Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Health Sci Rep ; 6(10): e1626, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37829504

ABSTRACT

Background/Aim: To identify correlations between urodynamic study (UDS) findings and urinary symptoms in children with refractory monosymptomatic and nonmonosymptomatic primary nocturnal enuresis. Materials and Methods: A total of 96 neurologically normal children were enrolled, 44 consecutive boys and 51 consecutive girls, aged 5-18 years, of whom 41 (38.8%) had refractory monosymptomatic nocturnal enuresis (MNE) and 55 (61.2%) had refractory non-MNE (NMNE). We assessed the urodynamics of all children to detect any underlying bladder overactivity. A comparative analysis was carried out between the two groups of patients. Results: Detrusor overactivity (DO), low bladder capacity, low compliance, and increased postvoid residual (PVR) were identified in 70 (72.9%), 35 (36.5%), 43, and 76 (79.2%) patients, respectively. The mean bladder compliance was 21.66 ± 14.52 mL/cmH2O (2-75 cmH2O). Of the NMNE patients, 50 (90.9%) had abnormal urodynamic findings, while 40 (97.5%) had abnormal urodynamic findings in the MNE group. There was a statistically significant relationship between NMNE and both increased PVR and abnormal voiding patterns. Both high PVR and DO were significantly associated with obstructive urinary symptoms. Constipation and history of urinary tract infection (UTI) did not significantly correlate with UDS abnormality (p = 1.0 and p = 0.49, respectively). Conclusion: There was a high prevalence of bladder function disorders in both refractory MNE and NMNE patients in our study. This included small functional capacity, low bladder compliance, and marked DO. A nocturnal enuresis may be the only presenting symptom, however, it may be associated with bladder overactivity, UTI, and constipation; the UDS findings may aid in guiding the assessment and treatment of children suffering from primary refractory nocturnal enuresis and its association with bladder and bowel symptoms.

2.
Arch Acad Emerg Med ; 11(1): e62, 2023.
Article in English | MEDLINE | ID: mdl-37840871

ABSTRACT

Introduction: In spite of the results of previous studies regarding the benefits of ultrasonography for diagnosis of elbow fractures in children, the exact accuracy of this imaging modality is still under debate. Therefore, in this diagnostic systematic review and meta-analysis, we aimed to investigate the accuracy of ultrasonography in this regard. Methods: Two independent reviewers performed systematic search in Web of Science, Embase, PubMed, Cochrane, and Scopus for studies published from inception of these databases to May 2023. Quality assessment of the included studies was performed using Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2). Meta-Disc software version 1.4 and Stata statistical software package version 17.0 were used for statistical analysis. Results: A total of 648 studies with 1000 patients were included in the meta-analysis. The pooled sensitivity and specificity were 0.95 (95% CI: 0.93-0.97) and 0.87 (95% CI: 0.84-0.90), respectively. Pooled positive likelihood ratio (PLR) was 6.71 (95% CI: 3.86-11.67), negative likelihood ratio (NLR) was 0.09 (95% CI: 0.03-0.22), and pooled diagnostic odds ratio (DOR) of ultrasonography in detection of elbow fracture in children was 89.85 (95% CI: 31.56-255.8). The area under the summary receiver operating characteristic (ROC) curve for accuracy of ultrasonography in this regard was 0.93. Egger's and Begg's analyses showed that there is no significant publication bias (P=0.11 and P=0.29, respectively). Conclusion: Our meta-analysis revealed that ultrasonography is a relatively promising diagnostic imaging modality for identification of elbow fractures in children. However, clinicians employing ultrasonography for diagnosis of elbow fractures should be aware that studies included in this meta-analysis had limitations regarding methodological quality and are subject to risk of bias. Future high-quality studies with standardization of ultrasonography examination protocol are required to thoroughly validate ultrasonography for elbow fractures.

SELECTION OF CITATIONS
SEARCH DETAIL
...