Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Vasc Interv Radiol ; 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38554948

ABSTRACT

PURPOSE: To evaluate the clinical effectiveness and safety of drug-coated balloons (DCBs) compared with those of percutaneous transluminal angioplasty (PTA) for arteriovenous fistula (AVF) stenosis via a review of systematic reviews (SRs) and an update of the current meta-analysis. MATERIALS AND METHODS: Literature was searched to retrieve SRs comparing DCBs and PTA for AVFs. A narrative review of SRs and pooled analysis were performed. RESULTS: Eleven SRs were included. DCBs demonstrated favorable outcomes at 6 and 12 months compared with PTA, with improved patency in 7 SRs and a trend toward favorable outcomes without statistical significance in 3 SRs. Target lesion revascularization (TLR) was reported in 3 SRs; 2 reviews reported a significantly lower incidence in the DCB group than in the PTA group, whereas 1 review reported no significant differences at 12 months. Four studies reporting all-cause mortality revealed no significant difference between the 2 treatments. In the updated meta-analysis including 23 studies, DCBs demonstrated improved primary patency at 6 months (risk ratio [RR], 1.27; 95% CI, 1.07-1.50) and 12 months (RR, 1.36; 95% CI, 1.19-1.55) and were associated with a lower incidence of TLR at 6 months (RR, 0.54; 95% CI, 0.41-0.73) and 12 months (RR, 0.78; 95% CI, 0.62-0.99). There was no difference in mortality between the 2 groups for 24 months. CONCLUSIONS: A review of SRs and meta-analysis update revealed the consistent benefits of DCBs over PTA in treating AVFs in terms of primary patency and TLR. Compared with PTA, DCBs do not increase mortality risk.

2.
Value Health Reg Issues ; 42: 18-25, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38350187

ABSTRACT

OBJECTIVES: This study aimed to assess the impact of the reimbursement regulation of medical devices (Regulation), introduced by the National Health Insurance Administration (NHIA) in 2013, on patients' access to innovative medical devices in Taiwan. METHODS: Analysis of the amount of time needed from application for NHIA reimbursement for new medical devices to receiving the decision from NHIA was done using the nonreimbursement product list featured on the NHIA website. Additionally, Welch analysis of variance was used to compare the amount of time it took from application to NHIA with reimbursement decisions made by the NHIA for different nonreimbursement code categories. Further, related Pharmaceutical Benefit Reimbursement Scheme meeting minutes were analyzed to obtain more detailed information concerning medical devices' reimbursement or not. RESULTS: From December 2012 to June 2021, the overall reimbursement percentage was 56.7%, and the average amount of time between application and reimbursement was 856.7 ± 474.7 days. The mandatory reimbursement rate was about 45%. NHIA reimbursement decisions as special medical devices also take a longer amount of time, because the applicants need to agree to the decision (P < .05). The NHIA decision-making process for nonreimbursement medical devices requires a significantly longer amount of time than for general materials (eg, suture, etc) decisions. CONCLUSIONS: Although the Regulation resolves payment issues, it also increases the amount of time to reach reimbursement decisions, thus hindering patient access to innovative medical devices. The study suggests that the review process needs to be simplified concerning reimbursement notification, using local real-world data to support reimbursement decisions.

3.
Pain Med ; 24(1): 79-88, 2023 01 04.
Article in English | MEDLINE | ID: mdl-35881702

ABSTRACT

OBJECTIVE: To investigate the opioid consumption and the healthcare resource utilization in patients with the intrathecal drug delivery system (IDDS) therapy and the comprehensive medical management (CMM) alone. DESIGN: A retrospective cohort study with a customized claims database. SETTING: In a university-based hospital. SUBJECTS: Patients with complex regional pain syndrome, post-laminectomy syndrome, and fibromyalgia. METHODS: Using propensity score matching (1:3), we selected patients with morphine infusion through IDDS (IDDS group) and CMM alone (CMM group). The primary endpoints were comparisons of average morphine equivalents daily dosages (MEDD, mg/day) for 6 and 12 months from an index date. The number of emergency room (ER) visits and hospitalizations and the total medical expenditures were compared as secondary outcomes. RESULTS: In total, 82 patients (N = 23 in the IDDS group and N = 59 in the CMM group) were analyzed. Although a 6-month average MEDD did not reach statistical significance, a 12-month average MEDD was significantly decreased in the IDDS group compared to the CMM group (53.2 ± 46.3 vs 123.9 ± 176.4, respectively; P = 0.008). ER visits were more frequent in the IDDS group than the CMM group at baseline (5.4 vs 0.5, respectively; P = .002), which was maintained for 12 months (P < 0.001). Otherwise, the number of hospitalization and the medical expenditures for pain management were not different between the groups for 12 months. CONCLUSIONS: The combined IDDS therapy had some benefits in reducing opioid consumption for 1-year follow-up compared to the CMM alone in chronic noncancer pain patients.


Subject(s)
Analgesics, Opioid , Chronic Pain , Humans , Analgesics, Opioid/adverse effects , Morphine , Chronic Pain/drug therapy , Chronic Pain/chemically induced , Retrospective Studies , Infusion Pumps, Implantable , Injections, Spinal
4.
Ann Surg Treat Res ; 101(1): 20-27, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34235113

ABSTRACT

PURPOSE: Drug-coated devices have been widely accepted as one of the most promising therapies for femoropopliteal artery revascularization. A recent meta-analysis showed increased mortality in patients treated with drug-coated devices. We sought to examine the association between mortality and drug-coated devices after the treatment of the femoropopliteal artery based on the Korea national administrative claims data. METHODS: In the National Health Insurance Service database from August 2015 to December 2017, we identified patients with femoropopliteal artery revascularization using percutaneous transluminal angioplasty (PTA), bare metal stents (BMS), drug-coated balloon (DCB), or drug-eluting stents (DES). Kaplan-Meier methods were used to estimate the survival among devices, and log-rank tests were used to evaluate differences between groups. Adjusted hazard ratios (aHRs) were computed using the inverse probability of treatment weightings (IPTW). RESULTS: There were 1,724 patients (mean age, 70.9 ± period was 552 days (interquartile range, 404-688 days). There was a difference in IPTW-adjusted mortality risk among device types (26.3% in PTA, 22.1% in BMS, 17.7% in DCB, and 17.8% in DES; P = 0.004). IPTW-adjusted Cox nproportional hazard analysis showed that drug-coated devices were associated with decreased all-cause mortality risk (aHR, 0.70; 95% confidence interval, 0.58-0.86). CONCLUSION: Our real-world analysis showed that there was no evidence of increased all-cause mortality after femoropopliteal artery revascularization with drug-coated devices compared with non-drug-coated devices.

SELECTION OF CITATIONS
SEARCH DETAIL
...