Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 1168-1175, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35419705

ABSTRACT

PURPOSE: The use of computer-assisted and robotic surgery was developed to improve component position and outcomes of total knee arthroplasty (TKA). The goal of this study is to identify differences in patient demographics, comorbidities, and complications between technology-assisted and conventional TKA. METHODS: A Nationwide Inpatient Sample database was used to identify patients who underwent technology-assisted and conventional TKA from 2016 to 2018. Analysed variables include demographics, length of stay (LOS), payer-status, geographic region, comorbidities, complications, and mortality. Univariate and multivariate analyses were performed to identify differences between both groups. RESULTS: The analysis includes 2,208,434 TKA patients, of which 2,054,879 (93.05%) were conventional and 153,555 (6.95%) were technology assisted. Patients undergoing technology-assisted TKA were more likely to be older than 65 years, had higher median income quartile, and had surgery in urban teaching hospitals. Patients were less likely to undergo technology-assisted TKA if they were female gender, had Medicare payer status, were black race, were obese, were living in rural location, or had higher Charlson comorbidity score and baseline comorbidities. Technology-assisted TKA patients had shorter LOS, and fewer pulmonary and infection complications. CONCLUSION: Patients undergoing technology-assisted TKA are being carefully selected with less baseline comorbidities, improved health, and living in urban areas. Subsequently, those carefully selected patients are discharged home, have a shorted hospital LOS, and have fewer complications compared to conventional TKA. Rural patients, black race and female gender are less likely to undergo technology-assisted TKA, further emphasizing the healthcare disparity for that segment of the population. LEVEL OF EVIDENCE: Therapeutic level III.


Subject(s)
Arthroplasty, Replacement, Knee , Humans , Female , Aged , United States , Male , Arthroplasty, Replacement, Knee/adverse effects , Risk Factors , Medicare , Postoperative Complications/etiology , Comorbidity , Length of Stay
2.
J Am Acad Orthop Surg ; 31(2): e107-e117, 2023 Jan 15.
Article in English | MEDLINE | ID: mdl-36580056

ABSTRACT

INTRODUCTION: Perioperative cefazolin administration for total joint arthroplasty is a first-line antibiotic recommended by the American Academy of Orthopaedic Surgeons (AAOS) guidelines for the prevention of periprosthetic joint infections (PJIs). We aim to analyze the clinical viability of giving patients with a documented penicillin allergy (PA) a perioperative full-strength cefazolin "test dose" under anesthesia. METHODS: This is a retrospective chart review of 2,451 total joint arthroplasties from a high-volume arthroplasty orthopaedic surgeon over a 5-year period from January 2013 through December 2017. This surgeon routinely gave patients with a documented PA a full-strength cefazolin test dose while under anesthesia instead of administrating a second-line antibiotic. The primary outcomes examined were allergic reaction and postoperative infection. RESULTS: Cefazolin was given to 87.1% of all patients (1,990) and 46.0% of patients with a PA (143). The total rate of allergic reactions among all patients was 0.5% (11). Only one patient with a documented PA who received cefazolin had an allergic reaction. The reaction was not severe and did not require any additional treatment. In patients who had no reported allergies and received cefazolin, 0.3% (6) had an allergic reaction. There was no statistically significant difference in the rate of allergic reaction when comparing patients with and without a PA (P = 0.95). Patients receiving cefazolin had an overall PJI rate of 2.9% (57) versus those patients receiving antibiotics other than cefazolin who sustained a 5.5% PJI rate (16), which was statistically significant (P = 0.02). CONCLUSION: This study found that utilization of a full-strength test dose of cefazolin in patients with a documented PA is a feasible, safe, and effective way of increasing the rate of cefazolin administration and thus mitigating the risk of PJIs.


Subject(s)
Arthritis, Infectious , Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Drug Hypersensitivity , Hypersensitivity , Prosthesis-Related Infections , Humans , Cefazolin , Arthroplasty, Replacement, Knee/adverse effects , Retrospective Studies , Antibiotic Prophylaxis , Anti-Bacterial Agents , Penicillins/adverse effects , Drug Hypersensitivity/etiology , Drug Hypersensitivity/prevention & control , Arthritis, Infectious/etiology , Arthritis, Infectious/prevention & control , Hypersensitivity/etiology , Arthroplasty, Replacement, Hip/adverse effects , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/prevention & control , Prosthesis-Related Infections/drug therapy
3.
Arthroplast Today ; 6(4): 644-649, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32875012

ABSTRACT

BACKGROUND: Varus malposition is a risk of early failure in total hip arthroplasty. The degree to which the tip of the greater trochanter (GT) overhangs the canal can increase this risk. Although we know proximal femoral anatomy is variable, no study has addressed variations in medial overhang of the GT on plain radiographs. METHODS: All low anteroposterior pelvis radiographs more than 1 year were reviewed 3 times by 2 orthopaedic surgeons and one radiologist. The canal width (CW) was measured 10 cm below the lesser trochanter. Canal overhang (CO) was defined by the distance between the lateral medullary canal and a parallel line beginning at the most medial aspect of the GT. The overhang index (OI) is defined as the percentage of the canal overhung by the GT. RESULTS: The mean CW was 13.5 mm, mean CO 16.4 mm, and mean OI 1.22. Hips were then classified as the following: (A) OI < 0.5 (n = 8), (B) OI 0.5-1.0 (n = 78), (C) OI 1.0-1.5 (n = 191), and (D) OI > 1.5 (n = 68). Intraobserver reliability was excellent for all measures: 0.89 (confidence interval: 0.87-0.91) for CW, 0.96 (0.95-0.97) for CO, and 0.97 (0.97-0.98) for OI. Interobserver reliability was good for CW 0.75 (0.70-0.79) and excellent for CO 0.90 (0.88-0.92) and OI 0.95 (0.94-0.96). CONCLUSIONS: Variations in the morphology of the proximal femur can predispose to varus component malposition. The degree to which the GT overhangs the canal can be quantified and classified based on plain films. This can aid in preoperative planning and help guide intraoperative proximal femoral preparation.

SELECTION OF CITATIONS
SEARCH DETAIL
...