Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Pers Med ; 13(9)2023 Sep 19.
Article in English | MEDLINE | ID: mdl-37763164

ABSTRACT

In order to successfully implement individualized patient rehabilitation and home-based rehabilitation programs, the rehabilitation process should be objectifiable, monitorable and comprehensible. For this purpose, objective measurements are required in addition to subjective measurement tools. Thus, the aim of this prospective, single-center clinical trial is the clinical validation of an objective, digital medical device (DMD) during the rehabilitation after anterior cruciate ligament reconstruction (ACLR) with regards to an internationally accepted measurement tool. Sixty-seven patients planned for primary ACLR (70:30% male-female, aged 25 years [21-32], IKDC-SKF 47 [31-60], Tegner Activity Scale 6 [4-7], Lysholm Score 57 [42-72]) were included and received physical therapy and the DMD after surgery. For clinical validation, combined measures of range of motion (ROM), coordination, strength and agility were assessed using the DMD in addition to patient-reported outcome measures (PROMs) at three and six months after ACLR. Significant correlations were detected for ROM (rs = 0.36-0.46, p < 0.025) and strength/agility via the single-leg vertical jump (rs = 0.43, p = 0.011) and side hop test (rs = 0.37, p = 0.042), as well as for coordination via the Y-Balance test (rs = 0.58, p ≤ 0.0001) regarding the IKDC-SKF at three months. Additionally, DMD test results for coordination, strength and agility (Y-Balance test (rs = 0.50, p = 0.008), side hop test (rs = 0.54, p = 0.004) and single-leg vertical jump (rs = 0.44, p = 0.018)) correlate significantly with the IKDC-SKF at six months. No adverse events related to the use of the sensor-based application were reported. These findings confirm the clinical validity of a DMD to objectively quantify knee joint function for the first time. This will have further implications for clinical and therapeutic decision making, quality control and monitoring of rehabilitation measures as well as scientific research.

2.
Metabolites ; 11(11)2021 Nov 18.
Article in English | MEDLINE | ID: mdl-34822448

ABSTRACT

In high-intensity interval training the interval duration can be adjusted to optimize training results in oxygen uptake, cardiac output, and local oxygen supply. This study aimed to compare these variables in two interval trainings (long intervals HIIT3m: 3 min work, 3 min active rest vs. short intervals HIIT30s: 30 s work, 30 s active rest) at the same overall work rate and training duration. 24 participants accomplished both protocols, (work: 80% power output at VO2peak, relief: 85% power output at gas exchange threshold) in randomized order. Spirometry, impedance cardiography, and near-infrared spectroscopy were used to analyze the physiological stress of the cardiopulmonary system and muscle tissue. Although times above gas exchange threshold were shorter in HIIT3m (HIIT3m 1669.9 ± 310.9 s vs. HIIT30s 1769.5 ± 189.0 s, p = 0.034), both protocols evoked similar average fractional utilization of VO2peak (HIIT3m 65.23 ± 4.68% VO2peak vs. HIIT30s 64.39 ± 6.78% VO2peak, p = 0.261). However, HIIT3m resulted in higher cardiovascular responses during the loaded phases (VO2p < 0.001, cardiac output p < 0.001). Local hemodynamics were not different between both protocols. Average physiological responses were not different in both protocols owning to incomplete rests in HIIT30s and large response amplitudes in HIIT3m. Despite lower acute cardiovascular stress in HIIT30s, short submaximal intervals may also trigger microvascular and metabolic adaptions similar to HIIT3m. Therefore, the adaption of interval duration is an important tool to adjust the goals of interval training to the needs of the athlete or patient.

SELECTION OF CITATIONS
SEARCH DETAIL
...