Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
2.
Hong Kong Med J ; 23(3): 239-45, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28211358

ABSTRACT

INTRODUCTION: Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. METHODS: This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. RESULTS: A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. CONCLUSIONS: Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter-associated urinary tract infection based on the latest surveillance definition. The effect is perhaps more prominent in long-term users and female patients.


Subject(s)
Catheter-Related Infections/prevention & control , Cross Infection/prevention & control , Urinary Catheterization/adverse effects , Urinary Tract Infections/prevention & control , Aged , Aged, 80 and over , Alloys , Catheter-Related Infections/epidemiology , Catheters, Indwelling , Cross Infection/epidemiology , Female , Humans , Hydrogels , Incidence , Male , Prospective Studies , Sex Factors , Silver/chemistry , Time Factors , Urinary Catheterization/instrumentation , Urinary Tract Infections/epidemiology
3.
Hong Kong Med J ; 23(2): 140-9, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28232642

ABSTRACT

INTRODUCTION: Apart from individual small-scale outbreaks, infections with vancomycin-resistant enterococci are uncommon in Hong Kong. A major outbreak of vancomycin-resistant enterococci, however, occurred at a large tertiary hospital in 2013. We describe the successful control of this outbreak and share the lessons learned. METHODS: In 2013, there was an abnormal increase in the incidence of vancomycin-resistant enterococci carriage compared with baseline in multiple clinical departments at Queen Elizabeth Hospital. A multipronged approach was adopted that included a 10-week hospital-wide active screening programme, which aimed to identify and isolate hidden vancomycin-resistant enterococci carriers among all in-patients. The identified carriers were completely segregated in designated wards where applicable. Other critical infection control measures included directly observed hand hygiene and environmental hygiene. A transparent and open disclosure approach was adopted throughout the outbreak. RESULTS: The infection control measures were successfully implemented. The active screening of vancomycin-resistant enterococci was conducted between 30 September and 10 November 2013. A total of 7053 rectal swabs were collected from patients in 46 hospital wards from 11 departments. The overall carriage rate of vancomycin-resistant enterococci was 2.8% (201/7053). Pulsed-field gel electrophoresis showed a predominant outbreak clone. We curbed the outbreak and kept the colonisation of vancomycin-resistant enterococci among patients at a pre-upsurge low level. CONCLUSIONS: We report the largest cohesive effort to control spread of vancomycin-resistant enterococci in Hong Kong. Coupled with other infection control measures, we successfully controlled vancomycin-resistant enterococci to the pre-outbreak level. We have demonstrated that the monumental tasks can be achieved with meticulous planning, and thorough communication and understanding between all stakeholders.


Subject(s)
Cross Infection/prevention & control , Gram-Positive Bacterial Infections/prevention & control , Infection Control/methods , Vancomycin Resistance , Vancomycin-Resistant Enterococci/isolation & purification , Adult , Aged , Anti-Bacterial Agents/pharmacology , Cross Infection/microbiology , Disease Outbreaks , Electrophoresis, Gel, Pulsed-Field , Feces/microbiology , Female , Gram-Positive Bacterial Infections/microbiology , Hand Disinfection , Hong Kong/epidemiology , Humans , Length of Stay , Logistic Models , Male , Middle Aged , Patient Isolation , Tertiary Care Centers
SELECTION OF CITATIONS
SEARCH DETAIL
...