Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Front Med (Lausanne) ; 9: 747570, 2022.
Article in English | MEDLINE | ID: mdl-35665323

ABSTRACT

Introduction: Coronavirus disease-2019 (COVID-19) pneumonia has different phenotypes. Selecting the patient individualized and optimal respirator settings for the ventilated patient is a challenging process. Electric impedance tomography (EIT) is a real-time, radiation-free functional imaging technique that can aid clinicians in differentiating the "low" (L-) and "high" (H-) phenotypes of COVID-19 pneumonia described previously. Methods: Two patients ("A" and "B") underwent a stepwise positive end-expiratory pressure (PEEP) recruitment by 3 cmH2O of steps from PEEP 10 to 25 and back to 10 cmH2O during a pressure control ventilation of 15 cmH2O. Recruitment maneuvers were performed under continuous EIT recording on a daily basis until patients required controlled ventilation mode. Results: Patients "A" and "B" had a 7- and 12-day long trial, respectively. At the daily baseline, patient "A" had significantly higher compliance: mean ± SD = 53 ± 7 vs. 38 ± 5 ml/cmH2O (p < 0.001) and a significantly higher physiological dead space according to the Bohr-Enghoff equation than patient "B": mean ± SD = 52 ± 4 vs. 45 ± 6% (p = 0.018). Following recruitment maneuvers, patient "A" had a significantly higher cumulative collapse ratio detected by EIT than patient "B": mean ± SD = 0.40 ± 0.08 vs. 0.29 ± 0.08 (p = 0.007). In patient "A," there was a significant linear regression between the cumulative collapse ratios at the end of the recruitment maneuvers (R 2 = 0.824, p = 0.005) by moving forward in days, while not for patient "B" (R 2 = 0.329, p = 0.5). Conclusion: Patient "B" was recognized as H-phenotype with high elastance, low compliance, higher recruitability, and low ventilation-to-perfusion ratio; meanwhile patient "A" was identified as the L-phenotype with low elastance, high compliance, and lower recruitability. Observation by EIT was not just able to differentiate the two phenotypes, but it also could follow the transition from L- to H-type within patient "A." Clinical Trial Registration: www.ClinicalTrials.gov, identifier: NCT04360837.

2.
Biomed Eng Online ; 19(1): 32, 2020 May 14.
Article in English | MEDLINE | ID: mdl-32410675

ABSTRACT

BACKGROUND AND OBJECTIVE: Lung mechanics measurements provide clinically useful information about disease progression and lung health. Currently, there are no commonly practiced methods to non-invasively measure both resistive and elastic lung mechanics during tidal breathing, preventing the important information provided by lung mechanics from being utilised. This study presents a novel method to easily assess lung mechanics of spontaneously breathing subjects using a dynamic elastance, single-compartment lung model. METHODS: A spirometer with a built-in shutter was used to occlude expiration during tidal breathing, creating exponentially decaying flow when the shutter re-opened. The lung mechanics measured were respiratory system elastance and resistance, separated from the exponentially decaying flow, and interrupter resistance calculated at shutter closure. Progressively increasing resistance was added to the spirometer mouthpiece to simulate upper airway obstruction. The lung mechanics of 17 healthy subjects were successfully measured through spirometry. RESULTS: N = 17 (8 female, 9 male) healthy subjects were recruited. Measured decay rates ranged from 5 to 42/s, subjects with large variation of decay rates showed higher muscular breathing effort. Lung elastance measurements ranged from 3.9 to 21.2 cmH[Formula: see text]O/L, with no clear trend between change in elastance and added resistance. Resistance calculated from decay rate and elastance ranged from 0.15 to 1.95 cmH[Formula: see text]Os/L. These very small resistance values are due to the airflow measured originating from low-resistance areas in the centre of airways. Occlusion resistance measurements were as expected for healthy subjects, and increased as expected as resistance was added. CONCLUSIONS: This test was able to identify reasonable dynamic lung elastance and occlusion resistance values, providing new insight into expiratory breathing effort. Clinically, this lung function test could impact current practice. It does not require high levels of cooperation from the subject, allowing a wider cohort of patients to be assessed more easily. Additionally, this test can be simply implemented in a small standalone device, or with standard lung function testing equipment.


Subject(s)
Exhalation/physiology , Lung/physiology , Respiratory Function Tests/methods , Respiratory Mechanics/physiology , Adult , Female , Humans , Male , Spirometry
SELECTION OF CITATIONS
SEARCH DETAIL
...