J Hypertens ; 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38690918

ABSTRACT

OBJECTIVE: A novel automated auscultatory upper-arm cuff blood pressure (BP) monitor for office use (KOROT P3 Accurate, previously InBody BPBIO480KV), which displays Korotkoff sound curves for each BP reading was recently developed. This study investigated whether the review of Korotkoff sound curves by healthcare professionals further improves the accuracy of the device by identifying unreliable BP readings. METHODS: Three observers assessed independently the morphology of Korotkoff sound curves of BP measurements obtained during an ISO 81060-2:2018 validation study, and classified them as of good, fair, or poor quality (low amplitude or sound intensity, aberrant morphology, background noise, signal artifact, auscultatory gap, irregular rhythm). The observers were blinded to the study BP measurements. RESULTS: Korotkoff sound curves of 255 BP readings obtained in 85 individuals were analyzed (mean age 57.3 ±â€Š15.0 years, 53 men). Of the SBP readings 80.4/12.2/7.4% were classified as good/fair/poor, and DBP 76.9/12.2/10.9%. Inter-observer agreement in detecting poor-quality curves was 84.7/83.1% (systolic/diastolic). Of poor-quality curves, 10.5/60.7% (systolic/diastolic) clustered in the same individuals. The validation criterion 1 [mean test-reference BP difference ≤5 ±â€Š8 (SD) mmHg] was satisfied for readings with good (0.1 ±â€Š4.9/0.3 ±â€Š3.8 mmHg, systolic/diastolic) and fair-quality curves (-0.4 ±â€Š6.4/0.2 ±â€Š5.0), but not for poor-quality ones (2.7 ±â€Š8.8/3.6 ±â€Š8.1). By excluding poor-quality readings (40 of 255), criterion 1 of the validation study was improved (0.2 ±â€Š4.9/0.2 ±â€Š3.9 versus 0.3 ±â€Š5.5/0.6 ±â€Š4.7 mmHg). CONCLUSION: The visual assessment of Korotkoff sounds generated during automated auscultatory BP measurement by the KOROT P3 Accurate professional monitor identifies unreliable readings and further improves the device accuracy.

2.
J Hypertens ; 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38690937

ABSTRACT

OBJECTIVES: Blood pressure (BP) variability (BPV) can be assessed using office (OBP), home (HBP), or ambulatory BP (ABP) measurements. This analysis investigated the association and agreement between OBP, HBP, and ABP measurements for BPV assessment at baseline and 10 weeks after initiating antihypertensive drug therapy. METHODS: Untreated hypertensive patients with elevated BPV were randomized to receive an angiotensin-converting enzyme inhibitor (ramipril) or a calcium channel blocker (nifedipine GITS) in a 10-week, open-label, blinded-end point study. BPV was assessed using standard deviation (SD) and coefficient of variation (CV) (reading-to-reading analyses). RESULTS: Data from 146 participants from three research centers (Athens/Greece; Milan/Italy; Shanghai/China) were analyzed [mean age 53 ±â€Š10 (SD) years, male individuals 60%, baseline systolic OBP, HBP, and 24 h ABP 144 ±â€Š9, 138 ±â€Š10, and 143 ±â€Š10 mmHg, respectively]. Post-treatment minus pre-treatment systolic CV difference was: OBP: 0.3%, P = 0.28; HBP: -0.2%, P = 0.20; 24 h ABP: 1.1%, P < 0.001. Home and ambulatory (not office) BPV indices presented weak-to-moderate correlation, both before and during treatment (range of coefficients 0.04-0.33). The correlation coefficient between systolic HBP CV and awake ABP CV was 0.21 and 0.28 before and during treatment, respectively (P < 0.05/< 0.001, respectively). Home and ambulatory (not office) BPV indices presented slight to fair agreement (range 64-73%) in detecting participants with high systolic BPV (top quartile of respective distributions) both before and during treatment (kappa range 0.04-0.27). CONCLUSION: These data showed a weak-to-moderate association between out-of-office (but not office) BPV indices both before and during BP-lowering treatment, with reasonable agreement in detecting individuals with high BPV. Out-of-office BP measurements provide more similar and consistent BPV information than office measurements.

3.
BMC Med ; 22(1): 190, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715060

ABSTRACT

Metabolic syndrome (MetS) is becoming prevalent in the pediatric population. The existing pediatric MetS definitions (e.g., the International Diabetes Federation (IDF) definition and the modified National Cholesterol Education Program (NCEP) definition) involve complex cut-offs, precluding fast risk assessment in clinical practice.We proposed a simplified definition for assessing MetS risk in youths aged 6-17 years, and compared its performance with two existing widely used pediatric definitions (the IDF definition, and the NCEP definition) in 10 pediatric populations from 9 countries globally (n = 19,426) using the receiver operating characteristic (ROC) curve analyses. In general, the total MetS prevalence of 6.2% based on the simplified definition was roughly halfway between that of 4.2% and 7.7% estimated from the IDF and NCEP definitions, respectively. The ROC curve analyses showed a good agreement between the simplified definition and two existing definitions: the total area under the curve (95% confidence interval) of the proposed simplified definition for identifying MetS risk achieved 0.91 (0.89-0.92) and 0.79 (0.78-0.81) when using the IDF or NCEP definition as the gold standard, respectively.The proposed simplified definition may be useful for pediatricians to quickly identify MetS risk and cardiometabolic risk factors (CMRFs) clustering in clinical practice, and allow direct comparison of pediatric MetS prevalence across different populations, facilitating consistent pediatric MetS risk monitoring and the development of evidence-based pediatric MetS prevention strategies globally.


Subject(s)
Metabolic Syndrome , Humans , Metabolic Syndrome/epidemiology , Metabolic Syndrome/diagnosis , Adolescent , Child , Male , Female , Prevalence , ROC Curve , Global Health , Risk Assessment/methods , Risk Factors
4.
J Hypertens ; 42(6): 939-947, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38647124

ABSTRACT

Recent evidence suggests that an exaggerated blood pressure (BP) response to standing (ERTS) is associated with an increased risk of adverse outcomes, both in young and old individuals. In addition, ERTS has been shown to be an independent predictor of masked hypertension. In the vast majority of studies reporting on the prognostic value of orthostatic hypertension (OHT), the definition was based only on systolic office BP measurements. This consensus statement provides recommendations on the assessment and management of individuals with ERTS and/or OHT. ERTS is defined as an orthostatic increase in SBP at least 20 mmHg and OHT as an ERTS with standing SBP at least 140 mmHg. This statement recommends a standardized methodology to assess ERTS, by considering body and arm position, and the number and timing of BP measurements. ERTS/OHT should be confirmed in a second visit, to account for its limited reproducibility. The second assessment should evaluate BP changes from the supine to the standing posture. Ambulatory BP monitoring is recommended in most individuals with ERTS/OHT, especially if they have high-normal seated office BP. Implementation of lifestyle changes and close follow-up are recommended in individuals with ERTS/OHT and normotensive seated office BP. Whether antihypertensive treatment should be administered in the latter is unknown. Hypertensive patients with ERTS/OHT should be managed as any other hypertensive patient. Standardized standing BP measurement should be implemented in future epidemiological and interventional studies.


Subject(s)
Blood Pressure , Hypertension , Humans , Hypertension/physiopathology , Hypertension/diagnosis , Hypertension/therapy , Blood Pressure/physiology , Blood Pressure Determination/methods , Consensus , Standing Position , Europe , Blood Pressure Monitoring, Ambulatory/methods
6.
Hypertension ; 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38602099

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is often asymptomatic and undiagnosed. As AF and hypertension often coexist, opportunistic AF detection during routine automated blood pressure (BP) measurement appears to be an attractive screening method. METHODS: A systematic literature search was conducted to identify studies assessing the diagnostic test accuracy of office, home, or 24-hour ambulatory BP measuring devices with AF detection algorithms versus reference electrocardiography. Analyses were performed per participant (AF status based on several BP readings; most office/home devices) or per reading (AF status based on individual readings; all ambulatory devices). A meta-analysis stratified by device type (office/home/ambulatory) was conducted to calculate pooled measures of diagnostic accuracy. Sensitivity/meta-regression analyses were also performed. RESULTS: Among 3096 records initially retrieved, 23 diagnostic test accuracy studies were included. Data derived from 11 093 individuals (weighted age 69 years, males 56%, hypertensives 79%, diabetics 24%, and AF prevalence 17%) indicated a pooled sensitivity 0.97 (95% CI, 0.92-0.99), specificity 0.93 (95% CI, 0.90-0.95), and accuracy 0.93 (95% CI, 0.89-0.95), with generally consistent results using office, home, or ambulatory BP devices (slightly lower specificity with the latter). The positive and negative predictive values were 0.70 (95% CI, 0.60-0.80) and 0.99 (95% CI, 0.98-1.00), respectively. Sensitivity analyses indicated lower specificity in studies implementing reading versus participant analyses. Most studies presented a low risk of bias and minor applicability concerns. CONCLUSIONS: There is considerable and consistent evidence suggesting high diagnostic accuracy of AF detection algorithms implemented in automated BP monitors during routine BP measurements in and out of the office. AF diagnosis requires verification (electrocardiography) before treatment is administered.

7.
J Clin Med ; 13(6)2024 Mar 18.
Article in English | MEDLINE | ID: mdl-38541976

ABSTRACT

Background: Telemedicine is increasingly used in several fields of healthcare, including vascular medicine. This study aimed to investigate the views of experts and propose clinical practice recommendations on the possible applications of telemedicine in vascular medicine. Methods: A clinical guidance group proposed a set of 67 clinical practice recommendations based on the synthesis of current evidence and expert opinion. The Telemedicine Vascular Medicine Working Group included 32 experts from Europe evaluating the appropriateness of each clinical practice recommendation based on published RAND/UCLA methodology in two rounds. Results: In the first round, 60.9% of clinical practice recommendations were rated as appropriate, 35.9% as uncertain, and 3.1% as inappropriate. The strongest agreement (a median value of 10) was reached on statements regarding the usefulness of telemedicine during the 2019 coronavirus disease (COVID-19) pandemic, its usefulness for geographical areas that are difficult to access, and the superiority of video calls compared to phone calls only. The lowest degree of agreement (a median value of 2) was reported on statements regarding the utility of telemedicine being limited to the COVID-19 pandemic and regarding the applicability of teleconsultation in the diagnosis and management of abdominal aortic aneurysm. In the second round, 11 statements were re-evaluated to reduce variability. Conclusions: This study highlights the levels of agreement and the points that raise concern on the use of telemedicine in vascular medicine. It emphasizes the need for further clarification on various issues, including infrastructure, logistics, and legislation.

8.
Medicina (Kaunas) ; 60(2)2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38399618

ABSTRACT

Background and Objectives: The success of combined antiretroviral therapy (cART) has led to a dramatic improvement in the life expectancy of people living with HIV (PLWH). However, there has been an observed increase in cardiometabolic, bone, renal, hepatic, and neurocognitive manifestations, as well as neoplasms, known as serious non-AIDS events/SNAEs, compared to the general population of corresponding age. This increase is linked to a harmful phenomenon called inflammaging/immunosenescence, which is driven by chronic immune activation and intestinal bacterial translocation. In this study, we examined immunological and metabolic parameters in individuals receiving current cART. Materials and Methods: The study was conducted at Laiko General Hospital in Athens, Greece. Plasma concentrations of sCD14, IL-6, SuPAR, I-FABP, and LBP were measured in virally suppressed PLWH under cART with at least 350 CD4 lymphocytes/µL. We compared these levels between PLWH receiving integrase strand transfer inhibitors (INSTIs) and protease inhibitors (PIs) and attempted to correlate them with chronic immune activation and metabolic parameters. Results: Data from 28 PLWH were analyzed, with a mean age of 52 and 93% being males. Among the two comparison groups, IL-6 levels were higher in the PIs group (5.65 vs. 7.11 pg/mL, p = 0.03). No statistically significant differences were found in the other measured parameters. A greater proportion of PLWH under INSTIs had normal-range LBP (33% vs. 0%, p = 0.04). When using inverse probability of treatment weighting, no statistically significant differences in the measured parameters were found between the two groups (sCD14 p = 0.511, IL-6 p = 0.383, SuPAR p = 0.793, I-FABP p = 0.868, and LBP p = 0.663). Glucose levels were found to increase after viral suppression in the entire sample (92 mg/dL vs. 98 mg/dL, p = 0.009). Total (191 mg/dL vs. 222 mg/dL, p = 0.005) and LDL cholesterol (104 mg/dL vs. 140 mg/dL, p = 0.002) levels were higher in the PIs group. No significant differences were observed in liver and renal function tests. Conclusions: Further investigation is warranted for PLWH on cART-containing INSTI regimens to explore potential reductions in chronic immune activation and intestinal bacterial translocation.


Subject(s)
HIV Infections , Protease Inhibitors , Humans , Male , Middle Aged , Female , Receptors, Urokinase Plasminogen Activator , Interleukin-6 , Lipopolysaccharide Receptors , HIV Infections/complications , HIV Infections/drug therapy , Integrases , Peptide Hydrolases
10.
Cancers (Basel) ; 16(2)2024 Jan 20.
Article in English | MEDLINE | ID: mdl-38275891

ABSTRACT

Cancer-associated thrombosis (CAT) is a common complication in lung cancer patients. Lung cancer confers an increased risk of thrombosis compared to other solid malignancies across all stages of the disease. Newer treatment agents, including checkpoint immunotherapy and targeted agents, may further increase the risk of CAT. Different risk-assessment models, such as the Khorana Risk Score, and newer approaches that incorporate genetic risk factors have been used in lung cancer patients to evaluate the risk of thrombosis. The management of CAT is based on the results of large prospective trials, which show similar benefits to low-molecular-weight heparins (LMWHs) and direct oral anticoagulants (DOACs) in ambulatory patients. The anticoagulation agent and duration of therapy should be personalized according to lung cancer stage and histology, the presence of driver mutations and use of antineoplastic therapy, including recent curative lung surgery, chemotherapy or immunotherapy. Treatment options should be evaluated in the context of the COVID-19 pandemic, which has been shown to impact the thrombotic risk in cancer patients. This review focuses on the epidemiology, pathophysiology, risk factors, novel predictive scores and management of CAT in patients with active lung cancer, with a focus on immune checkpoint inhibitors.

11.
J Hypertens ; 42(3): 385-392, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38164947

ABSTRACT

OBJECTIVES: Ambulatory (ABP) and self-home blood pressure (HBP) measurements are known to be superior to office blood pressure (OBP) measurements in predicting cardiovascular events. Whether ABP has superior prognostic ability than HBP, or the reverse, has not been adequately investigated. METHODS: A systematic literature search was conducted to identify outcome studies investigating HBP and ABP in the same population. A meta-analysis was conducted to calculate the pooled measure of risk regarding the primary endpoint of each study for each method. Primary analysis included the comparison of pooled estimates of HBP versus 24 h ABP. RESULTS: Among 2587 articles retrieved, 6 fulfilled the inclusion criteria. Meta-analysis of five studies ( n  = 4439, weighted age 57 years, men 52%, hypertension 68%, diabetes 15%, cardiovascular disease 11%) indicated pooled hazard ratio per 10 mmHg increase in systolic HBP 1.36 (95% CI 1.23-1.50) and in 24 h ABP 1.38 (1.22-1.57) for the primary endpoint of each study ( z -test P  = NS). Meta-analysis of five studies ( n  = 4497, weighted age 58 years, men 51%, hypertension 65%, diabetes 15%, cardiovascular disease 9%) indicated pooled hazard ratio per 10 mmHg increase in systolic HBP 1.29 (1.14-1.47), daytime ABP 1.30 (1.15-1.46) and nighttime ABP 1.31 (1.14-1.50) ( z -test, P  = NS). Data for DBP were similar. All studies were deemed to have low risk of bias. In studies comparing all the three methods, OBP provided the lowest hazard ratio. CONCLUSION: This meta-analysis of the available prospective outcome studies suggested that HBP and ABP have similar ability in predicting outcome and superior to OBP.


Subject(s)
Cardiovascular Diseases , Diabetes Mellitus , Hypertension , Male , Humans , Middle Aged , Blood Pressure Monitoring, Ambulatory , Blood Pressure Determination/methods , Cardiovascular Diseases/diagnosis , Prognosis , Prospective Studies , Hypertension/diagnosis , Blood Pressure/physiology , Diabetes Mellitus/diagnosis
12.
Blood Press Monit ; 29(2): 99-102, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-37997431

ABSTRACT

OBJECTIVE: To evaluate the blood pressure (BP) measurement accuracy of the Braun BUA4000 automated oscillometric upper-arm cuff device for self-home use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01. METHODS: Participants were recruited to fulfill the age, sex, BP and limb circumference distribution criteria of the AAMI/ESH/ISO Universal Standard in a general population using the same arm sequential BP measurement method. A single wide-range cuff of the test device was used for arm circumference range 22-42 cm. RESULTS: A total of 98 individuals were recruited and 85 were analyzed [mean age 60.3 ±â€…16.1 (SD) years, 44 men, arm circumference 31.5 ±â€…5.1 cm, range 22-41.5 cm]. For validation criterion 1, the mean difference ± SD between the test device and reference BP readings ( N  = 255) was 0.9 ±â€…6.4/-0.3 ±â€…6.4 mmHg (systolic/diastolic; threshold ≤5 ±â€…8 mmHg). For criterion 2, the SD of the averaged BP differences between the test device and reference BP per individual ( N  = 85) was 5.15/5.81 mmHg (systolic/diastolic; threshold ≤6.88/6.95 mmHg). CONCLUSION: The Braun BUA4000 automated oscillometric BP monitor fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard in a general population and can be recommended for self-monitoring of BP by patients at home.


Subject(s)
Blood Pressure Monitors , Hypertension , Male , Humans , Adult , Middle Aged , Aged , Blood Pressure , Hypertension/diagnosis , Blood Pressure Determination , Reference Standards
13.
Blood Press Monit ; 29(2): 89-92, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-37937605

ABSTRACT

OBJECTIVE: This study evaluated the accuracy of the automated oscillometric upper-arm cuff device AVITA BPM82 intended for home use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01. METHODS: Participants were recruited to fulfill the age, sex, blood pressure (BP), and limb distribution criteria of the AAMI/ESH/ISO Universal Standard and its Amendment 1.2020-01 in a general population using the same arm sequential BP measurement method. Two cuffs of the test device were used for arm circumference 22-33 (medium) and 33-42 cm (large). RESULTS: One-hundred-one individuals were recruited and 85 were analyzed [mean age 57.3 ±â€…15.1 (SD) years, 46 men, arm circumference 32 ±â€…5.1 cm, range 22.3-42 cm]. For validation Criterion 1, the mean difference ±SD between the test device and reference BP readings (N = 255) was 1.3 ±â€…6.5/3.6 ±â€…5.9 mmHg (systolic/diastolic; threshold ≤5 ±â€…8 mmHg). For Criterion 2, the SD of the averaged BP differences between the test device and reference BP per individual (N = 85) was 5.70/5.25 mmHg (systolic/diastolic; threshold ≤6.82/5.89 mmHg). CONCLUSIONS: The automated oscillometric home BP monitor AVITA BPM82 comfortably fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01 in a general population and can be recommended for clinical use.


Subject(s)
Blood Pressure Monitors , Hypertension , Male , Humans , Adult , Middle Aged , Aged , Blood Pressure , Hypertension/diagnosis , Blood Pressure Determination , Reference Standards
15.
Hypertens Res ; 47(3): 790-793, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38123713

ABSTRACT

This study investigated the seasonal effect on blood pressure (BP) variability. Patients on stable antihypertensive drug treatment were assessed with office (OBP), home (HBP), and ambulatory BP (ABP) measurements in winter, next summer, and in next winter. Fifty-eight participants with full data for winter and summer were analyzed (mean age 65.2 ± 7.9 [SD], 64% males). OBP, HBP and ABP (24-h; daytime) were lower in summer than in winter (P < 0.01), whereas nighttime ABP was unchanged (p = NS). Standard deviation (SD), coefficient of variation (CV) and average real variability (ARV) for systolic OBP were higher in winter than summer (p < 0.01/ < 0.05/ < 0.01, respectively). These indices for HBP and ABP measurements did not differ in winter and summer (p = NS). Forty participants had complete data for winter-summer-next winter and HBP/ABP variability indices did not differ for both winters versus summer. These preliminary data suggest that BP variability is unaffected by seasonal changes in contrast to average BP levels.


Subject(s)
Blood Pressure Determination , Hypertension , Male , Humans , Middle Aged , Aged , Female , Blood Pressure/physiology , Seasons , Blood Pressure Monitoring, Ambulatory
16.
Pharmaceutics ; 15(11)2023 Oct 25.
Article in English | MEDLINE | ID: mdl-38004506

ABSTRACT

Type 2 diabetes mellitus is a major health problem worldwide with a steadily increasing prevalence reaching epidemic proportions. The major concern is the increased morbidity and mortality due to diabetic complications. Traditional but also nontraditional risk factors have been proposed to explain the pathogenesis of type 2 diabetes mellitus and its complications. Hyperglycemia has been considered an important risk factor, and the strict glycemic control can have a positive impact on microangiopathy but not macroangiopathy and its related morbidity and mortality. Thus, the therapeutic algorithm has shifted focus from a glucose-centered approach to a strategy that now emphasizes target-organ protection. Sodium-glucose transporter 2 inhibitors is an extremely important class of antidiabetic medications that, in addition to their glucose lowering effect, also exhibit cardio- and renoprotective effects. Various established and novel biomarkers have been described, reflecting kidney and cardiovascular function. In this review, we investigated the changes in established but also novel biomarkers of kidney, heart and vascular function associated with sodium-glucose transporter 2 inhibitors treatment in patients with type 2 diabetes mellitus.

17.
BMC Med ; 21(1): 442, 2023 11 15.
Article in English | MEDLINE | ID: mdl-37968681

ABSTRACT

BACKGROUND: Waist-to-height ratio (WHtR) has been proposed as a simple and effective screening tool for assessing central obesity and cardiometabolic risk in both adult and pediatric populations. However, evidence suggests that the use of a uniform WHtR cut-off of 0.50 may not be universally optimal for pediatric populations globally. We aimed to determine the optimal cut-offs of WHtR in children and adolescents with increased cardiometabolic risk across different countries worldwide. METHODS: We used ten population-based cross-sectional data on 24,605 children and adolescents aged 6-18 years from Brazil, China, Greece, Iran, Italy, Korea, South Africa, Spain, the UK, and the USA for establishing optimal WHtR cut-offs. We performed an external independent test (9,619 children and adolescents aged 6-18 years who came from other six countries) to validate the optimal WHtR cut-offs based on the predicting performance for at least two or three cardiometabolic risk factors. RESULTS: Based on receiver operator characteristic curve analyses of various WHtR cut-offs to discriminate those with ≥ 2 cardiometabolic risk factors, the relatively optimal percentile cut-offs of WHtR in the normal weight subsample population in each country did not always coincide with a single fixed percentile, but varied from the 75th to 95th percentiles across the ten countries. However, these relatively optimal percentile values tended to cluster irrespective of sex, metabolic syndrome (MetS) criteria used, and WC measurement position. In general, using ≥ 2 cardiometabolic risk factors as the predictive outcome, the relatively optimal WHtR cut-off was around 0.50 in European and the US youths but was lower, around 0.46, in Asian, African, and South American youths. Secondary analyses that directly tested WHtR values ranging from 0.42 to 0.56 at 0.01 increments largely confirmed the results of the main analyses. In addition, the proposed cut-offs of 0.50 and 0.46 for two specific pediatric populations, respectively, showed a good performance in predicting ≥ 2 or ≥ 3 cardiometabolic risk factors in external independent test populations from six countries (Brazil, China, Germany, Italy, Korea, and the USA). CONCLUSIONS: The proposed international WHtR cut-offs are easy and useful to identify central obesity and cardiometabolic risk in children and adolescents globally, thus allowing international comparison across populations.


Subject(s)
Cardiovascular Diseases , Metabolic Syndrome , Adult , Humans , Adolescent , Child , Obesity, Abdominal/complications , Obesity, Abdominal/diagnosis , Cross-Sectional Studies , Obesity/complications , Metabolic Syndrome/diagnosis , Metabolic Syndrome/epidemiology , Metabolic Syndrome/complications , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/complications , Waist Circumference , Body Mass Index , Waist-Height Ratio , Risk Factors
18.
Hellenic J Cardiol ; 73: 84-85, 2023.
Article in English | MEDLINE | ID: mdl-37429505

ABSTRACT

The optimal diuretic choice [hydrochlorothiazide (HCTZ) or chlorthalidone (CTD)] for the management of hypertension has been an ongoing debate for several years. HCTZ is widely used in the form of single-pill combinations, whereas CTD is a more potent drug vs. HCTZ, especially in reducing nighttime blood pressure (BP), with some indirect evidence suggesting a superiority in terms of cardiovascular (CV) risk reduction. In addition, recent data showed that CTD was safe and effective in terms of BP lowering in predialysis patients with stage 4 chronic kidney disease. The Diuretic Comparison Project was the first head-to-head pragmatic, open-label trial that randomly assigned elderly patients with hypertension under HCTZ therapy to continue with HCTZ or to switch to CTD (equivalent doses). Office BP was similar for both groups throughout the study. The trial showed no difference in major CV events or non-cancer-related deaths during a median follow-up of 2.4 years; yet, CTD was associated with a benefit in participants with a previous myocardial infarction or stroke, which might be a chance finding but could also indicate that a high-risk population is more suitable for revealing the impact of slight differences in the 24-hour BP profile in a relatively short-term follow-up. Interestingly CTD vs. HCTZ was associated with higher hypokalemia rates apart from the latter group of patients where there was no difference. Overall, the available data do not confirm the superiority of CTD over HCTZ in general, but this could be questionable in selected patients.


Subject(s)
Cardiovascular Diseases , Hypertension , Humans , Aged , Chlorthalidone/therapeutic use , Chlorthalidone/pharmacology , Hydrochlorothiazide/therapeutic use , Hydrochlorothiazide/pharmacology , Cardiovascular Diseases/prevention & control , Cardiovascular Diseases/drug therapy , Antihypertensive Agents/therapeutic use , Antihypertensive Agents/pharmacology , Hypertension/complications , Hypertension/drug therapy , Diuretics/therapeutic use , Blood Pressure , Drug Therapy, Combination
19.
J Hypertens ; 41(12): 2074-2087, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37303198

ABSTRACT

BACKGROUND: There is intense effort to develop cuffless blood pressure (BP) measuring devices, and several are already on the market claiming that they provide accurate measurements. These devices are heterogeneous in measurement principle, intended use, functions, and calibration, and have special accuracy issues requiring different validation than classic cuff BP monitors. To date, there are no generally accepted protocols for their validation to ensure adequate accuracy for clinical use. OBJECTIVE: This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability recommends procedures for validating intermittent cuffless BP devices (providing measurements every >30 sec and usually 30-60 min, or upon user initiation), which are most common. VALIDATION PROCEDURES: Six validation tests are defined for evaluating different aspects of intermittent cuffless devices: static test (absolute BP accuracy); device position test (hydrostatic pressure effect robustness); treatment test (BP decrease accuracy); awake/asleep test (BP change accuracy); exercise test (BP increase accuracy); and recalibration test (cuff calibration stability over time). Not all these tests are required for a given device. The necessary tests depend on whether the device requires individual user calibration, measures automatically or manually, and takes measurements in more than one position. CONCLUSION: The validation of cuffless BP devices is complex and needs to be tailored according to their functions and calibration. These ESH recommendations present specific, clinically meaningful, and pragmatic validation procedures for different types of intermittent cuffless devices to ensure that only accurate devices will be used in the evaluation and management of hypertension.


Subject(s)
Blood Pressure Determination , Hypertension , Humans , Blood Pressure/physiology , Hypertension/diagnosis , Sphygmomanometers , Blood Pressure Monitors
20.
J Hypertens ; 41(12): 2088-2094, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37303225

ABSTRACT

OBJECTIVE: To develop scientific consensus recommendations for the optimal design and functions of different types of blood pressure (BP) measuring devices used in clinical practice for the detection, management, and long-term follow-up of hypertension. METHODS: A scientific consensus meeting was performed by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability and STRIDE BP (Science and Technology for Regional Innovation and Development in Europe) during the 2022 Scientific Meeting of the ESH in Athens, Greece. Manufacturers were also invited to provide their feedback on BP device design and development. Thirty-one international experts in clinical hypertension and BP monitoring contributed to the development of consensus recommendations on the optimal design of BP devices. STATEMENT: International consensus was reached on the requirements for the design and features of five types of BP monitors, including office (or clinic) BP monitors, ambulatory BP monitors, home BP monitors, home BP telemonitors, and kiosk BP monitors for public spaces. For each device type "essential" requirements (must have), and "optional" ones (may have) are presented, as well as additional comments on the optimal device design and features. CONCLUSIONS: These consensus recommendations aim at providing manufacturers of BP devices with the requirements that are considered mandatory, or optional, by clinical experts involved in the detection and management of hypertension. They are also directed to administrative healthcare personnel involved in the provision and purchase of BP devices so that they can recommend the most appropriate ones.


Subject(s)
Blood Pressure Determination , Hypertension , Humans , Blood Pressure , Reproducibility of Results , Hypertension/diagnosis , Hypertension/therapy , Sphygmomanometers , Blood Pressure Monitoring, Ambulatory
SELECTION OF CITATIONS