Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38445836

ABSTRACT

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Subject(s)
Brugada Syndrome , Defibrillators, Implantable , Pacemaker, Artificial , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Brugada Syndrome/therapy , Electrocardiography/methods , Electrocardiography, Ambulatory/methods , Adult
2.
Heart Fail Rev ; 29(2): 559-569, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38329583

ABSTRACT

The use of left ventricular assist devices (LVAD) has significantly increased in the last years, trying to offer a therapeutic alternative to heart transplantation, in light also to the significant heart donor shortage compared to the growing advanced heart failure population. Despite technological improvements in the devices, LVAD-related mortality is still fairly high, with right heart failure being one of the predominant predictors. Therefore, many efforts have been made toward a thorough right ventricular (RV) evaluation prior to LVAD implant, considering clinical, laboratory, echocardiographic, and invasive hemodynamic parameters. However, there is high heterogeneity regarding both which predictor is the strongest as well as the relative cut-off values, and a consensus has not been reached yet, increasing the risk of facing patients in which the distinction between good or poor RV function cannot be surely reached. In parallel, due to technological development and availability of mechanical circulatory support of the RV, LVADs are being considered even in patients with suboptimal RV function. The aim of our review is to analyze the current evidence regarding the role of RV function prior to LVAD and its evaluation, pointing out the extreme variability in parameters that are currently assessed and future prospective regarding new diagnostic tools. Finally, we attempt to gather the available information on the therapeutic strategies to use in the peri-operative phase, in order to reduce the incidence of RV failure, especially in patients in which the preoperative evaluation highlighted some conflicting results with regard to ventricular function.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Ventricular Dysfunction, Right , Humans , Heart-Assist Devices/adverse effects , Heart Failure/surgery , Heart Failure/etiology , Heart Transplantation/adverse effects , Echocardiography , Retrospective Studies
3.
J Clin Med ; 13(4)2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38398242

ABSTRACT

(1) Background: Reverse septal movement (RSM) often occurs after cardiac surgery, consisting of a paradoxical systolic movement of the interventricular septum. In this retrospective study, we aimed to investigate possible determinants of RSM after coronary artery bypass surgery (CABG). (2) Methods: Patients who underwent CABG with on- or off-pump techniques at our center from March 2019 to October 2021 were retrospectively included. Exclusion criteria were: exposure to combined procedures (e.g., valve implantation), prior cardiac surgery, intraventricular conduction delays, and previous pacemaker implantation. Laboratory tests and echocardiographic and cardiopulmonary bypass (CPB) duration data were collected. (3) Results: We enrolled 138 patients, of whom 32 (23.2%) underwent off-pump CABG. Approximately 89.1% of the population was male; the mean age was 70 ± 11 years. There was no difference in RSM incidence in patients undergoing the off-pump and on-pump techniques (71.9% vs. 62.3%; p = 0.319). In patients undergoing on-pump surgery, the incidence of RSM was slightly higher in longer CPB procedures (OR 1.02 (1.00-1.03) p = 0.012), and clamping aortic time was also greater (OR 1.02 (1.00-1.03) p = 0.042). (4) Conclusions: CPB length seems to be correlated with a higher RSM appearance. This better knowledge of RSM reinforces the safety of CABG and its neutral effect on global biventricular function.

5.
Article in English | MEDLINE | ID: mdl-38206450

ABSTRACT

BACKGROUND: Mitral isthmus (MI) conduction block is a fundamental step in anatomical approach treatment for persistent atrial fibrillation (PeAF). However, MI block is hardly achievable with endocardial ablation only. Retrograde ethanol infusion (EI) into the vein of Marshall (VOM) facilitates MI block. Fluorographic myocardial staining (MS) during VOM-EI could be helpful in predicting procedural alcoholization outcome even if its role is qualitatively assessed in the routine. The aim was to quantitatively assess MS during VOM-EI and to evaluate its association with MI block achievement. METHODS: Consecutive patients undergoing catheter ablation for PeAF at Fondazione Toscana Gabriele Monasterio (Pisa, Italy) from February 2022 to May 2023 were considered. Patients with identifiable VOM were included. A proposed index of MS (MSI) was retrospectively calculated in each included patient. Correlation of MSI with low-voltage zones (LVZ) extension after VOM-EI and its association with MI block achievement were assessed. RESULTS: In total, 42 patients out of 49 (85.8%) had an identifiable VOM. MI block was successfully achieved in 35 patients out of 42 (83.3%). MSI was significantly associated with the occurrence of MI block (OR 1.24 (1.03-1.48); p = 0.022). A higher MSI resulted in reduced ablation time (p = 0.014) and reduced radiofrequency applications (p = 0.002) to obtain MI block. MSI was also associated with MI block obtained by endocardial ablation only (OR 1.07 (1.02-1.13); p = 0.002). MSI was highly correlated with newly formed LVZ extension (r = 0.776; p = 0.001). CONCLUSIONS: In our study cohort, optimal MSI predicts MI block and facilitates its achievement with endocardial ablation only.

6.
Minerva Cardiol Angiol ; 72(1): 87-94, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37405712

ABSTRACT

BACKGROUND: Even if prevalent among patients with severe aortic stenosis (AS), the clinical suspicion for transthyretin cardiac amyloidosis (ATTR-CA) remains difficult in this subset. We report our single center experience on ATTR-CA detection among TAVR candidates to provide insights on the prevalence and clinical features of dual pathology as compared to lone AS. METHODS: Consecutive severe AS patients undergoing transcatheter aortic valve replacement (TAVR) evaluation at a single center were prospectively included. Those with suspected ATTR-CA based on clinical assessment underwent 99m Tc-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) bone scintigraphy. The RAISE score, a novel screening tool with high sensitivity for ATTR-CA in AS, was retrospectively calculated to rule-out ATTR-CA in the remaining patients. Patients were categorized as follow: "ATTR-CA+": patients with confirmed ATTR-CA at DPD bone scintigraphy; "ATTR-CA-": patients with negative DPD bone scintigraphy or a negative RAISE score; "ATTR-CA indeterminate": patients not undergoing ATTR-CA assessment with a positive RAISE score. The characteristics of ATTR-CA+ and ATTR-CA- patients were compared. RESULTS: Of 107 included patients, ATTR-CA suspicion was posed in 13 patients and confirmed in six. Patients were categorized as follow: 6 (5.6%) ATTR-CA+, 79 (73.8%) ATTR-CA-, 22 (20.6%) ATTR-CA indeterminate. Excluding ATTR-CA indeterminate patients, the prevalence of ATTR-CA was 7.1% (95% CI 2.6-14.7%). As compared to ATTR-CA - patients, ATTR-CA + patients were older, had higher procedural risk and more extensive myocardial and renal damage. They had higher left ventricle mass index and lower ECG voltages, translating into a lower voltage to mass ratio. Moreover, we describe for the first time bifascicular block as an ECG feature highly specific of patients with dual pathology (50.0% vs. 2.7%, P<0.001). Of note, pericardial effusion was rarely found in patients with lone AS (16.7% vs. 1.2%, P=0.027). No difference in procedural outcomes was observed between groups. CONCLUSIONS: Among severe AS patients, ATTR-CA is prevalent and presents with phenotypic features that may aid to differentiate it from lone AS. A clinical approach based on routine search of amyloidosis features might lead to selective DPD bone scintigraphy with a satisfactory positive predictive value.


Subject(s)
Amyloid Neuropathies, Familial , Aortic Valve Stenosis , Cardiomyopathies , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Prealbumin , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/epidemiology , Cardiomyopathies/surgery , Amyloid Neuropathies, Familial/complications , Amyloid Neuropathies, Familial/epidemiology , Amyloid Neuropathies, Familial/surgery , Retrospective Studies , Tomography, X-Ray Computed , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/surgery
8.
J Clin Med ; 12(21)2023 Nov 03.
Article in English | MEDLINE | ID: mdl-37959380

ABSTRACT

BACKGROUND: The best ablation treatment for persistent atrial fibrillation (PeAF) patients is still debated. The vein of Marshall (VOM) seems to be a promising target for ablation and could be combined with a linear set of ablation lesions. The aim of our study is to evaluate the incidence of AF recurrences in a PeAF population treated with a comprehensive ablation approach consisting of VOM ethanol infusion (EI), pulmonary vein isolation (PVI), a left atrial (LA) roofline, a mitral line (guided by the newly formed lesion after alcohol infusion into the VOM and validated by pacing), and a cavotricuspid isthmus line. METHODS: Consecutive patients undergoing the first ablation procedure of catheter ablation (CA) for PeAF were enrolled. All patients underwent VOM-EI, PVI, and ablation lines along the roof of the LA, mitral, and cavotricuspid isthmus. LA voltage mapping before and after VOM-EI was also performed. An implantable loop recorder (ILR) was implanted at the end of the ablation in each patient. RESULTS: Thirty-one consecutive patients (66 ± 8 years and 71% male) affected by PeAF were included in this study. The VOM-EI procedural phase lasted 21.4 ± 10.1 min. PV isolation and lines were validated in all subjects. The ML block was achieved within 10.8 ± 8.7 min. At a mean follow-up of 12 ± 7 months, 27 out of 31 (87%) patients remained free from AT/AF recurrences. Among the patients with recurrences, two (50%) had incomplete ablation lesions and three (75%) had "suboptimal" VOM-EI. In 23/31 patients (74%), antiarrhythmic drugs (AADs) were discontinued after 1 month of follow-up. No significant complications were reported during the follow-up. CONCLUSIONS: this single-center experience demonstrates that VOM-EI systematically combined with an anatomical ablation set in patients with PeAF resulted in feasible, safe, and effective freedom from AF/AT recurrences in 87% of the population after a 1-year follow-up period according to an ILR.

10.
Front Cardiovasc Med ; 10: 1282064, 2023.
Article in English | MEDLINE | ID: mdl-37767371

ABSTRACT

In this editorial we summarize the most viewed and downloaded contributing articles to the Research Topic "Case Reports in Heart Failure and Transplantation: 2022" of the journal Frontiers in Cardiovascular Medicine.

11.
Diagnostics (Basel) ; 13(16)2023 Aug 08.
Article in English | MEDLINE | ID: mdl-37627879

ABSTRACT

BACKGROUND: The hemodynamic definition of PH has recently been revised with unchanged threshold of peak tricuspid regurgitation velocity (TRV). The aim of this study was to evaluate the predictive accuracy of peak TRV for PH based on the new (>20 mmHg) and the old (>25 mmHg) cut-off value for mean pulmonary artery pressure (mPAP) and to compare it with the mean right ventricular-right atrial (RV-RA) pressure gradient. METHODS: Patients with advanced heart failure were screened from 2016 to 2021. The exclusion criteria were absent right heart catheterization (RHC) results, chronic obstructive pulmonary disease, any septal defect, inadequate acoustic window or undetectable TR. The mean RV-RA gradient was calculated from the velocity-time integral of TR. RESULTS: The study included 41 patients; 34 (82.9%) had mPAP > 20 mmHg and 24 (58.5%) had mPAP > 25 mmHg. The AUC for the prediction of PH with mPAP > 20 mmHg was 0.855 for peak TRV and mean RV-RA gradient was 0.811. AUC for the prediction of PH defined as mPAP > 25 mmHg for peak TRV was 0.860 and for mean RV-RA gradient was 0.830. A cutoff value of 2.4 m/s for peak TRV had 65% sensitivity and 100% positive predictive value for predicting PH according to the new definition. CONCLUSIONS: Peak TRV performed better than mean RV-RA pressure gradient in predicting PH irrespective of hemodynamic definitions. Peak TRV performed similarly with the two definitions of PH, but a lower cutoff value had higher sensitivity and equal positive predictive value for PH.

12.
Eur Heart J Cardiovasc Imaging ; 25(1): 105-115, 2023 Dec 21.
Article in English | MEDLINE | ID: mdl-37542478

ABSTRACT

AIMS: Right heart failure (RHF) after left ventricular assist device (LVAD) implant is burdened by high morbidity and mortality rates and should be prevented by appropriate patient selection. Adequate right ventricular function is of paramount importance but its assessment is complex and cannot disregard afterload. Myocardial work (MW) is a non-invasive Speckle Tracking Echocardiography-derived method to estimate pressure-volume loops. The aim of this study was to evaluate the performance of right ventricular myocardial work to predict RHF and long-term mortality after LVAD implant. METHODS AND RESULTS: Consecutive patients from May 2017 to February 2022 undergoing LVAD implant were retrospectively reviewed. Patients without a useful echocardiographic exam prior to LVAD implant were excluded. MW analysis was performed. The primary endpoints were early RHF (<30 days from LVAD implant) and death at latest available follow-up. We included 23 patients (mean age 64 ± 8 years, 91% men). Median follow-up was 339 days (IQR: 30-1143). Early RHF occurred in six patients (26%). A lower right ventricular global work efficiency [RVGWE, OR 0.86, 95% confidence intervals (CI) 0.76-0.97, P = 0.014] was associated with the occurrence of early RHF. Among MW indices, the performance for early RHF prediction was greatest for RVGWE [area under the curve (AUC) 0.92] and a cut-off of 77% had a 100% sensitivity and 82% specificity. At long-term follow-up, death occurred in 4 of 14 patients (28.6%) in the RVGWE > 77% group and in 6 of 9 patients (66.7%) in the RVGWE < 77% group (HR 0.25, 95% CI 0.07-0.90, P = 0.033). CONCLUSION: RVGWE was a predictor of early RHF after LVAD implant and brought prognostic value in terms of long-term mortality.


Subject(s)
Heart Failure , Heart-Assist Devices , Ventricular Dysfunction, Right , Male , Humans , Middle Aged , Aged , Female , Retrospective Studies , Heart Failure/diagnostic imaging , Heart Failure/therapy , Heart Failure/epidemiology , Prognosis , Echocardiography , Ventricular Dysfunction, Right/diagnostic imaging
13.
ESC Heart Fail ; 10(5): 2853-2864, 2023 10.
Article in English | MEDLINE | ID: mdl-37415291

ABSTRACT

AIMS: The presence of anti-human leucocyte antigen (HLA) antibodies has been implicated in a higher incidence of complications as well as mortality rate in heart transplantation. The aim of the study was to identify through non-invasive parameters early signs of myocardial dysfunction in the presence of anti-HLA antibodies but without evidence of antibody-mediated rejection (AMR) and its possible prognostic impact. METHODS AND RESULTS: A total of 113 heart-transplanted patients without acute cellular rejection (ACR) and AMR or cardiac allograft vasculopathy (CAV) were prospectively enrolled and divided into two groups ['HLA+' (50 patients) and 'HLA-' (63 patients)], based on the presence of anti-HLA antibodies. Each patient was followed for 2 years after the enrolment, recording episodes of AMR, ACR, CAV, and mortality. Clinical characteristics were similar between the two groups. Among laboratory data, N-terminal pro-B-type natriuretic peptide and high-sensitivity cardiac troponin values were significantly higher in the presence of anti-HLA antibodies (P < 0.001 and P = 0.003, respectively). The echocardiographic parameters that showed a statistically significant difference between the two groups were deceleration time of E wave (DecT E, P < 0.001), left ventricular global longitudinal strain (P < 0.001), tricuspid annular plane systolic excursion (P = 0.011), tricuspid S' wave (P = 0.002), and free wall right ventricular longitudinal strain (fwRVLS, P = 0.027), whereas left atrial strain did not differ significantly (P = 0.408). Univariate analysis showed that anti-HLA antibodies were associated with the development of CAV at both 1 and 2 year follow-up [odds ratio (OR) 11.90, 95% confidence interval (CI) 1.43-90.79, P = 0.022 and OR 3.37, 95% CI 1.78-9.67, P = 0.024, respectively]. Bivariate analysis demonstrated that both fwRVLS and DecT E were predictors of CAV development independently from HLA status. CONCLUSIONS: The presence of circulating anti-HLA antibodies is correlated with a mild cardiac dysfunction, even in the absence of AMR, and CAV development. Interestingly, reduced values of DecT E and fwRVLS were predictors of future development of CAV, independently from anti-HLA antibody.


Subject(s)
Heart Transplantation , Humans , Heart Transplantation/adverse effects , Heart Transplantation/methods , Antibodies , Prognosis , Graft Rejection/diagnosis , Echocardiography
14.
ESC Heart Fail ; 10(4): 2607-2620, 2023 08.
Article in English | MEDLINE | ID: mdl-37345220

ABSTRACT

AIMS: Mechanical circulatory support (MCS) systems are increasingly employed in cardiogenic shock and advanced heart failure. A thorough understanding of the complex interactions occurring among heart, vasculature, and device is essential to optimize patient's management. The aim of this study is to explore non-invasive haemodynamic profiling of patients undergoing MCS based on pressure-strain (PS) analysis. METHODS: Clinical and echocardiographic data from consecutive patients undergoing different MCS systems positioning/implantation admitted to the third level cardiological intensive care unit of Siena Hospital from August 2021 to November 2021 were retrospectively reviewed. Patients without a useful echocardiographic exam or without arterial blood pressure recording at the time of echocardiography were excluded. Myocardial work analysis was performed in the included patients. RESULTS: We reviewed 18 patients, of which nine were excluded. Included patients were three patients with intra-aortic balloon pump (IABP), two patients with durable left ventricular assist device (dLVAD), two patients with Impella®, one patient with extracorporeal membrane oxygenation (ECMO), and one patient with ECMO and IABP. Myocardial work analysis was feasible in each included patient. The use of IABP shifted the PS curve rightward and downward. Global work index (GWI) and global wasted work (GWW) decreased after IABP positioning, whereas global work efficiency (GWE) increased. The use of continuous-flow pumps, whether temporaneous (Impella®) or long term (dLVAD), induced a change in the PS loop morphology, with a shift towards a triangular shape. ECMO positioning alone resulted in a narrowing of the PS loop, with a decrease in GWI and GWE and an increase in GWW and mean arterial pressure. The combined used of IABP with ECMO widened the PS loop and improved GWI and GWE. CONCLUSIONS: PS loops analysis in patients undergoing MCS seems to be feasible and may unveil MCS-induced haemodynamic variations. Myocardial work could be used to monitor ventricular-arterial-device coupling and guide tailored MCS management.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Retrospective Studies , Shock, Cardiogenic/therapy , Heart Failure/therapy , Hemodynamics
15.
J Clin Med ; 12(10)2023 May 16.
Article in English | MEDLINE | ID: mdl-37240611

ABSTRACT

Background: The gold-standard treatment for end-stage heart failure is heart transplantation, but the lack of organ donors remains an important limitation in this field. An accurate selection of marginal hearts is fundamental to increase organ availability. Purpose: In our study we analyzed if recipients receiving marginal donor (MD) hearts, selected by dipyridamole stress echocardiography according to the ADOHERS national protocol, had different outcomes compared to recipients with acceptable donor (AD) hearts. Methods: Data were collected and retrospectively analyzed from patients who received an orthotopic heart transplant at our institution between 2006 and 2014. Dipyridamole stress echo was performed on identified marginal donors and selected hearts were eventually transplanted. Clinical, laboratory and instrumental features of the recipients were evaluated and patients with homogenous baseline characteristics were selected. Results: Eleven recipients transplanted with a selected marginal heart and eleven recipients transplanted with an acceptable heart were included. Mean donor age was 41 ± 23. The median follow-up was 113 months (IQR 86-146 months). Age, cardiovascular risk and morpho-functional characteristics of the left ventricle were comparable between the two populations (p > 0.05). Left atrial size was significantly higher in patients with marginal hearts (acceptable atrial volume: 23 ± 5 mL; marginal atrial volume: 38 ± 5 mL; p = 0.003). Acceptable donor recipients showed a higher impact of Cardiac Allograph Vasculopathy (p = 0.019). No rejection differences were found between the two groups. Four patients deceased, three were standard donor recipients and one was from the marginal donor group. Conclusions: Our study shows how cardiac transplant (Htx) from selected marginal donor hearts through a non-invasive bedside technique can alleviate the shortage of organs without a difference in survival compared to acceptable donor hearts.

16.
J Cardiovasc Dev Dis ; 10(4)2023 Apr 06.
Article in English | MEDLINE | ID: mdl-37103038

ABSTRACT

The moderator band (MB) is an intracavitary structure of the right ventricle composed of muscular fibers encompassing specialized Purkinje fibers, separated each other by collagen and adipose tissue. In the last decades, premature ventricular complexes originating within the Purkinje network have been implicated in the genesis of life-threatening arrhythmias. However, right Purkinje network arrhythmias have been much less reported in the literature compared to the left counterpart. The MB has unique anatomical and electrophysiological properties, which may account for its arrhythmogenicity and may be responsible for a significant portion of idiopathic ventricular fibrillation. MB embodies autonomic nervous system cells, with important implications in arrhythmogenesis. Some idiopathic ventricular arrhythmias, defined as the absence of any identifiable structural heart disorder, can begin from this site. Due to these complex structural and functional peculiarities strictly interplayed each other, it is arduous to determine the precise mechanism underlying MB arrhythmias. MB-related arrhythmias should be differentiated from other right Purkinje fibers arrhythmias because of the opportunity for intervention and the unusual site for the ablation poorly described in the literature. In the current paper, we report the characteristics and electrical properties of the MB, their involvement in arrhythmogenesis, clinical and electrophysiological peculiarities of MB-related arrhythmias, and current treatment options.

17.
J Cardiovasc Dev Dis ; 10(4)2023 Apr 14.
Article in English | MEDLINE | ID: mdl-37103048

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) is usually performed with biventricular pacing (BiVP), but recently, conduction system pacing (CSP) has been proposed as an alternative in case of BiVP failure. The aim of this study is to define an algorithm to choose between BiVP and CSP resynchronization using the interventricular conduction delays (IVCD) as a guide. METHODS: Consecutive patients from January 2018 to December 2020 with an indication for CRT were prospectively enrolled in the study group (delays-guided resynchronization group, DRG). A treatment algorithm based on IVCD was used to decide whether to leave the left ventricular (LV) lead to perform BiVP or pull it out and perform CSP. Outcomes from the DRG group were compared to a historical cohort of CRT patients who underwent CRT procedures between January 2016 and December 2017 (resynchronization standard guide group, SRG). The primary endpoint was a composite of cardiovascular mortality, heart failure (HF) hospitalization, or HF event at 1 year after the date of intervention. RESULTS: The study population consisted of 292 patients, of which 160 (54.8%) were in the DRG and 132 (45.2%) in the SRG. In the DRG, 41 of 160 patients underwent CSP based on the treatment algorithm (25.6%). The primary endpoint was significantly higher in the SRG (48/132, 36.4%) compared to the DRG (35/160, 21.8%) (hazard ratio (HR): 1.72; 95% confidence interval (CI): 1.12-2.65; p = 0.013). CONCLUSIONS: A treatment algorithm based on IVCD shifted one patient out of every four from BiVP to CSP, with consequent reduction in the primary endpoint after implantation. Therefore, its application could be useful to determine whether to perform BiVP or CSP.

18.
Eur Heart J Cardiovasc Imaging ; 24(8): 1052-1061, 2023 07 24.
Article in English | MEDLINE | ID: mdl-36752044

ABSTRACT

AIMS: The prognostic impact of flow trajectories according to stroke volume index (SVi) and transvalvular flow rate (FR) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) remains poorly assessed. We evaluated and compared SVi and FR prior and after TAVR for severe AS. METHODS AND RESULTS: Patients were categorized according to SVi (<35 mL/m2) and FR (<200 mL/s). The association of pre- and post-TAVR SVi and FR with all-cause mortality up to 3 years was assessed with multivariable Cox regression models. Among 980 patients with pre-TAVR flow assessment, SVi was reduced in 41.3% and FR in 48.1%. Baseline flow status was not an independent mortality predictor [SVi: hazard ratio (HR) 1.22, 95% confidence interval (CI) 0.85-1.82, FR: HR 0.78, 95% CI 0.48-1.27]. Among 731 patients undergoing early (5 days, interquartile range 2-29) post-TAVR flow assessment, SVi recovered in 40.1% and FR in 49.0% patients with baseline low flow. Reduced FR following TAVR was an independent predictor of mortality (HR 1.67, 95% CI 1.02-2.74), whereas SVi was not (HR 0.97, 95% CI 0.53-1.78). Three-year estimated mortality in patients with recovered FR was lower than that in patients with reduced FR (13.3 vs. 37.7% vs, P = 0.003) and similar to that in patients with normal baseline FR (P = 0.317). CONCLUSION: Baseline flow status was not an independent predictor of mid-term mortality among all-comers with severe AS undergoing TAVR. Flow recovery early after TAVR was frequent. Post-TAVR FR, but not SVi, was independently associated with mid-term all-cause mortality. By impacting flow status, AV replacement modifies the association of flow status with outcomes.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Stroke Volume , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors , Retrospective Studies , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Severity of Illness Index
19.
JACC Case Rep ; 4(22): 1480-1483, 2022 Nov 16.
Article in English | MEDLINE | ID: mdl-36444191

ABSTRACT

Here we present a case of an asymptomatic patient with a giant coronary artery aneurysm developed in the context of diffuse coronary artery ectasia. Giant coronary artery aneurysm was complicated by the presence of a large thrombus. The heart team settled for surgical treatment of the lesion. (Level of Difficulty: Intermediate.).

20.
Front Cardiovasc Med ; 9: 946540, 2022.
Article in English | MEDLINE | ID: mdl-36324748

ABSTRACT

Objectives: This study aimed to explore the correlation between left ventricular (LV) myocardial work (MW) indices and invasively-derived LV stroke work index (SWI) in a cohort of patients with advanced heart failure (AHF) considered for heart transplantation. Background: Left ventricular MW has emerged as a promising tool for diagnostic and prognostic purposes in heart failure (HF) but its relationship with hemodynamic data derived from right heart catheterization (RHC) has not been assessed in patients with advanced heart failure yet. Materials and methods: Consecutive patients with AHF considered for heart transplantation from 2016 to 2021 performing RHC and echocardiography as part of the workup were included. Conventional LV functional parameters and LV MW indices, including LV global work index (GWI), LV global constructive work (GCW), LV global wasted work (GWW), LV global work efficiency (GWE), and other were calculated and compared with invasively-measured LV SWI. Results: The population included 44 patients. Median time between RHC and echocardiography was 0 days (IQR: 0-24). Median age was 60 years (IQR: 54-63). For the most part, etiology of HF was non-ischemic (61.4%) and all patients were either on class NYHA II (61.4%) or III (27.3%). Median left ventricular ejection fraction was 25% (IQR: 22.3-32.3), median NT-proBNP 1,377 pg/ml (IQR: 646-2570). LV global longitudinal strain (GLS) significantly correlated with LV SWI (r = -0.337; p = 0.031), whereas, LV ejection fraction (EF) did not (r = 0.308; p = 0.050). With regard to LV MW indices, some of them demonstrated correlation with LV SWI, particularly LV GWI (r = 0.425; p = 0.006), LV GCW (r = 0.506; p = 0.001), LV global positive work (LV GPW; r = 0.464; p = 0.003) and LV global systolic constructive work (GSCW; r = 0.471; p = 0.002). Conclusion: Among LV MW indices, LV GCW correlated better with invasively-derived SWI, potentially representing a powerful tool for a more comprehensive evaluation of myocardial function.

SELECTION OF CITATIONS
SEARCH DETAIL
...