1.
Phys Med ; 76: 16-27, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32569953

ABSTRACT

PURPOSE: To validate the accuracy of 4D Monte Carlo (4DMC) simulations to calculate dose deliveries to a deforming anatomy in the presence of realistic respiratory motion traces. A previously developed deformable lung phantom comprising an elastic tumor was modified to enable programming of arbitrary motion profiles. 4D simulations of the dose delivered to the phantom were compared with the measurements. METHODS: The deformable lung phantom moving with irregular breathing patterns was irradiated using static and VMAT beam deliveries. Using the RADPOS 4D dosimetry system, point doses were measured inside and outside the tumor. Dose profiles were acquired using films along the motion path of the tumor (S-I). In addition to dose measurements, RADPOS was used to record the motion of the tumor during dose deliveries. Dose measurements were then compared against 4DMC simulations with EGSnrc/4DdefDOSXYZnrc using the recorded tumor motion. RESULTS: The agreements between dose profiles from measurements and simulations were determined to be within 2%/2 mm. Point dose agreements were within 2σ of experimental and/or positional/dose reading uncertainties. 4DMC simulations were shown to accurately predict the sensitivity of delivered dose to the starting phase of breathing motions. We have demonstrated that our 4DMC method, combined with RADPOS, can accurately simulate realistic dose deliveries to a deforming anatomy moving with realistic breathing traces. This 4DMC tool has the potential to be used as a quality assurance tool to verify treatments involving respiratory motion. Adaptive treatment delivery is another area that may benefit from the potential of this 4DMC tool.


Subject(s)
Lung Neoplasms , Radiometry , Humans , Lung/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Monte Carlo Method , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Respiration
2.
Phys Med ; 69: 212-222, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31918373

ABSTRACT

PURPOSE: To measure the combined errors due to geometric inaccuracy and image co-registration on secondary images (dynamic CT angiography (dCTA), 3D DynaCT angiography (DynaCTA), and magnetic resonance images (MRI)) that are routinely used to aid in target delineation and planning for stereotactic radiosurgery (SRS). METHODS: Three phantoms (one commercial and two in-house built) and two different analysis approaches (commercial and MATLAB based) were used to quantify the magnitude of geometric image distortion and co-registration errors for different imaging modalities within CyberKnife's MultiPlan treatment planning software. For each phantom, the combined errors were reported as a mean target registration error (TRE). The mean TRE's for different intramodality imaging parameters (e.g., mAs, kVp, and phantom set-ups) and for dCTA, DynaCTA, and MRI systems were measured. RESULTS: Only X-ray based imaging can be performed with the commercial phantom, and the mean TRE ± standard deviation values were large compared to the in-house analysis using MATLAB. With the 3D printed phantom, even drastic changes in treatment planning CT imaging protocols did not greatly influence the mean TRE (<0.5 mm for a 1 mm slice thickness CT). For all imaging modalities, the largest mean TRE was found on DynaCT, followed by T2-weighted MR images (albeit all <1 mm). CONCLUSIONS: The user may overestimate the mean TRE if the commercial phantom and MultiPlan were used solely. The 3D printed phantom design is a sensitive and suitable quality assurance tool for measuring 3D geometric inaccuracy and co-registration errors across all imaging modalities.


Subject(s)
Magnetic Resonance Imaging , Radiosurgery , Radiotherapy Planning, Computer-Assisted/methods , Robotic Surgical Procedures , Tomography, X-Ray Computed , Computer Simulation , Humans , Imaging, Three-Dimensional , Phantoms, Imaging , Quality Assurance, Health Care , Reproducibility of Results , Software , X-Rays
3.
Phys Med ; 51: 81-90, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29776740

ABSTRACT

PURPOSE: To verify the accuracy of 4D Monte Carlo (MC) simulations, using the 4DdefDOSXYZnrc user code, in a deforming anatomy. We developed a tissue-equivalent and reproducible deformable lung phantom and evaluated 4D simulations of delivered dose to the phantom by comparing calculations against measurements. METHODS: A novel deformable phantom consisting of flexible foam, emulating lung tissue, inside a Lucite external body was constructed. A removable plug, containing an elastic tumor that can hold film and other dosimeters, was inserted in the phantom. Point dose and position measurements were performed inside and outside the tumor using RADPOS 4D dosimetry system. The phantom was irradiated on an Elekta Infinity linac in both stationary and moving states. The dose delivery was simulated using delivery log files and the phantom motion recorded with RADPOS. RESULTS: Reproducibility of the phantom motion was determined to be within 1 mm. The phantom motion presented realistic features like hysteresis. MC calculations and measurements agreed within 2% at the center of tumor. Outside the tumor agreements were better than 5% which were within the positional/dose reading uncertainties at the measurement points. More than 94% of dose points from MC simulations agreed within 2%/2 mm compared to film measurements. CONCLUSION: The deformable lung phantom presented realistic and reproducible motion characteristics and its use for verification of 4D dose calculations was demonstrated. Our 4DMC method is capable of accurate calculations of the realistic dose delivered to a moving and deforming anatomy during static and dynamic beam delivery techniques.


Subject(s)
Four-Dimensional Computed Tomography/instrumentation , Monte Carlo Method , Phantoms, Imaging , Lung/anatomy & histology , Lung/diagnostic imaging , Lung/physiology , Radiation Dosage , Respiration