Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Med Case Rep ; 18(1): 263, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38807243

ABSTRACT

BACKGROUND: Pneumomediastinum and pneumorrachis are rare complications following epidural analgesia, that can either be asymptomatic or rarely can produce mild to moderate severity symptoms. Most reported cases regarding the presentation of these two entities with epidural analgesia concern asymptomatic patients, however there are cases reporting post-dural puncture headache and respiratory manifestations. CASE PRESENTATION: We present a case where a combined lumbar epidural and spinal anesthesia was performed using the loss of resistance to air technique (LOR), on a 78-year-old Greek (Caucasian) male undergoing a total hip replacement. Despite being hemodynamically stable throughout the operation, two hours following epidural analgesia the patient manifested a sudden drop in blood pressure and heart rate that required the administration of adrenaline to counter. Pneumomediastinum, pneumorrachis and paravertebral soft tissue emphysema were demonstrated in a Computed Tomography scan. We believe that injected air from the epidural space and surrounding tissues slowly moved towards the mediastinum, stimulating the para-aortic ganglia causing parasympathetic stimulation and therefore hypotension and bradycardia. CONCLUSION: Anesthesiologists should be aware that epidural analgesia using the LOR to technique injecting air could produce a pneumomediastinum and pneumorrachis, which in turn could produce hemodynamic instability via parasympathetic stimulation.


Subject(s)
Analgesia, Epidural , Arthroplasty, Replacement, Hip , Mediastinal Emphysema , Pneumorrhachis , Humans , Male , Mediastinal Emphysema/etiology , Mediastinal Emphysema/diagnostic imaging , Aged , Analgesia, Epidural/adverse effects , Pneumorrhachis/etiology , Pneumorrhachis/diagnostic imaging , Arthroplasty, Replacement, Hip/adverse effects , Hemodynamics , Tomography, X-Ray Computed , Anesthesia, Spinal/adverse effects
2.
Diseases ; 11(4)2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38131981

ABSTRACT

BACKGROUND: The purpose of this study was to compare the immediate and long-term complications that are associated with the utilized techniques for the insertion of indwelling central venous catheters, that is the open surgical technique, the ultrasound-guided technique, and the transcutaneous technique based on external anatomical landmarks in the right internal jugular vein, to a pediatric population. METHODS: This was a prospective randomized trial based on a pediatric patient population under 16 years of age of a tertiary pediatric-oncological hospital. The procedure was performed by a medical team with varying experience regarding the percutaneous and open insertion methods. We studied the outcome of our procedure, based on the immediate and delayed complication rate, as well as the needed time in order to complete the procedure and mean duration of line use. RESULTS: The patients that were inserted in our protocol were divided into three subgroups based on the selected technique for the insertion of the central venous catheter. A total number of 88 insertions (25.4%) (out of 346) were based on the technique that was using external anatomical landmarks, 121 insertions were based on the ultrasound-guided transcutaneous technique (34.9%), whereas in 137 cases (39.5%) the open surgical technique was preferred. All cases that were related to catheter re-insertion were excluded from our study. We performed a statistical analysis regarding the catheter dwell time between the three subgroups of patients and no significant difference was recorded. Moreover, the development of thrombosis was investigated, and we noted that a higher percentage of this complication was related to the transcutaneous external landmark and open surgical technique. Also, the incidence of infection was taken into consideration, which manifested an increased incidence when the transcutaneous technique based on external landmarks was used. CONCLUSIONS: Ultrasound-guided percutaneous insertion was considered to be a safe and effective technique for the insertion of central venous catheters. Our study also demonstrated a decrease in operating times when performed by operators with increasing expertise, increased preservation of the diameter of the venous lumen, and no increase in complication rates when the ultrasound-guided technique was selected.

SELECTION OF CITATIONS
SEARCH DETAIL