Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Clin Nutr ; 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38454153

ABSTRACT

BACKGROUND: The precision of digital anthropometry through 3-dimensional (3D) scanning has been established for relatively large, expensive, non-portable systems. The comparative performance of modern mobile applications is unclear. SUBJECTS/METHODS: Forty-six adults (age: 23.3 ± 5.3 y; BMI: 24.4 ± 4.1 kg/m2) were assessed in duplicate using: (1) a mobile phone application capturing two individual 2D images, (2) a mobile phone application capturing serial images collected during a subject's complete rotation, (3) a traditional scanner with a time of flight infrared sensor collecting visual data from a subject being rotated on a mechanical turntable, and (4) a commercial measuring booth with structured light technology using 20 infrared depth sensors positioned in the booth. The absolute and relative technical error of measurement (TEM) and intraclass correlation coefficient (ICC) for each method were established. RESULTS: Averaged across circumferences, the absolute TEM, relative TEM, and ICC were (1) 0.9 cm, 1.5%, and 0.975; (2) 0.5 cm, 0.9%, and 0.986; (3) 0.8 cm, 1.5%, and 0.974; and (4) 0.6 cm, 1.1%, and 0.985. For total body volume, these values were (1) 2.2 L, 3.0%, and 0.978; (2) 0.8 L, 1.1%, and 0.997; (3) 0.7 L, 0.9%, and 0.998; and (4) 0.8 L, 1.1%, and 0.996, with segmental volumes demonstrating higher relative errors. CONCLUSION: A 3D scanning mobile phone application involving full rotation of subjects in front of a smartphone camera exhibited similar reliability to larger, less portable, more expensive 3D scanners. In contrast, larger errors were observed for a mobile scanning application utilizing two 2D images, although the technical errors were acceptable for some applications.

2.
Nutrients ; 15(22)2023 Nov 17.
Article in English | MEDLINE | ID: mdl-38004200

ABSTRACT

Multi-ingredient thermogenic supplements can acutely increase resting energy expenditure (REE) and subjective energy. However, less is understood about the effects of chronic consumption on body composition, metabolism, and subjective variables such as mood, sleep quality, and eating behaviors. Fifty-two healthy, exercise-trained participants (50% female; mean ± SD age: 23.5 ± 3.0 years; body fat percentage: 27.3 ± 8.0%) were randomized 2:2:1 to take a whey protein supplement alone (PRO; n = 20), in combination with a thermogenic supplement (PRO + FB; n = 19), or no supplement at all (CON; n = 13) for four weeks. Body composition, anthropometric, metabolic, hemodynamic, and subjective outcomes were collected before and after the intervention. Greater changes in REE occurred in PRO + FB as compared to CON (111.2 kcal/d, 95% CI 2.4 to 219.9 kcal/d, p = 0.04), without significant differences between PRO and CON (42.7 kcal/d, 95% CI -65.0 to 150.3 kcal/d, p = 0.61) or between PRO + FB and PRO (68.5 kcal/d, 95% CI -28.3, 165.3, p = 0.21). No changes in hemodynamic outcomes (blood pressure and heart rate) were observed. In exercising adults, four weeks of supplementation with protein and a multi-ingredient thermogenic product maintained fasted REE as compared to no supplementation, for which a decrease in REE was observed, without differential effects on body composition, anthropometrics, or subjective variables.


Subject(s)
Dietary Supplements , Energy Metabolism , Adult , Humans , Female , Young Adult , Male , Body Composition , Anthropometry , Hemodynamics
3.
Eur J Clin Nutr ; 77(12): 1151-1159, 2023 12.
Article in English | MEDLINE | ID: mdl-37591970

ABSTRACT

BACKGROUND/OBJECTIVES: Skeletal muscle mass (SMM) estimation is important but challenging in clinical settings. Criterion methods, such as magnetic resonance imaging (MRI), are often inaccessible. However, surrogate methods, such as dual-energy X-ray absorptiometry (DXA) and multi-frequency bioelectrical impedance analysis (MFBIA), can use MRI-based equations to estimate SMM, although the agreement between these methods is unclear. SUBJECTS/METHODS: Total and segmental SMM were estimated with DXA and MFBIA using MRI-based equations in 313 healthy adults (120 M, 193 F; age 30.2 ± 13.0 y; BMI 24.6 ± 4.0 kg/m2). DXA total SMM was estimated using the Kim and McCarthy equations, and segmental SMM was estimated using the McCarthy equations. Relationships between DXA and MFBIA SMM were examined using Deming regression, Lin's concordance correlation coefficient (CCC), equivalence testing, Bland-Altman analysis, and related tests. RESULTS: Strong linear relationships were observed for total (R2 0.95, CCC 0.96-0.97), leg (R2 0.90, CCC 0.85) and arm (R2 0.93, CCC 0.93) SMM in the entire sample. Kim equation SMM demonstrated statistical equivalence with MFBIA for total SMM, but the Deming regression slope differed from 1 and proportional bias was present. McCarthy equation total SMM exhibited a regression slope that did not differ from 1, and no proportional bias was present in the entire sample. However, equivalence with MFBIA was not observed. Systematically higher leg and arm SMM values were observed with DXA as compared to MFBIA. CONCLUSIONS: While DXA and MFBIA total SMM generally exhibited strong agreement, higher appendicular SMM by DXA highlights technical differences between methods.


Subject(s)
Body Composition , Muscle, Skeletal , Adult , Humans , Adolescent , Young Adult , Absorptiometry, Photon/methods , Electric Impedance , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Magnetic Resonance Imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...