Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Rev Sci Instrum ; 91(11): 113201, 2020 Nov 01.
Article in English | MEDLINE | ID: mdl-33261421

ABSTRACT

We present the design and construction of a new experimental apparatus for the trapping of single Ba+ ions in the center of curvature of an optical-quality hemispherical mirror. We describe the layout, fabrication, and integration of the full setup, consisting of a high-optical access monolithic "3D-printed" Paul trap, the hemispherical mirror, a diffraction-limited in-vacuum lens (NA = 0.7) for collection of atomic fluorescence, and a state-of-the art ultra-high vacuum vessel. This new apparatus enables the study of quantum electrodynamics effects such as strong inhibition and enhancement of spontaneous emission and achieves a collection efficiency of the emitted light in a single optical mode of 31%.

2.
Rev Sci Instrum ; 90(8): 083201, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31472618

ABSTRACT

The lifetime of trapped ion ensembles corresponds to a crucial parameter determining the potential scalability of their prospective applications and is often limited by the achievable vacuum level in the apparatus. We report on the realization of a room-temperature 40Ca+ ion trapping vacuum apparatus with unprecedentedly low reaction rates of ions with a dominant vacuum contaminant: hydrogen. We present our trap assembly procedures and hydrogen pressure characterization by analysis of the CaH+ molecule formation rate.

3.
Rev Sci Instrum ; 87(11): 113103, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910317

ABSTRACT

We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120 dB reduction of 50 Hz noise along the magnetic field axis. We combine this efficient magnetic shielding with high optical access required for single ion addressing as well as for efficient state detection by placing two lenses each with numerical aperture 0.23 inside the inner heat shield. The cryostat design incorporates vibration isolation to avoid decoherence of optical qubits due to the motion of the cryostat. We measure vibrations of the cryostat of less than ±20 nm over 2 s. In addition to the cryogenic apparatus, we describe the setup required for an operation with 40Ca+ and 88Sr+ ions. The instability of the laser manipulating the optical qubits in 40Ca+ is characterized by yielding a minimum of its Allan deviation of 2.4 ⋅ 10-15 at 0.33 s. To evaluate the performance of the apparatus, we trapped 40Ca+ ions, obtaining a heating rate of 2.14(16) phonons/s and a Gaussian decay of the Ramsey contrast with a 1/e-time of 18.2(8) ms.

SELECTION OF CITATIONS
SEARCH DETAIL