Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 76
Filter
1.
Diagnostics (Basel) ; 14(7)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38611632

ABSTRACT

In the early diagnostic workup of acute pancreatitis (AP), the role of contrast-enhanced CT is to establish the diagnosis in uncertain cases, assess severity, and detect potential complications like necrosis, fluid collections, bleeding or portal vein thrombosis. The value of texture analysis/radiomics of medical images has rapidly increased during the past decade, and the main focus has been on oncological imaging and tumor classification. Previous studies assessed the value of radiomics for differentiating between malignancies and inflammatory diseases of the pancreas as well as for prediction of AP severity. The aim of our study was to evaluate an automatic machine learning model for AP detection using radiomics analysis. Patients with abdominal pain and contrast-enhanced CT of the abdomen in an emergency setting were retrospectively included in this single-center study. The pancreas was automatically segmented using TotalSegmentator and radiomics features were extracted using PyRadiomics. We performed unsupervised hierarchical clustering and applied the random-forest based Boruta model to select the most important radiomics features. Important features and lipase levels were included in a logistic regression model with AP as the dependent variable. The model was established in a training cohort using fivefold cross-validation and applied to the test cohort (80/20 split). From a total of 1012 patients, 137 patients with AP and 138 patients without AP were included in the final study cohort. Feature selection confirmed 28 important features (mainly shape and first-order features) for the differentiation between AP and controls. The logistic regression model showed excellent diagnostic accuracy of radiomics features for the detection of AP, with an area under the curve (AUC) of 0.932. Using lipase levels only, an AUC of 0.946 was observed. Using both radiomics features and lipase levels, we showed an excellent AUC of 0.933 for the detection of AP. Automated segmentation of the pancreas and consecutive radiomics analysis almost achieved the high diagnostic accuracy of lipase levels, a well-established predictor of AP, and might be considered an additional diagnostic tool in unclear cases. This study provides scientific evidence that automated image analysis of the pancreas achieves comparable diagnostic accuracy to lipase levels and might therefore be used in the future in the rapidly growing era of AI-based image analysis.

2.
Dtsch Arztebl Int ; 121(9): 284-290, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38530931

ABSTRACT

BACKGROUND: Population-wide research on potential new imaging biomarkers of the kidney depends on accurate automated segmentation of the kidney and its compartments (cortex, medulla, and sinus). METHODS: We developed a robust deep-learning framework for kidney (sub-)segmentation based on a hierarchical, three-dimensional convolutional neural network (CNN) that was optimized for multiscale problems of combined localization and segmentation. We applied the CNN to abdominal magnetic resonance images from the population-based German National Cohort (NAKO) study. RESULTS: There was good to excellent agreement between the model predictions and manual segmentations. The median values for the body-surface normalized total kidney, cortex, medulla, and sinus volumes of 9934 persons were 158, 115, 43, and 24 mL/m2. Distributions of these markers are provided both for the overall study population and for a subgroup of persons without kidney disease or any associated conditions. Multivariable adjusted regression analyses revealed that diabetes, male sex, and a higher estimated glomerular filtration rate (eGFR) are important predictors of higher total and cortical volumes. Each increase of eGFR by one unit (i.e., 1 mL/min per 1.73 m2 body surface area) was associated with a 0.98 mL/m2 increase in total kidney volume, and this association was significant. Volumes were lower in persons with eGFR-defined chronic kidney disease. CONCLUSION: The extraction of image-based biomarkers through CNN-based renal sub-segmentation using data from a population-based study yields reliable results, forming a solid foundation for future investigations.


Subject(s)
Kidney , Magnetic Resonance Imaging , Humans , Male , Female , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/statistics & numerical data , Kidney/diagnostic imaging , Middle Aged , Aged , Adult , Germany , Glomerular Filtration Rate/physiology , Biomarkers/analysis , Neural Networks, Computer , Deep Learning , Cohort Studies
3.
Eur Radiol ; 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38480567

ABSTRACT

OBJECTIVES: Aim of this study was to assess the value of virtual non-contrast (VNC) reconstructions in differentiating between adrenal adenomas and metastases on a photon-counting detector CT (PCD-CT). MATERIAL AND METHODS: Patients with adrenal masses and contrast-enhanced CT scans in portal venous phase were included. Image reconstructions were performed, including conventional VNC (VNCConv) and PureCalcium VNC (VNCPC), as well as virtual monochromatic images (VMI, 40-90 keV) and iodine maps. We analyzed images using semi-automatic segmentation of adrenal lesions and extracted quantitative data. Logistic regression models, non-parametric tests, Bland-Altman plots, and a random forest classifier were used for statistical analyses. RESULTS: The final study cohort consisted of 90 patients (36 female, mean age 67.8 years [range 39-87]) with adrenal lesions (45 adenomas, 45 metastases). Compared to metastases, adrenal adenomas showed significantly lower CT-values in VNCConv and VNCPC (p = 0.007). Mean difference between VNC and true non-contrast (TNC) was 17.67 for VNCConv and 14.85 for VNCPC. Random forest classifier and logistic regression models both identified VNCConv and VNCPC as the best discriminators. When using 26 HU as the threshold in VNCConv reconstructions, adenomas could be discriminated from metastases with a sensitivity of 86.7% and a specificity of 75.6%. CONCLUSION: VNC algorithms overestimate CT values compared to TNC in the assessment of adrenal lesions. However, they allow a reliable discrimination between adrenal adenomas and metastases and could be used in clinical routine in near future with an increased threshold (e.g., 26 HU). Further (multi-center) studies with larger patient cohorts and standardized protocols are required. CLINICAL RELEVANCE STATEMENT: VNC reconstructions overestimate CT values compared to TNC. Using a different threshold (e.g., 26 HU compared to the established 10 HU), VNC has a high diagnostic accuracy for the discrimination between adrenal adenomas and metastases. KEY POINTS: • Virtual non-contrast reconstructions may be promising tools to differentiate adrenal lesions and might save further diagnostic tests. • The conventional and a new calcium-preserving virtual non-contrast algorithm tend to systematically overestimate CT-values compared to true non-contrast images. • Therefore, increasing the established threshold for true non-contrast images (e.g., 10HU) may help to differentiate between adrenal adenomas and metastases on contrast-enhanced CT.

4.
Radiol Med ; 129(3): 401-410, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38319495

ABSTRACT

PURPOSE: To assess the reliability of virtual non-contrast (VNC) derived coronary artery calcium quantities in relation to heart rate and the VNC algorithm used compared to reference true non-contrast (TNC), considering several clinically established acquisition modes. MATERIAL AND METHODS: An ad hoc built coronary phantom containing four calcified lesions and an iodinated lumen was scanned using three cardiac acquisition modes three times within an anthropomorphic cardiac motion phantom simulating different heart rates (0, 60, 80, 100 bpm) and reconstructed with a conventional (VNCconv) and a calcium-sensitive (VNCpc) VNC algorithm. TNC reference was scanned at 0 bpm with non-iodinated lumen. Calcium scores were assessed in terms of number of lesions detected, Agatston and volume scores and global noise was measured. Paired t-test and Wilcoxon test were performed to test measurements for significant difference. RESULTS: For both VNC algorithms used, calcium levels or noise were not significantly affected by heart rate. Measurements on VNCpc reconstructions best reproduced TNC results, but with increased variability (Agatston scores at 0 bpm for TNC, VNCconv, and VNCpc were 47.1 ± 1.1, 6.7 ± 2.8 (p < 0.001), and 45.3 ± 7.6 (p > 0.05), respectively). VNC reconstructions showed lower noise levels compared to TNC, especially for VNCpc (noiseheart on TNC, VNCconv and VNCpc at 0 bpm was 5.0 ± 0.4, 4.5 ± 0.2, 4.2 ± 0.2). CONCLUSION: No significant heart rate dependence of VNC-based calcium scores was observed in an intra-reconstruction comparison. VNCpc reproduces TNC scores better than VNCconv without significant differences and decreased noise, however, with an increasing average deviation with rising heart rates. VNC-based CACS should be used with caution as the measures show higher variability compared to reference TNC and therefore hold the potential of incorrect risk categorization.


Subject(s)
Calcium , Tomography, X-Ray Computed , Humans , Heart Rate , Reproducibility of Results , Tomography, X-Ray Computed/methods , Thorax
5.
Int J Cardiovasc Imaging ; 40(4): 723-732, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38175389

ABSTRACT

The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNCconv) and a calcium-preserving (VNCpc) algorithm. Noise was analyzed by means of the standard deviation of CT-values within the left ventricle. To assess the effectiveness of contrast media removal, heart volumes were segmented and the proportion of their histograms > 130HU was taken. AVC was measured by Agatston and volume score. 41 patients were included. Comparable noise levels to TNC were achieved with all VNC reconstructions. Contrast media was effectively virtually removed (proportions > 130HU from 81% to < 1%). Median calcium scores derived from VNCconv underestimated TNC-based scores (up to 74%). Results with smallest absolute difference to TNC were obtained with VNCpc reconstructions (0.4 mm, Br36, QIR 4), but with persistent significant underestimation (median 29%). Both VNC algorithms showed near-perfect (r²>0.9) correlation with TNC. Thin-slice VNC reconstructions provide equivalent noise levels to standard thick-slice TNC series and effective virtual removal of iodinated contrast. AVC scoring was feasible on both VNC series, showing near-perfect correlation, but with significant underestimation. VNCpc with 0.4 mm slices and Br36 kernel at QIR 4 gave the most comparable results and, with further advances, could be a promising replacement for additional TNC.


Subject(s)
Algorithms , Aortic Valve Stenosis , Aortic Valve , Aortic Valve/pathology , Calcinosis , Computed Tomography Angiography , Multidetector Computed Tomography , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Female , Aged , Male , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Reproducibility of Results , Transcatheter Aortic Valve Replacement/instrumentation , Calcinosis/diagnostic imaging , Contrast Media/administration & dosage
6.
AJNR Am J Neuroradiol ; 45(2): 183-187, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38164551

ABSTRACT

In this anthropomorphic head phantom study, samples containing blood and contrast agent with concentrations ranging from 0 to 6 mg iodine per milliliter and another set of samples without blood for reference were scanned with a photon-counting detector CT using a standard cranial protocol. It was demonstrated that photon-counting detector CT can reliably distinguish hemorrhage and contrast media, including density determination of the latter. The technology promises to add value in several neuroimaging applications.


Subject(s)
Contrast Media , Iodine , Humans , Photons , Tomography, X-Ray Computed/methods , Hemorrhage , Phantoms, Imaging
7.
Abdom Radiol (NY) ; 49(1): 103-116, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37796327

ABSTRACT

PURPOSE: To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT). METHODS: Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40-190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV). RESULTS: Thirty-eight patients (mean age 70.4 years ± 10.3 [range 45-91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (≤ 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (≤ 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT. CONCLUSION: PCD-CT VMI reconstructions (≤ 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Radiography, Dual-Energy Scanned Projection , Male , Humans , Aged , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods , Pancreatic Neoplasms/diagnostic imaging , Carcinoma, Pancreatic Ductal/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods
8.
Colorectal Dis ; 26(2): 335-347, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38115093

ABSTRACT

AIM: The aims of this study were to analyse all hospitalizations for acute diverticulitis in Germany from 2010 to 2021 and to assess the effects of the first 2 years of the SARS-CoV-2 pandemic on hospitalizations for acute diverticulitis. METHOD: Using data from the German Federal Statistical Office, we analysed fully anonymized healthcare data of hospitalizations and treatment regimens with acute diverticulitis as the main diagnosis between 2010 and 2021. Logistic regression analyses for in-hospital mortality were performed. RESULTS: A total of 608,162 hospitalizations were included. While the number of hospitalizations constantly increased until 2019 (+52.4%), a relative decrease of 10.1% was observed between 2019 and 2020, followed by stable numbers of hospitalizations in 2021 (+1.1% compared with 2020). In-hospital mortality showed a relative decrease of 33.2% until 2019 and thereafter a relative increase of 26.9% in 2020 and of 7.5% in 2021. A 21.6% and a 19.3% drop in hospitalizations was observed during the first and second waves of the SARS-CoV-2 pandemic, mostly affecting hospitalizations for uncomplicated diverticulitis, with a corresponding 11.6% and 16.8% increase in admissions for complicated diverticulitis. Multivariable logistic regression analyses showed significantly higher in-hospital mortality for hospitalizations in which surgery (OR = 2.76) and CT (OR = 1.32) were given, as well as lower mortality for women (OR = 0.88), whereas percutaneous drainage was not associated with higher in-hospital mortality compared with conservative treatment (OR = 0.71). CONCLUSION: This study points out the long-term trends in inpatient treatment for acute diverticulitis and the in-hospital mortality risk factors of patients hospitalized for acute diverticulitis in a large nationwide cohort, as well as changes in these trends and factors resulting from the SARS-CoV-2 pandemic. These changes might be attributable to delayed diagnosis and thus more severe stages of disease as a result of containment measures.


Subject(s)
COVID-19 , Diverticulitis , Humans , Female , SARS-CoV-2 , Pandemics , Inpatients , COVID-19/epidemiology , Diverticulitis/therapy , Hospitalization , Retrospective Studies
9.
Contemp Clin Trials ; 135: 107384, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37949165

ABSTRACT

OBJECTIVES: Medical imaging plays an essential role in healthcare. As a diagnostic test, imaging is prone to substantial overuse and potential overdiagnosis, with dire consequences to patient outcomes and health care costs. Clinical decision support systems (CDSSs) were developed to guide referring physicians in making appropriate imaging decisions. This study will evaluate the effect of implementing a CDSS (ESR iGuide) with versus without active decision support in a physician order entry on the appropriate use of imaging tests and ordering behaviour. METHODS: A protocol for a multi-center cluster-randomized trial with departments acting as clusters, combined with a before-after-revert design. Four university hospitals with eight participating departments each for a total of thirty-two clusters will be included in the study. All departments start in control condition with structured data entry of the clinical indication and tracking of the imaging exams requested. Initially, the CDSS is implemented and all physicians remain blinded to appropriateness scores based on the ESR imaging referral guidelines. After randomization, half of the clusters switch to the active intervention of decision support. Physicians in the active condition are made aware of the categorization of their requests as appropriate, under certain conditions appropriate, or inappropriate, and appropriate exams are suggested. Physicians may change their requests in response to feedback. In the revert condition, active decision support is removed to study the educational effect. RESULTS/CONCLUSIONS: The main outcome is the proportion of inappropriate diagnostic imaging exams requested per cluster. Secondary outcomes are the absolute number of imaging exams, radiation from diagnostic imaging, and medical costs. TRIAL REGISTRATION NUMBER: Approval from the Medical Ethics Review Committee was obtained under protocol numbers 20-069 (Augsburg), B 238/21 (Kiel), 20-318 (Lübeck) and 2020-15,125 (Mainz). The trial is registered in the ClinicalTrials.gov register under registration number NCT05490290.


Subject(s)
Decision Support Systems, Clinical , Humans , Diagnostic Imaging , Randomized Controlled Trials as Topic , Multicenter Studies as Topic
10.
Eur J Radiol ; 168: 111125, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37804649

ABSTRACT

PURPOSE: Aim of this study was to determine which virtual non-contrast (VNC) reconstruction algorithm, applied to which contrast phase of computed tomography angiography, best matches true non-contrast (TNC) images in the assessment of active bleeding. METHOD: Patients who underwent a triphasic scan (pre-contrast, arterial, portal venous contrast) on a photon-counting detector CT (PCD-CT) (120 kV, image quality level 68) with suspected active (tumor, postoperative, spontaneous or other) bleeding were retrospectively included in this study. Conventional (VNCConv) and a calcium-preserving VNC algorithm (VNCPC) were derived from both arterial (art) and portal venous (pv) contrast scans, and analyzed quantitatively and qualitatively by two independent and blinded raters. RESULTS: 40 patients (22 female, mean age 76 years) were included. Measurements of CT values showed significant albeit small differences between TNC and VNC for most analyzed tissue regions without clear superiority of a VNC algorithm or contrast phase (e.g. ΔHU fat TNC to VNCPCpv 3.1 HU). However, qualitative analysis showed a preference to VNCPCpv in terms of image quality (on a 5-point Likert scale VNCConvart = 3.5 ± 0.8, VNCPCart = 3.7 ± 0.7, VNCConvpv = 3.7 ± 0.7, VNCPCpv = 3.8 ± 0.7) and residual calcium contrast (VNCConvart = 3.0 ± 0.8, VNCPCart = 3.5 ± 0.7, VNCConvpv = 3.6 ± 0.7, VNCPCpv = 3.9 ± 0.6). CONCLUSIONS: When multiple post-contrast phases are available, VNCPC series based on portal venous phase are the most suitable replacement for an additional pre-contrast scan, with the prospect of a significant reduction in patient radiation dose.


Subject(s)
Calcium , Tomography, X-Ray Computed , Humans , Female , Aged , Retrospective Studies , Tomography, X-Ray Computed/methods , Computed Tomography Angiography/methods , Hemorrhage , Algorithms
11.
Cardiovasc Intervent Radiol ; 46(10): 1385-1393, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37700006

ABSTRACT

PURPOSE: To investigate differences in thermal sensitivity of virtual monoenergetic imaging (VMI) series generated from photon-counting detector (PCD) CT data sets, regarding their use to improve discrimination of the ablation zone during percutaneous cryoablation. MATERIALS AND METHODS: CT-guided cryoablation was performed using an ex vivo model of porcine liver on a PCD-CT system. The ablation zone was imaged continuously for 8 min by acquiring a CT scan every 5 s. Tissue temperature was measured using fiberoptic temperature probes placed parallel to the cryoprobe. CT-values and noise were measured at the tip of the temperature probes on each scan and on VMI series from 40 to 130 keV. Correlation of CT-values and temperature was assessed using linear regression analyses. RESULTS: For the whole temperature range of [- 40, + 20] °C, we observed a linear correlation between CT-values and temperature in reference 70 keV images (R2 = 0.60, p < 0.001) with a thermal sensitivity of 1.4HU/°C. For the most dynamic range of [- 15, + 20] °C, the sensitivity increased to 2.4HU/°C (R2 = 0.50, p < 0.001). Using VMI reconstructions, the thermal sensitivity increased from 1.4 HU/°C at 70 keV to 1.5, 1.7 and 2.0HU/°C at 60, 50 and 40 keV, respectively (range [- 40, + 20] °C). For [- 15, + 20]°C, the thermal sensitivity increased from 2.4HU/°C at 70 keV to 2.5, 2.6 and 2.7HU/°C at 60, 50 and 40 keV, respectively. Both CT-values and noise also increased with decreasing VMI keV-levels. CONCLUSION: During CT-guided cryoablation of porcine liver, low-keV VMI reconstructions derived from PCD-CT data sets exhibit improved thermal sensitivity being highest between + 20 and - 15 °C.


Subject(s)
Cryosurgery , Swine , Animals , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods , Liver/diagnostic imaging , Liver/surgery , Abdomen , Retrospective Studies , Radiographic Image Interpretation, Computer-Assisted/methods
12.
BMC Gastroenterol ; 23(1): 300, 2023 Sep 06.
Article in English | MEDLINE | ID: mdl-37674195

ABSTRACT

BACKGROUND: Aim of this study was to analyze long-term trends of hospitalizations, treatment regimen and in-hospital mortality of in-patients with acute mesenteric ischemia (AMI) over the past decade and effects of the SARS-CoV2-pandemic. METHODS: We analyzed fully anonymized data from the German Federal Statistical Office of patients with AMI between 2010 and 2020. Besides descriptive analyses of age, gender, in-hospital mortality, comorbidity burden and treatment regimen, multivariable logistic regression analyses were performed to identify independent variables associated with in-hospital mortality and different treatment. RESULTS: A total of 278,121 hospitalizations (120,667 male [43.4%], mean age 72.1 years) with AMI were included in this study. The total number of hospitalizations increased from 2010 (n = 24,172) to 2019 (n = 26,684) (relative increase 10.4%). In-hospital mortality decreased over the past decade from 36.6% to 2010 to 31.1% in 2019 (rel. decrease 15.2%). Independent risk factors for in-hospital mortality were older age (OR = 1.03 per year), higher comorbidity burden (OR = 1.06 per point in van Walraven score [vWs]), male gender (OR = 1.07), AMI as a secondary diagnosis (OR = 1.44), and the need for surgical (visceral surgery: OR = 1.38, vascular surgery: OR = 3.33) and endovascular treatment (OR = 1.21). We report a decline in hospitalizations during the first wave of infection in spring 2020 (rel. decrease 9.7%). CONCLUSION: In-hospital mortality rate has declined over the past decade, but remains high at above 30%. Older age, increased comorbidity and male gender are independent factors for in-hospital mortality. Hospitalizations requiring vascular surgery are associated with high in-hospital mortality, followed by visceral surgery and endovascular approaches. The first wave of the SARS-CoV2-pandemic in spring 2020 implied a decrease in hospital admissions.


Subject(s)
COVID-19 , Mesenteric Ischemia , Humans , Male , Aged , Mesenteric Ischemia/epidemiology , Mesenteric Ischemia/surgery , RNA, Viral , COVID-19/epidemiology , SARS-CoV-2 , Hospital Mortality
13.
CVIR Endovasc ; 6(1): 44, 2023 Aug 29.
Article in English | MEDLINE | ID: mdl-37642825

ABSTRACT

PURPOSE: Aim of this study was to analyze hospitalizations due to ruptured and non-ruptured abdominal aortic aneurysms (rAAA, nrAAA) in Germany between 2005 and 2021 to determine long-term trends in treatment and the impact of the SARS-CoV-2 pandemic. MATERIALS AND METHODS: Fully anonymized data were available from the research data center (RDC) of the German Federal Statistical Office (Destatis). All German hospitalizations with the ICD-10 code "I71.3, rAAA" and "I71.4, nrAAA" in 2005 and 2010-2021 were analyzed. RESULTS: We report data of a total of 202,951 hospitalizations. The number of hospitalizations increased from 2005 to 2019 (14,075 to 16,051, + 14.0%). The rate of open repair (OR) constantly decreased, whereas the rate of endovascular aortic repair (EVAR) increased until 2019. During the pandemic, the number of hospitalizations due to nrAAA dropped from 13,887 (86.5%) in 2019 to 11,278 (85.0%) in 2021. The strongest decrease of hospitalizations for AAA was observed during the first wave of the SARS-CoV-2-pandemic in spring 2020 (-25.5%). CONCLUSION: Over the past decades, we observed an increasing number of hospitalizations due to AAA accompanied by a shift from OR to EVAR especially for nrAAA. During the lockdown measures due to the SARS-CoV-2-pandemic, a decrease in hospitalizations for nrAAA (but not for rAAA) was shown in 2020 and furthermore in 2021 with no rebound of treatment of nrAAA suggesting an accumulation of untreated AAA with a potentially increased risk of rupture.

14.
Eur J Radiol ; 166: 110967, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37487433

ABSTRACT

PURPOSE: To correlate CT values of the blood pool on VNC series with serum hemoglobin values for the detection of anemia in oncologic patients undergoing contrast-enhanced PCD-CT scans. METHODS: This prospective study (NCT04989192) included consecutive oncologic patients undergoing contrast-enhanced CT on a novel PCD-CT system between 08/2021 and 01/2022. The interval between complete blood count (CBC) and CT scan acquisition had to be no more than seven days. CT-values of the blood pool were measured on 70 keV VMI series (CT-values(BP)70keV) and on VNC series (CT-values(BP)VNC) at five anatomic positions (left atrium, left ventricle, main pulmonary artery, ascending and descending aorta) and averaged per patient. Pearson correlation analyses and ROC analyses were performed to identify relations between CT-values(BP)VNC, CBC parameters, and degrees of anemia as defined by the WHO (no anemia, mild, moderate, severe anemia). RESULTS: A total of 329 patients (age 68 ± 12 years; 200 men) were included. CT-values(BP)VNC showed a strong linear correlation to serum hemoglobin (r2 = 0.80, p <.001) and hematocrit (r2 = 0.76, p <.001) and were significantly different between anemia subgroups in both women and men (ΔHU: 3.5-11.4; all p <.01). ROC analyses yielded high diagnostic performance for the identification of patients without anemia, patients without and with mild anemia, and patients with severe anemia using gender-specific cutoffs for CT-value(BP)VNC (all AUC's > 0.90). CONCLUSIONS: The spectral information inherent in PCD-CT acquisitions allows the detection and quantification of anemia in contrast-enhanced CT acquisitions of oncologic patients with high diagnostic accuracy.


Subject(s)
Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Hemoglobins , Prospective Studies , ROC Curve , Proof of Concept Study
15.
Eur J Radiol ; 165: 110946, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37399668

ABSTRACT

PURPOSE: To investigate the usefulness of virtual monoenergetic image (VMI) reconstructions derived from scans on a novel photon-counting detector CT (PCD-CT) for artifact reduction in patients after posterior spinal fixation. METHODS: This retrospective cohort study included 23 patients status post posterior spinal fixation. Subjects were scanned on a novel PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) as part of routine clinical care. 14 sets of VMI reconstructions were derived in 10 keV increments for the interval 60-190 keV. The mean and the standard deviation (SD) of CT-values in 12 defined locations around a pair of pedicle screws on one vertebral level and the SD of homogenous fat were measured and used to calculate an artifact index (AIx). RESULTS: Averaged over all regions, the lowest AIx was observed at VMI levels of 110 keV (32.5 (27.8-37.9)) which was significantly different from those of VMIs ≤ 90 keV (p < 0.001) or ≥160 keV (p < 0.015), respectively. Overall AIx values increased in both lower- and higher-keV levels. Regarding individual locations, either a monotonous AIx-decrease for increasing keV values or an AIx-minimum in intermediate-keV levels (100-140 keV) was found. In locations adjacent to larger metal parts, the increase of AIx values at the high-end of the keV spectrum was mainly explained by a reappearance of streak artifacts. CONCLUSION: Our findings suggest that 110 keV is the optimal VMI setting for overall artifact suppression. In specific anatomical regions, however, slight adjustments towards higher-keV levels may provide better results.


Subject(s)
Artifacts , Tomography, X-Ray Computed , Humans , Retrospective Studies , Tomography, X-Ray Computed/methods , Spine/diagnostic imaging , Spine/surgery , Metals , Radiographic Image Interpretation, Computer-Assisted/methods , Signal-To-Noise Ratio
16.
Cancers (Basel) ; 15(10)2023 May 17.
Article in English | MEDLINE | ID: mdl-37345128

ABSTRACT

This study analyzes nationwide trends in HCC hospitalizations focusing on interventional liver-directed treatments and the influence of age and gender. Using data from the German Federal Statistical Office all hospitalizations for HCC between 2010 and 2020 were included. Uni- and multivariable logistic regression analyses were performed to identify variables independently associated with the use of liver-directed therapies. Due to the COVID-19 pandemic, data from 2020 were analyzed separately. A total of 134,713 hospitalizations (2010-2019) were included, increasing by 3.4% annually (12,707 to 13,143). The mean in-hospital stay (-15.0% [7.2 to 6.1 days]) and mortality (-23.2% [6.8 to 5.2%]) decreased while transarterial, surgical, and percutaneous ablative interventions increased by 38.6, 31.5, and 19.3%, respectively. In-hospital mortality was 7.7% in admissions with surgical treatment, while it was 0.6 and 0.5% for transarterial and percutaneous interventions. Mortality was higher in females (6.2 vs. 5.7%). Females (OR 0.89 [0.86,0.91], p < 0.001) and patients ≥80 years (OR 0.81 [0.79,0.84], p < 0.001) were less likely to receive liver-directed treatments. Liver-directed therapies were increasingly performed while in-hospital mortality and in-hospital stay decreased. Minimally invasive approaches showed lower mortality, shorter in-hospital stay, and lower costs compared to surgery. Proportionately, more women and older patients were hospitalized, receiving fewer liver-directed treatments while their mortality was higher.

17.
Diagn Interv Radiol ; 29(3): 492-499, 2023 05 31.
Article in English | MEDLINE | ID: mdl-36993776

ABSTRACT

PURPOSE: Re-entry devices contribute to the high success rate of subintimal recanalization of chronic total occlusions (CTO). However, to date, there are no studies comparing the available conventional re-entry devices concerning the impact of their technical success on economic aspects, as these devices differ greatly in their acquisition costs. This prospective observational study intends to contribute to this question. METHODS: Prior to the start of the prospective study, all previous applications of the Outback® in femoro-popliteal CTO since its introduction to our hospital were analyzed retrospectively (n = 31). From June 2018 until January 2020, all patients with femoro-popliteal CTO treated with clear subintimal recanalization were included (n = 109). In the case of failed spontaneous re-entry, either the OffRoad® (study arm I, n = 20) or the Enteer® catheter (study arm II, n = 20) was used. If assisted re-entry failed, the Outback® device was used as a bailout. Baseline demographic and clinical data, morphologic characteristics, and technical success were documented. Additional per-patient costs due to the use of re-entry devices were analyzed. RESULTS: A retrospective evaluation of all Outback® applications revealed a technical success rate of 97% (30/31). In the prospective study, 63% (68/109) were successfully treated without using re-entry devices. The overall procedural success was 95% (103/109). In study arm I, the OffRoad® achieved a success rate of 45% (9/20), with a subsequent successful application of the Outback® in 80% (8/10) of the failed cases. In study arm II, the Enteer® was successfully employed in 60% (12/20) of cases, and the Outback® was then used successfully in a further 62% (5/8) of cases. Too large a distance between the device and the target lumen was a knockout criterion for all tested devices, leading to a subgroup analysis with the exclusion of three cases, resulting in a success rate of 47% for the OffRoad® and 67% for the Enteer® device. Furthermore, in severe calcification, only the Outback® reliably enabled revascularization. Significant savings of almost €600 were only achieved in study arm II according to German prices. CONCLUSION: With proper patient selection, a gradual approach with the Enteer® as the primarily used device, with the Outback® used additionally in case of failure, leads to significant savings and can be recommended. In severe calcification, the Outback® should be used as the primary device.


Subject(s)
Arterial Occlusive Diseases , Peripheral Arterial Disease , Humans , Retrospective Studies , Prospective Studies , Treatment Outcome , Femoral Artery/surgery , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/surgery , Arterial Occlusive Diseases/therapy , Chronic Disease
18.
Diagnostics (Basel) ; 13(6)2023 Mar 18.
Article in English | MEDLINE | ID: mdl-36980471

ABSTRACT

PURPOSE: Coronary artery disease (CAD) and peripheral artery disease (PAD) are highly prevalent in society. This nationwide analysis aimed to evaluate the trends of in-hospital treatment of patients admitted due to PAD with and without concomitant CAD, to determine the prevalence and risk factors of concomitant CAD in patients with PAD. METHODS: Using data from the German Federal Statistical Office, we included all admissions for PAD (with and without concomitant CAD) in Germany between 2009 and 2018. Baseline patient characteristics, outcomes and comorbidities were analyzed. Elixhauser comorbidity groups and the linear van Walraven comorbidity score (vWs) were calculated to assess the comorbidity burden. RESULTS: Of all 1,793,517 patients hospitalized for PAD, a total of 21.8% (390,259) had concomitant CAD, increasing from 18.6% in 2009 to 24.4% in 2018. Patients with accompanying CAD showed higher in-hospital mortality (3.7 vs. 2.6%), more major amputations (9.0 vs. 7.7%) and more comorbidities (Elixhauser score: 4.2 vs. 3.2 and vWs: 9.1 vs. 6.1), resulting in higher costs (median: EUR 4541 vs. EUR 4268 per case). More advanced stages of PAD were associated with multi-vessel CAD (10% of all patients with PAD Fontaine IV showed 3-vessel CAD) and the prevalence of multi-vessel CAD increased predominantly in patients with advanced PAD. CONCLUSION: One in four patients hospitalized for PAD had concomitant CAD, showing an increase over time with an additional medical and economic burden for hospitals compared with patients without CAD.

19.
Invest Radiol ; 58(9): 691-696, 2023 09 01.
Article in English | MEDLINE | ID: mdl-36897803

ABSTRACT

OBJECTIVE: The aim of this study was to compare the effectiveness of common strategies for artifact reduction of dental material in photon-counting detector computed tomography data sets. MATERIALS AND METHODS: Patients with dental material who underwent clinically indicated CT of the neck were enrolled. Image series were reconstructed using a standard and sharp kernel, with and without iterative metal artifact reduction (IMAR) (Qr40, Qr40 IMAR , Qr60, Qr60 IMAR ) at different virtual monoenergetic imaging (VMI) levels (40-190 keV). On representative slice positions with and without dental artifacts, mean and standard deviation of CT values were measured in all series at identical locations. The mean absolute error of CT values ( ) and the artifact index (AIX) were calculated and analyzed focusing on 3 main comparisons: ( a ) different VMI levels versus 70 keV, ( b ) standard versus sharp kernel, and ( c ) nonuse or use of IMAR reconstruction. The Wilcoxon test was used to assess differences for nonparametric data. RESULTS: The final cohort comprised 50 patients. Artifact measures decreased for VMI levels >70 keV, yet only significantly so for reconstructions using IMAR (maximum reduction, 25%). The higher image noise of the sharp versus standard kernel is reflected in higher AIX values and is more pronounced in IMAR series (maximum increase, 38%). The most profound artifact reduction was observed for IMAR reconstructions (maximum reduction : 84%; AIX: 90%). CONCLUSIONS: Metal artifacts caused by large amounts of dental material can be substantially reduced by IMAR, regardless of kernel choice or VMI settings. Increasing the keV level of VMI series, on the other hand, only slightly reduces dental artifacts; this effect, however, is additive to the benefit conferred by IMAR reconstructions.


Subject(s)
Artifacts , Metals , Humans , Tomography, X-Ray Computed/methods , Neck , Dental Materials , Algorithms
20.
Eur Radiol ; 33(4): 2450-2460, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36462042

ABSTRACT

OBJECTIVES: To assess epicardial adipose tissue (EAT) volume and attenuation of different virtual non-contrast (VNC) reconstructions derived from coronary CTA (CCTA) datasets of a photon-counting detector (PCD) CT-system to replace true non-contrast (TNC) series. METHODS: Consecutive patients (n = 42) with clinically indicated CCTA and coronary TNC were included. Two VNC series were reconstructed, using a conventional (VNCConv) and a novel calcium-preserving (VNCPC) algorithm. EAT was segmented on TNC, VNCConv, VNCPC, and CCTA (CTA-30) series using thresholds of -190 to -30 HU and an additional segmentation on the CCTA series with an upper threshold of 0 HU (CTA0). EAT volumes and their histograms were assessed for each series. Linear regression was used to correlate EAT volumes and the Euclidian distance for histograms. The paired t-test and the Wilcoxon signed-rank test were used to assess differences for parametric and non-parametric data. RESULTS: EAT volumes from VNC and CCTA series showed significant differences compared to TNC (all p < .05), but excellent correlation (all R2 > 0.9). Measurements on the novel VNCPC series showed the best correlation (R2 = 0.99) and only minor absolute differences compared to TNC values. Mean volume differences were -12%, -3%, -13%, and +10% for VNCConv, VNCPC, CTA-30, and CTA0 compared to TNC. Distribution of CT values on VNCPC showed less difference to TNC than on VNCConv (mean attenuation difference +7% vs. +2%; Euclidean distance of histograms 0.029 vs. 0.016). CONCLUSIONS: VNCPC-reconstructions of PCD-CCTA datasets can be used to reliably assess EAT volume with a high accuracy and only minor differences in CT values compared to TNC. Substitution of TNC would significantly decrease patient's radiation dose. KEY POINTS: • Measurement of epicardial adipose tissue (EAT) volume and attenuation are feasible on virtual non-contrast (VNC) series with excellent correlation to true non-contrast series (all R2>0.9). • Differences in VNC algorithms have a significant impact on EAT volume and CT attenuation values. • A novel VNC algorithm (VNCPC) enables reliable assessment of EAT volume and attenuation with superior accuracy compared to measurements on conventional VNC- and CCTA-series.


Subject(s)
Angiography , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Reproducibility of Results , Photons , Adipose Tissue/diagnostic imaging , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...