Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Publication year range
1.
Strahlenther Onkol ; 197(9): 836-846, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34196725

ABSTRACT

PURPOSE: Dose, fractionation, normalization and the dose profile inside the target volume vary substantially in pulmonary stereotactic body radiotherapy (SBRT) between different institutions and SBRT technologies. Published planning studies have shown large variations of the mean dose in planning target volume (PTV) and gross tumor volume (GTV) or internal target volume (ITV) when dose prescription is performed to the PTV covering isodose. This planning study investigated whether dose prescription to the mean dose of the ITV improves consistency in pulmonary SBRT dose distributions. MATERIALS AND METHODS: This was a multi-institutional planning study by the German Society of Radiation Oncology (DEGRO) working group Radiosurgery and Stereotactic Radiotherapy. CT images and structures of ITV, PTV and all relevant organs at risk (OAR) for two patients with early stage non-small cell lung cancer (NSCLC) were distributed to all participating institutions. Each institute created a treatment plan with the technique commonly used in the institute for lung SBRT. The specified dose fractionation was 3â€¯× 21.5 Gy normalized to the mean ITV dose. Additional dose objectives for target volumes and OAR were provided. RESULTS: In all, 52 plans from 25 institutions were included in this analysis: 8 robotic radiosurgery (RRS), 34 intensity-modulated (MOD), and 10 3D-conformal (3D) radiation therapy plans. The distribution of the mean dose in the PTV did not differ significantly between the two patients (median 56.9 Gy vs 56.6 Gy). There was only a small difference between the techniques, with RRS having the lowest mean PTV dose with a median of 55.9 Gy followed by MOD plans with 56.7 Gy and 3D plans with 57.4 Gy having the highest. For the different organs at risk no significant difference between the techniques could be found. CONCLUSIONS: This planning study pointed out that multiparameter dose prescription including normalization on the mean ITV dose in combination with detailed objectives for the PTV and ITV achieve consistent dose distributions for peripheral lung tumors in combination with an ITV concept between different delivery techniques and across institutions.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Radiosurgery , Radiotherapy, Intensity-Modulated , Carcinoma, Non-Small-Cell Lung/pathology , Humans , Lung/pathology , Lung Neoplasms/pathology , Prescriptions , Radiosurgery/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
2.
Zentralbl Chir ; 140(1): 83-93, 2015 Feb.
Article in German | MEDLINE | ID: mdl-25723755

ABSTRACT

Radiooncological therapies are an integral part of the multimodal oncological treatment concepts in general and abdominal surgery. These include therapeutic approaches with a curative intention such as the neoadjuvant (pre-operative) radiotherapy of locoregionally advanced and/or N+ oesophageal and rectal cancer, definitive combined chemoradiotherapy of locally advanced, unresectable oesophageal cancer or oesophageal tumour lesions of the upper third, definitive radiotherapy of anal cancer (sphincter sparing) and pre- or post-operative radiotherapy of soft tissue sarcoma on the one hand. A yT0 stage achieved as characteristic of a curative effect by radiation in oesophageal and rectal cancer (omitting subsequent surgical intervention, naturally under clinical and imaging-based controls within short-term follow-up intervals) can be considered as a very interesting set-up with regard to its reasonable integration in daily clinical practice, which needs to be further and critically discussed. By integrating radiotherapy in interdisciplinary therapy concepts, improved tumour control and survival rates with clinically acceptable toxicity can be achieved. On the other hand, non-invasive, locally ablative radiooncological therapies such as extracranial stereotactic body radiotherapy constitute an effective and feasible treatment method for liver metastases in oligometastatic colorectal cancer or other tumour entities according to the decisions by the institutional tumour board, offering high local tumour control rates which can be part of multistep, multimodal procedures with curative intention. This review aims at providing an overview for the general and abdominal surgeon, outlining relevant radiooncological treatment aspects in the multimodal cancer therapy with a focus on the treatment of rectal, oesophageal and anal cancer as well as soft tissue sarcoma and hepatic metastases in oligometastatic colorectal cancer.


Subject(s)
Abdomen/surgery , General Surgery/education , Radiotherapy , Specialties, Surgical/education , Clinical Competence , Combined Modality Therapy , Cooperative Behavior , Curriculum , Gastrointestinal Neoplasms/therapy , Germany , Humans , Interdisciplinary Communication
3.
Physiol Meas ; 14 Suppl 4A: A45-50, 1993 Nov.
Article in English | MEDLINE | ID: mdl-8274984

ABSTRACT

We describe a 28-channel magnetometer that operates as a 22-channel 'software gradiometer'. Gradiometer function is achieved by subtraction of weighted signals representing the noise field along three orthogonal axes as detected by six compensation channels. The instrument measures both normal and tangential field components; the user can select a total of 22 normal and/or tangential measuring sites from two arrays of 16 sites each. First experiences indicate that the combination of a shielded room with a software suppression of the residual field entering the room is amply sufficient to allow biomagnetic measurements in a hospital environment.


Subject(s)
Brain Mapping/methods , Magnetoencephalography/instrumentation , Software , Humans , Magnetoencephalography/methods
4.
Clin Chim Acta ; 197(3): 189-200, 1991 Mar 29.
Article in English | MEDLINE | ID: mdl-2049861

ABSTRACT

The stability of the aminoacids in human blood serum ultrafiltrates and in an aminoacid standard solution was investigated under different pH and storage conditions. At close to neutral pH values the aminoacid concentrations remained constant for at least 12 months at -50 degrees C (n = 6), except for lysine. With acid but particularly with alkaline conditions a time- and temperature-dependent decrease was observed for glutamine and asparagine with concomitant increases of glutamate and aspartate. Similar, but less prominent alterations were noted for the concentrations of methionine, glycine, tyrosine, histidine, arginine and ornithine. Almost independent of pH, there was an effect of temperature; after 24 h at 55 degrees C a significant increase of several per cent in a number of serum aminoacid concentrations was observed, presumably due to the hydrolysis of small proteins and peptides. For the purpose of aminoacid analysis it is recommended that samples be stored deproteinized, deep-frozen and at neutral pH.


Subject(s)
Amino Acids/blood , Adult , Amino Acids/analysis , Blood Proteins , Chromatography , Freezing , Humans , Hydrochloric Acid , Hydrogen-Ion Concentration , Reference Values , Sodium Hydroxide , Temperature , Time Factors , Ultrafiltration
5.
Clin Phys Physiol Meas ; 12 Suppl A: 55-9, 1991.
Article in English | MEDLINE | ID: mdl-1778055

ABSTRACT

Because of the way most available hardware gradiometers are designed and in view of the prediction, by theory, that the normal magnetic field component provides all available information on the intrinsic current source, MEG and MCG measurements generally consider only the field vector normal to the head or truck surface. However, when looking for single events, the information contained in the normal component often cannot be fully sampled, because the sensor array has limited dimensions and therefore covers only a fraction of the field's spatial extension. Simulation of a current dipole in a sphere using realistic parameters shows that there is a considerable area where the amplitude of the tangential field components is larger than that of the normal one. Measurements using a 28-channel magnetometer system with normal and tangential pick-up coils and a current dipole in a phantom model confirm this prediction; depending on dipole orientation, the signal-to-noise ratio (SNR) could improve by a factor of up to 20 if the total field was considered instead of only the normal component. MCG recordings with the same instrument demonstrated a broad area above the heart where the tangential SNR was clearly better than the normal one. Preliminary measurements indicate that tangential components can also be recorded in the MEG; it is suggested that they may help source localisation.


Subject(s)
Brain/physiology , Heart Function Tests/methods , Heart/physiology , Magnetics , Magnetoencephalography/methods , Humans , Models, Cardiovascular , Models, Neurological , Reference Values
SELECTION OF CITATIONS
SEARCH DETAIL