Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Neurointerv Surg ; 14(4): 366-370, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34266907

ABSTRACT

The Woven EndoBridge (WEB) device is a barrel-shaped nitinol mesh deployed within the aneurysmal sac. The absence of metallic mesh in the aneurysm's parent vessel lumen obviates the need for potent antiplatelet therapy, making this device appealing for acutely ruptured aneurysms not amenable to clipping or coiling. To assess the literature regarding WEB treatment of these aneurysms, we performed a comprehensive systematic search of PubMed, MEDLINE, and EMBASE databases following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Keywords were combined with Boolean operators to increase search sensitivity and specificity ('woven endobridge device' AND 'ruptured'). Nine studies comprising 377 acutely ruptured aneurysms were included. Overall, 82.7% were wide-necked, 85.9% were located in the anterior circulation, and 26.9% of patients presented with poor subarachnoid hemorrhage grade. Intraprocedure and postprocedure complications occurred in 8.4% (95% CI 3.6% to 13.3%) and 1% (95% CI 0% to 2%), respectively. The post-treatment rebleeding rate was 0%. Rates of adequate occlusion (complete occlusion to neck remnant) and retreatment at last follow-up were 84.8% (95% CI 73% to 96.6%) and 4.5% (95% CI 2.2% to 6.8%), respectively. The favorable outcome rate (modified Rankin Scale score 0-2) was 62.2% (95% CI 53% to 71.4%); mortality was 13.6% (95% CI 9.7% to 17.6%). WEB treatment of acutely ruptured aneurysms results in high adequate occlusion rates, low perioperative complication rates, no rebleeding, and low recurrence requiring retreatment. This device is promising for acutely ruptured aneurysms not amenable to clipping or coiling, considering the lower need for antiplatelet regimens during the procedure or follow-up.


Subject(s)
Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/surgery , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Humans , Intracranial Aneurysm/complications , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Retrospective Studies , Treatment Outcome
2.
Brain Circ ; 7(4): 289-293, 2021.
Article in English | MEDLINE | ID: mdl-35071848

ABSTRACT

A Caucasian man in his 60s with a history of Cognard Type IIB dural arteriovenous fistula presented to the emergency room with right eye proptosis, chemosis, hyperemia, epiphora, diplopia, and blurred vision. Magnetic resonance imaging and magnetic resonance angiography revealed spontaneous, bilateral Barrow Type D carotid-cavernous fistulas (CCFs) that were later confirmed through cerebral angiography. The patient had no history of head or ocular trauma. Given the acute nature of presentation and worsening diplopia, the patient was scheduled for transvenous embolization. However, during the preprocedure angiogram, spontaneous resolution of the bilateral CCFs was observed. Complete resolution of all symptoms was noticed during follow-up. Given the rare nature of bilateral, indirect CCFs, our case stands out as the only reported instance whereby resolution of bilateral, indirect CCFs occurred spontaneously without any intervention.

SELECTION OF CITATIONS