ABSTRACT
A comparison of 23 children with inflammatory bowel disease presenting with musculoskeletal symptoms and 46 children with arthritis of other causes yielded significantly higher rates in the inflammatory bowel disease group of sacroiliitis, arthralgia, additive and recurrent arthritis, microcytic anemia, elevated inflammatory markers, and hypoalbuminemia. Clinical awareness of these findings could expedite diagnosis and treatment.
Subject(s)
Inflammatory Bowel Diseases/complications , Musculoskeletal Diseases/etiology , Adolescent , Child , Female , Humans , Inflammatory Bowel Diseases/diagnosis , Male , Retrospective StudiesABSTRACT
Erythropoiesis-stimulating agents (ESAs) have been used in horses for doping purposes to increase the performance of these animals in endurance sports. Currently, enzyme-linked immunosorbent assay (ELISA) and mass spectrometry methods are used to detect ESA abuse in equines. However, the sarcosyl polyacrylamide gel-electrophoresis (SAR-PAGE) technique could also be used, since its application in human doping control is well established and has proven to be more sensitive. In this work, the SAR-PAGE method was used to detect recombinant human erythropoietin (rHuEPO), novel erythropoiesis stimulating protein (NESP), continuous erythropoietin receptor activator (CERA), and fusion protein of erythropoietin with human immunoglobulin heavy chain Fc region (EPO-Fc) in horse blood and urine. The purification technique for human blood using MAIIA kits worked well for horse samples. The major challenge was horse urine immunopurification, which proved difficult due to filter clogging, but heating and cooling of the horse urine followed by filtration in 30-kDa molecular weight cut-off filters solved this problem. The limits of detection (LODs) of 1.3, 1.6, 6.6, and 13.3 pg/mL for rHuEPO, NESP, CERA, and EPO-Fc, respectively, obtained in spiked urine and 40, 100, 80, and 400 pg/mL for rHuEPO, NESP, CERA, and EPO-Fc, respectively, acquired in spiked blood are lower than the LODs reported in the literature using liquid chromatography-mass spectrometry (LC-MS) methods. In addition, the presence of ESAs was detected up to 9 days after the administration of microdoses of Hemax (rHuEPO), NESP, and CERA in horse blood and urine. SAR-PAGE may be implemented in the routine analysis of horse doping control laboratories for screening and confirmation of ESA abuse, mainly due to its high sensitivity for both matrices compared to published mass spectrometric methods.
Subject(s)
Electrophoresis, Polyacrylamide Gel/methods , Erythropoietin/blood , Erythropoietin/urine , Horses/blood , Horses/urine , Animals , Detergents/chemistry , Doping in Sports , Male , Performance-Enhancing Substances/blood , Performance-Enhancing Substances/urine , Sarcosine/analogs & derivatives , Sarcosine/chemistry , Substance Abuse Detection/methodsABSTRACT
This paper summarises the results obtained from the doping control analyses performed during the Summer XXXI Olympic Games (August 3-21, 2016) and the XV Paralympic Games (September 7-18, 2016). The analyses of all doping control samples were performed at the Brazilian Doping Control Laboratory (LBCD), a World Anti-Doping Agency (WADA)-accredited laboratory located in Rio de Janeiro, Brazil. A new facility at Rio de Janeiro Federal University (UFRJ) was built and fully operated by over 700 professionals, including Brazilian and international scientists, administrative staff, and volunteers. For the Olympic Games, 4913 samples were analysed. In 29 specimens, the presence of a prohibited substance was confirmed, resulting in adverse analytical findings (AAFs). For the Paralympic Games, 1687 samples were analysed, 12 of which were reported as AAFs. For both events, 82.8% of the samples were urine, and 17.2% were blood samples. In total, more than 31 000 analytical procedures were conducted. New WADA technical documents were fully implemented; consequently, state-of-the-art analytical toxicology instrumentation and strategies were applied during the Games, including different types of mass spectrometry (MS) analysers, peptide, and protein detection strategies, endogenous steroid profile measurements, and blood analysis. This enormous investment yielded one of the largest Olympic legacies in Brazil and South America. Copyright © 2017 John Wiley & Sons, Ltd.