Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Biomedicines ; 12(4)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38672223

ABSTRACT

To date, studies assessing the safety profile of 3D printing materials for application in cardiac ablation are sparse. Our aim is to evaluate the safety and feasibility of two biocompatible 3D printing materials, investigating their potential use for intra-procedural guides to navigate surgical cardiac arrhythmia ablation. Herein, we 3D printed various prototypes in varying thicknesses (0.8 mm-3 mm) using a resin (MED625FLX) and a thermoplastic polyurethane elastomer (TPU95A). Geometrical testing was performed to assess the material properties pre- and post-sterilization. Furthermore, we investigated the thermal propagation behavior beneath the 3D printing materials during cryo-energy and radiofrequency ablation using an in vitro wet-lab setup. Moreover, electron microscopy and Raman spectroscopy were performed on biological tissue that had been exposed to the 3D printing materials to assess microparticle release. Post-sterilization assessments revealed that MED625FLX at thicknesses of 1 mm, 2.5 mm, and 3 mm, along with TPU95A at 1 mm and 2.5 mm, maintained geometrical integrity. Thermal analysis revealed that material type, energy source, and their factorial combination with distance from the energy source significantly influenced the temperatures beneath the 3D-printed material. Electron microscopy revealed traces of nitrogen and sulfur underneath the MED625FLX prints (1 mm, 2.5 mm) after cryo-ablation exposure. The other samples were uncontaminated. While Raman spectroscopy did not detect material release, further research is warranted to better understand these findings for application in clinical settings.

2.
J Chem Phys ; 157(16): 164703, 2022 Oct 28.
Article in English | MEDLINE | ID: mdl-36319421

ABSTRACT

Two-dimensional (2D) allotropes of tellurium (Te), recently coined as tellurene, are currently an emerging topic of materials research due to the theoretically predicted exotic properties of Te in its ultrathin form and at the single atomic layer limit. However, a prerequisite for the production of such new and single elemental 2D materials is the development of simple and robust fabrication methods. In the present work, we report three different 2D superstructures of Te on Au(111) surfaces by following an alternative experimental deposition approach. We have investigated the superstructures using low-temperature scanning tunneling microscopy and spectroscopy, Auger electron spectroscopy (AES), and field emission AES. Three superstructures (13 × 13, 8 × 4, and √11 × âˆš11) of 2D Te are observed in our experiments, and the formation of these superstructures is accompanied by the lifting of the characteristic 23 × âˆš3 surface reconstruction of the Au(111) surface. Scanning tunneling spectroscopy reveals a strong dependence of the local electronic properties on the structural arrangement of the Te atoms on the Au(111) support, and we observe superstructure-dependent electronic resonances around the Fermi level and below the Au(111) conduction band. In addition to the appearance of the new electronic resonances, the emergence of band gaps with a p-type charge character has been evidenced for two out of three Te superstructures (13 × 13 and √11 × âˆš11) on the Au(111) support.

3.
Electrophoresis ; 41(15): 1287-1295, 2020 08.
Article in English | MEDLINE | ID: mdl-32358839

ABSTRACT

In the present study, cylindrical and laterally elongated pillar array columns were investigated for use in capillary electrochromatography. Minimal theoretical plate heights of H = 1.90 and 1.46 µm (in absence of sidewall effect) were obtained for coumarin C440 under unretained conditions for cylindrical and rectangular (laterally elongated, aspect ratio 4) pillar array columns, respectively. By comparing dispersion at the entire channel width to that at the central zone only, it appears that sidewall related dispersion significantly contributes to overall dispersion. A 40% reduction of the plate height was observed by taking into account only the central channel zone. A kinetic plot analysis was performed to evaluate the potential of the studied geometries by considering a maximum operating voltage of 20 kV as limiting parameter. It was demonstrated that rectangular radially elongated pillars produce a higher efficiency than cylindrical pillars and other microfabricated column structures for microchip capillary electrochromatography previously studied.


Subject(s)
Capillary Electrochromatography , Lab-On-A-Chip Devices , Capillary Electrochromatography/instrumentation , Capillary Electrochromatography/methods , Coumarins/analysis , Coumarins/isolation & purification , Equipment Design
SELECTION OF CITATIONS
SEARCH DETAIL
...