Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 60
Filter
1.
Int J Implant Dent ; 10(1): 9, 2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38372934

ABSTRACT

PURPOSE: Tricalcium phosphate (TCP) has osteoconductive ability and reportedly offers similar clinical results as autogenous bone grafts in dental implant treatment. However, few reports quantify temporal changes in augmented bone volume after sinus augmentation. We aimed to establish a three-dimensional (3D) quantification method to assess bone volume after sinus augmentation and to evaluate biocompatibility of the TCP plate. METHODS: Maxillary sinus floor augmentation was performed employing the lateral window technique, and plate-shaped ß-TCP (TCP plate) was used instead of granular bone grafting materials. After lifting the sinus membrane, the TCP plate was inserted and supported by dental implants or micro-screws. The changes in bone volumes in the maxillary sinus before and after surgery were recorded using cone-beam computed tomography, saved as Digital Imaging and Communications in Medicine-formatted files, and transformed to Standard Triangle Language (STL)-formatted files. Pre- and post-operative STL data of bone volume were superimposed, and the augmented bone volume was calculated. Moreover, changes in bone volumes, TCP plate resorption rates, and bone heights surrounding the implants were three dimensionally quantified. RESULTS: Fifteen implants in nine subjects were included in this study. TCP plates secured long-term space making, with results similar to those of granular bone substitutes. Newly formed bone was identified around the implant without bone graft material. TCP plate was absorbed and gradually disappeared. CONCLUSIONS: A novel 3D quantification method was established to evaluate changes in bone volume. Clinical application of TCP plate in sinus augmentation could be a better procedure in terms of prognosis and safety.


Subject(s)
Bone Substitutes , Calcium Phosphates , Sinus Floor Augmentation , Humans , Bone Substitutes/therapeutic use , Maxillary Sinus/diagnostic imaging , Maxillary Sinus/surgery , Bone Plates
2.
J Prosthodont Res ; 68(1): 132-138, 2024 Jan 16.
Article in English | MEDLINE | ID: mdl-37316261

ABSTRACT

PURPOSE: The purpose of this study is to investigate the effects of denture adhesives on masticatory performance via a 10-center, parallel, randomized, controlled trial of complete denture wearers in Japan. METHODS: The trial was conducted between September 2013 and October 2016. The inclusion criteria were complete edentulism, willingness to undergo new complete denture treatment, and willingness to return for recall treatment. The exclusion criteria were age 90 years or older, presence of severe systemic illness, inability to understand the questionnaires, wearing metal base complete dentures, denture adhesive user, wearing prosthetics for maxillofacial defects, wearing complete dentures with tissue conditioners, and severe xerostomia. Randomization of the powder-type denture adhesive (powder), cream-type denture adhesive (cream), and control (saline) groups was performed using a sealed envelope system. Masticatory performance was measured using color-changeable chewing gum. Intervention blinding was not feasible. RESULTS: Sixty-seven control, 69 powder, and 64 cream participants are analyzed using the intention-to-treat principle. The participants in all groups show significantly improved masticatory performance at post-intervention (paired t-test with Bonferroni correction P < 0.0001). However, no significant difference in masticatory performance is detected among the three groups (one-way analysis of variance). A significant negative correlation between pre- and post-changes in masticatory performance and intraoral condition scores is observed (Pearson's correlation coefficient, P < 0.0001). CONCLUSIONS: Although denture adhesives improved the masticatory performance of complete denture wearers, their clinical effects are comparable to those of saline solution. The use of denture adhesives is more effective in complete denture wearers with unsatisfactory intraoral conditions.


Subject(s)
Mouth, Edentulous , Tooth Loss , Humans , Aged, 80 and over , Powders , Denture, Complete , Chewing Gum , Mastication
3.
J Prosthodont Res ; 67(4): 619-625, 2023 Oct 13.
Article in English | MEDLINE | ID: mdl-36967125

ABSTRACT

PURPOSE: This study aimed to clarify the effect of occlusal force on appropriate optical interocclusal registration in clinical practice, considering periodontal ligament and jawbone deformation. METHODS: Forty participants with natural, healthy dentition were enrolled (19 men and 21 women; mean age, 27.7 ± 2.0 years). A TRIOS3 intraoral scanner was used to scan the right lateral first premolar to the second molar areas of the upper and lower jaws. During scanning for interocclusal registration, participants were instructed to "bite normally," "bite lightly," and "bite strongly" to obtain data for the three occlusal patterns. The standard triangulated language (STL) data for each occlusion condition were superimposed using the appropriate software, following which the tooth displacement was calculated. The conventional method was also used to record the occlusal contact area for a silicone model using a dental contact analyzer. RESULTS: Tooth displacement was significantly lower for the strong-bite condition than for the weak-bite condition (0.018 mm vs. 0.028 mm, P<0.05). As the occlusal force increased, the occlusal contact area also increased, and significant differences were observed among the different occlusal conditions (P<0.05). CONCLUSIONS: Occlusal contact area changed depending on the bite force when using the silicone impression or optical intraoral scanning methods. Moreover, using optical impression methods in "strong bite force" may reduce the deviation and allow for stable interocclusal registration.


Subject(s)
Bite Force , Dental Occlusion , Male , Humans , Female , Adult , Bicuspid , Molar , Silicones
4.
J Clin Med ; 12(3)2023 Jan 31.
Article in English | MEDLINE | ID: mdl-36769770

ABSTRACT

The purpose of this retrospective study was to evaluate computer-assisted virtual surgery and the outcomes of mandibular reconstruction using an autogenous particulate cancellous bone and marrow (PCBM) graft combined with a custom-made titanium mesh (TiMesh) using a three-dimensional (3D) printing model. Eighteen consecutive patients were included, and preoperative virtual simulation surgery was performed using digital data. Segmental bone defects showed deviation of the mandible due to displacement of the condyle and segments, unnatural length of the mandibular body, or poorer intermaxillary relationship compared to the marginal bone defect caused by previous operations. These mandibular disharmonies could be simulated, and virtual surgery was performed on a computer with adjustment of displaced mandibular segments, length of the mandibular body, and dental arch with digital bone augmentation. TiMesh was manually pre-bent using a 3D printing model, and PCBM from the iliac crest was grafted with TiMesh. The short-term clinical results were good; reconstruction of the alveolar crest was prosthetically desirable; and minor complications were observed. In conclusion, virtual reconstruction is crucial for treating complex deviated mandibles. Accurate condylar and dental arch positions with an optimum mandibular length are important for prosthetically satisfactory mandibular reconstruction.

5.
J Prosthodont Res ; 67(4): 548-555, 2023 Oct 13.
Article in English | MEDLINE | ID: mdl-36740264

ABSTRACT

PURPOSE: This study aimed to determine the effects of denture adhesives on denture retention and occlusal force in complete denture wearers in a multicenter, randomized, parallel-group controlled trial. METHODS: Two hundred edentulous patients wearing complete dentures were allocated to three groups: powder-type denture adhesive, cream-type denture adhesive, and control (saline solution). Denture adhesives and saline solution were applied to the dentures for 4 days. The retentive force of the dentures and occlusal force were measured using a force transducer occlusal force meter at baseline and after 4 days of intervention. In addition to between-group comparisons, subgroup analyses of denture retention and occlusal force were performed based on the level of difficulty of the edentulism treatment. The levels were ranked as I (easy), II, III, and IV (difficult). RESULTS: Cream-type denture adhesives significantly improved the retentive force of the dentures (P<0.01) and occlusal force (P<0.05), with no significant differences between baseline and post-intervention forces in the powder-type denture adhesive and control groups. In within-group comparisons, cream-type denture adhesives improved both the retentive and occlusal forces at Level II (P<0.05), and powder-type denture adhesives improved the occlusal force at Level II (P<0.01). CONCLUSIONS: Application of cream-type denture adhesives effectively improves the denture retention and occlusal force in complete denture wearers with a moderate degree of difficulty during edentulism treatment.

6.
Int J Mol Sci ; 24(2)2023 Jan 06.
Article in English | MEDLINE | ID: mdl-36674618

ABSTRACT

New bone-forming substitute materials are highly useful in dental implantology. The purpose of this study was to prepare cross-linked hyaluronic acid (cHLA)/cross-linked alkaline gelatin (cAG)/nano-hydroxyapatite (nHAp)/bone morphogenic protein (BMP) constructs; and evaluate their bone-forming capabilities in rat cranial bone defects. The cHLA and cAG liquids processed with an epoxy cross-linker were blended with a 3:1 volume ratio, followed by freeze-drying. The dry composites were further infiltrated with water containing nHAp only (BMP (−)) or with water containing nHAp and BMP (BMP (+)). Prepared wet constructs (BMP (−) and BMP (+)) were implanted in rat cranial bone defects, while defects only were also made, and animals were fed for 8 weeks, followed by subsequent soft X-ray measurements and histological observations. The X-ray results showed that BMP (+) constructs disappeared, though caused inward extension of peripherical bone from defect edges with an increase in length of approximately 24%, larger than those of BMP (−) constructs and defect only with approximately 17% and 8% increments, respectively (p < 0.05). Histological observations of BMP (+) construct samples clearly indicated active bone extension consisting of an array of island-like bones. It was concluded that cHLA/cAG/nHAp/BMP could be used as novel bone-substitute materials.


Subject(s)
Bone Substitutes , Osteogenesis , Rats , Animals , Durapatite , Gelatin , Hyaluronic Acid , Tissue Scaffolds , Bone Morphogenetic Proteins , Skull , Bone Morphogenetic Protein 2 , Bone Regeneration
7.
Polymers (Basel) ; 14(24)2022 Dec 08.
Article in English | MEDLINE | ID: mdl-36559734

ABSTRACT

New injection-type bone-forming materials are desired in dental implantology. In this study, we added nano-hydroxyapatite (nHAp) and bone morphogenetic protein (BMP) to cross-linkable thiol-modified hyaluronic acid (tHyA) and evaluated its usefulness as an osteoinductive injectable material using an animal model. The sol (ux-tHyA) was changed to a gel (x-tHyA) by mixing with a cross-linker. We prepared two sol−gel (SG) material series, that is, x-tHyA + BMP with and without nHAp (SG I) and x-tHyA + nHAp with and without BMP (SG II). SG I materials in the sol stage were injected into the cranial subcutaneous connective tissues of mice, followed by in vivo gelation, while SG II materials gelled in Teflon rings were surgically placed directly on the cranial bones of rats. The animals were sacrificed 8 weeks after implantation, followed by X-ray analysis and histological examination. The results revealed that bone formation occurred at a high rate (>70%), mainly as ectopic bone in the SG I tests in mouse cranial connective tissues, and largely as bone augmentation in rat cranial bones in the SG II experiments when x-tHyA contained both nHAp and BMP. The prepared x-tHyA + nHAp + BMP SG material can be used as an injection-type osteoinductive bone-forming material. Sub-periosteum injection was expected.

8.
Materials (Basel) ; 15(24)2022 Dec 09.
Article in English | MEDLINE | ID: mdl-36556608

ABSTRACT

Bone-substitute materials are essential in dental implantology. We prepared collagen (Col)/hydroxyapatite (Hap)/acidic gelatin (AG)/basic fibroblast growth factor (b-FGF) constructs with enhanced bone-forming capability. The Col/Hap apatite composites were prepared by immersing Col sponges alternately in calcium and phosphate ion solutions five times, for 20 and 60 min, respectively. Then, the sponges were heated to 56 °C for 48 h. Scanning electron microscopy/energy-dispersive X-ray spectroscopy, Fourier-transform infrared spectroscopy, and X-ray diffraction analyses showed that the Col/Hap composites contained poorly crystalline Hap precipitates on the Col matrix. Col/Hap composite granules were infiltrated by AG, freeze-dried, and immersed in b-FGF solution. The wet quaternary constructs were implanted in rat cranial bone defects for 8 weeks, followed by soft X-ray measurements and histological analysis. Animal studies have shown that the constructs moderately increase bone formation in cranial bone defects. We found that an alternate immersion time of 20 min led to the greatest bone formation (p < 0.05). Constructs placed inside defects slightly extend the preexisting bone from the defect edges and lead to the formation of small island-like bones inside the defect, followed by disappearance of the constructs. The combined use of Col, Hap, AG, and b-FGF might bring about novel bone-forming biomaterials.

9.
J Oral Sci ; 64(4): 257-262, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-35989295

ABSTRACT

The purpose of this review is to search for complications of dental implant superstructures and consider the issues involved. This narrative review was performed by searching through PubMed databases and review articles that were published after 1990. Misfitting of the superstructure can result in loosening of screws, reduced preload, and in some cases, significant stress around the implant. External connection modalities and single implant prostheses have been reported to have more loose or broken abutment screws. In addition, when zirconia abutment was used for platform shifting, the rate of fracture of the abutment was considered to be high. Additionally, it was reported that men were significantly at an increased risk of abutment fracture. As for the retention mechanism of implant overdenture, stud attachment (Locator type) should receive more attention to wear and damage of retention parts than other attachments. The causes of the complications of implant superstructures have not been clarified in some cases, and further verification is required. Verification of complications is considered important to obtain a long-term prognosis for superstructures of implants. It will be necessary to further verify complications of implants in the future.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Dental Abutments , Dental Implants/adverse effects , Dental Prosthesis, Implant-Supported/adverse effects , Dental Stress Analysis , Denture, Overlay , Humans , Male
10.
Materials (Basel) ; 15(9)2022 May 08.
Article in English | MEDLINE | ID: mdl-35591709

ABSTRACT

Osteo-conductive bone substitute materials are required in dentistry. In this study, highly pressed nano-hydroxyapatite/collagen (P-nHAP/COL) composites were formed by a hydraulic press. Critical-size bone defects (Φ = 6 mm) were made in the cranial bones of 10-week-old Wistar rats, in which P-nHAP/COL and pressed collagen (P-COL) specimens were implanted. Defect-only samples (DEF) were also prepared. After the rats had been nourished for 3 days, 4 weeks, or 8 weeks, ossification of the cranial defects of the rats was evaluated by micro-computed tomography (micro-CT) (n = 6 each). Animals were sacrificed at 8 weeks, followed by histological examination. On micro-CT, the opacity of the defect significantly increased with time after P-nHAP/COL implantation (between 3 days and 8 weeks, p < 0.05) due to active bone regeneration. In contrast, with P-COL and DEF, the opacity increased only slightly with time after implantation, indicating sluggish bone regeneration. Histological inspections of the defect zone implanted with P-nHAP/COL indicated the adherence of multinucleated giant cells (osteoclasts) to the implant with phagocytosis and fragmentation of P-nHAP/COL, whereas active bone formation occurred nearby. Fluorescent double staining indicated dynamic bone-formation activities. P-nHAP/COL is strongly osteo-conductive and could serve as a useful novel bone substitute material for future dental implant treatments.

11.
Int J Dent ; 2022: 7331185, 2022.
Article in English | MEDLINE | ID: mdl-35464101

ABSTRACT

Objectives: Although digital technology has been widely integrated into dental education, there is limited literature investigating the extent of the integration of computer-aided design and computer-aided manufacturing (CAD-CAM) for removable systems in the dental curriculum. The purpose of this study was to assess the current implementation of CAD-CAM complete and partial dentures in predoctoral (PP) and advanced graduate prosthodontic (AGP) education in US dental schools. The study also aimed to identify potential barriers to its implementation in the dental curriculum. Methods: An online survey with 15 questions was created using online survey software. The survey was distributed to the directors of predoctoral prosthodontics in 56 schools and advanced graduate programs of prosthodontics in 52 schools listed in the 2018-19 American Dental Education Association (ADEA) Directory. Results: The percentage of programs (PP and AGP) implementing CAD-CAM complete dentures (CAD-CAM CDs) and CAD-CAM removable partial dentures (CAD-CAM RPDs) in their didactic, preclinical, and clinical curricula was recorded. CAD-CAM CDs are taught in didactic courses in 54.2% of PP and 65.2% of AGP. However, CAD-CAM RPDs are only taught in 37.5% of PP and 47.8% of AGP. Programs are largely limited by a lack of funds, resources, time, and faculty members. Conclusion: While digital technologies have indeed become more prevalent in dental education, many institutions face barriers to implementation. More research must be conducted in order to support the continued incorporation of digital technologies into dental education.

12.
Int J Implant Dent ; 8(1): 18, 2022 04 13.
Article in English | MEDLINE | ID: mdl-35416598

ABSTRACT

BACKGROUND: The purpose of this study was to evaluate the accuracy of intraoral scanners by comparing the trueness and precision of several types of scanners in measuring the distance between the ball abutments on pairs of multiple implants. METHODS: Seven implants were placed on a fully edentulous upper jaw model. After ball abutments were attached to the implants on the master model, the three-dimensional (3D) shape of the model was evaluated using a computer numerical control 3D coordinate-measuring machine. Subsequently, the 3D shape-related data of the model were obtained using two types of intraoral scanners (3M True Definition Scanner [TDS] and 3Shape Trios3 [TR3]) and two types of laboratory scanners (KaVo ARCTICA Auto Scan [KA] and Identica Hybrid [IH]). Using the obtained 3D shape-related data, the trueness and precision in measuring the distance between the balls within seven pairs of ball abutments were compared among the scanners using 3D analysis software. RESULTS: Intraoral scanners produced significantly greater errors in trueness and precision than laboratory scanners in measuring the distances between the ball abutments in all the dental regions. Between the intraoral scanners, powder-requiring TDS produced significantly lower errors at inflection points than powder-free TR3. CONCLUSIONS: These results indicate that an optical impression technique using an intraoral scanner is suitable for dental implant treatment in patients with a few missing teeth.


Subject(s)
Dental Implants , Jaw, Edentulous , Computer-Aided Design , Dental Impression Technique , Humans , Imaging, Three-Dimensional , Models, Dental
13.
Materials (Basel) ; 15(3)2022 Feb 02.
Article in English | MEDLINE | ID: mdl-35161098

ABSTRACT

Collagenous biomaterials that are clinically applied in dentistry have dermis-type and membrane-type, both of which are materials for promoting bone and soft tissue formation. The properties of materials supplied with different types could affect their biodegradation periods. The purpose of this study was to characterize five of these products by four different methods: scanning electron microscopy (SEM) observation, thermogravimetry-differential thermal analysis (TG-DTA), 0.01 wt% collagenase dissolution test, and subcutaneous implantation test in vivo. SEM micrographs revealed that both dermis and membranous materials were fibrous and porous. The membranous materials had higher specific derivative thermal gravimetry (DTG) peak temperatures in TG-DTA at around 320 °C, longer collagenase dissolution time ranging from about 300 to 500 min, and more longevity in mice exceeding 9 weeks than the dermis materials. There existed a correlation between the peak temperature in TG-DTA and the collagenase dissolution time. It was considered that higher cross-link degree among collagen fibrils of the membrane-type collagenous materials might account for these phenomena. The experimental protocol and numerical results obtained could be helpful for selection and future development of fibrous collagenous biomaterials in clinical use.

14.
Int J Mol Sci ; 22(15)2021 Jul 28.
Article in English | MEDLINE | ID: mdl-34360848

ABSTRACT

Titanium is often used in the medical field and in dental implants due to its biocompatibility, but it has a high rate of leading to peri-implantitis, which progresses faster than periodontitis. Therefore, in the present study, the expression of cytokines from gingival epithelial cells by nanotitania was investigated, which is derived from titanium in the oral cavity, and the additional effect of Porphyromonasgingivalis (periodontopathic bacteria) lipopolysaccharide (PgLPS) was investigated. Ca9-22 cells were used as a gingival epithelial cell model and were cultured with nanotitania alone or with PgLPS. Cytokine expression was examined by reverse transcription-quantitative polymerase chain reaction and enzyme-linked immunosorbent assay. In addition, cellular uptake of nanotitania was observed in scanning electron microscopy images. The expression of interleukin (IL)-6 and IL-8 significantly increased in Ca9-22 cells by nanotitania treatment alone, and the expression was further increased by the presence of PgLPS. Nanotitania was observed to phagocytose Ca9-22 cells in a dose- and time-dependent manner. Furthermore, when the expression of IL-11, related to bone resorption, was investigated, a significant increase was confirmed by stimulation with nanotitania alone. Therefore, nanotitania could be associated with the onset and exacerbation of peri-implantitis, and the presence of periodontal pathogens may worsen the condition. Further clinical reports are needed to confirm these preliminary results.


Subject(s)
Bacteroidaceae Infections/immunology , Epithelial Cells/immunology , Gingiva/immunology , Nanocomposites/adverse effects , Peri-Implantitis/immunology , Titanium/adverse effects , Cell Line , Cytokines/immunology , Epithelial Cells/cytology , Gingiva/cytology , Humans , Lipopolysaccharides/immunology , Peri-Implantitis/pathology , Porphyromonas gingivalis/immunology
15.
J Oral Sci ; 63(4): 301-305, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34408111

ABSTRACT

The recent literature on maxillary implant overdenture (IOD) was reviewed in order to clarify its predictability and establish treatment guidelines. Electronic searches were performed using PubMed, and articles about maxillary IOD written after 1990 were reviewed, focusing on the following items: I. implant survival rate, II. maxillary IOD survival rate, III. number of implants, IV. attachment type, V. follow-up period, VI. implant system, and VII. opposing dentition. The review revealed an implant survival rate of 61-100% and an overdenture survival rate of 72.4-100%. The attachments used included bars, balls, locators, and telescope crowns. The minimum and maximum observation periods were 12 months and 120 months, respectively, and the number of implants used for supporting IOD ranged from 2 to 8. At present, there is no strong evidence to indicate that maxillary IOD is clearly superior for all the items examined. However, the existing data indicate that maxillary IOD has almost the same therapeutic effect as fixed implant superstructures, and is a treatment option that can be actively adopted for patients in whom fixed superstructures cannot be applied for various reasons.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Denture Retention , Denture, Overlay , Humans , Maxilla
16.
J Oral Sci ; 63(3): 267-269, 2021 Jun 29.
Article in English | MEDLINE | ID: mdl-34135265

ABSTRACT

PURPOSE: The purpose of this study was to examine morphological changes in the superstructure of implants in relation to the degree of attrition of the implant superstructure and its antagonists. METHODS: Thirty-three patients participated. The implant superstructures of the first molar and its antagonists were scanned with an intraoral scanner every 3 months. The amount of attrition was calculated in relation to the various materials used for the superstructure, and differences were analyzed statistically (P < 0.05). RESULTS: Attrition of the implant superstructure was 110 ± 30 µm for monolithic zirconia and 105 ± 27 µm for resin-veneered metal after 12 months. No statistically significant difference was found between the two groups. In contrast, attrition of the antagonists was 75 ± 25 µm for zirconia and 105 ± 20 µm for resin-veneered metal after 12 months. A statistically significant difference in the attrition levels between the two groups was observed after 9 and 12 months. CONCLUSION: During the 12-month observation period, there was no difference in superstructure attrition between zirconia and resin-veneered metal. Attrition of the antagonists was higher for hybrid composite resin-veneered metal than for zirconia, suggesting that surface roughness affected the degree of attrition.


Subject(s)
Composite Resins , Dental Implants , Dental Porcelain , Dental Veneers , Humans , Materials Testing , Zirconium
17.
J Oral Sci ; 63(3): 212-216, 2021 Jun 29.
Article in English | MEDLINE | ID: mdl-34078769

ABSTRACT

This narrative review aims to provide an overview of recent studies and case reports on three-dimensional (3D) printing, and to verify the applicability of 3D printers in the field of dental prostheses. This review was performed by conducting a search of PubMed. The clinical application of fabricating a prosthesis made with cobalt-chromium is considered possible depending on the material and hardware of the 3D printer. However, it is currently difficult to assess the clinical use of 3D-printed zirconia crowns. Further research is required, such as verification of materials used, margin morphology, and hardware. Clinically acceptable results have been reported for patterns using 3D printers. Interim restorations made using a 3D printer have been reported with good results that are considered clinically usable. Dentures made with 3D printers need further verification in terms of strength and deformation. Custom trays made with 3D printers are clinically useful, however, issues remain with design time and effort. Although several studies have reported the usefulness of 3D printers, further verification is required since 3D printers are still considered new technology.


Subject(s)
Printing, Three-Dimensional , Prosthodontics , Crowns
18.
J Oral Sci ; 63(3): 263-266, 2021 Jun 29.
Article in English | MEDLINE | ID: mdl-34039830

ABSTRACT

PURPOSE: To determine the effects of titanium nanoparticles, that may have been scattered after dental implant placement, on gene and promoter expression, and gingival tissue. METHODS: Ca9-22 cell lines were used as gingival epithelial cells to assess the effects of titanium dioxide nanomaterials as titanium nanoparticles. Cells were cocultured with or without titanium dioxide nanomaterials prior to gene and promoter expression analysis. Expression of interleukin-13α2 receptor was investigated using real-time quantitative reverse-transcription polymerase chain reaction and immunofluorescence staining. Additionally, the enhanced messenger ribonucleic acid (mRNA) expression of transforming growth factor ß1 was analyzed using the same method. RESULTS: Titanium dioxide nanomaterials affected gene and promoter expression in Ca9-22 cells: among the 160 upregulated genes, the upregulation of IL13RA2, which encodes interleukin-13α2 receptor, was the highest (8.625 log2 fold change). Immunofluorescence staining confirmed the increased expression of interleukin-13α2 receptor, which enhanced transforming growth factor ß1 expression by stimulation with interleukin-13. CONCLUSION: Titanium dioxide nanomaterials applied on the gingival epithelium around the dental implant may increase interleukin-13α2 receptor expression. In turn, this can enhance the secretion of transforming growth factor ß1, which is known to promote the differentiation of osteoclasts involved in bone resorption, and potentially affect gingival tissue.


Subject(s)
Nanoparticles , Titanium , Gene Expression , Gingiva , Interleukins , Nanoparticles/toxicity , Titanium/toxicity
19.
J Prosthodont Res ; 65(4): 482-488, 2021 Oct 15.
Article in English | MEDLINE | ID: mdl-33762505

ABSTRACT

Purpose To reveal effects of improvement of masseter muscle activity on brain function in elderly people wearing complete dentures.Methods Subjects were 14 edentulous patients with a chief complaint of the inconvenience of their complete dentures. The surface electromyographic (EMG) activity of the masseter muscles was measured. Brain activities were analyzed with functional magnetic resonance imaging (fMRI), employing chewing gum as the task program. Cognitive functions were evaluated with Trail Making Test Part A (TMT-A), Rey Auditory Verbal Learning Test (RAVLT) and Rey-Osterrieth Complex Figure Test (R-OCFT). Those evaluations were performed in which subjects wore their old dentures (OD) or newly fabricated dentures (ND).Results We compared ND condition with OD condition. The masseter muscle activity significantly increased in ND condition (p < 0.05, Wilcoxon signed rank test). The brain activity increased significantly in the superior frontal gyrus, precentral gyrus, putamen, inferior parietal lobule, cerebellum, inferior frontal lobe, and middle frontal gyrus under the ND condition than under the OD condition (p < 0.01, uncorrected, cluster size > 10 voxels). Results of TMT-A, RAVLT, and R-OCFT were also significantly improved (p < 0.05, Wilcoxon signed rank test).Conclusions In the edentulous elderly, the brain activity was increased following the improvement of the masseter muscle activity. Consequently, it is possible that the improvement of the masseter muscle activity might influence on the attention, verbal skills, and visual memory.


Subject(s)
Masseter Muscle , Mouth, Edentulous , Aged , Brain/diagnostic imaging , Denture, Complete , Humans , Magnetic Resonance Imaging
20.
J Prosthodont ; 30(5): 458-461, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33533111

ABSTRACT

Various techniques have been applied to the fabrication of duplicate dentures. In this new method, after scanning the cameo and intaglio surfaces of the complete denture using an intraoral scanner, the two images were superimposed on the interocclusal image. The linear gap between cameo and intaglio surfaces was filled using free downloadable CAD software. The superimposed image was subsequently used as data for fabricating the duplicate complete denture with a 3D printer. Using the intraoral scanner, duplication of complete dentures could be performed without needing any complicated processes, laboratory scanners, or advanced CAD software.


Subject(s)
Computer-Aided Design , Denture Design , Denture, Complete , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...