Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
1.
Br J Radiol ; 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38588565

ABSTRACT

PURPOSE: To conduct a meta-analysis to assess the efficacy of intravascular ultrasound (IVUS) during transjugular intrahepatic portosystemic shunt (TIPS) creation. METHODS: MEDLINE and Embase databases were queried until July 2022 for comparative studies reporting procedure metrics for TIPS creation with or without IVUS guidance. Meta-analysis was performed with random-effects modeling for total procedural time, time to portal venous access, fluoroscopy time, iodinated contrast volume use, air kerma, dose area product, and number of needle passes. Intraoperative procedure-related complications were also reviewed. RESULTS: Of 95 unique records initially identified, 6 were eligible for inclusion. A total of 194 and 240 patients underwent TIPS with and without IVUS guidance. Pooled analyses indicated that IVUS guidance was associated with reduced total procedure time (SMD -0.76 [95% CI -1.02, -0.50] P < 0.001), time to portal venous access (SMD -0.41 [95% CI -0.67, -0.15] P = 0.002), fluoroscopy time (SMD, -0.54 [95% CI -1.02, -0.07]; P = 0.002), contrast volume use (SMD, -0.89 [95% CI -1.16, -0.63]; P < 0.001), air kerma (SMD, -0.75 [95% CI -1.11, -0.38]; P < 0.001) and dose area product (SMD, -0.98 [95% CI -1.77, -0.20]; P = 0.013). 4.2 and 7.8 needle passes were required in the IVUS and non-IVUS group, respectively (SMD, -0.60 [95% CI -1.42, 0.21]; P = 0.134), whereas pooled complication rates were 15.2% (12/79), and 21.4% (28/131), respectively. CONCLUSION: IVUS guidance during TIPS creation improves procedural metrics including procedural time, contrast usage, and radiation exposure.

2.
Clin Spine Surg ; 2024 Mar 12.
Article in English | MEDLINE | ID: mdl-38490967

ABSTRACT

STUDY DESIGN: Retrospective study. OBJECTIVE: (1) To compare cervical magnetic resonance imaging (MRI) radiology reports to a validated grading system for cervical foraminal stenosis (FS) and (2) to evaluate whether the severity of cervical neural FS on MRI correlates to motor weakness or patient-reported outcomes. BACKGROUND: Radiology reports of cervical spine MRI are often reviewed to assess the degree of neural FS. However, research looking at the association between these reports and objective MRI findings, as well as clinical symptoms, is lacking. PATIENTS AND METHODS: We retrospectively identified all adult patients undergoing primary 1 or 2-level anterior cervical discectomy and fusion at a single academic center for an indication of cervical radiculopathy. Preoperative MRI was assessed for neural FS severity using the grading system described by Kim and colleagues for each level of fusion, as well as adjacent levels. Neural FS severity was recorded from diagnostic radiologist MRI reports. Motor weakness was defined as an examination grade <4/5 on the final preoperative encounter. Regression analysis was conducted to evaluate whether the degree of FS by either classification was related to patient-reported outcome measure severity. RESULTS: A total of 283 patients were included in the study, and 998 total levels were assessed. There were significant differences between the MRI grading system and the assessment by radio-logists (P< 0.001). In levels with moderate stenosis, 28.9% were classified as having no stenosis by radiology. In levels with severe stenosis, 29.7% were classified as having mild-moderate stenosis or less. Motor weakness was found similarly often in levels of moderate or severe stenosis (6.9% and 9.2%, respectively). On regression analysis, no associations were found between baseline patient-reported outcome measures and stenosis severity assessed by radiologists or MRI grading systems. CONCLUSION: Radiology reports on the severity of cervical neural FS are not consistent with a validated MRI grading system. These radiology reports underestimated the severity of neural foraminal compression and may be inappropriate when used for clinical decision-making. LEVEL OF EVIDENCE: Level III.

3.
Br J Radiol ; 97(1154): 353-362, 2024 Feb 02.
Article in English | MEDLINE | ID: mdl-38308040

ABSTRACT

OBJECTIVE: To compare treatment volumes reconstructed from hybrid Angio-CT catheter-directed infusion imaging and Couinaud anatomic model as well as the implied differences in Y-90 radiation dosimetry. METHODS: Patients who underwent transarterial radioembolization (TARE) using Y-90 glass microspheres with pretreatment CT or MRI imaging as well as intraprocedural angiography-CT (Angio-CT) were analysed. Treatment volumes were delineated using both tumoural angiosomes (derived from Angio-CT) and Couinaud anatomic landmarks. Segmental and lobar treatment volumes were calculated via semi-automated contouring software. Volume and dose differences were compared by the two-tailed Student t test or Wilcoxon signed-rank test. Factors affecting volume and dose differences were assessed via simple and/or multiple variable linear regression analysis. RESULTS: From September 2018 to March 2021, 44 patients underwent 45 lobar treatments and 38 patients received 56 segmental treatments. All target liver lobes and all tumours were completely included within the field-of-view by Angio-CT. Tumour sizes ranged between 1.1 and 19.5 cm in diameter. Segmental volumes and treatment doses were significantly different between the Couinaud and Angio-CT volumetry methods (316 vs 404 mL, P < .0001 and 253 vs 212 Gy, P < .01, respectively). Watershed tumours were significantly correlated with underestimated volumes by the Couinaud anatomic model (P < .001). There was a significant linear relationship between tumour diameter and percent volume difference (R2 = 0.44, P < .0001). The Couinaud model overestimated volumes for large tumours that exhibited central hypovascularity/necrosis and for superselected peripheral tumours. CONCLUSIONS: Angio-CT may confer advantages over the Couinaud anatomic model and enable more accurate, personalized dosimetry for TARE. ADVANCES IN KNOWLEDGE: Angio-CT may confer advantages over traditional cross-sectional and cone-beam CT imaging for selective internal radiation therapy planning.


Subject(s)
Carcinoma, Hepatocellular , Embolization, Therapeutic , Liver Neoplasms , Humans , Carcinoma, Hepatocellular/radiotherapy , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/radiotherapy , Yttrium Radioisotopes/therapeutic use , Cross-Sectional Studies , Retrospective Studies , Cone-Beam Computed Tomography/methods , Angiography , Radiometry/methods , Embolization, Therapeutic/methods , Microspheres
4.
J Shoulder Elbow Surg ; 33(6S): S122-S129, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38417731

ABSTRACT

BACKGROUND: Despite 2-stage revision being a common treatment for elbow prosthetic joint infection (PJI), failure rates are high. The purpose of this study was to report on a single institution's experience with 2-stage revisions for elbow PJI and determine risk factors for failed eradication of infection. The secondary purpose was to determine risk factors for needing allograft bone at the second stage of revision in the setting of compromised bone stock. METHODS: We retrospectively analyzed all 2-stage revision total elbow arthroplasties (TEAs) performed for infection at a single institution between 2006 and 2020. Data collected included demographics and treatment course prior to, during, and after 2-stage revision. Radiographs obtained after explantation and operative reports were reviewed to evaluate for partial component retention and incomplete cement removal. The primary outcome was failed eradication of infection, defined as the need for repeat surgery to treat infection after the second-stage revision. The secondary outcome was the use of allograft for compromised bone stock during the second-stage revision. Risk factors for both outcomes were determined. RESULTS: Nineteen patients were included. Seven patients (37%) had either the humeral or ulnar component retained during the first stage, and 10 (53%) had incomplete removal of cement in either the humerus or ulna. Nine patients (47%) had allograft strut used during reimplantation and reconstruction. Nine patients (47%) failed to eradicate the infection after 2-stage revision. Demographic data were similar between the repeat-infection and nonrepeat-infection groups. Six patients (60%) with retained cement failed compared with 3 patients (33%) with full cement removal (P = .370). Two patients (29%) with a retained component failed compared to 7 patients (58%) with full component removal (P = .350). Allograft was used less frequently when a well-fixed component or cement was retained, with no patients with a retained component needing allograft compared to 9 with complete component removal (P = .003). Three patients (30%) with retained cement needed allograft, compared with 6 patients (67%) who had complete cement removal (P = .179). CONCLUSION: Nearly half of the patients failed to eradicate infection after 2-stage revision. The data did not demonstrate a clear association between retained cement or implants and risk of recurrent infection. Allograft was used less frequently when a component and cement were retained, possibly serving as a proxy for decreased bone loss during the first stage of revision. Therefore, the unclear benefit of removing well-fixed components and cement need to be carefully considered as it likely leads to compromised bone stock that complicates the second stage of revision.


Subject(s)
Arthroplasty, Replacement, Elbow , Prosthesis-Related Infections , Reoperation , Humans , Reoperation/methods , Male , Female , Retrospective Studies , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/etiology , Arthroplasty, Replacement, Elbow/methods , Arthroplasty, Replacement, Elbow/adverse effects , Aged , Middle Aged , Treatment Failure , Risk Factors , Elbow Joint/surgery , Elbow Prosthesis , Bone Transplantation/methods , Aged, 80 and over
5.
Behav Sci (Basel) ; 14(2)2024 Jan 27.
Article in English | MEDLINE | ID: mdl-38392446

ABSTRACT

This study evaluated the implementation of the school-based Prevent-Teach-Reinforce (PTR) model for elementary school students who engage in high levels of challenging behavior. Three students (one with speech or language impairment and two without disabilities) and their classroom teachers in two public schools participated in the team-based PTR process, which involved teaming and goal setting, functional behavior assessment, intervention, and evaluation. A multiple-baseline-across-participants design was used to evaluate the impact of PTR on student behaviors. Direct and indirect observations of student behaviors were conducted across target and generalization academic time periods. The findings indicated that the PTR intervention effectively improved the classroom behaviors of all three participating students in both target and generalization academic time periods, decreasing disruptive behavior and increasing on-task behavior. Social validity assessments with the participating teachers and one student indicated high levels of acceptability of and satisfaction with the PTR intervention goals, procedures, and outcomes.

6.
Hand (N Y) ; : 15589447231222565, 2024 Jan 18.
Article in English | MEDLINE | ID: mdl-38235698

ABSTRACT

BACKGROUND: The purpose of this study was to compare the cyclic and load to failure characteristics of post-trapeziectomy suspensionplasty with the FiberLock Suspension System (FLSS; Arthrex Inc., Naples, Florida) to flexor carpi radialis ligament reconstruction (FCRLR). We hypothesized that the FLSS will have increased stiffness, yield, and ultimate load compared with FCRLR. METHODS: Ten matched pairs of cadaveric hands were used. One side of each pair was randomly assigned to receive the FCRLR or FLSS and the contralateral side received the other suspensionplasty. A complete trapeziectomy was performed followed by FLSS or FCRLR. Cyclic and load to failure characteristics were measured with loading in the distal to proximal direction. A preload of 1 N with 30 cycles of 1 N to 10 N was applied, followed by load to failure. A paired t test was used for statistical analysis (P < .05). RESULTS: The FLSS had significantly decreased nonrecoverable deformation and deformation at peak load during cyclic loading (P < .04). The FLSS also had significantly increased stiffness, yield load, ultimate load, and load and energy absorbed at 10 mm displacement compared with FCRLR (P < .04). All 10 FCRLR specimens failed with suture tearing through the tendon. Nine FLSS specimens failed due to suture slipping from the SwiveLock anchor (Arthrex Inc., Naples, Florida) and 1 failed due to the FiberTak anchor (Arthrex Inc., Naples, Florida) pulling through the index metacarpal. CONCLUSION: Suspensionplasty with the FLSS demonstrated greater structural integrity compared with FCRLR following trapeziectomy. The FLSS procedure may result in decreased thumb subsidence and decreased construct failure.

7.
Clin Imaging ; 106: 110065, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38113549

ABSTRACT

PURPOSE: To examine radiologist experiences and perceptions during a transition from score-based peer review to a peer learning program, and to assess differences in time-cost efficiency between the two models of quality improvement. METHODS: Differences in Likert scale survey responses from radiologists (N = 27) in a multispecialty group at a single tertiary academic center before and following intervention were evaluated by Mann-Whitney U test. Multiple variable linear regression analysis assessed independent variables and program preference. RESULTS: All positive impacts rated significantly higher for the peer learning program. Workflow disruption for the peer learning program rated significantly lower. 70.4 % (19 of 27) preferred the new program, and 25.9 % (7 of 27) preferred the old program. Only the "worth investment" questionnaire score demonstrated a significant correlation to program preference and with an effect that was greatest among all variables (Beta = 1.11, p = 0.02). There was a significantly decreased amount of time per month used to complete peer learning exercises (0.76 ± 0.45 h, N = 27) versus peer review exercises (1.71 ± 1.84 h, N = 34, p = 0.011). The result was a difference of 0.95 ± 1.89 h/month (11.4 ± 22.7 h/year), translating to an estimated direct salary time-cost saving of $1653.68/year/radiologists and a direct productivity time-cost saving of $3469.39/year/radiologist when utilizing the peer learning program. CONCLUSIONS: There was a strongly positive perception of the new peer learning program. There was a substantial implied direct time-cost saving from the transition to the peer learning program. PRECIS: The peer learning model emphasizes learning from errors via feedback in a non-punitive environment. This model was positively perceived and demonstrated substantial implied direct time-cost saving.


Subject(s)
Peer Review , Radiologists , Humans , Clinical Competence , Surveys and Questionnaires , Peer Group
8.
Clin Orthop Surg ; 15(4): 616-626, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37529193

ABSTRACT

Background: Disruption of the rotator cuff muscles compromises concavity compression force, which leads to superior migration of the humeral head and loss of stability. A novel idea of using the magnetic force to achieve shoulder stabilization in massive rotator cuff tears (MRCTs) was considered because the magnets can stabilize two separate entities with an attraction force. This study aimed to investigate the biomechanical effect of the magnetic force on shoulder stabilization in MRCTs. Methods: Seven fresh frozen cadaveric specimens were used with a customized shoulder testing system. Three testing conditions were set up: condition 1, intact rotator cuff without magnets; condition 2, an MRCT without magnets; condition 3, an MRCT with magnets. For each condition, anterior-posterior translation, superior translation, superior migration, and subacromial contact pressure were measured at 0°, 30°, and 60° of abduction. The abduction capability of condition 2 was compared with that of condition 3. Results: The anterior-posterior and superior translations increased in condition 2; however, they decreased compared to condition 2 when the magnets were applied (condition 3) in multiple test positions and loadings (p < 0.05). Abduction capability improved significantly in condition 3 compared with that in condition 2, even for less deltoid loading (p < 0.05). Conclusions: The magnet biomechanically played a positive role in stabilizing the shoulder joint and enabled abduction with less deltoid force in MRCTs. However, to ensure that the magnet is clinically applicable as a stabilizer for the shoulder joint, it is necessary to thoroughly verify its safety in the human body and to conduct further research on technical challenges.


Subject(s)
Rotator Cuff Injuries , Shoulder Joint , Humans , Rotator Cuff Injuries/diagnostic imaging , Shoulder Joint/diagnostic imaging , Shoulder Joint/physiology , Magnets , Biomechanical Phenomena , Cadaver , Range of Motion, Articular/physiology
9.
J Vasc Interv Radiol ; 34(11): 1970-1976.e1, 2023 11.
Article in English | MEDLINE | ID: mdl-37532096

ABSTRACT

Radiation segmentectomy with a dose of >190 Gy using yttrium-90 (90Y) glass microspheres for intrahepatic cholangiocarcinoma (iCCA) has been shown to be safe and effective. The present study further increased the dose to >400 Gy for treatment of iCCA as complete pathologic necrosis has been shown in hepatocellular carcinoma using this ablative approach. A total of 10 patients with 13 tumors (median size, 5.3 cm; range, 1.5-13.6 cm) at a single institution underwent >400-Gy segmental radioembolization. Objective response was achieved in all tumors (13 of 13, 100%). One patient developed a Grade 3 or greater major adverse event (stroke and hepatic decompensation). One patient was bridged to transplant (>95% pathologic necrosis), whereas another underwent resection (>99% necrosis). Contralateral hypertrophy was observed in 6 out of 6 patients treated with modified lobectomy dosing, with a functional liver reserve increase from a median of 31.5% to 57.1%. The present report suggests that segmental transarterial radioembolization with >400 Gy is feasible in terms of safety and effectiveness for treating iCCA.


Subject(s)
Bile Duct Neoplasms , Carcinoma, Hepatocellular , Cholangiocarcinoma , Embolization, Therapeutic , Liver Neoplasms , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/radiotherapy , Liver Neoplasms/drug therapy , Microspheres , Carcinoma, Hepatocellular/pathology , Yttrium Radioisotopes/adverse effects , Embolization, Therapeutic/adverse effects , Cholangiocarcinoma/diagnostic imaging , Cholangiocarcinoma/radiotherapy , Necrosis/chemically induced , Necrosis/drug therapy , Bile Ducts, Intrahepatic , Bile Duct Neoplasms/diagnostic imaging , Bile Duct Neoplasms/radiotherapy , Treatment Outcome , Retrospective Studies
10.
JSES Int ; 7(4): 685-691, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37426934

ABSTRACT

Background: The purpose of this study was to quantify the biomechanical characteristics of a new looping stitch, developed with the concepts of a looping, locking stitch that decreases needle penetrations of the tendon, and compare it to a classic Krackow stitch for distal biceps suture-tendon fixation. Methods: The Krackow stitch with No. 2 braided suture and the looping stitch with a No. 2 braided suture loop attached to a 25-mm-length by 1.3-mm-width polyblend suture tape were compared. The Looping stitch was performed with single strand locking loops and wrapping suture around the tendon, resulting in half the needle penetrations through the graft compared to the Krackow stitch. Ten matched pairs of human distal biceps tendons were used. One side of each pair was randomly assigned to either the Krackow or the looping stitch, and the contralateral side was used for the other stitch. For biomechanical testing, each construct was preloaded to 5 N for 60 seconds, followed by cyclic loading to 20 N, 40 N, and 60 N for 10 cycles each, and then loaded to failure. The deformation of the suture-tendon construct, stiffness, yield load, and ultimate load were quantified. Comparisons between the Krackow and looping stitches were performed with a paired t-test using P < .05 as statistically significant. Results: The Krackow stitch and looping stitch had no significant difference in stiffness, peak deformation, or nonrecoverable deformation after 10 cycles of loading to 20 N, 40 N, and 60 N. There was no difference between the Krackow stitch and looping stitch in load applied to displacement of 1 mm, 2 mm, and 3 mm. The ultimate load showed that the looping stitch was significantly stronger compared to the Krackow stitch (Krackow stitch: 223.7 ± 50.3 N; looping stitch: 312.7 ± 53.8 N) (P = .002). The failure modes were either suture breakage or tendon cut through. For the Krakow stitch, there was 1 suture breakage and 9 tendons cut through. For the looping stitch, there were five suture breakages, and five tendons cut through. Conclusions: With fewer needle penetrations, incorporation of 100% of the tendon diameter, and a higher ultimate load to failure compared to the Krackow stitch, the Looping stitch may be a viable option to reduce deformation, failure, and cut-out of the suture-tendon construct.

11.
J Shoulder Elbow Surg ; 32(11): 2382-2388, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37379965

ABSTRACT

BACKGROUND: The biomechanical changes and treatment guidelines on acromial fracture after reverse shoulder arthroplasty (RSA) are still not well understood. The purpose of our study was to analyze the biomechanical changes with respect to acromial fracture angulation in RSA. METHODS: RSA was performed on 9 fresh-frozen cadaveric shoulders. An acromial osteotomy was performed on the plane extending from the glenoid surface to simulate an acromion fracture. Four conditions of acromial fracture inferior angulation were evaluated (0°, 10°, 20°, and 30° angulation). The middle deltoid muscle loading origin position was adjusted based on the position of each acromial fracture. The impingement-free angle and capability of the deltoid to produce movement in the abduction and forward flexion planes were measured. The length of the anterior, middle, and posterior deltoid was also analyzed for each acromial fracture angulation. RESULTS: There was no significant difference in the abduction impingement angle between 0° (61.8° ± 2.9°) and 10° angulation (55.9° ± 2.8°); however, the abduction impingement angle of 20° (49.3° ± 2.9°) significantly decreased from 0° and 30° angulation (44.2° ± 4.6°), and 30° angulation significantly differed from 0° and 10° (P < .01). On forward flexion, 10° (75.6° ± 2.7°), 20° (67.9° ± 3.2°), and 30° angulation (59.8° ± 4.0°) had a significantly decreased impingement-free angle than 0° (84.2° ± 4.3°; P < .01), and 30° angulation had a significantly decreased impingement-free angle than 10°. On analysis of glenohumeral abduction capability, 0° significantly differed (at 12.5, 15.0, 17.5, and 20.0N) from 20° and 30°. For forward flexion capability, 30° angulation showed a significantly smaller value than 0° (15N vs. 20N). As acromial fracture angulation increased, the middle and posterior deltoid muscles of 10°, 20°, and 30° became shorter than those of 0°; however, no significant change was found in the anterior deltoid length. CONCLUSIONS: In acromial fractures at the plane of glenoid surface, 10° inferior angulation of the acromion did not interfere with abduction and abduction capability. However, 20° and 30° of inferior angulation caused prominent impingement in abduction and forward flexion and reduced abduction capability. In addition, there was a significant difference between 20° and 30°, suggesting that not only the location of the acromion fracture after RSA but also the degree of angulation are important factors for shoulder biomechanics.

12.
J Shoulder Elbow Surg ; 32(8): 1662-1672, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37044302

ABSTRACT

BACKGROUND: The objective of our study was to quantify the biomechanical effectiveness of lateralization in RTSA with respect to glenoid and humeral component configurations. METHODS: Eight cadaveric shoulders were tested in a custom shoulder testing system. Three parameters, including the glenosphere thickness, humeral tray offset, and insert thickness, were assessed by implanting 8 configurations on each specimen. Humeral position, maximum internal rotation, and maximum external rotation (ER) before impingement were quantified at 0° and 30° glenohumeral abduction. The adduction angle at which the humeral component contacted the inferior scapular neck and the abduction angle where acromial notching occurred were also measured. The simulated active range of motion, including ER and abduction capability, was tested by increasing the load applied to the remaining posterior cuff and middle deltoid, respectively. Stability was evaluated by the forces that induced anterior dislocation at 30° abduction. RESULTS: The thicker glenosphere affected only lateralization, whereas the centric humeral tray and thicker insert significantly affected humeral lateralization and distalization simultaneously. Greater adduction and ER angles were found in more lateralized humerus. A significant positive correlation between humeral lateralization and ER capability was observed; however, lateralization did not significantly improve implant stability in this cadaveric testing system. CONCLUSION: Lateralization is achievable at both the glenoid and humeral sides but has different effects; therefore, lateralized implant options should be selected according to patients' needs. Lateralization is an effective strategy for reducing adduction notching while increasing ER capability. Thicker glenospheres only affected humeral lateralization. The centric humeral tray would be selected for less distalization to avoid overlengthening, whereas an eccentric humeral tray is the most effective for distalization and medialization in reducing abduction notching to the acromion and for patients with pseudoparalysis.


Subject(s)
Arthroplasty, Replacement, Shoulder , Shoulder Joint , Humans , Arthroplasty, Replacement, Shoulder/methods , Shoulder Joint/surgery , Prosthesis Design , Range of Motion, Articular , Cadaver , Humerus/surgery , Biomechanical Phenomena
13.
J Shoulder Elbow Surg ; 32(6): 1285-1294, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36803947

ABSTRACT

BACKGROUND: The objective of this study was to quantify the valgus laxity and strain of the elbow ulnar collateral ligament (UCL) complex after repeated valgus stretching and subsequent recovery. Understanding these changes may have important implications in improving strategies for injury prevention and treatment. The hypothesis was that the UCL complex will demonstrate a permanent increase in valgus laxity and region-specific increase in strain as well as region-specific recovery characteristics. METHODS: Ten cadaveric elbows (7M, 3F, 61.7 ± 2.7 years) were used. Valgus angle and strain of the anterior and posterior bands of the anterior bundle and the posterior bundle were measured at 1 Nm, 2.5 Nm, 5 Nm, 7.5 Nm, and 10 Nm of valgus torque at 70° of flexion for: (1) intact UCL, (2) stretched UCL, and (3) rested UCL. To stretch the UCL, elbows were cycled with increasing valgus torque at 70° of flexion (10 Nm-20 Nm in 1 Nm increments) until the valgus angle increased 8° from the intact valgus angle measured at 1Nm. This position was held for 30 minutes. Specimens were then unloaded and rested for 2 hours. Linear mixed effects model with Tukey's post hoc test was used for statistical analysis. RESULTS: Stretching significantly increased valgus angle compared to the intact condition 3.2° ± 0.2° (P < .001). Strains of both the anterior and posterior bands of the anterior bundle were significantly increased from intact by 2.8% ± 0.9% (P = .015) and 3.1% ± 0.9% (P = .018), respectively at 10 Nm. Strain in the distal segment of the anterior band was significantly higher than the proximal segment with loads of 5 Nm and higher (P < .030). After resting, the valgus angle significantly decreased from the stretched condition by 1.0° ± 0.1° (P < .001) but failed to recover to intact levels (P < .004). After resting, the posterior band had a significantly increased strain compared to the intact state of 2.6% ± 1.4% (P = .049) while the anterior band was not significantly different from intact. CONCLUSION: After repeated valgus loading and subsequent resting, the UCL complex demonstrated permanent stretching with some recovery but not to intact levels. The anterior band demonstrated increased strain in the distal segment compared to the proximal segment with valgus loading. The anterior band was able to recover to strain levels similar to intact after resting, while the posterior band did not.


Subject(s)
Collateral Ligament, Ulnar , Collateral Ligaments , Elbow Joint , Humans , Elbow , Collateral Ligament, Ulnar/injuries , Cadaver , Biomechanical Phenomena , Collateral Ligaments/injuries
14.
Arch Orthop Trauma Surg ; 143(8): 4731-4739, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36658364

ABSTRACT

INTRODUCTION: Latissimus dorsi and teres major (LDTM) tendon transfer has demonstrated better clinical outcomes compared to Latissimus dorsi (LD) transfer for irreparable anterosuperior cuff (subscapularis/supraspinatus) tears; however, the biomechanical effects of these procedures are unknown. Therefore, the objective of this study was to compare kinematics and internal rotation of LDTM transfer to LD transfer for anterosuperior cuff tear. METHODS: Eight cadaveric shoulders were tested in four conditions; (1) intact, (2) anterosuperior rotator cuff tear, (3) LDTM transfer, and (4) LD transfer. Glenohumeral kinematics and internal rotation at 0°, 30°, and 60° of glenohumeral abduction in the scapular plane were measured. Muscle loading was applied based on physiological cross-sectional area ratios with three muscle loading conditions to simulate potentially increased tension due to the advanced insertion site of the transferred tendons. RESULTS: The anterosuperior rotator cuff tear leads to a significant superior shift of the humeral head compared to intact at 0° and 30° abduction (p < 0.039). Both the LDTM (p < 0.047) and LD transfers (p < 0.032) significantly shifted the humeral head inferiorly compared to the tear condition.; however, the LDTM transfer shifted the head in the anteroinferior direction compared to the LD transfer at 60° abduction and 30° ER (p < 0.045). Both LDTM and LD transfer significantly increased internal resting rotation (p < 0.008) and maximum internal rotation (p < 0.008) compared to anterosuperior rotator cuff tear and intact at 30° and 60° abduction. LDTM transfer resulted in a significant internal resting rotation compared with the LD transfer at 30° abduction with double muscle loading (p = 0.02). At 0° abduction, the LDTM transfer (p < 0.027) significantly increased maximum internal rotation compared to anterosuperior rotator cuff tear and intact. CONCLUSION: Although both LDTM and LD tendon transfer improved the abnormal humeral head apex position and internal rotation compared with the tear condition, the LDTM transfer was biomechanically superior to the LD transfer in a cadaveric model.


Subject(s)
Rotator Cuff Injuries , Shoulder Joint , Superficial Back Muscles , Humans , Rotator Cuff Injuries/surgery , Tendon Transfer/methods , Biomechanical Phenomena , Rotator Cuff/surgery , Range of Motion, Articular/physiology , Cadaver
15.
J Shoulder Elbow Surg ; 32(4): 703-712, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36529382

ABSTRACT

BACKGROUND: Irreparable anterosuperior rotator cuff tears (IASRCTs) can result in a gradual loss of active elevation and internal rotation, superior and anterior translation of the humeral head, and cuff tear arthropathy. Joint-preserving treatment options for IASRCTs in young and high-demand elderly patients remain a subject of ongoing debate. The aim of the study was to evaluate the biomechanical efficacy of the combined latissimus dorsi and teres major tendon (LDTM) transfer and compare it to an isolated latissimus dorsi (LD) transfer in a cadaveric IASRCT model. METHODS: Eight cadaveric shoulders (mean age, 68.3 ± 5.2 years; range 58-71) were tested with a custom shoulder testing system. All specimens were tested at 0°, 30°, and 60° of glenohumeral abduction in the scapular plane under 4 conditions: (1) intact, (2) IASRCT, (3) combined LDTM transfer, and (4) isolated LD transfer. The superior and anteroinferior translation and subacromial contact pressure were measured. The effects of 3 different LD and LDTM muscle loading conditions were investigated to determine the effectiveness of the muscle transfer conditions. A linear mixed effect model was used for statistical analysis, followed by a Tukey post hoc test. RESULTS: IASRCTs significantly increased superior translation, anteroinferior translation, and subacromial peak contact pressure. Combined LDTM transfer significantly decreased superior and anteroinferior translation compared with IASRCTs in all positions and muscle loadings. Isolated LD transfer did not significantly decrease superior (P > .115) and anteroinferior translation (P > .151) compared to IASRCT at any abduction and muscle loads except superior translation at 60° abduction and 90° of external rotation (ER) (P < .036). LDTM transfer also significantly decreased peak contact pressure from the IASRCT condition at every abduction angle (P < .046). However, isolated LD transfer significantly decreased subacromial peak contact pressure only at 30° abduction and 0° and 30° of ER with triple loading (P < .048), as well as at 60° abduction and 90° of ER (P < .003). CONCLUSIONS: Combined LDTM transfer decreased superior translation, anteroinferior translation, and subacromial contact pressure compared with the IASRCT condition. Isolated LD transfer did not improve glenohumeral translation and subacromial contact pressure. Combined LDTM transfer may be a more reliable treatment option than isolated LD transfer in patients with an IASRCT.


Subject(s)
Rotator Cuff Injuries , Shoulder Joint , Superficial Back Muscles , Humans , Aged , Middle Aged , Shoulder , Rotator Cuff Injuries/surgery , Rotator Cuff/surgery , Tendon Transfer , Shoulder Joint/surgery , Tendons , Cadaver , Biomechanical Phenomena , Range of Motion, Articular/physiology
16.
Cardiovasc Intervent Radiol ; 46(6): 726-736, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36478028

ABSTRACT

PURPOSE: To investigate risk factors associated with post-microwave ablation (MWA) abscess development. MATERIALS AND METHODS: A retrospective case-control analysis was conducted to identify hepatic MWA performed at a single tertiary medical center between January 2010 and January 2022. Case and control patients were defined as those who did or did not develop intrahepatic abscess within 3 months following MWA, respectively. Correlations between risk factors and post-MWA abscess development were assessed by Fisher's exact test. RESULTS: Between 2010 and 2022, 253 patients underwent 376 MWA sessions with post-ablation abscess complication rate of 1.1% (4/376). Complications associated with intrahepatic abscess included bacteremia, empyema, pleural abscess, subcutaneous abscess, cholangitis, bile leak, biliocutaneous and arterio-biliary fistulae, and pseudoaneurysm. One patient expired from septic shock 5 days post-ablation. All abscesses were treated by percutaneous drainage and antibiotics. One patient required concomitant placement of a biliary stent and embolization of a biliocutaneous tract. History of Sphincter of Oddi manipulation (p < 0.01), cholangiocarcinoma (p < 0.05), transarterial radioembolization (TARE) to the index lesion (p < 0.05), and abnormal serum alkaline phosphatase levels (p < 0.05) were significantly correlated with post-MWA abscess. The risk of developing post-MWA abscesses for patients with a history of cholangiocarcinoma or a history of Sphincter of Oddi manipulation were 20.0% and 27.2%, respectively. CONCLUSION: Patients with prior Sphincter of Oddi manipulation, cholangiocarcinoma, or TARE are at greater risk of developing post-MWA abscess.


Subject(s)
Bile Duct Neoplasms , Catheter Ablation , Cholangiocarcinoma , Liver Abscess , Liver Neoplasms , Humans , Microwaves , Retrospective Studies , Catheter Ablation/adverse effects , Liver Neoplasms/surgery , Liver Neoplasms/complications , Liver Abscess/etiology , Risk Factors , Cholangiocarcinoma/surgery , Bile Ducts, Intrahepatic/surgery , Bile Duct Neoplasms/surgery
17.
Semin Intervent Radiol ; 39(5): 508-514, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36561937

ABSTRACT

Traumatic injury to the large, central venous vasculature, although rare, is associated with high morbidity and mortality rates. Conventional open surgical treatment by repair or ligation can be technically challenging in anatomically difficult areas to expose. Furthermore, open surgical approach can release tension on the venous injury and result in uncontrollable bleeding. Endovascular techniques such as stenting and embolization can be used effectively for the treatment of traumatic venous injury. This article will discuss the morbidity and mortality associated with traumatic venous injuries, venous anatomy, endovascular treatment options, and management of traumatic venous injury.

18.
Abdom Radiol (NY) ; 47(8): 2704-2711, 2022 08.
Article in English | MEDLINE | ID: mdl-35723717

ABSTRACT

PURPOSE: To investigate the utilization of an angiography-CT (Angio-CT) system and its advantages for single patient encounters. METHODS: Interventions utilizing both CT and fluoroscopy to perform multiple procedures in a single encounter or single interventions using both were identified. Cases were stratified by complexity (defined by RVUs). Comparative analyses of room (TRoom) and total encounter (TEncounter) times were performed between non-complex bundled cases and controls. RESULTS: Between June 2018 and August 2019, 1108 procedures were performed via the Angio-CT system; 10% (114/1108) used both fluoroscopy and CT. 21% (24/114) Involved more than one procedure in a single encounter that required a CT-only and fluoroscopy-only bundled procedure. 59% (67/114) were non-complex, and 70% (80/114) were non-oncologic. 82.5% (14/17) of non-complex bundled procedures demonstrated TRoom below the mean of their respective controls; 52.8% (9/17) were 2 standard deviations below the control means. Pleural catheter placement following post-lung biopsy pneumothorax was the most common non-complex bundled case with a significant reduction in TRoom when performed via Angio-CT compared to control (99 vs. 163 min, p < 0.0001). There was a significant reduction in TEncounter for abdominopelvic drain placement procedures bundled with either (1) percutaneous nephrostomy tube evaluation with or without replacement, or (2) central venous catheter placement (211 min vs. 344 min, p < 0.001 and 231 min vs. 347 min, p < 0.05, respectively). CONCLUSION: The primary use for the hybrid Angio-CT system was to perform non-oncologic and non-complex cases with potential reduction in TRoom and TEncounter for specific non-complex bundled cases.


Subject(s)
Radiology, Interventional , Tomography, X-Ray Computed , Angiography , Computed Tomography Angiography , Fluoroscopy/methods , Humans , Radiography, Interventional/methods , Tomography, X-Ray Computed/methods
19.
J Am Acad Orthop Surg ; 30(13): 629-635, 2022 07 01.
Article in English | MEDLINE | ID: mdl-35442912

ABSTRACT

OBJECTIVES: This biomechanical study seeks to define the relative effectiveness of contemporary single and dual implant constructs for fixation of an extra-articular proximal tibia fracture model. METHODS: An extra-articular proximal tibia fracture model was created using synthetic tibias. Four constructs were tested. Constructs included (1) lateral locked plate (LLP), (2) intramedullary nail (IMN), (3) combined LLP and IMN (PN), and (4) LLP and medial locked plate. Specimens were axially loaded through the medial plateau to evaluate construct stiffness and the ability to resist varus collapse. RESULTS: Dual implant constructs were stiffer than single implant constructs in this model. Although DP and PN were stiffer than IMN at all loads tested, the difference was notable only for DP at higher loads. Isolated LLP provided insufficient stability to be tested at higher loads. CONCLUSION: Dual plate fixation provides the greatest resistance to varus collapse. In the clinical setting, consideration must be given to the fracture morphology, desired construct stiffness, and soft-tissue envelope in selecting the optimal construct to be used.


Subject(s)
Fracture Fixation, Intramedullary , Tibial Fractures , Biomechanical Phenomena , Bone Plates , Fracture Fixation, Internal , Humans , Tibia/surgery , Tibial Fractures/surgery
20.
Int J Womens Dermatol ; 6(4): 268-271, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33015284

ABSTRACT

Hydroxychloroquine (HQ) and quinacrine are widely used antimalarials for systemic lupus erythematosus (SLE) and other autoimmune diseases. We report a case of antimalarial-induced hyperpigmentation in a 57-year old African-American woman. The patient had a long-standing history of SLE that was treated with HQ and quinacrine in varying doses for 16 years. The disease improved considerably and entered remission; however, the patient subsequently developed severe, disseminated hyperpigmentation on her face, trunk, upper and lower extremities. A malar facial biopsy revealed numerous perivascular and scattered interstitial, heavily pigment laden dark brown to black macrophages. The Fontana Masson staining was positive for melanin, and Perl's stain for iron was negative. This staining pattern, to our knowledge, has only been reported once before in the literature. Our patient represents a rare case of severe recalcitrant hyperpigmentation induced by combination HQ and quinacrine therapy for SLE.

SELECTION OF CITATIONS
SEARCH DETAIL
...