1.
Med Phys ; 51(6): 4044-4055, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38682574

ABSTRACT

BACKGROUND: High-resolution brain positron emission tomography (PET) scanner is emerging as a significant and transformative non-invasive neuroimaging tool to advance neuroscience research as well as improve diagnosis and treatment in neurology and psychiatry. Time-of-flight (TOF) and depth-of-interaction (DOI) information provide markedly higher PET imaging performance by increasing image signal-to-noise ratio and mitigating spatial resolution degradation due to parallax error, respectively. PET detector modules that utilize light sharing can inherently carry DOI information from the multiple timestamps that are generated per gamma event. The difference between two timestamps that are triggered by scintillation photons traveling in opposite directions signifies the event's depth-dependent optical photon TOF (oTOF). However, light leak at the crystal-readout interface substantially degrades the resolution of this oTOF-based depth encoding. PURPOSE: We demonstrate the feasibility of oTOF-based depth encoding by mitigating light leak in single-ended-readout Prism-PET detector modules using tapered crystals. Minimizing light leak also improved both energy-based DOI and coincidence timing resolutions. METHODS: The tapered Prism-PET module consists of a 16  × $\times$  16 array of 1.5  × $\times$  1.5  × $\times$  20  mm 3 ${\rm {mm}}^3$ lutetium yttrium oxyorthosillicate (LYSO) crystals, which are tapered down to 1.2  × $\times$  1.2  mm 2 ${\rm {mm}}^2$ at the crystal-readout interface. The LYSO array couples 4-to-1 to an 8  × $\times$  8 array of 3  × $\times$  3  mm 2 ${\rm {mm}}^2$ silicon photomultiplier (SiPM) pixels on the tapered end and to a segmented prismatoid light guide array on the opposite end. Performance of tapered and non-tapered Prism-PET detectors was experimentally characterized and evaluated by measuring flood histogram, energy resolution, energy-, and oTOF-based DOI resolutions, and coincidence timing resolution. Sensitivities of scanners using different Prism-PET detector designs were simulated using Geant4 application for tomographic emission (GATE). RESULTS: For the tapered (non-tapered) Prism-PET module, the measured full width at half maximum (FWHM) energy, timing, energy-based DOI, and oTOF-based DOI resolutions were 8.88 (11.18)%, 243 (286) ps, 2.35 (3.18) mm, and 5.42 (13.87) mm, respectively. The scanner sensitivities using non-tapered and tapered crystals, and 10 rings of detector modules, were simulated to be 30.9 and 29.5 kcps/MBq, respectively. CONCLUSIONS: The tapered Prism-PET module with minimized light leak enabled the first experimental report of oTOF-based depth encoding at the detector module level. It also enabled the utilization of thinner (i.e., 0.1 mm) inter-crystal spacing with barium sulfate as the reflector while also improving energy-based DOI and timing resolutions.


Subject(s)
Photons , Positron-Emission Tomography , Positron-Emission Tomography/instrumentation , Image Processing, Computer-Assisted/methods , Optical Phenomena
2.
J Appl Clin Med Phys ; 25(4): e14316, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38462952

ABSTRACT

CT protocol management is an arduous task that requires expertise from a variety of radiology professionals, including technologists, radiologists, radiology IT professionals, and medical physicists. Each CT vendor has unique, proprietary protocol file structures, some of which may vary by scanner model, making it difficult to develop a universal framework for distilling technical parameters to a human-readable file format. An ideal solution for CT protocol management is to minimize the work required for parameter extraction by introducing a data format into the workflow that is universal to all CT scanners. In this paper, we report a framework for CT protocol management that converts raw protocol files to an intermediary format before outputting them in a human-readable format for a variety of practical clinical applications, including routine protocol review, protocol version tracking, and cross-protocol comparisons. The framework was developed in Python 3. Technical parameters of interest were determined via collaborative effort between medical physicists and lead technologists. Protocol files were extracted and analyzed from a variety of scanners across our hospital-wide CT fleet, including various systems from Siemens and GE. Protocols were subcategorized based on relevant technical parameters into regular, dual-energy, and cardiac CT protocols. Backend code for technical parameter extraction from raw protocol files to a JavaScript Object Notation (JSON) format was performed on a per-system basis. Conversion from JSON to a readable output format (MS Excel) was performed identically for all scanners using the universal framework developed and presented in this work. Example results for Siemens and GE scanners are shown, including side-by-side comparisons for protocols with similar clinical indications. In conclusion, our CT protocol management framework may be deployed on any CT system to improve clinical efficiency in protocol review and upkeep.


Subject(s)
Radiology , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Tomography Scanners, X-Ray Computed
3.
Phys Med Biol ; 69(3)2024 Feb 02.
Article in English | MEDLINE | ID: mdl-38169459

ABSTRACT

Objective.Inter-crystal scattering (ICS) in light-sharing positron emission tomography (PET) detectors leads to ambiguity in positioning the initial interaction, which significantly degrades the contrast, quantitative accuracy, and spatial resolution of the resulting image. Here, we attempt to resolve the positioning ambiguity of ICS in a light-sharing depth-encoding detector by exploiting the confined, deterministic light-sharing enabled by the segmented light guide unique to Prism-PET.Approach.We first considered a test case of ICS between two adjacent crystals using an analytical and a neural network approach. The analytical approach used a Bayesian estimation framework constructed from a scatter absorption model-the prior-and a detector response model-the likelihood. A simple neural network was generated for the same scenario, to provide mutual validation for the findings. Finally, we generalized the solution to three-dimensional event positioning that handles all events in the photopeak using a convolutional neural network with unique architecture that separately predicts the identity and depth-of-interaction (DOI) of the crystal containing the first interaction.Main results.The analytical Bayesian method generated an estimation error of 20.5 keV in energy and 3.1 mm in DOI. Further analysis showed that the detector response model was sufficiently robust to achieve adequate performance via maximum likelihood estimation (MLE), without prior information. We then found convergent results using a simple neural network. In the generalized solution using a convolutional neural network, we found crystal identification accuracy of 83% and DOI estimation error of 3.0 mm across all events. Applying this positioning algorithm to simulated data, we demonstrated significant improvements in image quality over the baseline, centroid-based positioning approach, attaining 38.9% improvement in intrinsic spatial resolution and enhanced clarity in hot spots of diameters 0.8 to 2.5 mm.Significance.The accuracy of our findings exceeds those of previous reports in the literature. The Prism-PET light guide, mediating confined and deterministic light-sharing, plays a key role in ICS recovery, as its mathematical embodiment-the detector response model-was the essential driver of accuracy in our results.


Subject(s)
Positron-Emission Tomography , Tomography, X-Ray Computed , Bayes Theorem , Positron-Emission Tomography/methods , Photons , Algorithms
4.
Radiology ; 310(1): e232128, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38226878

ABSTRACT

Background Fluoroscopy is an imaging modality associated with a wide range of dose levels, characterized using a variety of dose metrics, including effective dose. However, for clinical procedures, effective dose is a seldom-used and unregulated metric in the United States, and thus, it is not extensively studied in radiology despite potentially large clinical implications for patients, especially children and infants. Purpose To formulate and report a dose catalog across all diagnostic and interventional radiology (IR) fluoroscopy examination or procedure types at a specialized tertiary care pediatric hospital. Materials and Methods In this retrospective study, dose metrics taken from radiation dose structured reports of fluoroscopy between October 2014 and March 2023 were analyzed. The reports included fluoroscopy across 18 diagnostic examination types and 24 IR procedure types. The National Cancer Institute dosimetry system for Radiography and Fluoroscopy Monte Carlo software was used to estimate age-specific effective dose from dose-area product (DAP). The DAP-to-effective dose conversion factors were estimated per IR procedure type and diagnostic fluoroscopy examination type based on age. Results A total of 11 536 individual diagnostic fluoroscopy examinations (18 types) and 8017 individual IR procedures (24 types) were analyzed. Median effective dose values per diagnostic fluoroscopy examination type ranged from 0.0010 to 0.44 mSv (mean, 0.0808 mSv ± 0.0998 [SD]). Calculated DAP-to-effective dose conversion factors ranged from 0.04 to 2.48 mSv/Gy · cm2 (mean, 0.758 mSv/Gy · cm2 ± 0.614) across all diagnostic fluoroscopy examination types. Median effective dose values per IR procedure type ranged from 0.0007 to 3.90 mSv (mean, 0.6757 mSv ± 0.8989). Calculated DAP-to-effective dose conversion factors ranged from 0.001 to 0.87 mSv/Gy · cm2 (mean, 0.210 mSv/Gy · cm2 ± 0.235) across all IR procedure types. Conclusion A pediatric fluoroscopy dose catalog was created, including age-specific effective dose, using a repeatable robust method based on accurate clinical data. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Borrego and Balter in this issue.


Subject(s)
Hospitals, Pediatric , Radiology, Interventional , Infant , Humans , Child , Retrospective Studies , Fluoroscopy , Age Factors
6.
Med Phys ; 50(7): 4234-4243, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37191309

ABSTRACT

BACKGROUND: Given the large number of readout pixels in clinical positron emission tomography (PET) scanners, signal multiplexing is an indispensable feature to reduce scanner complexity, power consumption, heat output, and cost. PURPOSE: In this paper, we introduce interleaved multiplexing (iMux) scheme that utilizes the characteristic light-sharing pattern of depth-encoding Prism-PET detector modules with single-ended readout. METHODS: In the iMux readout, four anodes from every other silicon photomultiplier (SiPM) pixels across rows and columns, which overlap with four distinct light guides, are connected to the same application-specific integrated circuit (ASIC) channel. The 4-to-1 coupled Prism-PET detector module was used which consisted of a 16 ×  16 array of 1.5 × 1.5 × 20 mm3 lutetium yttrium oxyorthosilicate (LYSO) scintillator crystals coupled to an 8 × 8 array with 3 ×  3 mm2 SiPM pixels. A deep learning-based demultiplexing model was investigated to recover the encoded energy signals. Two different experiments were performed with non-multiplexed and multiplexed readouts to evaluate the spatial, depth of interaction (DOI), and timing resolutions of our proposed iMux scheme. RESULTS: The measured flood histograms, using the decoded energy signals from our deep learning-based demultiplexing architecture, achieved perfect crystal identification of events with negligible decoding error. The average energy, DOI, and timing resolutions were 9.6 ± 1.5%, 2.9 ± 0.9 mm, and 266 ± 19 ps for non-multiplexed readout and 10.3 ± 1.6%, 2.8 ± 0.8 mm, and 311 ± 28 ps for multiplexed readout, respectively. CONCLUSIONS: Our proposed iMux scheme improves on the already cost-effective and high-resolution Prism-PET detector module and provides 16-to-1 crystal-to-readout multiplexing without appreciable performance degradation. Also, only four SiPM pixels are shorted together in the 8 ×  8 array to achieve 4-to-1 pixel-to-readout multiplexing, resulting in lower capacitance per multiplexed channel.


Subject(s)
Lutetium , Positron-Emission Tomography , Positron-Emission Tomography/methods , Lutetium/chemistry , Silicates/chemistry , Electrodes
7.
Med Phys ; 2023 Jan 18.
Article in English | MEDLINE | ID: mdl-36651630

ABSTRACT

BACKGROUND: Positron emission tomography (PET) has had a transformative impact on oncological and neurological applications. However, still much of PET's potential remains untapped with limitations primarily driven by low spatial resolution, which severely hampers accurate quantitative PET imaging via the partial volume effect (PVE). PURPOSE: We present experimental results of a practical and cost-effective ultra-high resolution brain-dedicated PET scanner, using our depth-encoding Prism-PET detectors arranged along a compact and conformal gantry, showing substantial reduction in PVE and accurate radiotracer uptake quantification in small regions. METHODS: The decagon-shaped prototype scanner has a long diameter of 38.5 cm, a short diameter of 29.1 cm, and an axial field-of-view (FOV) of 25.5 mm with a single ring of 40 Prism-PET detector modules. Each module comprises a 16 × 16 array of 1.5 × 1.5 × 20-mm3 lutetium yttrium oxyorthosillicate (LYSO) scintillator crystals coupled 4-to-1 to an 8 × 8 array of silicon photomultiplier (SiPM) pixels on one end and to a prismatoid light guide array on the opposite end. The scanner's performance was evaluated by measuring depth-of-interaction (DOI) resolution, energy resolution, timing resolution, spatial resolution, sensitivity, and image quality of ultra-micro Derenzo and three-dimensional (3D) Hoffman brain phantoms. RESULTS: The full width at half maximum (FWHM) DOI, energy, and timing resolutions of the scanner are 2.85 mm, 12.6%, and 271 ps, respectively. Not considering artifacts due to mechanical misalignment of detector blocks, the intrinsic spatial resolution is 0.89-mm FWHM. Point source images reconstructed with 3D filtered back-projection (FBP) show an average spatial resolution of 1.53-mm FWHM across the entire FOV. The peak absolute sensitivity is 1.2% for an energy window of 400-650 keV. The ultra-micro Derenzo phantom study demonstrates the highest reported spatial resolution performance for a human brain PET scanner with perfect reconstruction of 1.00-mm diameter hot-rods. Reconstructed images of customized Hoffman brain phantoms prove that Prism-PET enables accurate radiotracer uptake quantification in small brain regions (2-3 mm). CONCLUSIONS: Prism-PET will substantially strengthen the utility of quantitative PET in neurology for early diagnosis of neurodegenerative diseases, and in neuro-oncology for improved management of both primary and metastatic brain tumors.

8.
Med Phys ; 49(7): 4430-4444, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35390182

ABSTRACT

PURPOSE: Quantitative in vivo molecular imaging of fine brain structures requires high-spatial resolution and high-sensitivity. Positron emission tomography (PET) is an attractive candidate to introduce molecular imaging into standard clinical care due to its highly targeted and versatile imaging capabilities based on the radiotracer being used. However, PET suffers from relatively poor spatial resolution compared to other clinical imaging modalities, which limits its ability to accurately quantify radiotracer uptake in brain regions and nuclei smaller than 3 mm in diameter. Here we introduce a new practical and cost-effective high-resolution and high-sensitivity brain-dedicated PET scanner, using our depth-encoding Prism-PET detector modules arranged in a conformal decagon geometry, to substantially reduce the partial volume effect and enable accurate radiotracer uptake quantification in small subcortical nuclei. METHODS: Two Prism-PET brain scanner setups were proposed based on our 4-to-1 and 9-to-1 coupling of scintillators to readout pixels using 1.5 × 1.5 × 20 $1.5 \times 1.5 \times 20$  mm3 and 0.987 × 0.987 × 20 $0.987 \times 0.987 \times 20$  mm3 crystal columns, respectively. Monte Carlo simulations of our Prism-PET scanners, Siemens Biograph Vision, and United Imaging EXPLORER were performed using Geant4 application for tomographic emission (GATE). National Electrical Manufacturers Association (NEMA) standard was followed for the evaluation of spatial resolution, sensitivity, and count-rate performance. An ultra-micro hot spot phantom was simulated for assessing image quality. A modified Zubal brain phantom was utilized for radiotracer imaging simulations of 5-HT1A receptors, which are abundant in the raphe nuclei (RN), and norepinephrine transporters, which are highly concentrated in the bilateral locus coeruleus (LC). RESULTS: The Prism-PET brain scanner with 1.5 mm crystals is superior to that with 1 mm crystals as the former offers better depth-of-interaction (DOI) resolution, which is key to realizing compact and conformal PET scanner geometries. We achieved uniform 1.3 mm full-width-at-half-maximum (FWHM) spatial resolutions across the entire transaxial field-of-view (FOV), a NEMA sensitivity of 52.1 kcps/MBq, and a peak noise equivalent count rate (NECR) of 957.8 kcps at 25.2 kBq/mL using 450-650 keV energy window. Hot spot phantom results demonstrate that our scanner can resolve regions as small as 1.35 mm in diameter at both center and 10 cm away from the center of the transaixal FOV. Both 5-HT1A receptor and norepinephrine transporter brain simulations prove that our Prism-PET scanner enables accurate quantification of radiotracer uptake in small brain regions, with a 1.8-fold and 2.6-fold improvement in the dorsal RN as well as a 3.2-fold and 4.4-fold improvement in the bilateral LC compared to the Biograph Vision and EXPLORER, respectively. CONCLUSIONS: Based on our simulation results, the proposed high-resolution and high-sensitivity Prism-PET brain scanner is a promising cost-effective candidate to achieve quantitative molecular neuroimaging of small but important brain regions with PET clinically viable.


Subject(s)
Positron-Emission Tomography , Tomography, X-Ray Computed , Molecular Imaging , Phantoms, Imaging , Positron-Emission Tomography/methods , Sensitivity and Specificity
9.
Phys Med Biol ; 66(13)2021 06 30.
Article in English | MEDLINE | ID: mdl-33545696

ABSTRACT

For the first time, we propose using amorphous selenium (a-Se) as the photoconductive material for time-of-flight (TOF) detectors. Advantages of avalanche-modea-Se are having high fill factor, low excess noise due to unipolar photoconductive gain, band transport in extended states with the highest possible mobility, and negligible trapping. The major drawback ofa-Se is its poor single-photon time resolution and low carrier mobility due to shallow-traps, problems that must be circumvented for TOF applications. We propose a nanopattern multi-wella-Se detector (MWSD) to enable both impact ionization avalanche gain and unipolar time-differential (UTD) charge sensing in one device. Our experimental results show that UTD charge sensing in avalanche-modea-Se improves time-resolution by nearly 4 orders-of-magnitude. In addition, we used Cramér-Rao lower bound analysis and Monte Carlo simulations to demonstrate the viability of our MWSD for low statistics photon imaging modalities such as PET despite it being a linear-mode device. Based on our results, our device may achieve 100 ps coincidence time resolution in TOF PET with a material that is low cost and uniformly scalable to large area.


Subject(s)
Selenium , Monte Carlo Method , Positron-Emission Tomography
10.
Med Phys ; 48(3): 1019-1025, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33305482

ABSTRACT

PURPOSE: Depth of interaction (DOI) readout in PET imaging has been researched in efforts to mitigate parallax error, which would enable the development of small diameter, high-resolution PET scanners. However, DOI PET has not yet been commercialized due to the lack of practical, cost-effective, and data efficient DOI readout methods. The rationale for this study was to develop a supervised machine learning algorithm for DOI estimation in PET that can be trained and deployed on unique sets of crystals. METHODS: Depth collimated flood data was experimentally acquired using a Na-22 source with a depth-encoding single-ended readout Prism-PET module consisting of lutetium yttrium orthosilicate (LYSO) crystals coupled 4-to-1 to 3×3  mm 2 silicon photomultiplier (SiPM) pixels on one end and a segmented prismatoid light guide array on the other end. A convolutional neural network (CNN) was trained to perform DOI estimation on data from center, edge and corner crystals in the Prism-PET module using (a) all non-zero readout pixels and (b) only the 4 highest readout signals per event. CNN testing was performed on data from crystals not included in CNN training. RESULTS: An average DOI resolution of 1.84 mm full width at half maximum (FWHM) across all crystals was achieved when using all readout signals per event with the CNN compared to 3.04 mm FWHM DOI resolution using classical estimation. When using only the 4 highest signals per event, an average DOI resolution of 1.92 mm FWHM was achieved, representing only a 4% dropoff in CNN performance compared to using all non-zero pixels per event. CONCLUSIONS: Our CNN-based DOI estimation algorithm provides the best reported DOI resolution in a single-ended readout module and can be readily deployed on crystals not used for model training.


Subject(s)
Neural Networks, Computer , Positron-Emission Tomography , Tomography, X-Ray Computed , Algorithms , Humans
11.
Phys Med Biol ; 65(18): 18LT01, 2020 09 16.
Article in English | MEDLINE | ID: mdl-32413872

ABSTRACT

High spatial resolution PET relies on having excellent depth-of-interaction (DOI) resolution and small detector elements. Depth-encoding in PET modules has traditionally been performed using dual-ended readout. In recent years, researchers have explored the feasibility of replacing the second readout array with a light guide at the entrance layer that introduces intercrystal light sharing in order to reduce cost and and make depth-encoding modules more compact. However, single-ended readout depth-encoding modules have suboptimal and non-uniform crystal separation and DOI performance due to the random light sharing patterns of the uniform light guide, resulting in degraded peformance along the edges and corners of the detector arrays. In this paper, we introduce and characterize a segmented light guide composed of an array of prism mirrors which introduce deterministic intercrystal light sharing in single-ended readout PET detectors. We determined the expected spatial performance of our modules with our light guide using optical ray tracing Monte Carlo simulations. We demonstrate that having controlled, deterministic light sharing improves both DOI and crystal identification performance, enabling uniform spatial performance throughout the detector array. Designed specifically for high resolution PET, our prismatoid light guide array can be used to build cost-effective total-body and organ-dedicated PET systems with single-ended readout depth-encoding modules.


Subject(s)
Gamma Rays , Monte Carlo Method , Photons , Positron-Emission Tomography/methods , Equipment Design , Positron-Emission Tomography/instrumentation
12.
J Nucl Med ; 61(10): 1528-1533, 2020 10.
Article in English | MEDLINE | ID: mdl-32111684

ABSTRACT

Depth-encoding detectors with single-ended readout provide a practical, cost-effective approach for constructing high-resolution and high-sensitivity PET scanners. However, the current iteration of such detectors uses a uniform glass light-guide to achieve depth encoding, resulting in nonuniform performance throughout the detector array due to suboptimal intercrystal light sharing. We introduce Prism-PET, a single-ended-readout PET detector module with a segmented light-guide composed of an array of prismatoids that introduce enhanced, deterministic light sharing. Methods: High-resolution PET detector modules were fabricated with single-ended readout of polished multicrystal lutetium yttrium orthosilicate scintillator arrays directly coupled 4-to-1 and 9-to-1 to arrays of 3 × 3 mm silicon photomultiplier pixels. Each scintillator array was coupled at the nonreadout side to a light-guide (one 4-to-1 module with a uniform glass light-guide, one 4-to-1 Prism-PET module, and one 9-to-1 Prism-PET module) to introduce intercrystal light sharing, which closely mimics the behavior of dual-ended readout, with the additional benefit of improved crystal identification. Flood histogram data were acquired using a 3-MBq 22Na source to characterize crystal identification and energy resolution. Lead collimation was used to acquire data at specific depths to determine depth-of-interaction (DOI) resolution. Results: The flood histogram measurements showed excellent and uniform crystal separation throughout the Prism-PET modules, whereas the uniform glass light-guide module had performance degradation at the edges and corners. A DOI resolution of 5.0 mm full width at half maximum (FWHM) and an energy resolution of 13% FWHM were obtained in the uniform glass light-guide module. By comparison, the 4-to-1 coupled Prism-PET module achieved a DOI resolution of 2.5 mm FWHM and an energy resolution of 9% FWHM. Conclusion: PET scanners based on our Prism-PET modules with segmented prismatoid light-guide arrays can achieve high and uniform spatial resolution (9-to-1 coupling with ∼1-mm crystals), high sensitivity (20-mm-thick detectors and intercrystal Compton scatter recovery), good energy and timing resolutions (using polished crystals and after applying DOI correction), and compact size (depth encoding eliminates parallax error and permits smaller ring-diameter).


Subject(s)
Positron-Emission Tomography/methods , Equipment Design , Humans , Light , Lutetium , Silicates
13.
ACS Photonics ; 6(6): 1338-1344, 2019 Jun 19.
Article in English | MEDLINE | ID: mdl-38665849

ABSTRACT

Ultrafast photodetection has traditionally been performed with crystalline photodetectors, which tend to suffer from low production yield, suboptimal detection efficiency, and operational limitations that restrict their potential applications. Amorphous selenium is a unique, disordered photosensing material in which carrier transport can be shifted entirely from localized to extended states where holes get hot, resulting in deterministic, non-Markovian impact ionization avalanche, causing selenium to exhibit characteristics similar to crystalline photoconductors. For the first time, we have fabricated a multiwell selenium detector using nanopillars that achieves both avalanche gain and unipolar time-differential charge sensing. We experimentally show how these features together improve selenium's temporal performance by nearly 4 orders of magnitude, allowing us to achieve picosecond timing jitter suitable for a variety of ultrafast applications. Such a detector would be a viable low-cost, high production yield alternative for picosecond photodetection and imaging.