, p â€‹= â€‹0.001), Fatigue (60.7 vs 51.6, p â€‹= â€‹0.005), Social Satisfaction (38.2 vs 43.2, p â€‹= â€‹0.007), and Depression (54.2 vs 48.8, p â€‹= â€‹0.01). Preoperative opioid use was also associated with statistically significantly worse preoperative NPS for both the operative hip (6.3 vs 4.6, p â€‹= â€‹0.003) and whole body (3.0 vs 1.4, p â€‹= â€‹0.008). Preoperative opioid use was an independent predictor of worse baseline PROMIS Pain Interference, Fatigue, Social Satisfaction, and NPS for the operative hip. CONCLUSION: Patients using opioids preoperatively had worse baseline PROs for physical function, pain, social satisfaction, and depression than those not using opioids preoperatively. When controlling for confounding variables, preoperative opioid use was independently predictive of worse baseline pain, fatigue, and social satisfaction. LEVEL OF EVIDENCE: Level III, prognostic study.

2.
J ISAKOS ; 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38556170

ABSTRACT

OBJECTIVES: The goal of this project was to develop and validate a patient-specific, anatomically correct graft for cartilage restoration using magnetic resonance imaging (MRI) data and 3-dimensional (3D) printing technology. The specific aim was to test the accuracy of a novel method for 3D printing and implanting individualized, anatomically shaped bio-scaffolds to treat cartilage defects in a human cadaveric model. We hypothesized that an individualized, anatomic 3D-printed scaffold designed from MRI data would provide a more optimal fill for a large cartilage defect compared to a generic flat scaffold. METHODS: Four focal cartilage defects (FCDs) were created in paired human cadaver knees, age <40 years, in the weight-bearing surfaces of the medial femoral condyle (MFC), lateral femoral condyle (LFC), patella, and trochlea of each knee. MRIs were obtained, anatomic grafts were designed and 3D printed for the left knee as an experimental group, and generic flat grafts for the right knee as a control group. Grafts were implanted into corresponding defects and fixed using tissue adhesive. Repeat post-implant MRIs were obtained. Graft step-off was measured as the distance in mm between the surface of the graft and the native cartilage surface in a direction perpendicular to the subchondral bone. Graft contour was measured as the gap between the undersurface of the graft and the subchondral bone in a direction perpendicular to the joint surface. RESULTS: Graft step-off was statistically significantly better for the anatomic grafts compared to the generic grafts in the MFC (0.0 â€‹± â€‹0.2 â€‹mm vs. 0.7 â€‹± â€‹0.5 â€‹mm, p â€‹< â€‹0.001), LFC (0.1 â€‹± â€‹0.3 â€‹mm vs. 1.0 â€‹± â€‹0.2 â€‹mm, p â€‹< â€‹0.001), patella (-0.2 â€‹± â€‹0.3 â€‹mm vs. -1.2 â€‹± â€‹0.4 â€‹mm, p â€‹< â€‹0.001), and trochlea (-0.4 â€‹± â€‹0.3 vs. 0.4 â€‹± â€‹0.7, p â€‹= â€‹0.003). Graft contour was statistically significantly better for the anatomic grafts in the LFC (0.0 â€‹± â€‹0.0 â€‹mm vs. 0.2 â€‹± â€‹0.4 â€‹mm, p â€‹= â€‹0.022) and trochlea (0.0 â€‹± â€‹0.0 â€‹mm vs. 1.4 â€‹± â€‹0.7 â€‹mm, p â€‹< â€‹0.001). The anatomic grafts had an observed maximum step-off of -0.9 â€‹mm and a maximum contour mismatch of 0.8 â€‹mm. CONCLUSION: This study validates a process designed to fabricate anatomically accurate cartilage grafts using MRI and 3D printing technology. Anatomic grafts demonstrated superior fit compared to generic flat grafts. LEVEL OF EVIDENCE: Level IV.

3.
Orthop J Sports Med ; 11(2): 23259671221146559, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36874054

ABSTRACT

Background: The pattern of glenoid bone loss (GBL) in anterior glenohumeral instability is well described. It was recognized recently that posterior GBL after instability has a posteroinferior pattern. Purpose/Hypothesis: The purpose of this study was to compare GBL patterns in a matched cohort of patients with anterior versus posterior glenohumeral instability. The hypothesis was that the GBL pattern in posterior instability would be more inferior than the GBL pattern in anterior instability. Study Design: Cohort study; Level of evidence, 3. Methods: In this multicenter retrospective study, 28 patients with posterior instability were matched with 28 patients with anterior instability by age, sex and number of instability events. GBL location was defined using a clockface model. Obliquity was defined as the angle between the long axis of the glenoid and a line tangent to the GBL. Superior and inferior GBL were measured as areas and defined relative to the equator. The primary outcome was the 2-dimensional characterization of posterior versus anterior GBL. The secondary outcome was a comparison of the posterior GBL patterns in traumatic and atraumatic instability mechanisms in an expanded cohort of 42 patients. Results: The mean age of the matched cohorts (n = 56) was 25.2 ± 9.87 years. The median obliquity of GBL was 27.53° (interquartile range [IQR], 18.83°-47.38°) in the posterior cohort and 9.28° (IQR, 6.68°-15.75°) in the anterior cohort (P < .001). The mean superior-to-inferior bone loss ratio was 0.48 ± 0.51 in the posterior cohort and 0.80 ± 0.55 (P = .032) in the anterior cohort. In the expanded posterior instability cohort (n = 42), patients with traumatic injury mechanism (n = 22), had a similar GBL obliquity compared to patients with an atraumatic injury mechanism (n = 20) (mean, 27.73° [95% CI, 20.26°-35.20°] vs 32.20° [95% CI, 21.27°-43.14°], respectively) (P = .49). Conclusion: Posterior GBL occurred more inferiorly and at an increased obliquity compared with anterior GBL. This pattern is consistent for traumatic and atraumatic posterior GBL. Bone loss along the equator may not be the most reliable predictor of posterior instability, and critical bone loss may be reached more rapidly than a model of loss along the equator may predict.

4.
HSS J ; 19(1): 69-76, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36776510

ABSTRACT

Background: The Epoch FullCoat Hip Stem (Zimmer) was an isoelastic composite femoral stem developed to address stem stiffness concerns. Purpose: We sought to evaluate the long-term bone mineral density (BMD) of a cohort of patients who underwent total hip arthroplasty (THA) using the Epoch isoelastic stem and having more than 2-decade follow-up. Methods: We conducted a retrospective chart review of all patients who were study subjects at our institution in a multicenter prospective trial for the Food and Drug Administration of the Epoch implant in the mid-1990s. Through this, we identified 16 patients who had dual-energy X-ray absorptiometry (DEXA) scans, with which we could determine BMD preoperatively and at 3 points postoperatively. Of these, 5 agreed to participate in the study (the others were deceased, unable or declined to participate, or were lost to follow-up) with mean follow-up of 22 years. These participants underwent clinical and radiographic evaluation consisting of a Harris hip score, anteroposterior (AP) pelvis and AP and lateral hip X-rays, and DEXA evaluation of both hips. BMD in the 7 Gruen zones at last follow-up was compared with immediate postoperative and 2-year follow-up. Results: At last follow-up, all stems were well-fixed with signs of extensive osteointegration. In proximal Gruen zones 1 and 7, patients underwent a decrease in BMD with more modest losses in Gruen zone 1. All patients demonstrated an increase in BMD in zones 2 through 6 at latest follow-up, except for 1 patient in Gruen zone 6. BMD changes were not limited to the first 2 years of follow-up. Conclusion: This small follow-up cohort study found excellent long-term clinical results, no plain radiographic signs of notable stress shielding, and general maintenance of BMD at a follow-up of over 20 years for this isoelastic stem. Long-term bone remodeling after implantation of the isoelastic stem resulted in increased BMD in Gruen zones 2 through 6, suggesting that composite implant designs may still have a role in THA.

5.
Knee Surg Sports Traumatol Arthrosc ; 30(10): 3563-3569, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35416491

ABSTRACT

PURPOSE: The purpose of this study was to analyze the correlation between baseline depression and anxiety and preoperative functional status in hip arthroscopy patients. METHODS: A prospective, institutional review board-approved orthopaedic registry was used to retrospectively study 104 patients undergoing hip arthroscopy. Enrolled patients were administered baseline questionnaires for Patient-Reported Outcomes Measurement Information System (PROMIS) domains, Musculoskeletal Outcomes Data Evaluation and Management System (MODEMS) preoperative expectations, and Numeric Pain Scale (NPS). RESULTS: The average baseline PROMIS Depression and Anxiety scores were 49.9 ± 9.8 and 55.5 ± 9.3, respectively. Bivariate analysis demonstrated that greater baseline PROMIS Anxiety correlated with worse preoperative PROMIS PI (p < 0.001), Fatigue (p < 0.001), Social Satisfaction (p < 0.001), and NPS score (p = 0.013). Bivariate analysis showed that greater PROMIS Depression correlated with worse preoperative PROMIS PF (p = 0.001), PI (p < 0.001), Fatigue (p < 0.001), SS (p < 0.001), and NPS score (p = 0.004). After controlling for confounders, multivariable analysis confirmed increased PROMIS Depression as an independent predictor of worse preoperative PROMIS PF (p = 0.009), MODEMS Expectations (p = 0.025), and NPS score (p = 0.002). Increased PROMIS Anxiety was predictive of worse baseline PROMIS PI (p < 0.001), Fatigue (p < 0.001), and Social Satisfaction (p < 0.001). A previous clinical diagnosis of depression or anxiety was only an independent predictor of worse baseline PROMIS Fatigue (p = 0.002) and was insignificant in all other models. CONCLUSION: Increasing severity of depression and anxiety correlated with and predicted worse functional status at baseline in hip arthroscopy patients. As compared to clinical diagnosis of anxiety and depression, PROMIS metrics have superior utility in recognizing potentially modifiable mental health concerns that predict worse preoperative status. Ultimately, the study identifies an at-risk population undergoing hip arthroscopy that requires particular attention and potential mental health intervention in the preoperative setting. LEVEL OF EVIDENCE: III.


Subject(s)
Arthroscopy , Depression , Anxiety/diagnosis , Depression/psychology , Fatigue , Humans , Patient Reported Outcome Measures , Prospective Studies , Retrospective Studies
6.
J Arthroplasty ; 37(6): 1130-1135, 2022 06.
Article in English | MEDLINE | ID: mdl-35131388

ABSTRACT

BACKGROUND: A uniquely designed, non-heat-treated moderately cross-linked acetabular polyethylene liner used in total hip arthroplasty (THA) demonstrated excessive wear during routine follow-up, prompting an evaluation of the linear wear rate. METHODS: All THAs were performed by the senior author. The study group included 38 THAs using the uniquely designed polyethylene in question, compared to a control group of 21 THAs using another moderately cross-linked polyethylene with good 10-year outcomes. Two-dimensional linear head penetration wear measurements were obtained using the Martell Hip Analysis Suite, and retrieval analysis was performed on two liners. RESULTS: The study group had a significantly higher average penetration rate of 0.089 mm/y than the control group average rate of 0.047 mm/y (P = .04). Forty-five percent of the study group had a wear rate above the osteolysis threshold (0.1 mm/y), compared to 24% in the control group. Macroscopic analysis of two retrieved liners validated the radiographic findings. CONCLUSION: The data suggest unexpectedly higher wear rates for a moderately cross-linked polyethylene design, with nearly half of the study group at risk for osteolysis. Further registry or database analyses of this particular moderately cross-linked polyethylene are warranted.