Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 249
Filter
1.
Clin J Sport Med ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38975888

ABSTRACT

OBJECTIVE: COVID-19 has been associated with myocardial involvement in collegiate athletes. The first report from the Big Ten COVID-19 Cardiac Registry (Registry) was an ecological study that reported myocarditis in 37 of 1597 athletes (2.3%) based on local clinical diagnosis. Our objective was to assess the relationship between athlete and clinical characteristics and myocardial involvement. DESIGN: Cross-sectional study. SETTING: We analyzed data from 1218 COVID-19 positive Big Ten collegiate athletes who provided informed consent to participate in the Registry. PARTICIPANTS: 1218 athletes with a COVID-19-positive PCR test before June 1, 2021. ASSESSMENT OF INDEPENDENT VARIABLES: Demographic and clinical characteristics of athletes were obtained from the medical record. MAIN OUTCOME MEASURES: Myocardial involvement was diagnosed based on local clinical, cardiac magnetic resonance (CMR), electrocardiography, troponin assay, and echocardiography. We assessed the association of clinical factors with myocardial involvement using logistic regression and estimated the area under the receiver operating characteristic (ROC) curve. RESULTS: 25 of 1218 (2.0%) athletes met criteria for myocardial involvement. The logistic regression model used to predict myocardial involvement contained indicator variables for chest pain, new exercise intolerance, abnormal echocardiogram (echo), and abnormal troponin. The area under the ROC curve for these indicators was 0.714. The presence of any of these 4 factors in a collegiate athlete who tested positive for COVID-19 would capture 55.6% of cases. Among noncases without missing data, 86.9% would not be flagged for possible myocardial involvement. CONCLUSION: Myocardial involvement was infrequent. We predicted case status with good specificity but deficient sensitivity. A diagnostic approach for myocardial involvement based exclusively on symptoms would be less sensitive than one based on symptoms, echo, and troponin level evaluations. Abnormality of any of these evaluations would be an indication for CMR.

2.
Neuro Oncol ; 2024 Jul 06.
Article in English | MEDLINE | ID: mdl-38970818

ABSTRACT

PET imaging, particularly using amino acid tracers, has become a valuable adjunct to anatomical MRI in the clinical management of patients with glioma. Collaborative international efforts have led to the development of clinical and technical guidelines for PET imaging in gliomas. The increasing readiness of statutory health insurance agencies, especially in European countries, to reimburse amino acid PET underscores its growing importance in clinical practice. Integrating artificial intelligence and radiomics in PET imaging of patients with glioma may significantly improve tumor detection, segmentation, and response assessment. Efforts are ongoing to facilitate the clinical translation of these techniques. Considerable progress in computer technology developments (eg quantum computers) may be helpful to accelerate these efforts. Next-generation PET scanners, such as long-axial field-of-view PET/CT scanners, have improved image quality and body coverage and therefore expanded the spectrum of indications for PET imaging in Neuro-Oncology (eg PET imaging of the whole spine). Encouraging results of clinical trials in patients with glioma have prompted the development of PET tracers directing therapeutically relevant targets (eg the mutant isocitrate dehydrogenase) for novel anticancer agents in gliomas to improve response assessment. In addition, the success of theranostics for the treatment of extracranial neoplasms such as neuroendocrine tumors and prostate cancer has currently prompted efforts to translate this approach to patients with glioma. These advancements highlight the evolving role of PET imaging in Neuro-Oncology, offering insights into tumor biology and treatment response, thereby informing personalized patient care. Nevertheless, these innovations warrant further validation in the near future.

3.
EJNMMI Res ; 14(1): 58, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38922458

ABSTRACT

BACKGROUND: O-(2-[18F]fluoroethyl)-L-tyrosine positron emission tomography ([18F]FET PET) scanning is used in routine clinical management and evaluation of gliomas with a recommended 4 h prior fasting. Knowledge of test-retest variation of [18F]FET PET imaging uptake metrics and the impact of accidental protein intake can be critical for interpretation. The aim of this study was to investigate the repeatability of [18F]FET-PET metrics and to assess the impact of protein-intake prior to [18F]FET PET scanning of gliomas. RESULTS: Test-retest variability in the non-protein group was good with absolute (and relative) upper and lower limits of agreement of + 0.15 and - 0.13 (+ 9.7% and - 9.0%) for mean tumour-to-background ratio (TBRmean), + 0.43 and - 0.28 (+ 19.6% and - 11.8%) for maximal tumour-to-background ratio (TBRmax), and + 2.14 cm3 and - 1.53 ml (+ 219.8% and - 57.3%) for biological tumour volume (BTV). Variation was lower for uptake ratios than for BTV. Protein intake was associated with a 27% increase in the total sum of plasma concentration of the L-type amino acid transporter 1 (LAT1) relevant amino acids and with decreased standardized uptake value (SUV) in both healthy appearing background brain tissue (mean SUV - 25%) and in tumour (maximal SUV - 14%). Oral intake of 24 g of protein 1 h prior to injection of tracer tended to increase variability, but the effects on derived tumour metrics TBRmean and TBRmax were only borderline significant, and changes generally within the variability observed in the group with no protein intake. CONCLUSION: The test-retest repeatability was found to be good, and better for TBRmax and TBRmean than BTV, with the methodological limitation that tumour growth may have influenced results. Oral intake of 24 g of protein one hour before a [18F]FET PET scan decreases uptake of [18F]FET in both tumour and in healthy appearing brain, with no clinically significant difference on the most commonly used tumour metrics.

4.
Clin Nucl Med ; 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38914105

ABSTRACT

ABSTRACT: Intracranial mesenchymal tumor, FET-CREB fusion positive, is a newly recognized and rare CNS tumor that occurs primarily in children and young adults. It is regarded as the intracranial variant of angiomatoid fibrous histiocytoma. Extracranial angiomatoid fibrous histiocytomas are typically located in the extremities and usually discernible on a 18F-FDG PET/CT scanning. We present a 50-year-old man with recurrence of a primary intracranial mesenchymal tumor with equivocal 18F-FDG PET/CT findings but with subsequent highly increased metabolic activity using 18F-FET PET/CT confirming tumor recurrence. This case highlights the importance of 18F-FET PET/CT, as opposed to 18F-FDG, in the clinical evaluation of this rare intracranial mesenchymal tumor.

5.
Article in English | MEDLINE | ID: mdl-38898354

ABSTRACT

PURPOSE: To provide practice guideline/procedure standards for diagnostics and therapy (theranostics) of meningiomas using radiolabeled somatostatin receptor (SSTR) ligands. METHODS: This joint practice guideline/procedure standard was collaboratively developed by the European Association of Nuclear Medicine (EANM), the Society of Nuclear Medicine and Molecular Imaging (SNMMI), the European Association of Neurooncology (EANO), and the PET task force of the Response Assessment in Neurooncology Working Group (PET/RANO). RESULTS: Positron emission tomography (PET) using somatostatin receptor (SSTR) ligands can detect meningioma tissue with high sensitivity and specificity and may provide clinically relevant information beyond that obtained from structural magnetic resonance imaging (MRI) or computed tomography (CT) imaging alone. SSTR-directed PET imaging can be particularly useful for differential diagnosis, delineation of meningioma extent, detection of osseous involvement, and the differentiation between posttherapeutic scar tissue and tumour recurrence. Moreover, SSTR-peptide receptor radionuclide therapy (PRRT) is an emerging investigational treatment approach for meningioma. CONCLUSION: These practice guidelines will define procedure standards for the application of PET imaging in patients with meningiomas and related SSTR-targeted PRRTs in routine practice and clinical trials and will help to harmonize data acquisition and interpretation across centers, facilitate comparability of studies, and to collect larger databases. The current document provides additional information to the evidence-based recommendations from the PET/RANO Working Group regarding the utilization of PET imaging in meningiomas Galldiks (Neuro Oncol. 2017;19(12):1576-87). The information provided should be considered in the context of local conditions and regulations.

6.
Heart Rhythm ; 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38588993

ABSTRACT

BACKGROUND: Catecholaminergic polymorphic ventricular tachycardia (CPVT) may cause sudden cardiac death (SCD) despite medical therapy. Therefore, implantable cardioverter-defibrillators (ICDs) are commonly advised. However, there is limited data on the outcomes of ICD use in children. OBJECTIVE: The purpose of this study was to compare the risk of arrhythmic events in pediatric patients with CPVT with and without an ICD. METHODS: We compared the risk of SCD in patients with RYR2 (ryanodine receptor 2) variants and phenotype-positive symptomatic CPVT patients with and without an ICD who were younger than 19 years and had no history of sudden cardiac arrest at phenotype diagnosis. The primary outcome was SCD; secondary outcomes were composite end points of SCD, sudden cardiac arrest, or appropriate ICD shocks with or without arrhythmic syncope. RESULTS: The study included 235 patients, 73 with an ICD (31.1%) and 162 without an ICD (68.9%). Over a median follow-up of 8.0 years (interquartile range 4.3-13.4 years), SCD occurred in 7 patients (3.0%), of whom 4 (57.1%) were noncompliant with medications and none had an ICD. Patients with ICD had a higher risk of both secondary composite outcomes (without syncope: hazard ratio 5.85; 95% confidence interval 3.40-10.09; P < .0001; with syncope: hazard ratio 2.55; 95% confidence interval 1.50-4.34; P = .0005). Thirty-one patients with ICD (42.5%) experienced appropriate shocks, 18 (24.7%) inappropriate shocks, and 21 (28.8%) device-related complications. CONCLUSION: SCD events occurred only in patients without an ICD and mostly in those not on optimal medical therapy. Patients with an ICD had a high risk of appropriate and inappropriate shocks, which may be reduced with appropriate device programming. Severe ICD complications were common, and risks vs benefits of ICDs need to be considered.

7.
JACC Case Rep ; 29(9): 102314, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38550909

ABSTRACT

The integration of smart watches into health care has heralded a new era in the diagnosis and monitoring of various medical conditions, including arrhythmias. However, it is imperative to acknowledge the limitations associated with smart watches in health care. We present a challenging tracing acquired from an Apple Watch.

8.
Parkinsonism Relat Disord ; 122: 106062, 2024 May.
Article in English | MEDLINE | ID: mdl-38452445

ABSTRACT

INTRODUCTION: Visual rating of the cingulate island sign (CIS) on [18F]fluorodeoxyglucose ([18F]FDG) positron emission tomography (PET) has a high specificity for dementia with Lewy bodies (DLB) in selected cohorts such as DLB versus Alzheimer's disease (AD). In a mixed memory clinical population this study aimed to uncover the prevalence of CIS, the diagnostic accuracy for DLB, and the relationship between CIS and disease severity. METHODS: CIS on [18F]FDG-PET was retrospectively assessed with the visual CIS rating scale (CISRs) in 1000 patients with a syndrome diagnosis of mild cognitive impairment (MCI) or dementia with no restrictions in etiological diagnosis. RESULTS: In this cohort 24.3 % had a CISRs score ≥1 and 3.5 % had a CISRs score = 4. The prevalence of a CISRs score ≥1 was highest in DLB (74.0 %, n = 57). A CISRs score ≥1 was present in at least 9 % in other diagnostic groups. The prevalence of CIS across disease severities showed no statistically significant difference (p = 0.23). To differentiate DLB from non-DLB the optimal cut-off was a CISRs score ≥1 (balanced accuracy = 77.1 %) in MCI/mild dementia and a CISRs score ≥2 (balanced accuracy = 80.6 %) in moderate/severe dementia. The positive predictive value of a CISRs score = 4 for DLB was 57.7 % in MCI/mild dementia and 33.3 % in moderate/severe dementia. CONCLUSION: The CISRs is useful in differentiating DLB from other etiologies in a mixed memory clinical population. Balanced accuracy and positive predictive value may vary across disease severities in the population studied.


Subject(s)
Cognitive Dysfunction , Fluorodeoxyglucose F18 , Gyrus Cinguli , Lewy Body Disease , Positron-Emission Tomography , Humans , Male , Female , Aged , Lewy Body Disease/epidemiology , Lewy Body Disease/diagnostic imaging , Lewy Body Disease/diagnosis , Cognitive Dysfunction/diagnostic imaging , Cognitive Dysfunction/epidemiology , Cognitive Dysfunction/diagnosis , Prevalence , Retrospective Studies , Middle Aged , Gyrus Cinguli/diagnostic imaging , Aged, 80 and over , Cohort Studies , Sensitivity and Specificity
9.
Neuro Oncol ; 26(7): 1181-1194, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38466087

ABSTRACT

Brain tumor diagnostics have significantly evolved with the use of positron emission tomography (PET) and advanced magnetic resonance imaging (MRI) techniques. In addition to anatomical MRI, these modalities may provide valuable information for several clinical applications such as differential diagnosis, delineation of tumor extent, prognostication, differentiation between tumor relapse and treatment-related changes, and the evaluation of response to anticancer therapy. In particular, joint recommendations of the Response Assessment in Neuro-Oncology (RANO) Group, the European Association of Neuro-oncology, and major European and American Nuclear Medicine societies highlighted that the additional clinical value of radiolabeled amino acids compared to anatomical MRI alone is outstanding and that its widespread clinical use should be supported. For advanced MRI and its steadily increasing use in clinical practice, the Standardization Subcommittee of the Jumpstarting Brain Tumor Drug Development Coalition provided more recently an updated acquisition protocol for the widely used dynamic susceptibility contrast perfusion MRI. Besides amino acid PET and perfusion MRI, other PET tracers and advanced MRI techniques (e.g. MR spectroscopy) are of considerable clinical interest and are increasingly integrated into everyday clinical practice. Nevertheless, these modalities have shortcomings which should be considered in clinical routine. This comprehensive review provides an overview of potential challenges, limitations, and pitfalls associated with PET imaging and advanced MRI techniques in patients with gliomas or brain metastases. Despite these issues, PET imaging and advanced MRI techniques continue to play an indispensable role in brain tumor management. Acknowledging and mitigating these challenges through interdisciplinary collaboration, standardized protocols, and continuous innovation will further enhance the utility of these modalities in guiding optimal patient care.


Subject(s)
Brain Neoplasms , Magnetic Resonance Imaging , Positron-Emission Tomography , Humans , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/pathology , Positron-Emission Tomography/methods , Magnetic Resonance Imaging/methods
10.
Eur J Nucl Med Mol Imaging ; 51(7): 1891-1908, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38393374

ABSTRACT

Epilepsy is one of the most frequent neurological conditions with an estimated prevalence of more than 50 million people worldwide and an annual incidence of two million. Although pharmacotherapy with anti-seizure medication (ASM) is the treatment of choice, ~30% of patients with epilepsy do not respond to ASM and become drug resistant. Focal epilepsy is the most frequent form of epilepsy. In patients with drug-resistant focal epilepsy, epilepsy surgery is a treatment option depending on the localisation of the seizure focus for seizure relief or seizure freedom with consecutive improvement in quality of life. Beside examinations such as scalp video/electroencephalography (EEG) telemetry, structural, and functional magnetic resonance imaging (MRI), which are primary standard tools for the diagnostic work-up and therapy management of epilepsy patients, molecular neuroimaging using different radiopharmaceuticals with single-photon emission computed tomography (SPECT) and positron emission tomography (PET) influences and impacts on therapy decisions. To date, there are no literature-based praxis recommendations for the use of Nuclear Medicine (NM) imaging procedures in epilepsy. The aims of these guidelines are to assist in understanding the role and challenges of radiotracer imaging for epilepsy; to provide practical information for performing different molecular imaging procedures for epilepsy; and to provide an algorithm for selecting the most appropriate imaging procedures in specific clinical situations based on current literature. These guidelines are written and authorized by the European Association of Nuclear Medicine (EANM) to promote optimal epilepsy imaging, especially in the presurgical setting in children, adolescents, and adults with focal epilepsy. They will assist NM healthcare professionals and also specialists such as Neurologists, Neurophysiologists, Neurosurgeons, Psychiatrists, Psychologists, and others involved in epilepsy management in the detection and interpretation of epileptic seizure onset zone (SOZ) for further treatment decision. The information provided should be applied according to local laws and regulations as well as the availability of various radiopharmaceuticals and imaging modalities.


Subject(s)
Epilepsy , Positron-Emission Tomography , Tomography, Emission-Computed, Single-Photon , Humans , Epilepsy/diagnostic imaging , Positron-Emission Tomography/methods , Positron-Emission Tomography/standards , Nuclear Medicine , Europe
11.
Lancet Oncol ; 25(1): e29-e41, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38181810

ABSTRACT

Response Assessment in Neuro-Oncology (RANO) response criteria have been established and were updated in 2023 for MRI-based response evaluation of diffuse gliomas in clinical trials. In addition, PET-based imaging with amino acid tracers is increasingly considered for disease monitoring in both clinical practice and clinical trials. So far, a standardised framework defining timepoints for baseline and follow-up investigations and response evaluation criteria for PET imaging of diffuse gliomas has not been established. Therefore, in this Policy Review, we propose a set of criteria for response assessment based on amino acid PET imaging in clinical trials enrolling participants with diffuse gliomas as defined in the 2021 WHO classification of tumours of the central nervous system. These proposed PET RANO criteria provide a conceptual framework that facilitates the structured implementation of PET imaging into clinical research and, ultimately, clinical routine. To this end, the PET RANO 1.0 criteria are intended to encourage specific investigations of amino acid PET imaging of gliomas.


Subject(s)
Glioma , Neurology , Humans , Glioma/diagnostic imaging , Glioma/therapy , Amino Acids , Internal Medicine , Positron-Emission Tomography , Transcription Factors
12.
Eur J Nucl Med Mol Imaging ; 51(3): 707-720, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37843600

ABSTRACT

PURPOSE: New total-body PET scanners with a long axial field of view (LAFOV) allow for higher temporal resolution due to higher sensitivity, which facilitates perfusion estimation by model-free deconvolution. Fundamental tracer kinetic theory predicts that perfusion can be estimated for all tracers despite their different fates given sufficiently high temporal resolution of 1 s or better, bypassing the need for compartment modelling. The aim of this study was to investigate whether brain perfusion could be estimated using model-free Tikhonov generalized deconvolution for five different PET tracers, [15O]H2O, [11C]PIB, [18F]FE-PE2I, [18F]FDG and [18F]FET. To our knowledge, this is the first example of a general model-free approach to estimate cerebral blood flow (CBF) from PET data. METHODS: Twenty-five patients underwent dynamic LAFOV PET scanning (Siemens, Quadra). PET images were reconstructed with an isotropic voxel resolution of 1.65 mm3. Time framing was 40 × 1 s during bolus passage followed by increasing framing up to 60 min. AIF was obtained from the descending aorta. Both voxel- and region-based calculations of perfusion in the thalamus were performed using the Tikhonov method. The residue impulse response function was used to estimate the extraction fraction of tracer leakage across the blood-brain barrier. RESULTS: CBF ranged from 37 to 69 mL blood min-1 100 mL of tissue-1 in the thalamus. Voxelwise calculation of CBF resulted in CBF maps in the physiologically normal range. The extraction fractions of [15O]H2O, [18F]FE-PE2I, [11C]PIB, [18F]FDG and [18F]FET in the thalamus were 0.95, 0.78, 0.62, 0.19 and 0.03, respectively. CONCLUSION: The high temporal resolution and sensitivity associated with LAFOV PET scanners allow for noninvasive perfusion estimation of multiple tracers. The method provides an estimation of the residue impulse response function, from which the fate of the tracer can be studied, including the extraction fraction, influx constant, volume of distribution and transit time distribution, providing detailed physiological insight into normal and pathologic tissue.


Subject(s)
Positron Emission Tomography Computed Tomography , Positron-Emission Tomography , Humans , Positron-Emission Tomography/methods , Fluorodeoxyglucose F18 , Brain/diagnostic imaging , Perfusion
13.
J Stroke Cerebrovasc Dis ; 33(1): 107466, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38029459

ABSTRACT

OBJECTIVES: Quantitative regional cerebral perfusion (rCBF) measurements using [15O]H2O PET with arterial cannulation and acetazolamide (ACZ) challenge have been reserved to identify high-risk patients that are candidates for by-pass operation. We aimed to assess the prognostic value of various parameters in quantitative [15O]H2O PET measurements in patients not subsequently undergoing surgery. METHODS: We identified 32 eligible patients who underwent [15O]H2O brain PET imaging for suspicion of hemodynamic insufficiency between 2009 and 2020. Cerebrovascular events were defined as new ischemic lesions on MRI, stroke, transient ischemic attack, vascular dementia. Follow-up period was 91 months (range: 26-146). rCBF before (rCBFbase) and after (rCBFacz) ACZ challenge and the relative increase (CVR), were examined in the anterior (ACA), middle (MCA), and posterior (PCA) cerebral artery territories of the affected hemisphere, and the most recent MRI scans were scored for infarcts and white matter lesions. RESULTS: Receiver operating characteristic (ROC) curve analysis showed higher prognostic accuracy for rCBFacz(AUC:0.82) compared to CVR (AUC:0.72) and rCBFbase (AUC:0.77). ROC AUC, optimal thresholds (and corresponding sensitivity/specificity/accuracy) for rCBFacz after ACZ in individual territories were 0.79 and 37.8 mL 100g-1 min-1 (0.81/0.63/0.72) for the ACA, 0.84 and 32 mL 100g-1 min-1 (0.81/0.75/0.78) for the MCA, and 0.70 and 43.9 ml/(mL 100g-1 min-1 (0.81/0.43/0,62) for the PCA. Kaplan Meier survival curve showed longer event-free survival in patients with rCBFacz below cut-off (p=0.007). In multivariate analysis rCBFacz remained a significant predictor when correcting for age. CONCLUSION: Quantitative rCBF measurements after ACZ challenge with [15O]H2O PET provided high prognostic value for future cerebrovascular events.


Subject(s)
Brain , Positron-Emission Tomography , Humans , Prognosis , Positron-Emission Tomography/methods , Brain/diagnostic imaging , Brain/blood supply , Acetazolamide , Hemodynamics , Cerebrovascular Circulation
14.
Geroscience ; 46(1): 769-782, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38102439

ABSTRACT

AIMS: Alzheimer's disease (AD) is characterized by the accumulation of amyloid beta (Aß) in the brain. The deposition of Aß is believed to initiate a detrimental cascade, including cerebral hypometabolism, accelerated brain atrophy, and cognitive problems-ultimately resulting in AD. However, the timing and causality of the cascade resulting in AD are not yet fully established. Therefore, we examined whether early Aß accumulation affects cerebral glucose metabolism, atrophy rate, and age-related cognitive decline before the onset of neurodegenerative disease. METHODS: Participants from the Metropolit 1953 Danish Male Birth Cohort underwent brain positron emission tomography (PET) imaging using the radiotracers [11C]Pittsburgh Compound-B (PiB) (N = 70) and [18F]Fluorodeoxyglucose (FDG) (N = 76) to assess cerebral Aß accumulation and glucose metabolism, respectively. The atrophy rate was calculated from anatomical magnetic resonance imaging (MRI) scans conducted presently and 10 years ago. Cognitive decline was examined from neurophysiological tests conducted presently and ten or 5 years ago. RESULTS: Higher Aß accumulation in AD-critical brain regions correlated with greater visual memory decline (p = 0.023). Aß accumulation did not correlate with brain atrophy rates. Increased cerebral glucose metabolism in AD-susceptible regions correlated with worse verbal memory performance (p = 0.040). CONCLUSIONS: Aß accumulation in known AD-related areas was associated with subtle cognitive deficits. The association was observed before hypometabolism or accelerated brain atrophy, suggesting that Aß accumulation is involved early in age-related cognitive dysfunction. The association between hypermetabolism and worse memory performance may be due to early compensatory mechanisms adapting for malfunctioning neurons by increasing metabolism.


Subject(s)
Alzheimer Disease , Cognitive Dysfunction , Neurodegenerative Diseases , Humans , Male , Amyloid beta-Peptides/metabolism , Cognitive Dysfunction/metabolism , Cognition , Atrophy , Glucose/metabolism
15.
Diagnostics (Basel) ; 13(24)2023 Dec 14.
Article in English | MEDLINE | ID: mdl-38132245

ABSTRACT

Recent advancements in PET/CT, including the emergence of long axial field-of-view (LAFOV) PET/CT scanners, have increased PET sensitivity substantially. Consequently, there has been a significant reduction in the required tracer activity, shifting the primary source of patient radiation dose exposure to the attenuation correction (AC) CT scan during PET imaging. This study proposes a parameter-transferred conditional generative adversarial network (PT-cGAN) architecture to generate synthetic CT (sCT) images from non-attenuation corrected (NAC) PET images, with separate networks for [18F]FDG and [15O]H2O tracers. The study includes a total of 1018 subjects (n = 972 [18F]FDG, n = 46 [15O]H2O). Testing was performed on the LAFOV scanner for both datasets. Qualitative analysis found no differences in image quality in 30 out of 36 cases in FDG patients, with minor insignificant differences in the remaining 6 cases. Reduced artifacts due to motion between NAC PET and CT were found. For the selected organs, a mean average error of 0.45% was found for the FDG cohort, and that of 3.12% was found for the H2O cohort. Simulated low-count images were included in testing, which demonstrated good performance down to 45 s scans. These findings show that the AC of total-body PET is feasible across tracers and in low-count studies and might reduce the artifacts due to motion and metal implants.

16.
Pediatr Cardiol ; 2023 Sep 09.
Article in English | MEDLINE | ID: mdl-37684488

ABSTRACT

Hypertrophic cardiomyopathy (HCM), a common cardiomyopathy in children, is an important cause of morbidity and mortality. Early recognition and appropriate management are important. An electrocardiogram (ECG) is often used as a screening tool in children to detect heart disease. The ECG patterns in children with HCM are not well described.ECGs collected from an international cohort of children, and adolescents (≤ 21 years) with HCM were reviewed. 482 ECGs met inclusion criteria. Age ranged from 1 day to 21 years, median 13 years. Of the 482 ECGs, 57 (12%) were normal. The most common abnormalities noted were left ventricular hypertrophy (LVH) in 108/482 (22%) and biventricular hypertrophy (BVH) in 116/482 (24%) Of the patients with LVH/BVH (n = 224), 135 (60%) also had a strain pattern (LVH in 83, BVH in 52). Isolated strain pattern (in the absence of criteria for hypertrophy) was seen in 43/482 (9%). Isolated pathologic Q waves were seen in 71/482 (15%). Pediatric HCM, 88% have an abnormal ECG. The most common ECG abnormalities were LVH or BVH with or without strain. Strain pattern without hypertrophy and a pathologic Q wave were present in a significant proportion (24%) of patients. Thus, a significant number of children with HCM have ECG abnormalities that are not typical for "hypertrophy". The presence of the ECG abnormalities described above in a child should prompt further examination with an echocardiogram to rule out HCM.

17.
J Cancer Policy ; 38: 100438, 2023 12.
Article in English | MEDLINE | ID: mdl-37634617

ABSTRACT

European Cancer Organisation Essential Requirements for Quality Cancer Care (ERQCCs) are explanations of the organisation and actions necessary to provide high-quality care to patients with a specific cancer type. They are compiled by a working group of European experts representing disciplines involved in cancer care, and provide oncology teams, patients, policymakers and managers with an overview of the essential requirements in any healthcare system. The focus here is on adult glioma. Gliomas make up approximately 80% of all primary malignant brain tumours. They are highly diverse and patients can face a unique cognitive, physical and psychosocial burden, so personalised treatments and support are essential. However, management of gliomas is currently very heterogeneous across Europe and there are only few formally-designated comprehensive cancer centres with brain tumour programmes. To address this, the ERQCC glioma expert group proposes frameworks and recommendations for high quality care, from diagnosis to treatment and survivorship. Wherever possible, glioma patients should be treated from diagnosis onwards in high volume neurosurgical or neuro-oncology centres. Multidisciplinary team working and collaboration is essential if patients' length and quality of life are to be optimised.


Subject(s)
Glioma , Quality of Life , Adult , Humans , Delivery of Health Care , Glioma/diagnosis , Medical Oncology , Quality of Health Care
18.
Eur J Nucl Med Mol Imaging ; 50(12): 3513-3537, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37624384

ABSTRACT

PREAMBLE: The Society of Nuclear Medicine and Molecular Imaging (SNMMI) is an international scientific and professional organization founded in 1954 to promote the science, technology, and practical application of nuclear medicine. The European Association of Nuclear Medicine (EANM) is a professional non-profit medical association that facilitates communication worldwide between individuals pursuing clinical and research excellence in nuclear medicine. The EANM was founded in 1985. The merged International Society for Magnetic Resonance in Medicine (ISMRM) is an international, nonprofit, scientific association whose purpose is to promote communication, research, development, and applications in the field of magnetic resonance in medicine and biology and other related topics and to develop and provide channels and facilities for continuing education in the field.The ISMRM was founded in 1994 through the merger of the Society of Magnetic Resonance in Medicine and the Society of Magnetic Resonance Imaging. SNMMI, ISMRM, and EANM members are physicians, technologists, and scientists specializing in the research and practice of nuclear medicine and/or magnetic resonance imaging. The SNMMI, ISMRM, and EANM will periodically define new guidelines for nuclear medicine practice to help advance the science of nuclear medicine and/or magnetic resonance imaging and to improve the quality of service to patients throughout the world. Existing practice guidelines will be reviewed for revision or renewal, as appropriate, on their fifth anniversary or sooner, if indicated. Each practice guideline, representing a policy statement by the SNMMI/EANM/ISMRM, has undergone a thorough consensus process in which it has been subjected to extensive review. The SNMMI, ISMRM, and EANM recognize that the safe and effective use of diagnostic nuclear medicine imaging and magnetic resonance imaging requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guideline by those entities not providing these services is not authorized. These guidelines are an educational tool designed to assist practitioners in providing appropriate care for patients. They are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care. For these reasons and those set forth below, the SNMMI, the ISMRM, and the EANM caution against the use of these guidelines in litigation in which the clinical decisions of a practitioner are called into question. The ultimate judgment regarding the propriety of any specific procedure or course of action must be made by the physician or medical physicist in light of all the circumstances presented. Thus, there is no implication that an approach differing from the guidelines, standing alone, is below the standard of care. To the contrary, a conscientious practitioner may responsibly adopt a course of action different from that set forth in the guidelines when, in the reasonable judgment of the practitioner, such course of action is indicated by the condition of the patient, limitations of available resources, or advances in knowledge or technology subsequent to publication of the guidelines. The practice of medicine includes both the art and the science of the prevention, diagnosis, alleviation, and treatment of disease. The variety and complexity of human conditions make it impossible to always reach the most appropriate diagnosis or to predict with certainty a particular response to treatment. Therefore, it should be recognized that adherence to these guidelines will not ensure an accurate diagnosis or a successful outcome. All that should be expected is that the practitioner will follow a reasonable course of action based on current knowledge, available resources, and the needs of the patient to deliver effective and safe medical care. The sole purpose of these guidelines is to assist practitioners in achieving this objective.

19.
EJNMMI Phys ; 10(1): 44, 2023 Jul 14.
Article in English | MEDLINE | ID: mdl-37450069

ABSTRACT

INTRODUCTION: Estimation of brain amyloid accumulation is valuable for evaluation of patients with cognitive impairment in both research and clinical routine. The development of high throughput and accurate strategies for the determination of amyloid status could be an important tool in patient selection for clinical trials and amyloid directed treatment. Here, we propose the use of deep learning to quantify amyloid accumulation using standardized uptake value ratio (SUVR) and classify amyloid status based on their PET images. METHODS: A total of 1309 patients with cognitive impairment scanned with [11C]PIB PET/CT or PET/MRI were included. Two convolutional neural networks (CNNs) for reading-based amyloid status and SUVR prediction were trained using 75% of the PET/CT data. The remaining PET/CT (n = 300) and all PET/MRI (n = 100) data was used for evaluation. RESULTS: The prevalence of amyloid positive patients was 61%. The amyloid status classification model reproduced the expert reader's classification with 99% accuracy. There was a high correlation between reference and predicted SUVR (R2 = 0.96). Both reference and predicted SUVR had an accuracy of 97% compared to expert classification when applying a predetermined SUVR threshold of 1.35 for binary classification of amyloid status. CONCLUSION: The proposed CNN models reproduced both the expert classification and quantitative measure of amyloid accumulation in a large local dataset. This method has the potential to replace or simplify existing clinical routines and can facilitate fast and accurate classification well-suited for a high throughput pipeline.

20.
J Neurol Sci ; 451: 120719, 2023 08 15.
Article in English | MEDLINE | ID: mdl-37421880

ABSTRACT

INTRODUCTION: The cingulate island sign (CIS) is a metabolic pattern on [18F]fluorodeoxyglucose ([18F]FDG) positron emission tomography (PET) associated with dementia with Lewy bodies (DLB). The aim of this study was to validate the visual CIS rating scale (CISRs) for the diagnosis of DLB and to explore the clinical correlates. METHODS: This single-center study included 166 DLB patients and 161 patients with Alzheimer's disease (AD). The CIS on [18F]FDG-PET scans was rated using the CISRs independently by three blinded raters. RESULTS: The optimal cut-off to differentiate DLB from AD was a CISRs score ≥ 1 (sensitivity = 66%, specificity = 84%) whereas a CISRs score ≥ 2 (sensitivity = 58%, specificity = 92%) was optimal to differentiate amyloid positive DLB (n = 43 (82.7%)) and AD. To identify DLB with abnormal (n = 53 (72.6%)) versus normal (n = 20 (27.4%)) dopamine transporter imaging, a CISRs cut-off of 4 had a specificity of 95%. DLB with a CISRs score of 4 performed significantly better in tests on free verbal recall and picture based cued recall, but worse on processing speed compared to DLB with a CISRs score of 0. CONCLUSION: This study confirms the CISRs as a valid marker for the diagnosis of DLB with a high specificity and a lower, but acceptable, sensitivity. Concomitant AD pathology does not influence diagnostic accuracy of the CISRs. In DLB patients, presence of CIS is associated with relative preserved memory function and impaired processing speed.


Subject(s)
Alzheimer Disease , Lewy Body Disease , Humans , Lewy Body Disease/diagnostic imaging , Lewy Body Disease/metabolism , Fluorodeoxyglucose F18 , Positron-Emission Tomography , Alzheimer Disease/diagnostic imaging , Alzheimer Disease/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...