Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Anal Chem ; 95(37): 13932-13940, 2023 09 19.
Article in English | MEDLINE | ID: mdl-37676066

ABSTRACT

In environmental research, it is critical to understand how toxins impact invertebrate eggs and egg banks, which, due to their tiny size, are very challenging to study by conventional nuclear magnetic resonance (NMR) spectroscopy. Microcoil technology has been extensively utilized to enhance the mass-sensitivity of NMR. In a previous study, 5-axis computer numerical control (CNC) micromilling (shown to be a viable alternative to traditional microcoil production methods) was used to create a prototype copper slotted-tube resonator (STR). Despite the excellent limit of detection (LOD) of the resonator, the quality of the line shape was very poor due to the magnetic susceptibility of the copper resonator itself. This is best solved using magnetic susceptibility-matched materials. In this study, approaches are investigated that improve the susceptibility while retaining the versatility of coil milling. One method involves machining STRs from various copper/aluminum alloys, while the other involves machining ones from an aluminum 2011 alloy and electroplating them with copper. In all cases, combining copper and aluminum to produce resonators resulted in improved line shape and SNR compared to pure copper resonators due to their reduced magnetic susceptibility. However, the copper-plated aluminum resonators showed optimal performance from the devices tested. The enhanced LOD of these STRs allowed for the first 1H-13C heteronuclear multiple quantum coherence (HMQC) of a single intact 13C-labeled Daphnia magna egg (∼4 µg total biomass). This is a key step toward future screening programs that aim to elucidate the toxic processes in aquatic eggs.


Subject(s)
Aluminum , Copper , Animals , Alloys , Biomass , Daphnia
2.
Anal Chem ; 95(14): 5858-5866, 2023 04 11.
Article in English | MEDLINE | ID: mdl-36996326

ABSTRACT

Toxicity testing is currently undergoing a paradigm shift from examining apical end points such as death, to monitoring sub-lethal toxicity in vivo. In vivo nuclear magnetic resonance (NMR) spectroscopy is a key platform in this endeavor. A proof-of-principle study is presented which directly interfaces NMR with digital microfluidics (DMF). DMF is a "lab on a chip" method allowing for the movement, mixing, splitting, and dispensing of µL-sized droplets. The goal is for DMF to supply oxygenated water to keep the organisms alive while NMR detects metabolomic changes. Here, both vertical and horizontal NMR coil configurations are compared. While a horizontal configuration is ideal for DMF, NMR performance was found to be sub-par and instead, a vertical-optimized single-sided stripline showed most promise. In this configuration, three organisms were monitored in vivo using 1H-13C 2D NMR. Without support from DMF droplet exchange, the organisms quickly showed signs of anoxic stress; however, with droplet exchange, this was completely suppressed. The results demonstrate that DMF can be used to maintain living organisms and holds potential for automated exposures in future. However, due to numerous limitations of vertically orientated DMF, along with space limitations in standard bore NMR spectrometers, we recommend future development be performed using a horizontal (MRI style) magnet which would eliminate practically all the drawbacks identified here.


Subject(s)
Magnetic Resonance Imaging , Microfluidics , Magnetic Resonance Spectroscopy/methods , Metabolomics/methods , Lab-On-A-Chip Devices
3.
Anal Chem ; 94(24): 8756-8765, 2022 06 21.
Article in English | MEDLINE | ID: mdl-35675504

ABSTRACT

Comprehensive multiphase-nuclear magnetic resonance (CMP-NMR) is a non-invasive approach designed to observe all phases (solutions, gels, and solids) in intact samples using a single NMR probe. Studies of dead and living organisms are important to understand processes ranging from biological growth to environmental stress. Historically, such studies have utilized 1H-based phase editing for the detection of soluble/swollen components and 1H-detected 2D NMR for metabolite assignments/screening. However, living organisms require slow spinning rates (∼500 Hz) to increase survivability, but at such low speeds, complications from water sidebands and spectral overlap from the modest chemical shift window (∼0-10 ppm) make 1H NMR challenging. Here, a novel 13C-optimized E-Free magic angle spinning CMP probe is applied to study all phases in ex vivo and in vivo samples. This probe consists of a two-coil design, with an inner single-tuned 13C coil providing a 113% increase in 13C sensitivity relative to a traditional multichannel single-CMP coil design. For organisms with a large biomass (∼0.1 g) like the Ganges River sprat (ex vivo), 13C-detected full spectral editing and 13C-detected heteronuclear correlation (HETCOR) can be performed at natural abundance. Unfortunately, for a single living shrimp (∼2 mg), 13C enrichment was still required, but 13C-detected HETCOR shows superior data relative to heteronuclear single-quantum coherence at low spinning speeds (due to complications from water sidebands in the latter). The probe is equipped with automatic-tuning-matching and is compatible with automated gradient shimming─a key step toward conducting multiphase screening of dead and living organisms under automation in the near future.


Subject(s)
Carbon , Water , Carbon Isotopes , Magnetic Resonance Spectroscopy
4.
Magn Reson Chem ; 60(3): 386-397, 2022 03.
Article in English | MEDLINE | ID: mdl-34647646

ABSTRACT

Microcoils provide a cost-effective approach to improve detection limits for mass-limited samples. Single-sided planar microcoils are advantageous in comparison to volume coils, in that the sample can simply be placed on top. However, the considerable drawback is that the RF field that is produced by the coil decreases with distance from the coil surface, which potentially limits more complex multi-pulse NMR pulse sequences. Unfortunately, 1 H NMR alone is not very informative for intact biological samples due to line broadening caused by magnetic susceptibility distortions, and 1 H-13 C 2D NMR correlations are required to provide the additional spectral dispersion for metabolic assignments in vivo or in situ. To our knowledge, double-tuned single-sided microcoils have not been applied for the 2D 1 H-13 C analysis of intact 13 C enriched biological samples. Questions include the following: Can 1 H-13 C 2D NMR be performed on single-sided planar microcoils? If so, do they still hold sensitivity advantages over conventional 5 mm NMR technology for mass limited samples? Here, 2D 1 H-13 C HSQC, HMQC, and HETCOR variants were compared and then applied to 13 C enriched broccoli seeds and Daphnia magna (water fleas). Compared to 5 mm NMR probes, the microcoils showed a sixfold improvement in mass sensitivity (albeit only for a small localized region) and allowed for the identification of metabolites in a single intact D. magna for the first time. Single-sided planar microcoils show practical benefit for 1 H-13 C NMR of intact biological samples, if localized information within ~0.7 mm of the 1 mm I.D. planar microcoil surface is of specific interest.


Subject(s)
Daphnia , Magnetic Resonance Imaging , Animals , Magnetic Resonance Spectroscopy/methods , Nuclear Magnetic Resonance, Biomolecular
5.
Anal Chem ; 93(29): 10326-10333, 2021 07 27.
Article in English | MEDLINE | ID: mdl-34259008

ABSTRACT

Comprehensive multiphase (CMP) NMR, first described in 2012, combines all of the hardware components necessary to analyze all phases (solid, gel, and solution) in samples in their natural state. In combination with spectral editing experiments, it can fully differentiate phases and study the transfer of chemical species across and between phases, providing unprecedented molecular-level information in unaltered natural systems. However, many natural samples, such as swollen soils, plants, and small organisms, contain water, salts, and ionic compounds, making them electrically lossy and susceptible to RF heating, especially when using high-strength RF fields required to select the solid domains. While dedicated reduced-heating probes have been developed for solid-state NMR, to date, all CMP-NMR probes have been based on solenoid designs, which can lead to problematic sample heating. Here, a new prototype CMP probe was developed, incorporating a loop gap resonator (LGR) for decoupling. Temperature increases are monitored in salt solutions analogous to those in small aquatic organisms and then tested in vivo on Hyalella azteca (freshwater shrimp). In the standard CMP probe (solenoid), 80% of organisms died within 4 h under high-power decoupling, while in the LGR design, all organisms survived the entire test period of 12 h. The LGR design reduced heating by a factor of ∼3, which allowed 100 kHz decoupling to be applied to salty samples with generally ≤10 °C sample heating. In addition to expanding the potential for in vivo research, the ability to apply uncompromised high-power decoupling could be beneficial for multiphase samples containing true crystalline solids that require the strongest possible decoupling fields for optimal detection.


Subject(s)
Heating , Hot Temperature , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Radio Waves
6.
Analyst ; 146(14): 4461-4472, 2021 Jul 12.
Article in English | MEDLINE | ID: mdl-34136891

ABSTRACT

Comprehensive multiphase NMR combines the ability to study and differentiate all phases (solids, gels, and liquids) using a single NMR probe. The general goal of CMP-NMR is to study intact environmental and biological samples to better understand conformation, organization, association, and transfer between and across phases/interfaces that may be lost with conventional sample preparation such as drying or solubilization. To date, all CMP-NMR studies have used 4 mm probes and rotors. Here, a larger 7 mm probehead is introduced which provides ∼3 times the volume and ∼2.4 times the signal over a 4 mm version. This offers two main advantages: (1) the additional biomass reduces experiment time, making 13C detection at natural abundance more feasible; (2) it allows the analysis of larger samples that cannot fit within a 4 mm rotor. Chicken heart tissue and Hyalella azteca (freshwater shrimp) are used to demonstrate that phase-based spectral editing works with 7 mm rotors and that the additional biomass from the larger volumes allows detection with 13C at natural abundance. Additionally, a whole pomegranate seed berry (aril) and an intact softgel capsule of hydroxyzine hydrochloride are used to demonstrate the analysis of samples too large to fit inside a conventional 4 mm CMP probe. The 7 mm version introduced here extends the range of applications and sample types that can be studied and is recommended when 4 mm CMP probes cannot provide adequate signal-to-noise (S/N), or intact samples are simply too big for 4 mm rotors.


Subject(s)
Magnetic Resonance Imaging , Biomass , Magnetic Resonance Spectroscopy
7.
Anal Chem ; 92(23): 15454-15462, 2020 12 01.
Article in English | MEDLINE | ID: mdl-33170641

ABSTRACT

The superior mass sensitivity of microcoil technology in nuclear magnetic resonance (NMR) spectroscopy provides potential for the analysis of extremely small-mass-limited samples such as eggs, cells, and tiny organisms. For optimal performance and efficiency, the size of the microcoil should be tailored to the size of the mass-limited sample of interest, which can be costly as mass-limited samples come in many shapes and sizes. Therefore, rapid and economic microcoil production methods are needed. One method with great potential is 5-axis computer numerical control (CNC) micromilling, commonly used in the jewelry industry. Most CNC milling machines are designed to process larger objects and commonly have a precision of >25 µm (making the machining of common spiral microcoils, for example, impossible). Here, a 5-axis MiRA6 CNC milling machine, specifically designed for the jewelry industry, with a 0.3 µm precision was used to produce working planar microcoils, microstrips, and novel microsensor designs, with some tested on the NMR in less than 24 h after the start of the design process. Sample wells could be built into the microsensor and could be machined at the same time as the sensors themselves, in some cases leaving a sheet of Teflon as thin as 10 µm between the sample and the sensor. This provides the freedom to produce a wide array of designs and demonstrates 5-axis CNC micromilling as a versatile tool for the rapid prototyping of NMR microsensors. This approach allowed the experimental optimization of a prototype microstrip for the analysis of two intact adult Daphnia magna organisms. In addition, a 3D volume slotted-tube resonator was produced that allowed for 2D 1H-13C NMR of D. magna neonates and exhibited 1H sensitivity (nLODω600 = 1.49 nmol s1/2) close to that of double strip lines, which themselves offer the best compromise between concentration and mass sensitivity published to date.


Subject(s)
Costs and Cost Analysis , Magnetic Resonance Spectroscopy/economics , Magnetic Resonance Spectroscopy/instrumentation , Microtechnology/instrumentation , Animals , Daphnia/chemistry , Equipment Design , Mechanical Phenomena , Time Factors
8.
J Biomol NMR ; 74(10-11): 555-563, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32533387

ABSTRACT

Fragment-based screening has evolved as a remarkable approach within the drug discovery process both in the industry and academia. Fragment screening has become a more structure-based approach to inhibitor development, but also towards development of pathway-specific clinical probes. However, it is often witnessed that the availability, immediate and long-term, of a high quality fragment-screening library is still beyond the reach of most academic laboratories. Within iNEXT (Infrastructure for NMR, EM and X-rays for Translational research), a EU-funded Horizon 2020 program, a collection of 782 fragments were assembled utilizing the concept of "poised fragments" with the aim to facilitate downstream synthesis of ligands with high affinity by fragment ligation. Herein, we describe the analytical procedure to assess the quality of this purchased and assembled fragment library by NMR spectroscopy. This quality assessment requires buffer solubility screening, comparison with LC/MS quality control and is supported by state-of-the-art software for high throughput data acquisition and on-the-fly data analysis. Results from the analysis of the library are presented as a prototype of fragment progression through the quality control process.


Subject(s)
Drug Discovery/methods , Nuclear Magnetic Resonance, Biomolecular/methods , Small Molecule Libraries/chemistry , Chromatography, Liquid , Ligands , Mass Spectrometry , Protein Binding , Quality Control , Quantitative Structure-Activity Relationship , Software , Solubility
9.
Anal Chim Acta X ; 6: 100051, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33392494

ABSTRACT

Nuclear Magnetic Resonance (NMR) spectroscopy is a non-invasive analytical technique which allows for the study of intact samples. Comprehensive Multiphase NMR (CMP-NMR) combines techniques and hardware from solution state and solid state NMR to allow for the holistic analysis of all phases (i.e. solutions, gels and solids) in unaltered samples. This study is the first to apply CMP-NMR to deceased, intact organisms and uses 13C enriched Daphnia magna (water fleas) as an example. D. magna are commonly used model organisms for environmental toxicology studies. As primary consumers, they are responsible for the transfer of nutrients across trophic levels, and a decline in their population can potentially impact the entire freshwater aquatic ecosystem. Though in vivo research is the ultimate tool to understand an organism's most biologically relevant state, studies are limited by conditions (i.e. oxygen requirements, limited experiment time and reduced spinning speed) required to keep the organisms alive, which can negatively impact the quality of the data collected. In comparison, ex vivo CMP-NMR is beneficial in that; organisms do not need oxygen (eliminating air holes in rotor caps and subsequent evaporation); samples can be spun faster, leading to improved spectral resolution; more biomass per sample can be analyzed; and experiments can be run for longer. In turn, higher quality ex vivo NMR, can provide more comprehensive NMR assignments, which in many cases could be transferred to better understand less resolved in vivo signals. This manuscript is divided into three sections: 1) multiphase spectral editing techniques, 2) detailed metabolic assignments of 2D NMR of 13C enriched D. magna and 3) multiphase biological changes over different life stages, ages and generations of D. magna. In summary, ex vivo CMP-NMR proves to be a very powerful approach to study whole organisms in a comprehensive manner and should provide very complementary information to in vivo based research.

10.
Angew Chem Int Ed Engl ; 58(43): 15372-15376, 2019 Oct 21.
Article in English | MEDLINE | ID: mdl-31449724

ABSTRACT

Microcoil nuclear magnetic resonance (NMR) has been interfaced with digital microfluidics (DMF) and is applied to monitor organic reactions in organic solvents as a proof of concept. DMF permits droplets to be moved and mixed inside the NMR spectrometer to initiate reactions while using sub-microliter volumes of reagent, opening up the potential to follow the reactions of scarce or expensive reagents. By setting up the spectrometer shims on a reagent droplet, data acquisition can be started immediately upon droplet mixing and is only limited by the rate at which NMR data can be collected, allowing the monitoring of fast reactions. Here we report a cyclohexene carbonate hydrolysis in dimethylformamide and a Knoevenagel condensation in methanol/water. This is to our knowledge the first time rapid organic reactions in organic solvents have been monitored by high field DMF-NMR. The study represents a key first step towards larger DMF-NMR arrays that could in future serve as discovery platforms, where computer controlled DMF automates mixing/titration of chemical libraries and NMR is used to study the structures formed and kinetics in real time.

11.
Toxicon ; 49(8): 1158-71, 2007 Jun 15.
Article in English | MEDLINE | ID: mdl-17391722

ABSTRACT

Bacillus amyloliquefaciens strains isolated from the indoor environment of moisture-damaged buildings produce a 1197 Da toxin, named amylosin. Nuclear magnetic resonance (NMR) data showed that amylosin contains a chromophoric polyene structure and the amino acids leucine/isoleucine, proline, aspartic acid/asparagine, glutamic acid/glutamine and tyrosine. A quantitation method for amylosin was developed using commercially available amphotericin B as a reference compound and a known concentration of amylosin determined by NMR with the electronic reference to access in vivo concentration (ERETIC) method. Purified amylosin inhibited motility of boar sperm cells at an exposure concentration of 135 nM and hyperpolarized their cell membrane and depolarized their mitochondria at exposure to concentration of 33-67 nM for 10 min. In a 3-d exposure time only 27 nM of amylosin was needed to provoke the same toxicity functions. Amylosin was cytotoxic to feline lung cells at concentrations of <170 nM. Purified amylosin provoked adenosine 5'-triphosphate (ATP)-independent cation influx into isolated rat liver mitochondria (RLM), inducing swelling of the mitochondria at concentrations of 200 nM K(+) or >250 nM Na(+) medium. In the K(+)- or Na(+)-containing medium, amylosin uncoupled RLM, causing oxidation of pyridine nucleotides (PN), loss of the mitochondrial membrane potential, and suppressed ATP synthesis. Purified amylosin produced cation channels in black-lipid membranes (BLMs) with a selectivity K(+)>Na(+) at a concentration of 26 nM, i.e. the same concentration at which amylosin was toxic to boar sperm cells. The amylosin cation channels were cholesterol- and ATP-independent and more effective with K(+) than with Na(+). We propose that the toxicity of amylosin may be due its ionophoric properties, representing the first K(+)/Na(+) channel-forming substance reported from B. amyloliquefaciens.


Subject(s)
Bacillus/chemistry , Bacterial Toxins/toxicity , Cation Transport Proteins/toxicity , Polyenes/toxicity , Adenosine Triphosphate/metabolism , Amino Acids/analysis , Animals , Bacterial Toxins/chemistry , Bacterial Toxins/isolation & purification , Cation Transport Proteins/chemistry , Cation Transport Proteins/isolation & purification , Cats , Chromatography, High Pressure Liquid , Dose-Response Relationship, Drug , Lung/drug effects , Male , Mass Spectrometry , Membrane Potential, Mitochondrial/drug effects , Microscopy, Fluorescence , Nuclear Magnetic Resonance, Biomolecular , Polyenes/chemistry , Polyenes/isolation & purification , Rats , Sperm Motility/drug effects , Sus scrofa , Toxicity Tests
12.
Analyst ; 127(5): 582-4, 2002 May.
Article in English | MEDLINE | ID: mdl-12081031

ABSTRACT

The application of a 1 mm TXI (1H/13C/15N) microlitre NMR probe with z-gradient for metabolic profiling of biofluids is described. The probe was used to provide spectral profiles for rat blood plasma using only approximately 2 microl of fluid with a range of solvent suppression techniques. Using a similar amount of fluid, spectra were obtained from rat and mouse cerebrospinal fluid, demonstrating that the probe could be used to profile rodents metabolically via biofluids previously inaccessible to NMR analysis without the need for termination.


Subject(s)
Blood Chemical Analysis , Cerebrospinal Fluid/chemistry , Animals , Hydrogen , Magnetic Resonance Spectroscopy/methods , Male , Mice , Rats
SELECTION OF CITATIONS
SEARCH DETAIL
...