Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Article in English | MEDLINE | ID: mdl-38747674

ABSTRACT

RATIONALE: Idiopathic pulmonary fibrosis (IPF) affects subpleural lung, but is considered to spare small airways. Micro-CT studies demonstrated small airway reduction in end-stage IPF explanted lungs, raising questions about small airway involvement in early-stage disease. Endobronchial optical coherence tomography (EB-OCT) is a volumetric imaging modality that detects microscopic features from subpleural to proximal airways. We use EB-OCT to evaluate small airways in early IPF and control subjects in vivo. METHODS: EB-OCT was performed in 12 IPF and 5 control subjects (matched by age, sex, smoking-history, height, BMI). IPF subjects had early disease with mild restriction (FVC: 83.5% predicted), diagnosed per current guidelines and confirmed by surgical biopsy. EB-OCT volumetric imaging was acquired bronchoscopically in multiple, distinct, bilateral lung locations (total: 97 sites). IPF imaging sites were classified by severity into affected (all criteria for UIP present) and less affected (some but not all criteria for UIP present) sites. Bronchiole count and small airway stereology metrics were measured for each EB-OCT imaging site. RESULTS: Compared to control subjects (mean: 11.2 bronchioles/cm3; SD: 6.2), there was significant bronchiole reduction in IPF subjects (42% loss; mean: 6.5/cm3; SD: 3.4; p=0.0039), including in IPF affected (48% loss; mean: 5.8/cm3; SD: 2.8; p<0.00001) and IPF less affected (33% loss; mean: 7.5/cm3; SD: 4.1; p=0.024) sites. Stereology metrics showed IPF affected small airways were significantly larger and more distorted/irregular than in IPF less affected sites and control subjects. IPF less affected and control airways were statistically indistinguishable for all stereology parameters (p=0.36-1.0). CONCLUSION: EB-OCT demonstrated marked bronchiolar loss in early IPF (between 30 and 50%), even in areas minimally affected by disease, compared to matched controls. These findings support small airway disease as a feature of early IPF, providing novel insight into pathogenesis and potential therapeutic targets.

2.
Int J Mol Sci ; 25(6)2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38542430

ABSTRACT

To identify the vascular alteration by photodynamic therapy (PDT), the utilization of high-resolution, high-speed, and wide-field photoacoustic microscopy (PAM) has gained enormous interest. The rapid changes in vasculature during PDT treatment and monitoring of tumor tissue activation in the orthotopic pancreatic cancer model have received limited attention in previous studies. Here, a fully two-axes waterproof galvanometer scanner-based photoacoustic microscopy (WGS-PAM) system was developed for in vivo monitoring of dynamic variations in micro blood vessels due to PDT in an orthotopic pancreatic cancer mouse model. The photosensitizer (PS), Chlorin e6 (Ce6), was utilized to activate antitumor reactions in response to the irradiation of a 660 nm light source. Microvasculatures of angiogenesis tissue were visualized on a 40 mm2 area using the WGS-PAM system at 30 min intervals for 3 h after the PDT treatment. The decline in vascular intensity was observed at 24.5% along with a 32.4% reduction of the vascular density at 3 h post-PDT by the analysis of PAM images. The anti-vascularization effect was also identified with fluorescent imaging. Moreover, Ce6-PDT increased apoptotic and necrotic markers while decreasing vascular endothelial growth factor (VEGF) expression in MIA PaCa-2 and BxPC-3 pancreatic cancer cell lines. The approach of the WGS-PAM system shows the potential to investigate PDT effects on the mechanism of angiographic dynamics with high-resolution wide-field imaging modalities.


Subject(s)
Chlorophyllides , Pancreatic Neoplasms , Photochemotherapy , Porphyrins , Mice , Animals , Photochemotherapy/methods , Microscopy , Vascular Endothelial Growth Factor A/therapeutic use , Photosensitizing Agents/pharmacology , Photosensitizing Agents/therapeutic use , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/drug therapy , Pancreatic Neoplasms/pathology , Cell Line, Tumor , Porphyrins/pharmacology , Porphyrins/therapeutic use
3.
Biomed Opt Express ; 14(2): 627-638, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36874489

ABSTRACT

We present tunable image-mapping optical coherence tomography (TIM-OCT), which can provide optimized imaging performance for a given application by using a programmable phase-only spatial light modulator in a low-coherence full-field spectral-domain interferometer. The resultant system can provide either a high lateral resolution or a high axial resolution in a snapshot without moving parts. Alternatively, the system can achieve a high resolution along all dimensions through a multiple-shot acquisition. We evaluated TIM-OCT in imaging both standard targets and biological samples. Additionally, we demonstrated the integration of TIM-OCT with computational adaptive optics in correcting sample-induced optical aberrations.

4.
Photoacoustics ; 29: 100429, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36544533

ABSTRACT

Spatial sampling density and data size are important determinants of the imaging speed of photoacoustic microscopy (PAM). Therefore, undersampling methods that reduce the number of scanning points are typically adopted to enhance the imaging speed of PAM by increasing the scanning step size. Since undersampling methods sacrifice spatial sampling density, by considering the number of data points, data size, and the characteristics of PAM that provides three-dimensional (3D) volume data, in this study, we newly reported deep learning-based fully reconstructing the undersampled 3D PAM data. The results of quantitative analyses demonstrate that the proposed method exhibits robustness and outperforms interpolation-based reconstruction methods at various undersampling ratios, enhancing the PAM system performance with 80-times faster-imaging speed and 800-times lower data size. The proposed method is demonstrated to be the closest model that can be used under experimental conditions, effectively shortening the imaging time with significantly reduced data size for processing.

5.
Photoacoustics ; 27: 100376, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35734368

ABSTRACT

The ischemic stroke animal model evaluates the efficacy of reperfusion and neuroprotective strategies for ischemic injuries. Various conventional methods have been reported to induce the ischemic models; however, controlling specific neurological deficits, mortality rates, and the extent of the infarction is difficult as the size of the affected region is not precisely controlled. In this paper, we report a single laser-based localized target ischemic stroke model development method by simultaneous vessel monitoring and photothrombosis induction using photoacoustic microscopy (PAM), which has minimized the infarct size at precise location with high reproducibility. The proposed method has significantly reduced the infarcted region by illuminating the precise localization. The reproducibility and validity of suggested method have been demonstrated through repeated experiments and histological analyses. These results demonstrate that our method can provide the ischemic stroke model closest to the clinical pathology for brain ischemia research from inducement, occurrence mechanisms to the recovery process.

6.
Biomed Opt Express ; 13(12): 6457-6469, 2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36589580

ABSTRACT

We present tunable image projection spectrometry (TIPS), a Fourier-domain line-scan spectral imager with a tunable compression ratio. Compared to state-of-the-art spatial-domain pushbroom hyperspectral cameras, TIPS requires much fewer measurements and provides a higher light throughput. Using a rotating Dove prism and a cylindrical field lens, TIPS scans an input scene in the Fourier domain and captures a subset of multi-angled one-dimensional (1D) en face projections of the input scene, allowing a tailored data compression ratio for a given scene. We demonstrate the spectral imaging capability of TIPS with a hematoxylin and eosin (H&E) stained pathology slide. Moreover, we showed the spectral information obtained can be further converted to depths when combining TIPS with a low-coherence full-field spectral-domain interferometer.

7.
Sensors (Basel) ; 21(14)2021 Jul 07.
Article in English | MEDLINE | ID: mdl-34300410

ABSTRACT

The aim of this study was to quantitatively assess the residual adhesive on orthodontic ceramic bracket-removed dental surface. In orthodontic process, ceramic bracket was repeated debonding physically, then the adhesive remained on the dental surface. The residual adhesive caused a lack of adhesive strength between dental and ceramic bracket. Since commonly used adhesive in orthodontics is translucent, residual adhesive is hard to be detected with conventional microscopes. Therefore, 1310 nm center wavelength swept-source OCT system based on laboratory customized image processing algorithm was used for the precise detection of residual adhesive on tooth surface. The algorithm separates residual adhesive from dental surface by comparing the height of adjacent B-scan images, while providing color-scaled images emphasizing the thickness information of residual adhesive. Finally, the acquired results were compared with microscopic and adhesive remnant index scoring gold standards, while the comparison confirmed the potential merits and the improvements of the proposed method over gold standards.


Subject(s)
Adhesives , Orthodontic Brackets , Algorithms , Ceramics , Materials Testing , Surface Properties , Tomography, Optical Coherence
8.
Sensors (Basel) ; 20(7)2020 Apr 07.
Article in English | MEDLINE | ID: mdl-32272646

ABSTRACT

Depth-visualizing sensitivity can be degraded due to imperfect optical alignment and non-equidistant distribution of optical signals in the pixel array, which requires a measurement of the re-sampling process. To enhance this depth-visualizing sensitivity, reference and sample arm-channeled spectra corresponding to different depths using mirrors were obtained to calibrate the spectrum sampling prior to Fourier transformation. During the process, eight interferogram patterns corresponding to point spread function (PSF) signals at eight optical path length differences were acquired. To calibrate the spectrum, generated intensity points of the original interferogram were re-indexed towards a maximum intensity range, and these interferogram re-indexing points were employed to generate a new lookup table. The entire software-based process consists of eight consecutive steps. Experimental results revealed that the proposed method can achieve images with a high depth-visualizing sensitivity. Furthermore, the results validate the proposed method as a rapidly performable spectral calibration technique, and the real-time images acquired using our technique confirm the simplicity and applicability of the method to existing optical coherence tomography (OCT) systems. The sensitivity roll-off prior to the spectral calibration was measured as 28 dB and it was halved after the calibration process.

9.
Opt Lett ; 45(4): 865-868, 2020 Feb 15.
Article in English | MEDLINE | ID: mdl-32058491

ABSTRACT

A large field-of-view and fast scanning of photoacoustic microscopy (PAM) relatively have been difficult to obtain due to the water-drowned structure of the system for the transmission of ultrasonic signals. Researchers have widely studied the achievement of a waterproof scanner for dynamic biological applications with a high-resolution and high signal-to-noise ratio. This Letter reports a novel, to the best of our knowledge, waterproof galvanometer scanner-based PAM system with a successfully attainable ${9.0}\;{\rm mm} \times {14.5}\;{\rm mm}$9.0mm×14.5mm scan region, amplitude scan rate of 40 kHz, and spatial resolution of 4.9 µm. The in vivo characterization of a mouse brain in intact-skull microvascular visualization demonstrated its capability in biomedical imaging and is anticipated to be an effective technique for various preclinical and clinical studies.


Subject(s)
Electric Conductivity , Mechanical Phenomena , Microscopy/instrumentation , Photoacoustic Techniques/instrumentation , Signal-To-Noise Ratio , Animals , Brain/diagnostic imaging , Mice , Water
10.
J Biophotonics ; 13(2): e201900202, 2020 02.
Article in English | MEDLINE | ID: mdl-31670908

ABSTRACT

An elevated relative moisture in the external ear canal and middle ear cavity may predispose to chronic otorrhea and related infections along with abnormal tympanic membrane (TM) vibration patterns. Therefore, phase shift-resolved optical Doppler vibrography (ODV) was used for vibration assessments of moisture influenced cadaveric TM. ODV was applied to generate time resolved cross-sectional and volumetric vibrographs of a cadaveric TM, driven acoustically at several frequencies. In order to analyze the effect of moisture on TM, homogenous moisture conditions were provided by soaking the cadaveric TM specimens in 1× phosphate buffer saline with a pH of 7.4. The TM specimen was exposed to a rapidly switchable frequency generator during the ODV image acquisition. The experiment was conducted for 3 hours and the cadaveric TM was exposed to each frequency with an interval of 30 minutes. Acquired phase shift-resolved ODV assessments revealed a depth dependent vibration tendency between the applied frequencies, along with a decline in the moisture level of the cadaveric TM specimen. Thus, the ODV method can aid our understanding of sound conduction in the middle ear, thus supporting the diagnosis of TM diseases.


Subject(s)
Ear, Middle , Tympanic Membrane , Cadaver , Cross-Sectional Studies , Ear, Middle/diagnostic imaging , Humans , Tympanic Membrane/diagnostic imaging , Vibration
11.
Sensors (Basel) ; 20(1)2019 Dec 20.
Article in English | MEDLINE | ID: mdl-31877652

ABSTRACT

Non-invasive characterization of micro-vibrations in the tympanic membrane (TM) excited by external sound waves is considered as a promising and essential diagnosis in modern otolaryngology. To verify the possibility of measuring and discriminating the vibrating pattern of TM, here we describe a micro-vibration measurement method of latex membrane resembling the TM. The measurements are obtained with an externally generated audio stimuli of 2.0, 2.2, 2.8, 3.1 and 3.2 kHz, and their respective vibrations based tomographic, volumetric and quantitative evaluations were acquired using optical Doppler tomography (ODT). The micro oscillations and structural changes which occurred due to diverse frequencies are measured with sufficient accuracy using a highly sensitive ODT system implied phase subtraction method. The obtained results demonstrated the capability of measuring and analyzing the complex varying micro-vibration of the membrane according to implied sound frequency.

12.
J Biophotonics ; 12(11): e201900098, 2019 11.
Article in English | MEDLINE | ID: mdl-31240872

ABSTRACT

Corneal transplantation by full-thickness penetrating keratoplasty with human donor tissue is a widely accepted treatment for damaged or diseased corneas. Although corneal transplantation has a high success rate, a shortage of high-quality donor tissue is a considerable limitation. Therefore, bioengineered corneas could be an effective solution for this limitation, and a decellularized extracellular matrix comprises a promising scaffold for their fabrication. In this study, three-dimensional bioprinted decellularized collagen sheets were implanted into the stromal layer of the cornea of five rabbits. We performed in vivo noninvasive monitoring of the rabbit corneas using swept-source optical coherence tomography (OCT) after implanting the collagen sheets. Anterior segment OCT images and averaged amplitude-scans were acquired biweekly to monitor corneal thickness after implantation for 1 month. The averaged cornea thickness in the control images was 430.3 ± 5.9 µm, while the averaged thickness after corneal implantation was 598.5 ± 11.8 µm and 564.5 ± 12.5 µm at 2 and 4 weeks, respectively. The corneal thickness reduction of 34 µm confirmed the biocompatibility through the image analysis of the depth-intensity profile base. Moreover, hematoxylin and eosin staining supported the biocompatibility evaluation of the bioprinted decellularized collagen sheet implantation. Hence, the developed bioprinted decellularized collagen sheets could become an alternative solution to human corneal donor tissue, and the proposed image analysis procedure could be beneficial to confirm the success of the surgery.


Subject(s)
Bioprinting , Collagen , Cornea/cytology , Cornea/diagnostic imaging , Materials Testing , Prostheses and Implants , Tomography, Optical Coherence , Animals , Rabbits , Tissue Engineering , Tissue Scaffolds/chemistry
13.
Sci Rep ; 8(1): 17432, 2018 11 27.
Article in English | MEDLINE | ID: mdl-30479360

ABSTRACT

Significant technical and optical advances are required for intraoperative optical coherence tomography (OCT) to be utilized during otological surgeries. Integrating OCT with surgical microscopy makes it possible to evaluate soft tissue in real-time and at a high resolution. Herein, we describe an augmented-reality, intraoperative OCT/microscope system with an extended working distance of 280 mm, providing more space for surgical manipulation than conventional techniques. We initially performed ex vivo experiments to evaluate system performance. In addition, we validated the system by performing preliminary clinical assessments of tympanomastoidectomy outcomes in six patients with chronic otitis media. The system evaluated residual inflammation in the region-of-interest of the mastoid bone. Most importantly, the system intraoperatively revealed the connection between the graft and the remnant tympanic membrane. The extended working distance allows otological surgeons to evaluate the status of both the mastoid bone and tympanic membrane during manipulation, affording full intraoperative imaging.


Subject(s)
Mastoidectomy/methods , Microsurgery/methods , Monitoring, Intraoperative/methods , Otitis/surgery , Tomography, Optical Coherence/methods , Tympanoplasty/methods , Animals , Guinea Pigs , Humans , Male , Mastoid/surgery , Mastoidectomy/instrumentation , Microsurgery/instrumentation , Monitoring, Intraoperative/instrumentation , Tomography, Optical Coherence/instrumentation , Tympanic Membrane/surgery , Tympanoplasty/instrumentation
14.
Sensors (Basel) ; 17(9)2017 Aug 24.
Article in English | MEDLINE | ID: mdl-28837058

ABSTRACT

A handheld line information reader and a line information generator were developed for the efficient management of optical communication lines. The line information reader consists of a photo diode, trans-impedance amplifier, voltage amplifier, microcontroller unit, display panel, and communication modules. The line information generator consists of a laser diode, laser driving circuits, microcontroller unit, and communication modules. The line information reader can detect the optical radiation field of the test line by bending the optical fiber. To enhance the sensitivity of the line information reader, an additional lens was used with a focal length of 4.51 mm. Moreover, the simulation results obtained through BeamPROP® software from Synopsys, Inc. demonstrated a stronger optical radiation field of the fiber due to a longer transmission wavelength and larger bending angle of the fiber. Therefore, the developed devices can be considered as useful tools for the efficient management of optical communication lines.

15.
J Biomed Opt ; 21(8): 081204, 2016 Aug.
Article in English | MEDLINE | ID: mdl-26979048

ABSTRACT

The aim of this study was to analyze the effectiveness of decalcification using ethylenediaminetetraacetic acid (EDTA) as an optical clearing method to enhance the depth visibility of internal soft tissues of cochlea. Ex vivo mouse and guinea pig cochlea samples were soaked in EDTA solutions for decalcification, and swept source optical coherence tomography (OCT) was used as imaging modality to monitor the decalcified samples consecutively. The monitored noninvasive cross-sectional images showed that the mouse and guinea pig cochlea samples had to be decalcified for subsequent 7 and 14 days, respectively, to obtain the optimal optical clearing results. Using this method, difficulties in imaging of internal cochlea microstructures of mice could be evaded. The obtained results verified that the depth visibility of the decalcified ex vivo samples was enhanced.


Subject(s)
Cochlea/chemistry , Cochlea/diagnostic imaging , Edetic Acid/chemistry , Histological Techniques/methods , Tomography, Optical Coherence/methods , Animals , Guinea Pigs , Image Processing, Computer-Assisted , Male , Mice , Mice, Inbred ICR
SELECTION OF CITATIONS
SEARCH DETAIL
...