Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57
Filter
1.
Herz ; 2024 May 06.
Article in German | MEDLINE | ID: mdl-38709278

ABSTRACT

Cardiac device therapy provides not only treatment options for bradyarrhythmia but also advanced treatment for heart failure and preventive measures against sudden cardiac death. In heart failure treatment it enables synergistic reverse remodelling and reduces pharmacological side effects. Cardiac resynchronization therapy (CRT) has revolutionized the treatment of reduced left ventricular ejection fraction (LVEF) and left bundle branch block by decreasing the mortality and morbidity with improvement of the quality of life and resilience. Conduction system pacing (CSP) as an alternative method of physiological stimulation can improve heart function and reduce the risk of pacemaker-induced cardiomyopathy. Leadless pacers and subcutaneous/extravascular defibrillators offer less invasive options with lower complication rates. The prevention of infections through preoperative and postoperative strategies enhances the safety of these therapies.

2.
Europace ; 2024 May 02.
Article in English | MEDLINE | ID: mdl-38696701

ABSTRACT

BACKGROUND AND AIMS: Women have been historically underrepresented in implantable cardioverter defibrillator (ICD) trials. No data on sex differences regarding subcutaneous-ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS: Consecutive patients enrolled in the multicenter, international i-SUSI registry were analyzed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. RESULTS: A total of 1698 patients were extracted from the iSUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analyzed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs 81.3%, p = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4%vs1.7%; log-rank p = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs 5.8%; log-rank p = 0.595) and inappropriate shocks (rate/year: 4.3%vs3.1%; log-rank p = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, p = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device related-complications.

3.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584394

ABSTRACT

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Arrhythmias, Cardiac/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electric Countershock/adverse effects , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
4.
Heart Rhythm ; 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38336193

ABSTRACT

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

5.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38246594

ABSTRACT

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Cardiomyopathy, Dilated , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Electric Countershock/adverse effects , Arrhythmogenic Right Ventricular Dysplasia/complications , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/therapy , Registries , Treatment Outcome
6.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38272130

ABSTRACT

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Subject(s)
Defibrillators, Implantable , Heart Failure , Heart-Assist Devices , Pacemaker, Artificial , Adult , Female , Humans , Male , Middle Aged , Defibrillators, Implantable/adverse effects , Electric Countershock/adverse effects , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/complications , Heart-Assist Devices/adverse effects , Pacemaker, Artificial/adverse effects , Treatment Outcome
8.
Sci Rep ; 12(1): 20504, 2022 11 28.
Article in English | MEDLINE | ID: mdl-36443407

ABSTRACT

We hypothesized that myocardial septal scarring, assessed by cardiac magnetic resonance (CMR) using late gadolinium enhancement (LGE), at the site of cardiac contractility modulation (CCM) lead placement may predict treatment response. Eligible heart failure (HF) patients underwent LGE CMR imaging before CCM device implantation. The response to CCM therapy at follow-up was determined by a change in NYHA class and echocardiographic left ventricular ejection fraction (LVEF) assessment. Patients were classified as responders, if they showed an improvement in either NYHA class or improvement of LVEF by ≥ 5%. 58 patients were included. 67% of patients were classified as responders according to improved NYHA; 55% according to LVEF improvement. 74% of patients were responders if either NYHA class or LVEF improvement was observed. 90% of responders (according to NYHA class) showed septal LGE < 25% at septal position of the leads, while 44% of non-responders showed septal LGE > 25% (p < 0.01). In patients treated with CCM, an improvement of NYHA class was observed when leads were placed at myocardial segments with a CMR- LGE burden less than 25%.


Subject(s)
Cicatrix , Heart Failure , Humans , Cicatrix/diagnostic imaging , Stroke Volume , Contrast Media , Ventricular Function, Left , Gadolinium , Heart Failure/diagnostic imaging , Heart Failure/therapy
9.
Heart Rhythm ; 19(12): 1958-1964, 2022 12.
Article in English | MEDLINE | ID: mdl-35781042

ABSTRACT

BACKGROUND: The absence of pacing capabilities may reduce the appeal of subcutaneous implantable cardioverter-defibrillator (S-ICD) devices for patients at risk for conduction disorders or with antitachycardia pacing (ATP)/cardiac resynchronization (CRT) requirements. Reports of rates of S-ICD to transvenous implantable cardioverter-defibrillator (TV-ICD) system switch in real-world scenarios are limited. OBJECTIVE: The purpose of this study was to investigate the need for a subsequent transvenous (TV) device in patients implanted with an S-ICD and its predictors. METHODS: All patients implanted with an S-ICD were enrolled from the multicenter, real-world iSUSI (International SUbcutaneouS Implantable cardioverter defibrillator) Registry. The need for a TV device and its clinical reason, and appropriate and inappropriate device therapies were assessed. Logistic regression with Firth penalization was used to assess the association between baseline and procedural characteristics and the overall need for a subsequent TV device. RESULTS: A total of 1509 patients were enrolled (age 50.8 ± 15.8 years; 76.9% male; 32.0% ischemic; left ventricular ejection fraction 38% [30%-60%]). Over 26.5 [13.4-42.9] months, 155 (10.3%) and 144 (9.3%) patients experienced appropriate and inappropriate device therapies, respectively. Forty-one patients (2.7%) required a TV device (13 bradycardia; 10 need for CRT; 10 inappropriate shocks). Body mass index (BMI) >30 kg/m2 and chronic kidney disease (CKD) were associated with need for a TV device (odds ratio [OR] 2.57 [1.37-4.81], P = .003; and OR 2.67 [1.29-5.54], P = .008, respectively). CONCLUSION: A low rate (2.7%) of conversion from S-ICD to a TV device was observed at follow-up, with need for antibradycardia pacing, ATP, or CRT being the main reasons. BMI >30 kg/m2 and CKD predicted all-cause need for a TV device.


Subject(s)
Defibrillators, Implantable , Renal Insufficiency, Chronic , Humans , Male , Adult , Middle Aged , Aged , Female , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Stroke Volume , Retrospective Studies , Treatment Outcome , Ventricular Function, Left , Adenosine Triphosphate
10.
Pacing Clin Electrophysiol ; 45(5): 639-648, 2022 05.
Article in English | MEDLINE | ID: mdl-35262210

ABSTRACT

BACKGROUND: Cardiac contractility modulation (CCM), being reserved for patients with symptomatic chronic heart failure (HF) and narrow QRS complex under guideline directed medical therapy, can recover initially reduced left ventricular ejection fraction (LVEF); however, the influence of pre-implantation LVEF on long-term outcomes is not fully understood. This study aimed to compare the effects of lower and higher preimplantation LVEF on long-term outcomes in CCM-therapy. METHODS: One-hundred seventy-two patients from our single-centre registry were retrospectively included (2002-2019). Follow-up data were collected up to 5 years after implantation. Patients were divided into Group 1 (baseline LVEF≤ 30%) and Group 2 (≥ 31%). Both groups were compared based on differences in survival, echocardiographic- and clinical parameters including LVEF, tricuspid annular plane systolic excursion (TAPSE), NYHA class or Minnesota living with heart failure questionnaire-score (MLWHFQ). RESULTS: 11% of the patients did have a LVEF ≥31%. Mean LVEF ± SD for both groups were 21.98 ± 5.4 versus 35.2 ± 3.7%, respectively. MLWHFQ (47 ± 21.2 vs. 42±21.4) and mean peak oxygen consumption (VO2, 13.6 ± 4.1 vs. 12.7 ± 2.8 ml/kg/min) were comparable between both groups. LVEF-grouping did not influence survival. Lower baseline LVEF resulted in significantly better recovery of echocardiographic parameters such as LVEF and TAPSE. Irrespective from baseline LVEF, both groups showed nearly comparable improvements for clinical parameters like NYHA-class and MLWHFQ. CONCLUSION: Long-term biventricular systolic recovery potential in CCM-therapy might be better for preimplantation LVEF values ≤30%, whereas clinical parameters such as NYHA-class can improve irrespective from baseline LVEF.


Subject(s)
Heart Failure , Ventricular Function, Left , Anti-Arrhythmia Agents , Heart Failure/therapy , Humans , Myocardial Contraction , Retrospective Studies , Stroke Volume , Treatment Outcome
11.
Heart Rhythm ; 19(7): 1109-1115, 2022 07.
Article in English | MEDLINE | ID: mdl-35257974

ABSTRACT

BACKGROUND: A few limited case series have shown that the subcutaneous implantable cardioverter-defibrillator (S-ICD) system is safe for teenagers and young adults, but a large-scale analysis currently is lacking. OBJECTIVES: The purpose of this study was to compare mid-term device-associated outcomes in a large real-world cohort of S-ICD patients, stratified by age at implantation. METHODS: Two propensity-matched cohorts of teenagers + young adults (≤30 years old) and adults (>30 years old) were retrieved from the ELISIR Registry. The primary outcome was the comparison of inappropriate shock rate. Complications, freedom from sustained ventricular arrhythmias, and overall and cardiovascular mortality were deemed secondary outcomes. RESULTS: Teenagers + young adults represented 11.0% of the entire cohort. Two propensity-matched groups of 161 patients each were used for the analysis. Median follow-up was 23.1 (13.2-40.5) months. In total, 15.2% patients experienced inappropriate shocks, and 9.3% device-related complications were observed, with no age-related differences in inappropriate shocks (16.1% vs 14.3%; P = .642) and complication rates (9.9% vs 8.7%; P = .701). At univariate analysis, young age was not associated with increased rates of inappropriate shocks (hazard ratio [HR] 1.204 [0.675-2.148]: P = .529). At multivariate analysis, use of the SMART Pass algorithm was associated with a strong reduction in inappropriate shocks (adjusted HR 0.292 [0.161-0.525]; P <.001), whereas arrhythmogenic right ventricular cardiomyopathy (ARVC) was associated with higher rates of inappropriate shocks (adjusted HR 2.380 [1.205-4.697]; P = .012). CONCLUSION: In a large multicenter registry of propensity-matched patients, use of the S-ICD in teenagers/young adults was safe and effective. The rates of inappropriate shocks and complications between cohorts were not significantly different. The only predictor of increased inappropriate shocks was a diagnosis of ARVC.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Defibrillators, Implantable , Adolescent , Adult , Arrhythmias, Cardiac/diagnosis , Arrhythmogenic Right Ventricular Dysplasia/etiology , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Humans , Registries , Treatment Outcome , Young Adult
12.
Sci Rep ; 12(1): 3203, 2022 02 25.
Article in English | MEDLINE | ID: mdl-35217697

ABSTRACT

Patients at high risk for sudden cardiac death (SCD) may benefit from wearable cardioverter defibrillators (WCD) by avoiding immediate implantable cardioverter defibrillator (ICD) implantation. Different factors play an important role including patient selection, compliance and optimal drug treatment. We aimed to present real world data from 4 centers from Germany and Switzerland. Between 04/2012 and 03/2019, 708 patients were included in this registry. Patients were followed up over a mean time of 28 ± 35.5 months. Outcome data including gender differences and different etiologies of cardiomyopathy were analyzed. Out of 708 patients (81.8% males, mean age 61.0 ± 14.6), 44.6% of patients had non-ischemic cardiomyopathy, 39.8% ischemic cardiomyopathy, 7.9% myocarditis, 5.4% prior need for ICD explantation and 2.1% channelopathy. The mean wear time of WCD was 21.2 ± 4.3 h per day. In 46% of patients, left ventricular ejection fraction (LVEF) was > 35% during follow-up. The younger the patient was, the higher the LVEF and the lower the wear hours per day were. The total shock rate during follow-up was 2.7%. Whereas an appropriate WCD shock was documented in 16 patients (2.2%), 3 patients received an inappropriate ICD shock (0.5%). During follow-up, implantation of a cardiac implantable electronic device was carried out in 34.5% of patients. When comparing German patients (n = 516) to Swiss patients (n = 192), Swiss patients presented with longer wear days (70.72 ± 49.47 days versus 58.06 ± 40.45 days; p = 0.001) and a higher ICD implantation rate compared to German patients (48.4% versus 29.3%; p = 0.001), although LVEF at follow-up was similar between both groups. Young age is a negative independent predictor for the compliance in this large registry. The most common indication for WCD was non-ischemic cardiomyopathy followed by ischemic cardiomyopathy. The compliance rate was generally high with a decrease of wear hours per day at younger age. Slight differences were found between Swiss and German patients, which might be related to differences in mentality for ICD implantation.


Subject(s)
Cardiomyopathies , Defibrillators, Implantable , Myocardial Ischemia , Wearable Electronic Devices , Aged , Cardiomyopathies/complications , Cardiomyopathies/therapy , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators/adverse effects , Defibrillators, Implantable/adverse effects , Electric Countershock , Female , Humans , Male , Middle Aged , Myocardial Ischemia/complications , Registries , Stroke Volume , Ventricular Function, Left , Wearable Electronic Devices/adverse effects
13.
ESC Heart Fail ; 9(1): 574-584, 2022 02.
Article in English | MEDLINE | ID: mdl-34818694

ABSTRACT

AIMS: The aim of this study was to evaluate the prognostic value of feature tracking (FT) derived cardiac magnetic resonance (CMR) strain parameters of the left ventricle (LV)/right ventricle (RV) in ischaemic cardiomyopathy (ICM) patients treated with an implantable cardioverter-defibrillator (ICD). Current guidelines suggest a LV-ejection fraction ≤35% as major criterion for ICD implantation in ICM, but this is a poor predictor for arrhythmic events. Supplementary parameters are missing. METHODS AND RESULTS: Ischaemic cardiomyopathy patients (n = 242), who underwent CMR imaging prior to primary and secondary implantation of ICD, were classified depending on EF ≤ 35% (n = 188) or >35% (n = 54). FT parameters were derived from steady-state free precession cine views using dedicated software. The primary endpoint was a composite of cardiovascular mortality (CVM) and/or appropriate ICD therapy. There were no significant differences in FT-function or LV-/RV-function parameters in patients with an EF ≤ 35% correlating to the primary endpoint. In patients with EF > 35%, standard CMR functional parameters, such as LV-EF, did not reveal significant differences. However, significant differences in most FT parameters correlating to the primary endpoint were observed in this subgroup. LV-GLS (left ventricular-global longitudinal strain) and RV-GRS (right ventricular-global radial strain) revealed the best diagnostic performance in ROC curve analysis. The combination of LV-GLS and RV-GRS showed a sensitivity of 85% and a specificity of 76% for the prediction of future events. CONCLUSIONS: The impact of FT derived measurements in the risk stratification of patients with ICM depends on LV function. The combination of LV-GLS/RV-GRS seems to be a predictor of cardiovascular mortality and/or appropriate ICD therapy in patients with EF > 35%.


Subject(s)
Cardiomyopathies , Magnetic Resonance Imaging, Cine , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Humans , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Spectroscopy , Stroke Volume , Ventricular Function, Left
14.
J Clin Med ; 10(21)2021 Oct 27.
Article in English | MEDLINE | ID: mdl-34768510

ABSTRACT

BACKGROUND: The angiotensin receptor-neprilysin inhibitor (ARNI) decreases cardiovascular mortality in patients with chronic heart failure with a reduced ejection fraction (HFrEF). Data regarding the impact of ARNI on the outcome in HFrEF patients according to heart failure etiology are limited. METHODS AND RESULTS: One hundred twenty-one consecutive patients with HFrEF from the years 2016 to 2017 were included at the Medical Centre Mannheim Heidelberg University and treated with ARNI according to the current guidelines. Left ventricular ejection fraction (LVEF) was numerically improved during the treatment with ARNI in both patient groups, that with ischemic cardiomyopathy (n = 61) (ICMP), and that with non-ischemic cardiomyopathy (n = 60) (NICMP); p = 0.25. Consistent with this data, the NT-proBNP decreased in both groups, more commonly in the NICMP patient group. In addition, the glomerular filtration rate (GFR) and creatinine changed before and after the treatment with ARNI in both groups. In a one-year follow-up, the rate of ventricular tachyarrhythmias (ventricular tachycardia and ventricular fibrillation) tended to be higher in the ICMP group compared with the NICMP group (ICMP 38.71% vs. NICMP 17.24%; p = 0.07). The rate of one-year all-cause mortality was similar in both groups (ICMP 6.5% vs. NICMP 6.6%; log-rank = 0.9947). CONCLUSIONS: This study shows that, although the treatment with ARNI improves the LVEF in ICMP and NICMP patients, the risk of ventricular tachyarrhythmias remains higher in ICMP patients in comparison with NICMP patients. Renal function is improved in the NICMP group after the treatment. Long-term mortality is similar over a one-year follow-up.

15.
Eur J Heart Fail ; 23(7): 1160-1169, 2021 07.
Article in English | MEDLINE | ID: mdl-34002440

ABSTRACT

AIMS: We assessed long-term effects of cardiac contractility modulation delivered by the Optimizer Smart system on quality of life, left ventricular ejection fraction (LVEF), mortality and heart failure and cardiovascular hospitalizations. METHODS AND RESULTS: CCM-REG is a prospective registry study including 503 patients from 51 European centres. Effects were evaluated in three terciles of LVEF (≤25%, 26-34% and ≥35%) and in patients with atrial fibrillation (AF) and normal sinus rhythm (NSR). Hospitalization rates were compared using a chi-square test. Changes in functional parameters of New York Heart Association (NYHA) class, Minnesota Living with Heart Failure Questionnaire (MLWHFQ) and LVEF were assessed with Wilcoxon signed-rank test, and event-free survival by Kaplan-Meier analysis. For the entire cohort and each subgroup, NYHA class and MLWHFQ improved at 6, 12, 18 and 24 months (P < 0.0001). At 24 months, NYHA class, MLWHFQ and LVEF showed an average improvement of 0.6 ± 0.7, 10 ± 21 and 5.6 ± 8.4%, respectively (all P < 0.001). LVEF improved in the entire cohort and in the LVEF ≤25% subgroup with AF and NSR. In the overall cohort, heart failure hospitalizations decreased from 0.74 [95% confidence interval (CI) 0.66-0.82] prior to enrolment to 0.25 (95% CI 0.21-0.28) events per patient-year during 2-year follow-up (P < 0.0001). Cardiovascular hospitalizations decreased from 1.04 (95% CI 0.95-1.13) events per patient-year prior to enrolment to 0.39 (95% CI 0.35-0.44) events per patient-year during 2-year follow-up (P < 0.0001). Similar reductions of hospitalization rates were observed in the LVEF, AF and NSR subgroups. Estimated survival was significantly better than predicted by MAGGIC at 1 and 3 years in the entire cohort and in the LVEF 26-34% and ≥35% subgroups. CONCLUSIONS: Cardiac contractility modulation therapy improved functional status, quality of life, LVEF and, compared to patients' prior history, reduced heart failure hospitalization rates. Survival at 1 and 3 years was significantly better than predicted by the MAGGIC risk score.


Subject(s)
Heart Failure , Quality of Life , Heart Failure/epidemiology , Heart Failure/therapy , Humans , Stroke Volume , Treatment Outcome , Ventricular Function, Left
16.
Future Cardiol ; 17(6): 1131-1142, 2021 09.
Article in English | MEDLINE | ID: mdl-33733830

ABSTRACT

The treatment with sacubitril/valsartan in patients suffering from chronic heart failure with reduced ejection fraction increases left ventricular ejection fraction and decreases the risk of sudden cardiac death. We conducted a retrospective analysis regarding the impact of age differences on the treatment outcome of sacubitril/valsartan in patients with chronic heart failure with reduced ejection fraction. Patients were defined as adults if ≤65 years (n = 51) and older if >65 years of age (n = 76). The incidence of ventricular arrhythmias at 1-year follow-up was comparable in both groups (30.8 vs 26.5%; p = 0.71). The mortality rate in adult patients is significantly lower as compared with older patients (2 vs 14.5%; log-rank = 0.04). Older patients may suffer remarkably more side effects than adult patients (21.1 vs 11.8%; p = 0.03).


Lay abstract Many patients still die from heart failure (HF). Better drugs for this condition were developed over the past 20 years. The drug combination sacubitril/valsartan improves heart function and might lower the risk of sudden cardiac death from a fast heart rate (ventricular arrythmia). More research is needed on the effect of sacubitril/valsartan on older patients with HF. We wanted to see how sacubitril/valsartan affects older patients with HF. Seventy-six patients above 65 years of age were compared with 51 patients below 65 years. A year later, the number of ventricular arrhythmias was similar in both groups. Side effects were more common in older patients. At 2 years, there were more deaths in the older group. In summary, side effects of sacubitril/valsartan could be an obstacle to treating older patients. Finding better concepts to treat older patients with a weak heart remains necessary.


Subject(s)
Heart Failure , Ventricular Function, Left , Adult , Aminobutyrates/therapeutic use , Angiotensin Receptor Antagonists/therapeutic use , Biphenyl Compounds , Drug Combinations , Heart Failure/drug therapy , Heart Failure/epidemiology , Humans , Prognosis , Retrospective Studies , Stroke Volume , Tetrazoles/therapeutic use , Treatment Outcome , Valsartan
17.
Heart Rhythm ; 18(6): 954-961, 2021 06.
Article in English | MEDLINE | ID: mdl-33515714

ABSTRACT

BACKGROUND: Only a minority of patients who receive an implantable cardioverter-defibrillator (ICD) on the basis of left ventricular ejection fraction receive appropriate ICD therapy. Peri-infarct scar zone assessed by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) is a possible substrate for ventricular tachyarrhytmias (VTAs). OBJECTIVE: The aim of our prospective study was to determine whether LGE-CMR parameters can predict the occurrence of VTA in patients with ischemic cardiomyopathy (ICM). METHODS: Two hundred sixteen patients with ICM underwent CMR imaging before primary or secondary ICD implantation and were prospectively followed. We assessed CMR indices and CMR scar characteristics (infarct core and peri-infarct zone) to predict outcome and VTAs. RESULTS: Patients were followed up for 1497 days (interquartile range 697-2237 days). Forty-seven patients (21%) received appropriate therapy during follow-up. Patients with appropriate ICD therapy had smaller core scar (31.5% ± 8.5% vs 36.8% ± 8.9%; P = .0004) but larger peri-infarct scar (12.4% ± 2.6% vs 10.5% ± 2.9%; P = .0001) than did patients without appropriate therapy. In multivariate Cox regression analysis, peri-infarct scar (hazard ratio 1.15; 95% confidence interval 1.07-1.24; P = .0001) was independently and significantly associated with VTAs whereas left ventricular ejection fraction, right ventricular ejection fraction, core scar, and left atrial ejection fraction were not. CONCLUSION: Scar extent of peri-infarct border zone was significantly associated with appropriate ICD therapy. Thus, LGE-CMR parameters can identify a subgroup of patients with ICM and an increased risk of life-threatening VTAs.


Subject(s)
Cardiomyopathies/diagnosis , Cicatrix/pathology , Gadolinium/pharmacology , Magnetic Resonance Imaging, Cine/methods , Myocardial Ischemia/diagnosis , Cardiomyopathies/complications , Cardiomyopathies/physiopathology , Cicatrix/etiology , Contrast Media/pharmacology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Myocardial Ischemia/complications , Myocardial Ischemia/physiopathology , Prospective Studies , Ventricular Function, Left/physiology , Ventricular Function, Right/physiology
18.
Int J Cardiol ; 323: 100-105, 2021 01 15.
Article in English | MEDLINE | ID: mdl-32871189

ABSTRACT

BACKGROUND: Inherited arrhythmia syndromes and genetic cardiomyopathies attribute in a significant proportion to sudden cardiac death. Implantable cardioverter defibrillators (ICDs) are the cornerstone in the prevention of sudden death in high-risk patients. However, ICD therapy is also associated with high rates of inappropriate shocks and/or device-related complications especially in young patients. OBJECTIVE: To determine the outcome of high-risk patients with inherited arrhythmia syndromes and genetic cardiomyopathies comparing two defibrillator technologies. METHOD: Between 2010 and 2018, 183 consecutive patients from two large German tertiary care centers were enrolled in the study. The majority of patients (83%) had either cardiac channelopathies or idiopathic ventricular fibrillation without cardiac structural abnormalities, while the remaining 17% had a genetic cardiomyopathy (HCM/ARVC). Eighty-six patients (47%) received a transvenous ICD (TV-ICD), while a subcutaneous ICD (S-ICD) was implanted in another 97 patients (53%). RESULTS: During a mean follow-up of 4.3 years, 30 patients had an appropriate ICD therapy (annual rate 3.8%). Fifteen patients experienced an inappropriate shock (annual rate 1.9%). Lead failure occurred in 17 (9%) patients and was less frequent in the S-ICD group (OR 0.48, 95%CI 0.38-0.62). Adverse defibrillator events, defined as a composite of inappropriate shocks and lead failure requiring surgical revision were significantly lower in the S-ICD group as compared to the TV-ICD group (OR 0.55, 95%CI 0.41-0.72). There was a non-significant trend towards lower appropriate shocks in the S-ICD group, that in combination with all-cause shocks yielded in a significantly higher freedom of any shock in the S-ICD group (RR 39%, p = 0.003). No deaths occurred during follow-up. CONCLUSION: The present data favor the use of the subcutaneous ICD for patients with inherited arrhythmia syndromes and genetic cardiomyopathies who do not need anti-bradycardia pacing.


Subject(s)
Cardiomyopathies , Defibrillators, Implantable , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/genetics , Arrhythmias, Cardiac/therapy , Cardiomyopathies/genetics , Cardiomyopathies/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Humans , Syndrome , Treatment Outcome
19.
In Vivo ; 34(6): 3601-3610, 2020.
Article in English | MEDLINE | ID: mdl-33144474

ABSTRACT

BACKGROUND/AIM: The wearable cardioverter/defibrillator (WCD) is recommended to prevent sudden cardiac death (SCD). Guidelines suggest a 90 days' period, but prolongation of WCD wear time until increasing the ejection fraction (≥35%) might be suggested. PATIENTS AND METHODS: A cohort of 153 patients with prescribed WCD were divided into two groups: A <90 wear days' group (n=112) vs. ≥90 wear days' group (n=41) and followed. RESULTS: In the first group, WCD shock occurred in 3.6% of patients, 47.3% improved in left ventricular ejection fraction (LVEF) after 3 months, and 37.5% had a cardiac implantable electronic device (CIED) implantation with appropriate implantable cardioverter defibrillator (ICD) shock events occurring in 6 patients. Two of these patients already received WCD shock therapy due to ventricular fibrillation. A 20.5% improved in LVEF after 6-12 months, but 73% were already implanted with ICD. In the second group, 4.9% received WCD shock, 34.1% improved in LVEF after 3 months, 48.8% were implanted with ICD, and 2 had ICD shocks during follow up time. LVEF improvement after 6-12 months occurred in 26.8%. ICD implantation was prevented in 7.3% of patients due to LVEF recovery. CONCLUSION: Prolonging wearing days of WCD may reduce the number of inappropriate ICD implantation.


Subject(s)
Ventricular Function, Left , Wearable Electronic Devices , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Electric Countershock , Humans , Stroke Volume
20.
N Engl J Med ; 383(6): 526-536, 2020 08 06.
Article in English | MEDLINE | ID: mdl-32757521

ABSTRACT

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).


Subject(s)
Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/adverse effects , Aged , Cardiomyopathies/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Electrodes, Implanted/adverse effects , Equipment Failure , Female , Follow-Up Studies , Heart Diseases/therapy , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL
...