1.
Eur Radiol ; 33(8): 5476-5488, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36920517

ABSTRACT

OBJECTIVES: To evaluate the quality of virtual monochromatic images (VMIs) from spectral photon-counting CT (SPCCT) and two energy-integrating detector dual-energy CT (EID-DECT) scanners from the same manufacturer, for the coronary lumen. METHODS: A 21-cm section of the Mercury v4.0 phantom was scanned using a cardiac CT protocol. VMIs from 40 to 90 keV were reconstructed using high-resolution (HR) parameters for EID-DECT and SPCCT (CB and HRB kernels at 0.67 mm slice thickness, respectively). Ultra-high-resolution (UHR) parameters were used in addition to SPCCT (detailed-2 kernel, 0.43 mm slice thickness). Noise-power-spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were computed for 2-mm-diameter lumen detection. In consensus, two radiologists analyzed the quality of the images from 8 patients who underwent coronary CTA on both CT systems. RESULTS: For all keV images, fpeak, f50, and d' were higher with SPCCT. The fpeak and f50 were higher with UHR-SPCCT with greater noise and lower d' compared to those of the HR-SPCCT images. Noise magnitude was constant for all energy levels (keV) with both systems, and lower with HR images, and d' decreased as keV decreased. Subjective analysis showed greater lumen sharpness and overall quality for HR and UHR-SPCCT images using all keV, with a greater difference at low keV compared to HR-EID-DECT images. CONCLUSION: HR and UHR-SPCCT images gave greater detectability of the coronary lumen for 40 to 90 keV VMIs compared to two EID-DECT systems, with benefits of higher lumen sharpness and overall quality. KEY POINTS: • Compared with 2 dual-energy CT systems, spectral photon-counting CT (SPCCT) improved spatial resolution, noise texture, noise magnitude, and detectability of the coronary lumen. • Use of ultra-high-resolution parameters with SPCCT improved spatial resolution and noise texture and provided high detectability of the coronary lumen, despite an increase in noise magnitude. • In eight patients, radiologists found greater overall image quality with SPCCT for all virtual monochromatic images with a greater difference at low keV, compared with dual-energy CT systems.


Subject(s)
Coronary Vessels , Tomography, X-Ray Computed , Humans , Coronary Vessels/diagnostic imaging , Tomography, X-Ray Computed/methods , Phantoms, Imaging , Heart , Photons
2.
EJNMMI Phys ; 8(1): 56, 2021 Jul 27.
Article in English | MEDLINE | ID: mdl-34318383

ABSTRACT

BACKGROUND: PET imaging of 90Y-microsphere distribution following radioembolisation is challenging due to the count-starved statistics from the low branching ratio of e+/e- pair production during 90Y decay. PET systems using silicon photo-multipliers have shown better 90Y image quality compared to conventional photo-multiplier tubes. The main goal of the present study was to evaluate reconstruction parameters for different phantom configurations and varying listmode acquisition lengths to improve quantitative accuracy in 90Y dosimetry, using digital photon counting PET/CT. METHODS: Quantitative PET and dosimetry accuracy were evaluated using two uniform cylindrical phantoms specific for PET calibration validation. A third body phantom with a 9:1 hot sphere-to-background ratio was scanned at different activity concentrations of 90Y. Reconstructions were performed using OSEM algorithm with varying parameters. Time-of-flight and point-spread function modellings were included in all reconstructions. Absorbed dose calculations were carried out using voxel S-values convolution and were compared to reference Monte Carlo simulations. Dose-volume histograms and root-mean-square deviations were used to evaluate reconstruction parameter sets. Using listmode data, phantom and patient datasets were rebinned into various lengths of time to assess the influence of count statistics on the calculation of absorbed dose. Comparisons between the local energy deposition method and the absorbed dose calculations were performed. RESULTS: Using a 2-mm full width at half maximum post-reconstruction Gaussian filter, the dosimetric accuracy was found to be similar to that found with no filter applied but also reduced noise. Larger filter sizes should not be used. An acquisition length of more than 10 min/bed reduces image noise but has no significant impact in the quantification of phantom or patient data for the digital photon counting PET. 3 iterations with 10 subsets were found suitable for large spheres whereas 1 iteration with 30 subsets could improve dosimetry for smaller spheres. CONCLUSION: The best choice of the combination of iterations and subsets depends on the size of the spheres. However, one should be careful on this choice, depending on the imaging conditions and setup. This study can be useful in this choice for future studies for more accurate 90Y post-dosimetry using a digital photon counting PET/CT.

3.
Phys Med Biol ; 66(10)2021 05 14.
Article in English | MEDLINE | ID: mdl-33770774

ABSTRACT

Built on top of the Geant4 toolkit, GATE is collaboratively developed for more than 15 years to design Monte Carlo simulations of nuclear-based imaging systems. It is, in particular, used by researchers and industrials to design, optimize, understand and create innovative emission tomography systems. In this paper, we reviewed the recent developments that have been proposed to simulate modern detectors and provide a comprehensive report on imaging systems that have been simulated and evaluated in GATE. Additionally, some methodological developments that are not specific for imaging but that can improve detector modeling and provide computation time gains, such as Variance Reduction Techniques and Artificial Intelligence integration, are described and discussed.


Subject(s)
Artificial Intelligence , Software , Computer Simulation , Monte Carlo Method , Tomography, X-Ray Computed
4.
Phys Med Biol ; 66(4): 045009, 2021 02 02.
Article in English | MEDLINE | ID: mdl-33296874

ABSTRACT

The benefits of using an algorithm that reports absorbed dose-to-medium have been jeopardized by the clinical experience and the experimental protocols that have mainly relied on absorbed dose-to-water. The aim of the present work was to investigate the physical aspects that govern the dosimetry in heterogeneous media using Monte Carlo method and to introduce a formalism for the experimental validation of absorbed dose-to-medium reporting algorithms. Particle fluence spectra computed within the sensitive volume of two simulated detectors (T31016 Pinpoint 3D ionization chamber and EBT3 radiochromic film) placed in different media (water, RW3, lung and bone) were compared to those in the undisturbed media for 6 MV photon beams. A heterogeneity correction factor that takes into account the difference between the detector perturbation in medium and under reference conditions as well as the stopping-power ratios was then derived for all media using cema calculations. Furthermore, the different conversion approaches and Eclipse treatment planning system algorithms were compared against the Monte Carlo absorbed dose reports. The detectors electron fluence perturbation in RW3 and lung media were close to that in water (≤1.5%). However, the perturbation was greater in bone (∼4%) and impacted the spectral shape. It was emphasized that detectors readings should be corrected by the heterogeneity correction factor that ranged from 0.932 in bone to 0.985 in lung. Significant discrepancies were observed between all the absorbed dose reports and conversions, especially in bone (exceeding 10%) and to a lesser extent in RW3. Given the ongoing advances in dose calculation algorithms, it is essential to standardize the absorbed dose report mode with absorbed dose-to-medium as a favoured choice. It was concluded that a retrospective conversion should be avoided and switching from absorbed dose-to-water to absorbed dose-to-medium reporting algorithm should be carried out by a direct comparison of both algorithms.


Subject(s)
Photons , Radiation Dosage , Research Design/standards , Algorithms , Humans , Monte Carlo Method , Reference Standards , Water
5.
EJNMMI Phys ; 7(1): 23, 2020 Apr 25.
Article in English | MEDLINE | ID: mdl-32335787

ABSTRACT

A GATE Monte Carlo model of the Philips Vereos digital photon counting PET imaging system using silicon photo-multiplier detectors was proposed. It was evaluated against experimental data in accordance with NEMA guidelines. Comparisons were performed using listmode data in order to remain independent of image reconstruction algorithms. An original line of response-based method is proposed to estimate intrinsic spatial resolution without reconstruction. Four sets of experiments were performed: (1) count rates and scatter fraction, (2) energy and timing resolutions, (3) sensitivity, and (4) intrinsic spatial resolution. Experimental and simulated data were found to be in good agreement, with overall differences lower than 10% for activity concentrations used in most standard clinical applications. Illustrative image reconstructions were provided. In conclusion, the proposed Monte Carlo model was validated and can be used for numerous studies such as optimizing acquisition parameters or reconstruction algorithms.