J Appl Clin Med Phys ; : e14468, 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39023298

ABSTRACT

PURPOSE: Standardized and accurately reported doses are essential in conventional total body irradiation (TBI), especially lung doses. This study evaluates the accuracy of the Acuros algorithm in predicting doses for extended-distance TBI. METHODS: Measurements and calculations were done with both 6 and 18 MV. Tissue Maximum Ratio (TMR), output and off axis ratios (OAR) were measured at 200 and 500 cm source to detector distance and compared to Acuros calculated values. Two end-to-end tests were carried out, one with an in-house phantom (solid water and Styrofoam) with inserted ion chambers and the other was with the Imaging and Radiation Oncology Core (IROC) TBI anthropomorphic phantom equipped with TLDs. The end-to-end test was done for 6 and 18 MV both with and without lung blocks. The source to midplane distance for both phantoms were at 518 and 508 cm respectively. Lung blocks were placed at the phantom surface and a beam spoiler was positioned 30 cm from the surface of the phantoms as per our clinical set up. RESULTS: The agreement between measured and calculated TMR, output and off axis ratios for both 6 and 18 MV were within 2%. Ion chamber measurements in both the Styrofoam and solid water for both energies carried out with and without lung blocks were within 2% of calculated values. TLD measured doses for both 6 and 18 MV in the IROC phantom were within 5% of calculated doses which is within the uncertainty of the TLD measurement. CONCLUSIONS: The results indicate that the clinical beam model for Acuros 16.1 commissioned at standard clinical distances is capable of calculating doses accurately at extended distances up to 500 cm.

2.
Int J Radiat Oncol Biol Phys ; 117(1): 274-280, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37023988

ABSTRACT

PURPOSE: The objective of this work was to evaluate dosimetric characteristics to organs at risk (OARs) from short-course adjuvant vaginal cuff brachytherapy (VCB) in early endometrial cancer compared with standard of care (SOC) in a multi-institutional prospective randomized trial. METHODS AND MATERIALS: SAVE (Short Course Adjuvant Vaginal Brachytherapy in Early Endometrial Cancer Compared to Standard of Care) is a prospective, phase 3, multisite randomized trial in which 108 patients requiring VCB were randomized to an experimental short-course arm (11 Gy × 2 fractions [fx] to surface) and SOC arm. Those randomized to the SOC arm were subdivided into treatment groups based on treating physician discretion as follows: 7 Gy × 3 fx to 5 mm, 5 to 5.5 Gy × 4 fx to 5 mm, and 6 Gy × 5 fx to surface. To evaluate doses to OARs of each SAVE cohort, the rectum, bladder, sigmoid, small bowel, and urethra were contoured on planning computed tomography, and doses to OARs were compared by treatment arm. Absolute doses for each OAR and from each fractionation scheme were converted to 2 Gy equivalent dose (EQD23). Each SOC arm was compared with the experimental arm separately using 1-way analysis of variance, followed by pairwise comparisons using Tukey's honestly significant difference test. RESULTS: The experimental arm had significantly lower doses for rectum, bladder, sigmoid, and urethra compared with the 7 Gy × 3 and 5 to 5.5 Gy × 4 fractionation schemes; however, the experimental arm did not differ from the 6 Gy × 5 fractionation scheme. For small bowel doses, none of the SOC fractionation schemes were statistically different than the experimental. The highest EQD23 doses to the examined OARs were observed to come from the most common dose fractionation scheme of 7 Gy × 3 fx. With a short median follow-up of 1 year, there have been no isolated vaginal recurrences. CONCLUSIONS: Experimental short-course VCB of 11 Gy × 2 fx to the surface provides a comparable biologically effective dose to SOC courses. Experimental short-course VCB was found to reduce or be comparable to D2cc and D0.1cc EQD23 doses to rectum, bladder, sigmoid, small bowel, and urethra critical structures. This may translate into a comparable or lower rate of acute and late adverse effects.


Subject(s)
Brachytherapy , Endometrial Neoplasms , Female , Humans , Adjuvants, Immunologic , Brachytherapy/adverse effects , Organs at Risk , Prospective Studies , Radiometry
3.
Brachytherapy ; 21(4): 511-519, 2022.
Article in English | MEDLINE | ID: mdl-35256286

ABSTRACT

PURPOSE: Commission and treatment setup of Leipzig surface applicators, because of the steep dose gradient and lack of robust immobilization, is challenging. We aim to improve commissioning reliability by investigating the impact of detector choice on percentage depth dose (PDD) verifications, and to enhance accuracy and reproducibility in calibration/treatment setup through a simple and novel immobilization device. METHODS AND MATERIALS: PDD distributions were measured with radiochromic films, optically stimulated luminescent dosimeters (OSLDs), a diode detector, and both cylindrical and parallel plate ionization chambers. The films were aligned to the applicators in parallel and transverse orientations. PDD data from a benchmarking Monte Carlo (MC) study were compared with the measured results, where surface doses were acquired from extrapolation. To improve setup accuracy and reproducibility, a custom-designed immobilization prototype device was made with cost-effective materials using a 3D printer. RESULTS: The measured PDD data with different detectors had an overall good agreement (<±10%). The parallel plate ionization chamber reported unreliable doses for the smallest applicator. There was no remarkable dose difference between the two film setups. The two-in-one prototype device provided a rigid immobilization and a flexible positioning of the applicator. It enhanced accuracy and reproducibility in calibration and treatment setup. CONCLUSION: We recommend using radiochromic films in the transverse orientation for a reliable and efficient PDD verification. The applicator's clinical applicability has been limited by a lack of robust immobilization. We expect this economical, easy-to-use prototype device can promote the use of Leipzig applicators in surface brachytherapy.


Subject(s)
Brachytherapy , Brachytherapy/methods , Humans , Monte Carlo Method , Radiometry/methods , Radiotherapy Dosage , Reproducibility of Results
4.
Phys Med ; 80: 335-341, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33249394

ABSTRACT

PURPOSE: This work investigated effects of implementing the Delta4 Discover diode transmission detector into the clinical workflow. METHODS: PDD and profile scans were completed with and without the Discover for a number of photon beam energies. Transmission factors were determined for all beam energies and included in Eclipse TPS to account for the attenuation of the Discover. A variety of IMRT plans were delivered to a Delta4 Phantom+ with and without the Discover to evaluate the Discover's effects on IMRT QA. An imaging QA phantom was used to assess the detector's effects on MV image quality. OSLDs placed on the Phantom+ were used to determine the detector's effects on superficial dose. RESULTS: The largest effect on PDDs after dmax was 0.5%. The largest change in beam profile symmetry and flatness was 0.2% and 0.1%, respectively. An average difference in gamma passing rates (2%/2 mm) of 0.2% was observed between plans that did not include the Discover in the measurement and calculation to plans that did include the Discover in the measurement and calculation. The Discover did not significantly change the MV image quality, and the largest observed increase in the relative superficial dose when the Discover was present was 1%. CONCLUSIONS: The effects the Discover has on the linac beam were found to be minimal. The device can be implemented into the clinic without the need to alter the TPS beam modeling, other than accounting for the device's attenuation. However, a careful workflow review to implement the Discover should be completed.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Particle Accelerators , Phantoms, Imaging , Quality Assurance, Health Care , Radiometry , Radiotherapy Dosage , Workflow
5.
Sci Rep ; 7(1): 9026, 2017 08 22.
Article in English | MEDLINE | ID: mdl-28831133

ABSTRACT

Ultraviolet (UV) irradiation is an effective bacterial inactivation technique with broad applications in environmental disinfection. However, biomedical applications are limited due to the low selectivity, undesired inactivation of beneficial bacteria and damage of healthy tissue. New approaches are needed for the protection of biological cells from UV radiation for the development of controlled treatment and improved biosensors. Aluminum plasmonics offers attractive opportunities for the control of light-matter interactions in the UV range, which have not yet been explored in microbiology. Here, we investigate the effects of aluminum nanoparticles (Al NPs) prepared by sonication of aluminum foil on the UVC inactivation of E. coli bacteria and demonstrate a new radiation protection mechanism via plasmonic nanoshielding. We observe direct interaction of the bacterial cells with Al NPs and elucidate the nanoshielding mechanism via UV plasmonic resonance and nanotailing effects. Concentration and wavelength dependence studies reveal the role and range of control parameters for regulating the radiation dosage to achieve effective UVC protection. Our results provide a step towards developing improved radiation-based bacterial treatments.


Subject(s)
Aluminum/pharmacology , Disinfection/methods , Escherichia coli/growth & development , Aluminum/chemistry , Escherichia coli/drug effects , Escherichia coli/radiation effects , Metal Nanoparticles/chemistry , Microbial Viability , Sonication , Ultraviolet Rays/adverse effects
6.
Opt Express ; 25(7): 7251-7262, 2017 Apr 03.
Article in English | MEDLINE | ID: mdl-28380850

ABSTRACT

Drought stress disrupts the balance of macro- and micronutrients and affects the yield of agriculturally and economically significant plants. Rapid detection of stress-induced changes of relative content of elements such as sodium (Na), potassium (K), calcium (Ca) and iron (Fe) in the field may allow farmers and crop growers to counter the effects of plant stress and to increase their crop return. Unfortunately, the analytical methods currently available are time-consuming, expensive and involve elaborate sample preparation such as acid digestion which hinders routine daily monitoring of crop health on a field scale. We report application of an alternative method for rapid detection of drought stress in plants using femtosecond laser-induced breakdown spectroscopy (LIBS). We demonstrate daily monitoring of relative content of Na, K, Ca and Fe in decorative indoor (gardenia) and cultivated outdoor (wheat) plant species under various degrees of drought stress. The observed differences in spectral and temporal responses indicate different mechanisms of drought resistance. We identify spectroscopic markers of drought stress which allow for distinguishing mild environmental and severe drought stress in wheat and may be used for remote field-scale estimation of plant stress resistance and health.


Subject(s)
Crops, Agricultural/chemistry , Droughts , Gardenia/chemistry , Spectrum Analysis/methods , Triticum/chemistry , Calcium/analysis , Iron/analysis , Lasers , Potassium/analysis , Sodium/analysis