1.
PLoS One ; 16(1): e0244877, 2021.
Article in English | MEDLINE | ID: mdl-33411722

ABSTRACT

BACKGROUND: Digital devices and wearables allow for the measurement of a wide range of health-related parameters in a non-invasive manner, which may be particularly valuable in pediatrics. Incorporation of such parameters in clinical trials or care as digital endpoint could reduce the burden for children and their parents but requires clinical validation in the target population. This study aims to determine the tolerability, repeatability, and reference values of novel digital endpoints in healthy children. METHODS: Apparently healthy children (n = 175, 46% male) aged 2-16 were included. Subjects were monitored for 21 days using a home-monitoring platform with several devices (smartwatch, spirometer, thermometer, blood pressure monitor, scales). Endpoints were analyzed with a mixed effects model, assessing variables that explained within- and between-subject variability. Endpoints based on physical activity, heart rate, and sleep-related parameters were included in the analysis. For physical-activity-related endpoints, a sample size needed to detect a 15% increase was calculated. FINDINGS: Median compliance was 94%. Variability in each physical activity-related candidate endpoint was explained by age, sex, watch wear time, rain duration per day, average ambient temperature, and population density of the city of residence. Estimated sample sizes for candidate endpoints ranged from 33-110 per group. Daytime heart rate, nocturnal heart rate and sleep duration decreased as a function of age and were comparable to reference values published in the literature. CONCLUSIONS: Wearable- and portable devices are tolerable for pediatric subjects. The raw data, models and reference values presented here can be used to guide further validation and, in the future, clinical trial designs involving the included measures.


Subject(s)
Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Adolescent , Child , Child, Preschool , Exercise/physiology , Female , Heart Rate/physiology , Humans , Male , Patient Compliance , Reference Values , Reproducibility of Results , Sleep/physiology , Wearable Electronic Devices/trends
2.
Pharmacol Rev ; 72(4): 899-909, 2020 10.
Article in English | MEDLINE | ID: mdl-32958524

ABSTRACT

Novel digital endpoints gathered via wearables, small devices, or algorithms hold great promise for clinical trials. However, implementation has been slow because of a lack of guidelines regarding the validation process of these new measurements. In this paper, we propose a pragmatic approach toward selection and fit-for-purpose validation of digital endpoints. Measurements should be value-based, meaning the measurements should directly measure or be associated with meaningful outcomes for patients. Devices should be assessed regarding technological validity. Most importantly, a rigorous clinical validation process should appraise the tolerability, difference between patients and controls, repeatability, detection of clinical events, and correlation with traditional endpoints. When technically and clinically fit-for-purpose, case building in interventional clinical trials starts to generate evidence regarding the response to new or existing health-care interventions. This process may lead to the digital endpoint replacing traditional endpoints, such as clinical rating scales or questionnaires in clinical trials. We recommend initiating more data-sharing collaborations to prevent unnecessary duplication of research and integration of value-based measurements in clinical care to enhance acceptance by health-care professionals. Finally, we invite researchers and regulators to adopt this approach to ensure a timely implementation of digital measurements and value-based thinking in clinical trial design and health care. SIGNIFICANCE STATEMENT: Novel digital endpoints are often cited as promising for the clinical trial of the future. However, clear validation guidelines are lacking in the literature. This paper contains pragmatic criteria for the selection, technical validation, and clinical validation of novel digital endpoints and provides recommendations for future work and collaboration.


Subject(s)
Clinical Trials as Topic/methods , Biomarkers/analysis , Biomarkers/metabolism , Endpoint Determination/methods , Humans , Reproducibility of Results