Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-37502671

ABSTRACT

The advent of technological developments is allowing to gather large amounts of data in several research fields. Learning analytics (LA)/educational data mining has access to big observational unstructured data captured from educational settings and relies mostly on unsupervised machine learning (ML) algorithms to make sense of such type of data. Generalized additive models for location, scale, and shape (GAMLSS) are a supervised statistical learning framework that allows modeling all the parameters of the distribution of the response variable with respect to the explanatory variables. This article overviews the power and flexibility of GAMLSS in relation to some ML techniques. Also, GAMLSS' capability to be tailored toward causality via causal regularization is briefly commented. This overview is illustrated via a data set from the field of LA. This article is categorized under:Application Areas > Education and LearningAlgorithmic Development > StatisticsTechnologies > Machine Learning.

2.
Sci Data ; 4: 170171, 2017 11 28.
Article in English | MEDLINE | ID: mdl-29182599

ABSTRACT

Learning Analytics focuses on the collection and analysis of learners' data to improve their learning experience by providing informed guidance and to optimise learning materials. To support the research in this area we have developed a dataset, containing data from courses presented at the Open University (OU). What makes the dataset unique is the fact that it contains demographic data together with aggregated clickstream data of students' interactions in the Virtual Learning Environment (VLE). This enables the analysis of student behaviour, represented by their actions. The dataset contains the information about 22 courses, 32,593 students, their assessment results, and logs of their interactions with the VLE represented by daily summaries of student clicks (10,655,280 entries). The dataset is freely available at https://analyse.kmi.open.ac.uk/open_dataset under a CC-BY 4.0 license.

3.
PLoS One ; 9(6): e98450, 2014.
Article in English | MEDLINE | ID: mdl-24905359

ABSTRACT

We have developed a method focusing on ECG signal de-noising using Independent component analysis (ICA). This approach combines JADE source separation and binary decision tree for identification and subsequent ECG noise removal. In order to to test the efficiency of this method comparison to standard filtering a wavelet- based de-noising method was used. Freely data available at Physionet medical data storage were evaluated. Evaluation criteria was root mean square error (RMSE) between original ECG and filtered data contaminated with artificial noise. Proposed algorithm achieved comparable result in terms of standard noises (power line interference, base line wander, EMG), but noticeably significantly better results were achieved when uncommon noise (electrode cable movement artefact) were compared.


Subject(s)
Electrocardiography, Ambulatory/methods , Signal-To-Noise Ratio , Algorithms , Data Interpretation, Statistical , Decision Trees , Principal Component Analysis
4.
Article in English | MEDLINE | ID: mdl-25570833

ABSTRACT

This paper explores differences between two methods for blind source separation within frame of ECG de-noising. First method is joint approximate diagonalization of eigenmatrices, which is based on estimation of fourth order cross-cummulant tensor and its diagonalization. Second one is the statistical method known as canonical correlation analysis, which is based on estimation of correlation matrices between two multidimensional variables. Both methods were used within method, which combines the blind source separation algorithm with decision tree. The evaluation was made on large database of 382 long-term ECG signals and the results were examined. Biggest difference was found in results of 50 Hz power line interference where the CCA algorithm completely failed. Thus main power of CCA lies in estimation of unstructured noise within ECG. JADE algorithm has larger computational complexity thus the CCA perfomed faster when estimating the components.


Subject(s)
Electrocardiography , Algorithms , Artifacts , Humans , Signal Processing, Computer-Assisted , Signal-To-Noise Ratio
5.
Med Eng Phys ; 35(6): 704-11, 2013 Jun.
Article in English | MEDLINE | ID: mdl-22921100

ABSTRACT

Beat detection is a basic and fundamental step in electrocardiogram (ECG) processing. In many ECG applications strong artifacts from biological or technical sources could appear and cause distortion of ECG signals. Beat detection algorithm desired property is to avoid these distortions and detect beats in any situation. Our developed method is an extension of Christov's beat detection algorithm, which detects beat using combined adaptive threshold on transformed ECG signal (complex lead). Our offline extension adds estimation of independent components of measured signal into the transformation of ECG creating a signal called complex component, which enhances ECG activity and enables beat detection in presence of strong noises. This makes the beat detection algorithm much more robust in cases of unpredictable noise appearances, typical for holter ECGs and telemedicine applications of ECG. We compared our algorithm with the performance of our implementation of the Christov's and Hamilton's beat detection algorithm.


Subject(s)
Electrocardiography/methods , Heart/physiology , Signal Processing, Computer-Assisted , Algorithms , Databases, Factual , Statistics as Topic
SELECTION OF CITATIONS
SEARCH DETAIL
...