Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Intern Med J ; 53(6): 1054-1057, 2023 06.
Article in English | MEDLINE | ID: mdl-37294020

ABSTRACT

Capnocytophaga canimorsus is a fastidious, capnophilic and facultative anaerobic Gram-negative rod found commonly in the oral flora of dogs that may cause zoonotic infections such as cellulitis and eye infections. In immunocompromised patients, it may cause fulminant sepsis. Meningitis due to C. canimorsus is, however, a rare manifestation. This is the first reported case of C. canimorsus meningitis in Australia in an immunocompetent veterinarian diagnosed by 16s ribosomal RNA polymerase chain reaction.


Subject(s)
Bites and Stings , Gram-Negative Bacterial Infections , Meningitis , Veterinarians , Humans , Animals , Dogs , RNA, Ribosomal, 16S/genetics , Capnocytophaga/genetics , Polymerase Chain Reaction , Gram-Negative Bacterial Infections/diagnosis , Bites and Stings/complications
2.
J Endovasc Ther ; : 15266028221114722, 2022 Jul 27.
Article in English | MEDLINE | ID: mdl-35898156

ABSTRACT

PURPOSE: Leg muscle microvascular blood flow (perfusion) is impaired in response to maximal exercise in patients with peripheral artery disease (PAD); however, during submaximal exercise, microvascular perfusion is maintained due to a greater increase in microvascular blood volume compared with that seen in healthy adults. It is unclear whether this submaximal exercise response reflects a microvascular impairment, or whether it is a compensatory response for the limited conduit artery flow in PAD. Therefore, to clarify the role of conduit artery blood flow, we compared whole-limb blood flow and skeletal muscle microvascular perfusion responses with exercise in patients with PAD (n=9; 60±7 years) prior to, and following, lower-limb endovascular revascularization. MATERIALS AND METHODS: Microvascular perfusion (microvascular volume × flow velocity) of the medial gastrocnemius muscle was measured before and immediately after a 5 minute bout of submaximal intermittent isometric plantar-flexion exercise using contrast-enhanced ultrasound imaging. Exercise contraction-by-contraction whole-leg blood flow and vascular conductance were measured using strain-gauge plethysmography. RESULTS: With revascularization there was a significant increase in whole-leg blood flow and conductance during exercise (p<0.05). Exercise-induced muscle microvascular perfusion response did not change with revascularization (pre-revascularization: 3.19±2.32; post-revascularization: 3.89±1.67 aU.s-1; p=0.38). However, the parameters that determine microvascular perfusion changed, with a reduction in the microvascular volume response to exercise (pre-revascularization: 6.76±3.56; post-revascularization: 2.42±0.69 aU; p<0.01) and an increase in microvascular flow velocity (pre-revascularization: 0.25±0.13; post-revascularization: 0.59±0.25 s-1; p=0.02). CONCLUSION: These findings suggest that patients with PAD compensate for the conduit artery blood flow impairment with an increase in microvascular blood volume to maintain muscle perfusion during submaximal exercise. CLINICAL IMPACT: The findings from this study support the notion that the impairment in conduit artery blood flow in patients with PAD leads to compensatory changes in microvascular blood volume and flow velocity to maintain muscle microvascular perfusion during submaximal leg exercise. Moreover, this study demonstrates that these microvascular changes are reversed and become normalized with successful lower-limb endovascular revascularization.

3.
Heart Lung Circ ; 30(11): 1726-1733, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34384703

ABSTRACT

BACKGROUND AND AIM: Contrast-enhanced ultrasound (CEUS) measures of post-occlusion skeletal muscle microvascular responsiveness demonstrate the microvascular dysfunction associated with ageing and age-related disease. However, the accessibility of CEUS is limited by the need for intravenous administration of ultrasound contrast agents and sophisticated imaging analysis. Alternative methods are required for the broader assessment of microvascular dysfunction in research and clinical settings. Therefore, we aimed to evaluate the level of association and agreement between CEUS and near-infrared spectroscopy (NIRS)-derived measures of post-occlusion skeletal muscle microvascular responsiveness in older adults. METHODS: During supine rest, participants (n=15, 67±11 years) underwent 5 minutes of thigh cuff-occlusion (200 mmHg). Post-occlusion CEUS measures of calf muscle microvascular responsiveness were made, including time to 95% peak acoustic intensity (TTP95 AI) and the rate of rise (slope AI). Simultaneous measures, including time to 95% peak oxygenated haemoglobin (TTP95 O2Hb) and slope O2Hb, were made using continuous-wave NIRS in the same muscle region. RESULTS: There were strong correlations between TTP95 measures derived from CEUS and NIRS (r=0.834, p=<0.001) and the corresponding measures of slope (r=0.735, p=0.004). The limits of agreement demonstrated by Bland Altman plot analyses for CEUS and NIRS-derived measures of TTP95 (-9.67-1.98 s) and slope (-1.29-5.23%. s-1) were smaller than the minimum differences expected in people with microvascular dysfunction. CONCLUSIONS: The strong correlations and level of agreement in the present study support the use of NIRS as a non-invasive, portable and cost-effective method for assessing post-occlusion skeletal muscle microvascular responsiveness in older adults.


Subject(s)
Spectroscopy, Near-Infrared , Vascular Diseases , Aged , Humans , Microcirculation , Muscle, Skeletal/diagnostic imaging , Ultrasonography
4.
Exp Physiol ; 105(12): 2238-2245, 2020 12.
Article in English | MEDLINE | ID: mdl-33017064

ABSTRACT

NEW FINDINGS: What is the central question of the study? Cuff-occlusion duration may influence contrast-enhanced ultrasound (CEUS) assessments of skeletal muscle microvascular blood flow responsiveness: what are the effects of 1, 3 and 5 min cuff-occlusion on the magnitude and reliability of calf muscle microvascular blood flow responsiveness in older adults? What is the main finding and its importance? Calf muscle microvascular blood flow responsiveness was enhanced following 5 min cuff-occlusion compared with 1 min. The reliability of post-occlusion CEUS measurements was also improved following 5 min occlusion. The use of a standardized 5 min occlusion period should therefore be considered in future studies and clinical practice. ABSTRACT: Contrast-enhanced ultrasound (CEUS) is increasingly used in assessments of skeletal muscle microvascular blood flow responsiveness. In response to limb cuff-occlusion, some studies have reported significant impairments in CEUS measurements of microvascular blood flow in older adults with cardiovascular or metabolic disease, whereas others have failed to detect significant between-group differences, which has brought the reliability of the technique into question. In the absence of a standardized CEUS protocol, there is variance in the duration of cuff-occlusion used, which is likely to influence post-occlusion measurements of muscle microvascular blood flow. We aimed to determine the effect of cuff-occlusion duration by comparing the magnitude and reliability of CEUS measurements of calf muscle microvascular blood flow responsiveness in older adults (n = 15, 67 ± 11 years) following 1, 3 and 5 min occlusion periods. Microvascular blood flow (= microvascular volume × microvascular velocity) within the calf muscle was measured using real-time destruction-replenishment CEUS. Measurements were made following thigh cuff-occlusion (200 mmHg) periods of 1, 3 and 5 min in a random order. Microvascular blood flow was higher following 3 min (3.71 ± 1.46 aU s-1 ) and 5 min (3.47 ± 1.48 aU s-1 ) compared with 1 min (2.42 ± 1.27 aU s-1 , P = 0.002), which corresponded with higher microvascular volumes after 3 and 5 min compared with 1 min. Reliability was good following 5 min (intraclass correlation coefficient (ICC) 0.49) compared with poor following 1 min (ICC 0.34) and 3 min (ICC 0.35). This study demonstrates that the magnitude and reliability of calf muscle microvascular responsiveness is enhanced using a 5 min cuff-occlusion protocol compared with 1 min in older adults.


Subject(s)
Microcirculation/physiology , Muscle, Skeletal/physiopathology , Regional Blood Flow/physiology , Aged , Blood Flow Velocity/physiology , Cardiovascular Diseases/physiopathology , Female , Humans , Male , Metabolic Diseases/physiopathology , Ultrasonography/methods
5.
Echocardiography ; 37(8): 1199-1204, 2020 08.
Article in English | MEDLINE | ID: mdl-32750205

ABSTRACT

BACKGROUD: Diastolic dysfunction (DD) is reported to affect up to 35% of the adult general population. The consequence of progressive DD is heart failure with preserved ejection fraction (HFpEF). Coronary microvascular dysfunction (CMD) has been suggested as one of the pathologic mechanisms leading to HFpEF. We investigated whether there was an association between coronary microvascular function and echocardiographic indices of left ventricular diastolic function at rest in patients with chest pain and unobstructed coronary arteries (CPUCA). METHODS: This retrospective observational study recruited patients referred to cardiology clinics assessment of chest pain who subsequently underwent assessment via CT coronary angiogram (CTA). Coronary microvascular dysfunction was determined by myocardial blood flow reserve (MBFR; <2.0) using myocardial contrast echocardiography. Echocardiographic indices of diastolic function (septal mitral annular e'; septal mitral annular E/e', E/A ratio) were measured from baseline transthoracic echocardiogram. RESULTS: 149 patients (52% men) with a mean age 59.7(9.5) years were recruited. Mean (standard deviation) MBFR was 2.2 (0.51). 37% (55/149) had MBFR < 2.0. Median [interquartile range] septal mitral annular e' velocity and septal mitral annular E/e' were 7.6 cm/s [6.2, 8.9] and 9.5 [7.5, 10.8], respectively. Univariate regression analysis showed only age was a significant predictor of increasing septal mitral annular E/e' (ß = +0.20 95% CI 0.13, +0.28, P < .001) but not MBFR. Multivariable analysis also showed no association between these septal mitral annular E/e' and MBFR after adjustment for cardiovascular risk factors. CONCLUSION: There was no relationship found between echocardiographic indices of left ventricular diastolic function and coronary microvascular function at rest.


Subject(s)
Heart Failure , Ventricular Dysfunction, Left , Adult , Chest Pain , Coronary Vessels/diagnostic imaging , Diastole , Female , Humans , Male , Middle Aged , Stroke Volume , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL