Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Type of study
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-39066744

ABSTRACT

BACKGROUND: New postprocessing software facilitates 3-dimensional (3D) echocardiographic determination of mitral annular (MA) and neo-left ventricular outflow tract (neo-LVOT) dimensions in patients undergoing transcatheter mitral valve replacement (TMVR). OBJECTIVES: This study aims to test the accuracy of 3D echocardiographic analysis as compared to baseline computed tomography (CT). METHODS: A total of 105 consecutive patients who underwent TMVR at 2 tertiary care centers between October 2017 and May 2023 were retrospectively included. A virtual valve was projected in both baseline CT and 3D transesophageal echocardiography (TEE) using dedicated software. MA dimensions were measured in baseline images and neo-LVOT dimensions were measured in baseline and postprocedural images. All measurements were compared to baseline CT as a reference. The predicted neo-LVOT area was correlated with postprocedural peak LVOT gradients. RESULTS: There was no significant bias in baseline neo-LVOT prediction between both imaging modalities. TEE significantly underestimated MA area, perimeter, and medial-lateral dimension compared to CT. Both modalities significantly underestimated the actual neo-LVOT area (mean bias pre/post TEE: 25.6 mm2, limit of agreement: -92.2 mm2 to 143.3 mm2; P < 0.001; mean bias pre/post CT: 28.3 mm2, limit of agreement: -65.8 mm2 to 122.4 mm2; P = 0.046), driven by neo-LVOT underestimation in the group treated with dedicated mitral valve bioprosthesis. Both CT- and TEE-predicted-neo-LVOT areas exhibited an inverse correlation with postprocedural LVOT gradients (r2 = 0.481; P < 0.001 for TEE and r2 = 0.401; P < 0.001 for CT). CONCLUSIONS: TEE-derived analysis provides comparable results with CT-derived metrics in predicting the neo-LVOT area and peak gradient after TMVR.

3.
Heart Fail Clin ; 19(3): 329-343, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37230648

ABSTRACT

Given the independent association of mortality with higher grades of tricuspid regurgitation severity, there is an increasing interest in improving the outcomes of this prevalent valvular heart disease. A new classification of tricuspid regurgitation etiology allows for an improved understanding of different pathophysiologic forms of the disease, which may determine the appropriate management strategy. Current surgical outcomes remain suboptimal and multiple transcatheter device therapies are currently under investigation to give high and prohibitive surgical risk patients treatment options beyond medical therapy.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects , Heart Failure/etiology , Heart Failure/therapy , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL