Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Ophthalmol ; 2024 May 23.
Article in English | MEDLINE | ID: mdl-38795748

ABSTRACT

PURPOSE: To apply retinal nerve fiber layer (RNFL) optical texture analysis (ROTA) to 1) investigate the association between papillomacular and papillofoveal bundle defects with 10-2 visual field (VF) sensitivity abnormalities, and 2) integrate the information from RNFL bundle defect and 24-2 VF central test locations to determine the likelihood of 10-2 VF sensitivity abnormalities. DESIGN: Cross-sectional METHODS: A total of 841 eyes (144 healthy, 317 glaucoma suspect, and 380 glaucoma) of 442 participants were included. Eyes underwent 24-2, and 10-2 VF testing and OCT for ROTA. The borders of RNFL defects were delineated from ROTA, and the involvement of the arcuate, papillomacular, and papillofoveal bundles was determined for each eye. Multilevel logistic regression analysis was applied to evaluate the structure-function association. RESULTS: Papillomacular (92.1%) and papillofoveal (37.9%) RNFL bundle defects were prevalent in eyes with glaucoma. A 10-2 VF location that was projected onto a papillomacular or a papillofoveal RNFL bundle defect had a significantly increased likelihood of reduced sensitivity (ORs of 18.61 at PDP < 5%, and 20.17 at TDP < 5%, respectively, P < 0.001 for both). When predicting the likelihood of VF abnormality in a 10-2 test location, noticeably higher odds ratios were observed when overlapping with an RNFL bundle defect, compared to when an abnormal corresponding 24-2 central point was present. CONCLUSIONS: Papillomacular and papillofoveal RNFL bundle defects are present in a considerable proportion of eyes with glaucoma. When detected, they significantly increase the likelihood of abnormality in the corresponding central VF test locations assessed by the 10-2 test.

2.
Ophthalmology ; 129(9): 1043-1055, 2022 09.
Article in English | MEDLINE | ID: mdl-35469924

ABSTRACT

PURPOSE: To apply retinal nerve fiber layer (RNFL) optical texture analysis (ROTA) in eyes with early glaucoma to investigate (1) the pattern of RNFL defects, (2) how often the papillomacular bundle and papillofoveal bundles are involved, and (3) the association between papillomacular and papillofoveal bundle defects and visual field (VF) sensitivity abnormalities. DESIGN: Cross-sectional study. PARTICIPANTS: Two hundred four eyes with early glaucoma (VF mean deviation, ≥ -6 dB) with RNFL defects from 171 consecutively enrolled patients with glaucoma. METHODS: All eyes underwent 24-2 VF testing and OCT for ROTA. The borders of RNFL defects were delineated from ROTA, and the involvement of the arcuate bundle, papillomacular bundle (i.e., bundles from the macula, excluding the fovea), and papillofoveal bundle (i.e., bundles from the fovea) was determined for each eye. Multilevel logistic regression analysis was applied to evaluate the structure-function association. MAIN OUTCOME MEASURES: Proportions of eyes with papillomacular or papillofoveal bundle defects. RESULTS: Of the 204 eyes, 71.6% and 17.2% demonstrated RNFL defects involving the papillomacular and papillofoveal bundles, respectively; 25.0% showed arcuate bundle defects without involvement of papillomacular or papillofoveal bundles. The pattern of RNFL defects was diverse; the most common was concomitant involvement of the inferior arcuate bundle and the inferior papillomacular bundle (20.6%). Papillomacular or papillofoveal bundle defects were not associated with VF defects (i.e., with ≥ 3 contiguous locations with abnormal VF sensitivity in the pattern deviation probability plot) in the corresponding hemifield, although VF sensitivity of any 1 of the central 4 VF locations of the 24-2 test, which were within the macula, was more likely to be abnormal (P < 0.05 in the pattern deviation probability plot; odds ratio, 12.5; 95% confidence interval, 7.0-22.5) when the VF stimulus was projected onto a papillomacular or papillofoveal bundle defect than that projected onto an intact papillomacular or papillofoveal bundle. CONCLUSIONS: Contrary to the conventional notion that the fovea and macula are not affected until the late stages of glaucoma, papillofoveal and papillomacular bundle defects were common in early glaucoma, and they were associated with central VF sensitivity loss at the corresponding VF test locations.


Subject(s)
Glaucoma , Nerve Fibers , Cross-Sectional Studies , Glaucoma/diagnosis , Humans , Intraocular Pressure , Retinal Ganglion Cells , Scotoma , Tomography, Optical Coherence , Visual Field Tests
4.
JAMA Ophthalmol ; 138(5): 490-498, 2020 05 01.
Article in English | MEDLINE | ID: mdl-32191274

ABSTRACT

Importance: Clinical assessment of vision-related disability is hampered by the lack of instruments to assess visual performance in real-world situations. Interactive virtual reality (VR) environments displayed in a binocular stereoscopic VR headset have been designed, presumably simulating day-to-day activities to evaluate vision-related disability. Objective: To investigate the application of VR to identify vision-related disability in patients with glaucoma. Design, Setting, and Participants: In a cross-sectional study, 98 patients with glaucoma and 50 healthy individuals were consecutively recruited from a university eye clinic; all participants were Chinese. The study was conducted between August 30, 2016, and July 31, 2017; data analysis was performed from December 1, 2017, to October 30, 2018. Exposures: Measurements of visual acuity, contrast sensitivity, visual field (VF), National Eye Institute 25-item Visual Function Questionnaire Rasch score, and VR disability scores determined from 5 VR simulations: supermarket shopping, stair and city navigations in daytime, and stair and city navigations in nighttime. Duration required to complete the simulation, number of items incorrectly identified, and number of collisions were measured to compute task-specific and overall VR disability scores. Vision-related disability was identified when the VR disability score was outside the normal age-adjusted 95% confidence region. Main Outcomes and Measures: Virtual reality disability score. Results: In the 98 patients with glaucoma, mean (SD) age was 49.8 (11.6) years and 60 were men (61.2%); in the 50 healthy individuals, mean (SD) age was 48.3 (14.8) years and 16 were men (32.0%). The patients with glaucoma had different degrees of VF loss (122 eyes [62.2%] had moderate or advanced VF defects). The time required to complete the activities by patients with glaucoma vs healthy individuals was longer by 15.2 seconds (95% CI, 5.5-24.9 seconds) or 34.1% (95% CI, 12.4%-55.7%) for the shopping simulation, 72.8 seconds (95% CI, 23.0-122.6 seconds) or 33.8% (95% CI, 10.7%-56.9%) for the nighttime stair navigation, and 38.1 seconds (95% CI, 10.9-65.2 seconds) or 30.8% (95% CI, 8.8%-52.8%) for the nighttime city navigation. The mean (SD) duration was not significantly different between the glaucoma and healthy groups in daytime stair (203.7 [93.7] vs 192.9 [89.1] seconds, P = .52) and city (118.7 [41.5] vs 117.0 [52.3] seconds, P = .85) navigation. For each decibel decrease in binocular VF sensitivity, the risk of collision increased by 15% in nighttime stair (hazard ratio [HR], 1.15; 95% CI, 1.08-1.22) and city (HR, 1.15; 95% CI, 1.08-1.23) navigations. Fifty-eight patients (59.1%) with glaucoma had vision-related disability in at least 1 simulated daily task; a higher proportion of patients had vision-related disability in nighttime city (27 of 88 [30.7%]) and stair (27 of 90 [30.0%]) navigation than in daytime city (7 of 88 [8.0%]) and stair (19 of 96 [19.8%]) navigation. The overall VR disability score was associated with the National Eye Institute 25-item Visual Function Questionnaire Rasch score (R2 = 0.207). Conclusions and Relevance: These findings suggest that vision-related disability is associated with lighting condition and task in patients with glaucoma. Virtual reality may allow eye care professionals to understand the patients' perspectives on how visual impairment imparts disability in daily living and provide a new paradigm to augment the assessment of vision-related disability.


Subject(s)
Disability Evaluation , Glaucoma, Angle-Closure/diagnosis , Glaucoma, Open-Angle/diagnosis , Virtual Reality , Vision Disorders/diagnosis , Activities of Daily Living , Adult , Aged , Computer Simulation , Cross-Sectional Studies , Female , Glaucoma, Angle-Closure/physiopathology , Glaucoma, Open-Angle/physiopathology , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Sickness Impact Profile , Surveys and Questionnaires , Vision Disorders/physiopathology , Vision, Binocular/physiology , Visual Acuity/physiology , Visual Fields/physiology
5.
JAMA Ophthalmol ; 136(8): 866-874, 2018 08 01.
Article in English | MEDLINE | ID: mdl-29852029

ABSTRACT

Importance: Whether optical coherence tomography angiography (OCT-A) outperforms OCT to detect glaucoma remains inconclusive. Objective: To compare (1) the diagnostic performance for detection of glaucoma and (2) the structure-function association between inner macular vessel density and inner macular thickness. Design, Setting, and Participants: This cross-sectional study included 115 patients with glaucoma and 35 healthy individuals for measurements of retinal thickness and retinal vessel density, segmented between the anterior boundary of internal limiting membrane and the posterior boundary of the inner plexiform layer, over the 3 × 3-mm2 macula using swept-source OCT. All participants were Chinese. Visual sensitivity corresponding to the 3 × 3-mm2 macular region was expressed in unlogged 1/lambert for investigation of the structure-function associations. Diagnostic performance was evaluated with area under the receiver operating characteristic curves (AUCs). The study was conducted between January 12, 2016, and December 12, 2016. Main Outcomes and Measures: Area under the receiver operating characteristic curve and R2 analysis. Results: Of the 115 patients with glaucoma, 42 (36.5%) were women (mean [SD] age, 53.5 [13.4] years); of the 35 individuals with healthy eyes, 25 (71.4%) were women (age, 60.6 [5.9] years). Inner macular vessel density and thickness were 4.3% (95% CI, 2.4%-6.1%) and 21.1 µm (95% CI, 17.4-24.9 µm) smaller, respectively, in eyes with glaucoma compared with healthy eyes. The AUC of mean inner macular thickness for glaucoma detection was greater than that of mean inner macular vessel density (difference, 0.17; 95% CI, 0.01-0.31; P = .03). At 90% specificity, the sensitivity of mean inner macular thicknesses for detection of glaucoma was greater than that of mean inner macular vessel densities (difference, 29.2%; 95% CI, 11.5%-64.6%; P = .02). The strength of the structure-function association was stronger for mean inner macular thickness than mean inner macular vessel density in the linear (difference in R2 = 0.38; 95% CI, 0.22-0.54; P < .001) and nonlinear (difference in R2 = 0.36; 95% CI, 0.21-0.51; P < .001) regression models. Conclusions and Relevance: In this study, OCT measurement of inner macular thickness shows a higher diagnostic performance to detect glaucoma and a stronger structure-function association than the currently used OCT-A measurement of inner macular vessel density. These findings may suggest that OCT-A of the macula has a limited role in the diagnostic evaluation of glaucoma.


Subject(s)
Fluorescein Angiography/methods , Glaucoma, Open-Angle/diagnosis , Retina/pathology , Retinal Vessels/diagnostic imaging , Tomography, Optical Coherence/methods , Adult , Aged , Area Under Curve , Cross-Sectional Studies , Female , Glaucoma, Open-Angle/physiopathology , Gonioscopy , Humans , Intraocular Pressure/physiology , Male , Middle Aged , Nerve Fibers/pathology , Organ Size , Retinal Ganglion Cells/pathology , Visual Acuity/physiology , Visual Field Tests , Visual Fields/physiology
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 1349-52, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26736518

ABSTRACT

Mechanical thrombectomy for ischemic stroke has high recanalization rate, long treatment time window and low hemorrhage risk. However, the clot engagement approach of caging the clot against the vessel wall can cause vessel stenosis and stroke recurrence. A device with reduced radial stenting force that reduces vessel wall friction would minimize stenosis and damage. The use of localized Radio Frequency (RF) to enable clot engagement and retrieval with minimal stenting force is explored in this study. New mechanical thrombectomy devices enabled with RF (Patent No.: US 62/172,043) were built and tested on human blood clots in vessels ex vivo. Test results showed that the RF-mechanical thrombectomy successfully and reproducibly captured and retrieved the clots without relying on stent caging of the clot against the vessel wall. Further work will be conducted on animals to compare vessel wall damage between conventional and RF-mechanical thrombectomy.


Subject(s)
Thrombectomy , Brain Ischemia , Humans , Stents , Stroke , Thrombosis , Treatment Outcome
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 1353-6, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26736519

ABSTRACT

Intravenous thrombolysis for the treatment of ischemic stroke requires long treatment time and high drug dosage which increases the risk of hemorrhage. Localized zonal dosage of urokinase between 100 - 500 International Units (IU), i.e., less than 5% of typical systemic dosage (60,000 - 120,000 IU) at the thrombus can shorten the treatment time to less than 30 minutes while reducing the risk of hemorrhage. The effect of zonal-delivered urokinase on the molecular changes in a 100 µm thick by 20 mm diameter blood clot was quantified using Raman spectroscopy. In situ Raman spectra showed that the fibrin concentration in the clot decreased with time. The results verified that a zonal-delivered urokinase can dissolve the clot and reduce the treatment time. Further trials on animals will be conducted to examine the potential of zonal-delivery to accelerate clot dissolution for ischemic stroke while minimizing the risk of hemorrhage.


Subject(s)
Spectrum Analysis, Raman , Brain Ischemia , Fibrinolytic Agents , Humans , Stroke , Thrombolytic Therapy , Urokinase-Type Plasminogen Activator
8.
Article in English | MEDLINE | ID: mdl-24109793

ABSTRACT

Filling aneurysms with embolization coils is a widely used part of the treatment to stop intracranial aneurysm from rupturing. However, the effect of coiling on aneurysmal pressure has not been established. In this study, the effect of intra-aneurysmal coiling on pressure reduction was characterized. Coil deployment in the aneurysm will disturb flow and may induce aneurysmal coagulation. These effects were experimentally examined in this study using silicone rubber saccular aneurysm models. Changes in aneurysmal blood pressure under pulsatile flow were characterized. With coils in the aneurysm, results showed that flow reduction of anti-coagulated blood in the aneurysm did not reduce aneurysmal pressure. Significant pressure reduction was observed only when the blood's coagulation ability is restored to normal. These results suggest that blood coagulation is pivotal to pressure reduction and concomitant with rupture risk reduction in treatments of aneurysm with coils.


Subject(s)
Anticoagulants/pharmacology , Blood Pressure/physiology , Blood Vessel Prosthesis , Cerebrovascular Circulation/drug effects , Embolization, Therapeutic , Intracranial Aneurysm/physiopathology , Intracranial Aneurysm/therapy , Pulsatile Flow/physiology , Blood Pressure/drug effects , Humans , Models, Biological
SELECTION OF CITATIONS
SEARCH DETAIL
...