1.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599692

ABSTRACT

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Follow-Up Studies , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects
2.
Eur J Heart Fail ; 26(4): 1065-1077, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38606485

ABSTRACT

AIMS: Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. METHODS AND RESULTS: Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was -5.7 (-8.6, -2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I-II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20-30) and 27 (22-32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. CONCLUSIONS: In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.


Subject(s)
Coronary Sinus , Feasibility Studies , Heart Atria , Heart Failure , Stroke Volume , Humans , Heart Failure/physiopathology , Heart Failure/surgery , Heart Failure/therapy , Female , Male , Stroke Volume/physiology , Aged , Heart Atria/physiopathology , Heart Atria/diagnostic imaging , Coronary Sinus/physiopathology , Treatment Outcome , Middle Aged , Echocardiography/methods , Quality of Life , Cardiac Catheterization/methods , Prospective Studies , Ventricular Function, Left/physiology , Follow-Up Studies , Hemodynamics/physiology
3.
JTCVS Open ; 17: 55-63, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38420551

ABSTRACT

Background: The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory-adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods: TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory-adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results: The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm2, respectively. Paravalvular leak at 7 years was none/trace in 88.6% and mild in 11.4%. In patients undergoing isolated AVR, the cumulative probability of pacemaker implantation was 13.9% at 30 days, 15.5% at 1 year, and 21.8% at 7 years. Conclusions: AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.

4.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Article in English | MEDLINE | ID: mdl-38099912

ABSTRACT

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Predictive Value of Tests , Recovery of Function , Severity of Illness Index , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Male , Female , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Treatment Outcome , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Aged , Risk Factors , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Time Factors , Aged, 80 and over , Heart Valve Prosthesis , Feasibility Studies , Risk Assessment , Prosthesis Design , Echocardiography, Three-Dimensional
5.
Article in English | MEDLINE | ID: mdl-37962288

ABSTRACT

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

6.
JACC Cardiovasc Interv ; 16(23): 2820-2832, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37905772

ABSTRACT

BACKGROUND: Favorable 6-month outcomes from the CLASP IID Registry (Edwards PASCAL transcatheter valve repair system pivotal clinical trial) demonstrated that mitral valve transcatheter edge-to-edge repair with the PASCAL transcatheter valve repair system is safe and beneficial for treating prohibitive surgical risk degenerative mitral regurgitation (DMR) patients with complex mitral valve anatomy. OBJECTIVES: The authors sought to assess 1-year safety, echocardiographic and clinical outcomes from the CLASP IID Registry. METHODS: Patients with 3+ or 4+ DMR who were at prohibitive surgical risk, had complex mitral valve anatomy based on the MitraClip Instructions for Use, and deemed suitable for treatment with the PASCAL system were enrolled prospectively. Safety, clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. Study oversight included a central screening committee, echocardiographic core laboratory, and clinical events committee. RESULTS: Ninety-eight patients were enrolled. One-year Kaplan-Meier (KM) estimates of freedom from composite major adverse events, all-cause mortality, and heart failure hospitalization were 83.5%, 89.3%, and 91.5%, respectively. Significant mitral regurgitation (MR) reduction was achieved at 1 year (P < 0.001 vs baseline) including 93.2% at MR ≤2+ and 57.6% at MR ≤1+ with improvements in related echocardiographic measures. NYHA functional class and Kansas City Cardiomyopathy Questionnaire score also improved significantly (P < 0.001 vs baseline). CONCLUSIONS: At 1 year, treatment with the PASCAL system demonstrated safety and significant MR reduction, with continued improvement in clinical, echocardiographic, functional, and quality-of-life outcomes, illustrating the value of the PASCAL system in the treatment of prohibitive surgical risk patients with 3+ or 4+ DMR and complex mitral valve anatomy.


Subject(s)
Cardiac Catheterization , Mitral Valve Insufficiency , Humans , Cardiac Catheterization/adverse effects , Echocardiography , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Treatment Outcome , Clinical Trials as Topic
7.
J Am Coll Cardiol ; 82(22): 2101-2109, 2023 11 28.
Article in English | MEDLINE | ID: mdl-37877909

ABSTRACT

BACKGROUND: The American College of Cardiology/American Heart Association guidelines recommend the assessment and grading of severity of aortic stenosis (AS) as mild, moderate, or severe, per echocardiogram, and recommend aortic valve replacement (AVR) when the AS is severe. OBJECTIVES: The authors sought to describe mortality rates across the entire spectrum of untreated AS from a contemporary, large, real-world database. METHODS: We analyzed a deidentified real-world data set including 1,669,536 echocardiographic reports (1,085,850 patients) from 24 U.S. hospitals (egnite Database, egnite). Patients >18 years of age were classified by diagnosed AS severity. Untreated mortality and treatment rates were examined with Kaplan-Meier (KM) estimates, with results compared using the log-rank test. Multivariate hazards analysis was performed to assess associations with all-cause mortality. RESULTS: Among 595,120 patients with available AS severity assessment, the KM-estimated 4-year unadjusted, untreated, all-cause mortality associated with AS diagnosis of none, mild, mild-to-moderate, moderate, moderate-to-severe, or severe was 13.5% (95% CI: 13.3%-13.7%), 25.0% (95% CI: 23.8%-26.1%), 29.7% (95% CI: 26.8%-32.5%), 33.5% (95% CI: 31.0%-35.8%), 45.7% (95% CI: 37.4%-52.8%), and 44.9% (95% CI: 39.9%-49.6%), respectively. Results were similar when adjusted for informative censoring caused by treatment. KM-estimated 4-year observed treatment rates were 0.2% (95% CI: 0.2%-0.2%), 1.0% (95% CI: 0.7%-1.3%), 4.2% (95% CI: 2.0%-6.3%), 11.4% (95% CI: 9.5%-13.3%), 36.7% (95% CI: 31.8%-41.2%), and 60.7% (95% CI: 58.0%-63.3%), respectively. After adjustment, all degrees of AS severity were associated with increased mortality. CONCLUSIONS: Patients with AS have high mortality risk across all levels of untreated AS severity. Aortic valve replacement rates remain low for patients with severe AS, suggesting that more research is needed to understand barriers to diagnosis and appropriate approach and timing for aortic valve replacement.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Treatment Outcome , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Echocardiography , Severity of Illness Index , Risk Factors
8.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37584233

ABSTRACT

AIMS: Incomplete left atrial appendage occlusion (LAAO) due to peri-device leak (PDL) is a limitation of the therapy. The Amulet IDE trial is the largest randomized head-to-head trial comparing the Amulet and Watchman 2.5 LAAO devices with fundamentally different designs. The predictors and mechanistic factors impacting differences in PDLs within the Amulet IDE trial are assessed in the current analysis. METHODS AND RESULTS: An independent core lab analysed all images for the presence or absence of severe PDL (>5 mm). The incidence, mechanistic factors, predictors using propensity score-matched controls, and evolution of severe PDLs through 18 months were assessed. Of the 1878 patients randomized in the trial, the Amulet occluder had significantly fewer severe PDLs than the Watchman device at 45 days (1.1 vs. 3.2%, P < 0.001) and 12 months (0.1 vs. 1.1%, P < 0.001). Off-axis deployment or missed lobes were leading mechanistic PDL factors in each device group. Larger left atrial appendage (LAA) dimensions including orifice diameter, landing zone diameter, and depth predicted severe PDL with the Watchman device, with no significant anatomical limitations noted with the Amulet occluder. Procedural and device implant predictors were found with the Amulet occluder attributed to the learning curve with the device. A majority of Watchman device severe PDLs did not resolve over time through 18 months. CONCLUSION: The dual-occlusive Amplatzer Amulet LAA occluder provided improved LAA closure compared with the Watchman 2.5 device. Predictors and temporal observations of severe PDLs were identified in the Amulet IDE trial. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov Unique identifier NCT02879448.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Septal Occluder Device , Stroke , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Cardiac Surgical Procedures/adverse effects , Treatment Outcome , Septal Occluder Device/adverse effects , Cardiac Catheterization/adverse effects , Stroke/etiology
9.
JACC Cardiovasc Interv ; 16(11): 1369-1380, 2023 06 12.
Article in English | MEDLINE | ID: mdl-36989271

ABSTRACT

BACKGROUND: Heart failure (HF) is associated with both mortality and a significant decline in health status. Interatrial shunting is increasingly being investigated as a novel therapeutic option. OBJECTIVES: The ALT FLOW Early Feasibility Study was designed to evaluate the safety of the Edwards left atrial to coronary sinus APTURE Transcatheter Shunt System in patients with symptomatic HF. METHODS: A total of 18 centers enrolled patients with symptomatic HF with a pulmonary capillary wedge pressure >15 mm Hg at rest or 25 mm Hg during exercise. RESULTS: Between May 2018 and September 2022, 87 patients underwent attempted APTURE shunt implantation. Mean age was 71 years, and 53% were male. At baseline, mean left ventricular ejection fraction was 59% with 90% of the patients being in NYHA functional class III. Device success was achieved in 78 patients (90%), with no device occlusions or associated adverse events identified after implantation. The primary safety outcome occurred in only 2 patients (2.3%) at 30 days. At 6 months, health status improved: 67% of participants achieved NYHA functional class I to II status, with a 23-point improvement (P < 0.0001; 95% CI: 17-29 points) in the Kansas City Cardiomyopathy Questionnaire overall summary score. Also at 6 months, 20-W exercise pulmonary capillary wedge pressure was 7 mm Hg lower (P < 0.0001; 95% CI: -11 to -4 mm Hg) without change in right atrial pressure or other right heart function indices. CONCLUSIONS: In this single-arm experience, the APTURE Transcatheter Shunt System in patients with symptomatic HF was observed to be safe and resulted in reduction in pulmonary capillary wedge pressure and clinically meaningful improvements in HF symptoms and quality of life indices.


Subject(s)
Atrial Fibrillation , Coronary Sinus , Heart Failure , Humans , Male , Aged , Female , Stroke Volume , Ventricular Function, Left , Coronary Sinus/diagnostic imaging , Quality of Life , Cardiac Catheterization , Treatment Outcome , Heart Failure/diagnostic imaging , Heart Failure/therapy , Heart Failure/etiology
10.
J Am Coll Cardiol ; 81(5): 431-442, 2023 02 07.
Article in English | MEDLINE | ID: mdl-36725171

ABSTRACT

BACKGROUND: Mitral valve transcatheter edge-to-edge repair is safe and effective in treating degenerative mitral regurgitation (DMR) patients at prohibitive surgical risk, but outcomes in complex mitral valve anatomy patients vary. OBJECTIVES: The PASCAL IID registry assessed safety, echocardiographic, and clinical outcomes with the PASCAL system in prohibitive risk patients with significant symptomatic DMR and complex mitral valve anatomy. METHODS: Patients in the prospective, multicenter, single-arm registry had 3+ or 4+ DMR, were at prohibitive surgical risk, presented with complex anatomic features based on the MitraClip instructions for use, and were deemed suitable for the PASCAL system by a central screening committee. Enrolled patients were treated with the PASCAL system. Safety, effectiveness, and functional and quality-of-life outcomes were assessed. Study oversight also included an echocardiographic core laboratory and clinical events committee. RESULTS: The study enrolled 98 patients (37.2% ≥2 independent significant jets, 15.0% severe bileaflet/multi scallop prolapse, 13.3% mitral valve orifice area <4.0 cm2, and 10.6% large flail gap and/or large flail width). The implant success rate was 92.9%. The 30-day composite major adverse event rate was 11.2%. At 6 months, 92.4% patients achieved MR ≤2+ and 56.1% achieved MR ≤1+ (P < 0.001 vs baseline). The Kaplan-Meier estimates for survival, freedom from major adverse events, and heart failure hospitalization at 6 months were 93.7%, 85.6%, and 92.6%, respectively. Patients experienced significant symptomatic improvement compared with baseline (P < 0.001). CONCLUSIONS: The outcomes of the PASCAL IID registry establish the PASCAL system as a useful therapy for prohibitive surgical risk DMR patients with complex mitral valve anatomy. (PASCAL IID Registry within the Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID] NCT03706833).


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Prospective Studies , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Cardiac Catheterization/adverse effects
11.
JACC Clin Electrophysiol ; 9(1): 96-107, 2023 01.
Article in English | MEDLINE | ID: mdl-36697204

ABSTRACT

BACKGROUND: Device-related thrombus (DRT) following left atrial appendage occlusion (LAAO) can lead to adverse clinical outcomes. DRT rates and outcomes from randomized trials are limited. OBJECTIVES: This analysis investigated the incidence, predictors, and clinical outcomes of DRT following LAAO in the Amulet IDE (AMPLATZER Amulet LAA Occluder Trial) trial. METHODS: Successful implants occurred in 903 patients with an Amulet occluder (dual occlusive mechanism device) and 885 patients with a Watchman device (single occlusive mechanism device). These patients were then followed through 18 months and DRT was assessed by transesophageal echocardiography. RESULTS: The overall incidence of DRT was 3.9% (n = 70) with 3.4% (n = 30) in dual occlusive mechanism device patients and 4.8% (n = 40) in single occlusive mechanism device patients. Most DRTs (n = 19 of 31) were identified early (≤45 days) on the dual occlusive mechanism device, whereas most of the DRTs (n = 31 of 42) were identified late (>45 days) on the single occlusive mechanism device. Strong predictors of DRT included atrial fibrillation at time of procedure (HR: 2.44; 95% CI: 1.42-4.22; P < 0.01), female sex (HR: 1.65; 95% CI: 1.01-2.71; P = 0.04), and older age (HR: 1.04; 95% CI: 1.01-1.08; P = 0.02). There were no stroke events following DRT in the dual occlusive mechanism device group and 3 stroke events following DRT in the single occlusive mechanism device group. Patients with DRT were at a greater risk for cardiovascular mortality compared with non-DRT patients (8.7% vs 3.9%; HR: 2.33; 95% CI: 1.01-5.39; P = 0.04). CONCLUSIONS: Incidence of DRT following LAAO was low. Early DRTs are seen with the dual occlusive mechanism device and late DRTs are seen with the single occlusive mechanism device. Increased cardiovascular mortality risk in patients with DRT should be further investigated. (AMPLATZER Amulet LAA Occluder Trial; NCT02879448).


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thrombosis , Female , Humans , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Incidence , Stroke/epidemiology , Thrombosis/epidemiology , Thrombosis/etiology
12.
JACC Cardiovasc Interv ; 15(21): 2127-2138, 2022 11 14.
Article in English | MEDLINE | ID: mdl-36357016

ABSTRACT

BACKGROUND: Peridevice leak (PDL) is a limitation of left atrial appendage occlusion. OBJECTIVES: The aim of this study was to assess the incidence of and outcomes associated with PDL in the Amulet IDE (AMPLATZER™ Amulet™ LAA Occluder Trial) randomized controlled trial. METHODS: Patients with atrial fibrillation at increased stroke risk were randomly assigned to undergo either Amulet (dual occlusive mechanism) or Watchman 2.5 (single occlusive mechanism) device implantation. Transesophageal echocardiography was performed at 45 days and 12 months postprocedure. Clinically significant PDL was defined as ≥3 mm. The primary endpoint was ischemic stroke or systemic embolism, and the secondary endpoint was stroke, systemic embolism, or cardiovascular death. The Kaplan-Meier method was used to estimate 18-month cumulative event rates landmarked at day 45 postprocedure. RESULTS: A total of 1,593 patients underwent successful left atrial appendage occlusion and had an evaluable transesophageal echocardiographic studies at 45 days. The dual-occlusive mechanism device provided superior closure (defined as leak <3 mm) compared with the single-occlusive mechanism device at 45 days (88.9% vs 74.1%; P < 0.01) and 12 months (90.5% vs. 78.3%; P < 0.01). Through 18 months, PDL was associated with a higher, but not statistically significant, risk for the primary endpoint (3.6% vs 1.8%; adjusted HR: 1.98; 95% CI: 0.93-4.19; P = 0.07) and a statistically significantly higher risk for the secondary endpoint (8.1% vs. 4.7%; adjusted HR: 1.66; 95% CI: 1.02-2.69; P = 0.04). CONCLUSIONS: The dual-occlusive mechanism device provided superior closure compared with the single-occlusive mechanism device at both 45 days and 1 year postprocedure. PDL ≥3 mm was associated with a significantly increased 18-month risk for the composite of stroke, systemic embolism, or cardiovascular death. Completeness of closure of the left atrial appendage has important implications for patient outcomes. (AMPLATZER™ Amulet™ LAA Occluder Trial [Amulet IDE]; NCT02879448).


Subject(s)
Atrial Appendage , Atrial Fibrillation , Embolism , Septal Occluder Device , Stroke , Humans , Atrial Appendage/diagnostic imaging , Treatment Outcome , Atrial Fibrillation/complications , Atrial Fibrillation/therapy , Echocardiography, Transesophageal/adverse effects , Stroke/etiology , Stroke/prevention & control , Embolism/etiology , Cardiac Catheterization , Septal Occluder Device/adverse effects
13.
JACC Cardiovasc Interv ; 15(19): 1921-1932, 2022 10 10.
Article in English | MEDLINE | ID: mdl-36202561

ABSTRACT

BACKGROUND: Tricuspid regurgitation (TR) is prevalent and undertreated, with mortality and morbidity increasing with TR severity. Given poor outcomes with medical therapy and high in-hospital mortality for isolated tricuspid valve surgery, emerging transcatheter repair devices offer a promising alternative. OBJECTIVES: The Edwards Cardioband Tricuspid Valve Reconstruction System Early Feasibility study (NCT03382457) evaluates the treatment of functional TR via annular reduction with the Cardioband Tricuspid Valve Reconstruction System (Edwards Lifesciences). METHODS: Patients with ≥ moderate functional TR were eligible for this prospective, single-arm multicenter study. At 1 year, patients were evaluated for echocardiographic parameters, clinical and quality-of-life measures, and major adverse events. RESULTS: The 37 patients enrolled had a mean age of 78 years; 76% were female; and they had ≥ severe functional (97.3%) or mixed (2.7%) TR, atrial flutter/fibrillation (97%), and New York Heart Association functional class III/IV (65%). At 1 year, 73.0% achieved ≤ moderate TR (P < 0.0001), and 73.1% had ≥2 grade reductions. Echocardiography showed significant reductions in the tricuspid annulus diameter (P < 0.0001), mean vena contracta (P < 0.0001), proximal isovelocity surface area effective regurgitant orifice area (P < 0.0001), right ventricular end-diastolic diameter (P < 0.0001), and inferior vena contracta (P = 0.0006). New York Heart Association functional class improved significantly (P < 0.0001), with 92.3% achieving class I/II, and Kansas City Cardiomyopathy Questionnaire scores improved by 19.0 points (P < 0.0001). One-year cardiovascular mortality was 8.1%, reinterventions were necessary in 5.4%, major access site complications occurred in 8.1%, and severe bleeding was noted in 35.1% of patients. Kaplan-Meier estimates of survival and freedom from heart failure rehospitalization were 85.9% and 88.7%, respectively. CONCLUSIONS: One-year experience using the Cardioband system for tricuspid valve repair shows high survival and low rehospitalization rates with durable outcomes in TR reduction and echocardiographic, clinical, and quality-of-life outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Aged , Cardiac Catheterization , Feasibility Studies , Female , Humans , Male , Prospective Studies , Severity of Illness Index , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery
14.
JACC Cardiovasc Interv ; 15(24): 2523-2536, 2022 12 26.
Article in English | MEDLINE | ID: mdl-36121247

ABSTRACT

BACKGROUND: Severe symptomatic degenerative mitral regurgitation (DMR) has a poor prognosis in the absence of treatment, and new transcatheter options are emerging. OBJECTIVES: The CLASP IID (Edwards PASCAL Transcatheter Valve Repair System Pivotal Clinical Trial) randomized trial (NCT03706833) is the first to evaluate the safety and effectiveness of the PASCAL system compared with the MitraClip system in patients with significant symptomatic DMR. This report presents the primary safety and effectiveness endpoints for the trial. METHODS: Patients with 3+ or 4+ DMR at prohibitive surgical risk were assessed by a central screening committee and randomized 2:1 (PASCAL:MitraClip). Study oversight also included an echocardiography core laboratory and a clinical events committee. The primary safety endpoint was the composite major adverse event rate at 30 days. The primary effectiveness endpoint was the proportion of patients with mitral regurgitation (MR) ≤2+ at 6 months. RESULTS: A prespecified interim analysis in 180 patients demonstrated noninferiority of the PASCAL system vs the MitraClip system for the primary safety and effectiveness endpoints of major adverse event rate (3.4% vs 4.8%) and MR ≤2+ (96.5% vs 96.8%), respectively. Functional and quality-of-life outcomes significantly improved in both groups (P < 0.05). The proportion of patients with MR ≤1+ was durable in the PASCAL group from discharge to 6 months (PASCAL, 87.2% and 83.7% [P = 0.317 vs discharge]; MitraClip, 88.5% and 71.2% [P = 0.003 vs discharge]). CONCLUSIONS: The CLASP IID trial demonstrated safety and effectiveness of the PASCAL system and met noninferiority endpoints, expanding transcatheter treatment options for prohibitive surgical risk patients with significant symptomatic DMR.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Treatment Outcome
15.
JACC Cardiovasc Imaging ; 15(5): 747-760, 2022 05.
Article in English | MEDLINE | ID: mdl-35324429

ABSTRACT

OBJECTIVES: The purpose of this study was to compare the American Society of Echocardiography (ASE) algorithm for assessing mitral regurgitation (MR) to cardiac magnetic resonance (CMR) and left ventricular (LV) remodeling following mitral intervention. BACKGROUND: The ASE recommends integrating multiple echocardiographic parameters for assessing MR. The ASE guidelines include an algorithm that weighs the parameters and highlights those considered indicative of definitely mild or definitely severe MR. METHODS: We prospectively enrolled 152 (age 62 ± 13 years; 59% male) patients with degenerative MR who underwent ASE algorithm-guided echocardiographic and CMR grading of MR severity. Using the ASE algorithm, patients were graded as definitely mild, grade I, grade II, grade III, grade IV, or definitely severe MR. CMR MR volume was graded as mild (<30 mL), grade II moderate (30-44 mL), grade III moderate (45-59 mL), or severe (≥60 mL). A subgroup of 63 patients underwent successful mitral intervention, of whom 48 had postintervention CMR. RESULTS: Only 52% of patients with definitely severe MR by the ASE algorithm had severe MR by CMR, and 10% had mild MR by CMR. There was an increase in post mitral intervention LV reverse remodeling with worsening MR severity using CMR (P < 0.0001) but not the ASE algorithm (P = 0.07). Severe MR by CMR was an independent predictor of post mitral intervention LV reverse remodeling and definitely severe MR by the ASE algorithm was not. CONCLUSIONS: In patients with degenerative MR, agreement between CMR and the ASE algorithm was suboptimal. Severe MR by CMR was an independent predictor of post mitral intervention LV reverse remodeling, whereas definitely severe MR by the ASE algorithm was not. These findings suggest an important role for CMR in surgical decision making in degenerative MR. (Comparison Study of Echocardiography and Cardiovascular Magnetic Resonance Imaging in the Assessment of Mitral and Aortic Regurgitation; NCT04038879).


Subject(s)
Mitral Valve Insufficiency , Aged , Algorithms , Echocardiography , Female , Humans , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Male , Middle Aged , Predictive Value of Tests , Severity of Illness Index , United States , Ventricular Remodeling
16.
Struct Heart ; 6(4): 100071, 2022 Aug.
Article in English | MEDLINE | ID: mdl-37288338

ABSTRACT

Patients with severe symptomatic tricuspid regurgitation face a significant dilemma in treatment options, as the yearly mortality with medical therapy and the surgical mortality for tricuspid repair or replacement are high. Transcatheter edge-to-edge repair (TEER) for the tricuspid valve is becoming a viable option in patients, although procedural success is dependent on high-quality imaging. While transesophageal echocardiography remains the standard for tricuspid TEER procedures, intracardiac echocardiography (ICE) with three-dimensional (3D) multiplanar reconstruction (MPR) has many theoretical and practical advantages. The aim of this article was to describe the in vitro wet lab-based imaging work done to facilitate the best approach to 3D MPR ICE imaging and the procedural experience gained with 3D MPR ICE in tricuspid TEER procedures with the PASCAL device.

18.
J Am Coll Cardiol ; 78(25): 2537-2546, 2021 12 21.
Article in English | MEDLINE | ID: mdl-34915984

ABSTRACT

BACKGROUND: Echocardiography guidelines note that a flail leaflet is a specific criterion for severe mitral regurgitation (MR) and that regurgitant severity is underestimated in wall-impinging jets (Coanda effect). Both findings are often considered to be pathognomonic of severe MR. OBJECTIVES: In this study, the authors sought to determine the association of flail leaflet and Coanda effect with MR severity quantified by means of cardiac magnetic resonance (CMR). METHODS: The authors enrolled 158 consecutive patients with primary MR according to echocardiography and CMR. The presence of a flail leaflet or Coanda was determined for each patient. CMR regurgitant volume (RV) and regurgitant fraction (RF) were quantified for all patients. RESULTS: There were 55 patients (35%) with a flail leaflet, 52 (33%) with Coanda, and 22 (14%) with a flail leaflet and Coanda. The mean CMR mitral RV and RF progressively increased in patients without a Coanda or flail, a Coanda, a flail, or a Coanda and a flail (RV: 28 ± 21 mL vs 43 ± 23 mL vs 58 ± 29 mL vs 64 ± 25 mL [P < 0.001]; RF: 25% ± 16% vs 34% ± 14% vs 41% ± 12% vs 45% ± 12% [P < 0.001]). With the use of CMR RV, 35%, 46%, and 59% of patients had severe MR with the presence of a Coanda, flail leaflet, or both, respectively. With the use of CMR RF, 25%, 31%, and 40% of patients had severe MR with the presence of a Coanda, flail leaflet, or both, respectively. CONCLUSIONS: While the presence of a flail leaflet and Coanda effect on echocardiography are associated with higher regurgitant volumes and fractions, they are frequently not associated with severe MR as assessed by means of CMR. (Comparison Study of Echocardiography and Cardiovascular Magnetic Resonance Imaging in the Assessment of Mitral and Aortic Regurgitation; NCT04038879).


Subject(s)
Cardiac Imaging Techniques , Magnetic Resonance Imaging , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve/diagnostic imaging , Aged , Algorithms , Echocardiography , Female , Humans , Male , Middle Aged , Prospective Studies , Severity of Illness Index
19.
Catheter Cardiovasc Interv ; 98(4): E637-E646, 2021 10.
Article in English | MEDLINE | ID: mdl-34004077

ABSTRACT

OBJECTIVES: We report the 30-day outcomes from the roll-in cohort of the CLASP IID trial, representing the first procedures performed by each site. BACKGROUND: The currently enrolling CLASP IID/IIF pivotal trial is a multicenter, prospective, randomized trial assessing the safety and effectiveness of the PASCAL transcatheter valve repair system in patients with clinically significant MR. The trial allows for up to three roll-in patients per site. METHODS: Eligibility criteria were: DMR ≥3+, prohibitive surgical risk, and deemed suitable for transcatheter repair by the local heart team. Trial oversight included a central screening committee and echocardiographic core laboratory. The primary safety endpoint was a 30-day composite MAE: cardiovascular mortality, stroke, myocardial infarction (MI), new need for renal replacement therapy, severe bleeding, and non-elective mitral valve re-intervention, adjudicated by an independent clinical events committee. Thirty-day echocardiographic, functional, and quality of life outcomes were assessed. RESULTS: A total of 45 roll-in patients with mean age of 83 years and 69% in NYHA class III/IV were treated. Successful implantation was achieved in 100%. The 30-day composite MAE rate was 8.9% including one cardiovascular death (2.2%) due to severe bleeding from a hemorrhagic stroke, one MI, and no need for re-intervention. MR≤1+ was achieved in 73% and ≤2+ in 98% of patients. 89% of patients were in NYHA class I/II (p < .001) with improvements in 6MWD (30 m; p = .054) and KCCQ (17 points; p < .001). CONCLUSIONS: Early results representing sites with first experience with the PASCAL repair system showed favorable 30-day outcomes in patients with DMR≥3+ at prohibitive surgical risk.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged, 80 and over , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Prospective Studies , Quality of Life , Treatment Outcome