Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Database
Language
Publication year range
1.
Urology ; 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39067637

ABSTRACT

OBJECTIVE: To perform endoscopy in patients with urinary diversions requires specific endoscopic skills, which can currently only be gained in clinical practice. We created a 3D-printed ex vivo ileal conduit model (stoma and conduit with ureters and 2 kidneys) to simulate "conduitoscopy" and evaluated the realism and limitations of the model. METHODS: Accurate anatomical features were represented using an appropriate reusable design, realistic mechanical qualities with several material types, and 3D-printed components. Different models of bowel and ureters were assessed by the subject-matter experts (SME). The final ileal conduit model (Wallace 1 type anastomosis) was evaluated by 18 SMEs. RESULTS: Most experts gave their approval to the view of the stoma, as well as the appearance of the bowel, ureteric, and pelvicalyceal systems. A total of 72.1% of SMEs approved the ureteric endoscopic view compared to about 66% who accepted the endoscopic examination of the bowel. The model's overall appearance was good for 61.1% and excellent for 38.8% of experts. CONCLUSION: Conduitoscopy simulation training can now be facilitated using our novel and unique cutting-edge 3D-printed model. We created a model that is highly anatomically accurate and workable. In our study, anatomical and visual realism was demonstrated. The next step would be increasing the length of the conduit and conduct a validation study.

2.
Urology ; 188: 32-36, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38508533

ABSTRACT

OBJECTIVE: To develop and validate a low-cost, portable, and reusable simulation model for optical internal urethrotomy (OIU) training. METHODS: A 3D-printed low-cost simulation model for OIU was designed locally and the final model was evaluated by trainees and trainers at the urology boot camps (UK, Belgium, Portugal, Poland). Participants were asked to complete a questionnaire, using a 6-item 5-point Likert Scale, to assess the model's anatomic realism. RESULTS: A total of 27 trainees and 9 trainers evaluated the model. The model's anatomy and color were rated as the most realistic features, with 88.9% and 11.1% of respondents rating them as good and excellent, respectively. There were no significant differences between consultants and trainees in their assessment of any of the simulation properties of the OIU model. CONCLUSION: Our study introduces an innovative, lifelike, and cost-effective simulation model for OIU training. Our model provides a realistic simulation of OIU. We feel that our low-cost and reusable model fills the gap in simulation-based training for young trainees in urology.


Subject(s)
Models, Anatomic , Printing, Three-Dimensional , Simulation Training , Urethra , Humans , Simulation Training/economics , Simulation Training/methods , Urethra/surgery , Urethra/anatomy & histology , Urology/education , Male , Urologic Surgical Procedures/education
3.
World J Urol ; 41(9): 2437-2442, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37493708

ABSTRACT

PURPOSE: To present the seven-year experience of a multi-component and interactive module on female, neurological and urodynamic urology (FNUU) training at the UK National Urology Simulation Bootcamp Course (USBC) and demonstrate trainee satisfaction and competency progression. METHODS: During the week-long USBC, a four-hour module on FNUU was designed which consisted of short interactive presentations with an emphasis on practical stations in urodynamics, intravesical botulinum toxin injection, urethral bulking injection, female pelvic examination and, initially, mid-urethral tapes (subsequently replaced with percutaneous sacral nerve evaluation). The trainee's level of knowledge, operative experience and confidence were assessed pre- and post-course. The practical assessment consisted of preparation and intravesical administration of botulinum toxin, female pelvic examination, urodynamic trace interpretation or mid-urethral tape simulation. Trainee feedback was also collected. RESULTS: Two-hundred sixty-one newly appointed urology trainees participated in the USBC during this period. A high level of satisfaction was constantly reported. The highest rated session was urethral bulking with 72% being very satisfied, followed by Botox and urodynamics. The final assessment showed 70% had achieved level 4 competency in cystoscopy and Botox. Qualitative feedback was also obtained. CONCLUSION: To our knowledge, this is the first module of its kind, and it shows that it is feasible to develop, implement and evaluate an introductory curriculum into FNUU that is reproducible over a 7-year period with very positive feedback.


Subject(s)
Botulinum Toxins, Type A , Simulation Training , Urology , Humans , Female , Urology/education , Urodynamics , Clinical Competence , Curriculum
4.
Urologia ; 90(1): 25-29, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35730798

ABSTRACT

BACKGROUND: Stone disease is a common complication of horseshoe kidneys (HSK). There are currently limited studies that examine the relationship between HSK anatomy and stone formation. We aim to determine if there is such an association by measuring the isthmus size and renal angulation in both stone and non-stone forming HSK using computed tomography (CT). METHOD: This is a retrospective study performed at a single tertiary centre. Using the radiological information system, all CT reports between 01 January 2010 and 31 December 2015 were searched for the keyword 'horseshoe' on the radiological information system. This produced a list of 285 reports. Each report and image packet of these 285 studies were reviewed to confirm the presence of an HSK and duplicate patients from multiple examinations were highlighted. One hundred and thirty-eight unique HSK patients were obtained and the studies were assessed for the presence or absence of stones. A total of 112 HSK were found; 88 of which contained no stone and 24 with stone. Angle measurements and isthmus size were measured on these kidneys. As axial images are obtained as standard in all cases, these measurements were all obtained in the axial plane. All parameters were measured and recorded manually by one person so as to reduce inter-observer variability. RESULTS: Isthmus size varied widely, measuring from 2 to 39 mm. Right renal angle ranged from 51 to 158°, left 38 to 152°. CONCLUSION: The isthmus size and renal angle measurements were not found to be significant determinants for stone disease in our patient population.


Subject(s)
Fused Kidney , Urolithiasis , Humans , Fused Kidney/complications , Fused Kidney/diagnostic imaging , Retrospective Studies , Kidney/diagnostic imaging , Tomography, X-Ray Computed
5.
Res Rep Urol ; 12: 111-128, 2020.
Article in English | MEDLINE | ID: mdl-32232016

ABSTRACT

Simulation has emerged as an effective solution to increasing modern constraints in surgical training. It is recognized that a larger proportion of surgical complications occur during the surgeon's initial learning curve. The simulation takes the learning curve out of the operating theatre and facilitates training in a safe and pressure-free environment whilst focusing on patient safety. The cost of simulation is not insignificant and requires commitment in funding, human resources and logistics. It is therefore important for trainers to have evidence when selecting various simulators or devices. Our non-systematic review aims to provide a comprehensive up-to-date picture on urology simulators and the evidence for their validity. It also discusses emerging technologies and future directions. Urologists should embed evidence-based simulation in training programs to shorten learning curves while maintaining patient safety and work should be directed toward a validated and agreed curriculum.

6.
J Surg Case Rep ; 2016(11)2016 Nov 24.
Article in English | MEDLINE | ID: mdl-27887019

ABSTRACT

Penile metastases are rare in colorectal cancer. We report the first case of such a recurrence in a patient who had undergone an extralevator abdominoperineal resection with vertical rectus abdominis myocutaneous flap perineal reconstruction. The patient was treated with curative intent by total penectomy.

7.
Clujul Med ; 86(4): 371-6, 2013.
Article in English | MEDLINE | ID: mdl-26527981

ABSTRACT

AIM: The laparoscopic approach in urological surgery demands a high degree of skill in intracorporeal suturing and knot tying. In an effort to reduce the amount of time required to perform a suture, new materials have been developed that through selfanchorage distribute tension more evenly across the suture and also eliminate the need of knot tying. The goal of this study was to assess the in vivo tissue response to a novel material (V-Loc tm; Covidien) in comparison to established materials (Vicryl, PDS II), in the case of bladder suturing, in a rat model. METHODS: The study included 48 male Wistar rats. All underwent a median abdominal incision, with a 1cm cystotomy, followed by a running suture. The suture material used was either V-Loc absorbable self anchoring thread, Vicryl threaded absorbable suture or monofilament absorbable suture. The abdominal cavity and the bladder suture were macroscopically evaluated at the rats' scheduled death at 3 and 6 weeks. The bladder wall was microscopically assessed by a pathologist, with regard to tissue reaction and suture material degradation. RESULTS: All rats survived the procedure, with the abdominal scar fully healed at week 2. There were no signs of infection or lithiasis during the observation. Macroscopically, at 3 weeks, the suture material was recognizable and visible in all cases, with special mention that the V-Loc thread was considerably more rigid, retaining its shape almost entirely, and provoked more adhesion of the surrounding tissue. At 6 weeks, the suture was indistinguishable in the bladder wall in the case of monofilament absorbable material, barely visible in the case of Vicryl, while the aspect of the V-Loc suture resembled the one at 3 weeks, with the material still clearly visible in the bladder wall, shape almost entirely maintained, and surrounding tissue adherence. Microscopically, at 3 weeks and 6 weeks, all bladder walls examined had regained their structure. At 3 weeks, the monofilament absorbable suture showed intense tissue reaction, with the material already in phagocytosis; at 6 weeks, no clear evidence of leftover material was observed. At 3 weeks, the Vicryl material showed moderate tissue reaction, with phagocytosis initiated between the strands of the material; at 6 weeks, the material was almost entirely absorbed, but with a clear leftover tissue reaction. In the case of the V-Loc suture, due to the hardness of the thread, the material itself could not be cut for analysis with the bladder wall, and the examination could only involve the bladder wall and marks of the thread. Thus, the tissue reaction was minimal, as was the presence of phagocytes at the suture site. The material showed little, if any, signs of absorption after 6 weeks. CONCLUSION: The materials tested all proved equally effective in suturing the bladder wall in a rat model. However, the novel barbed thread proved a consistently low in-vivo absorption rate, while maintaining its rigidity over time. More research is needed to assess the possible clinical implications of these findings.

SELECTION OF CITATIONS
SEARCH DETAIL