Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Urol ; 24(1): 139, 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38965501

ABSTRACT

BACKGROUND: An intravesical gas explosion is a rare complication of transurethral resection of the prostate (TURP). It was first reported in English literature in 1926, and up to 2022 were only forty-one cases. Injury from an intravesical gas explosion, in the most severe cases appearing as extraperitoneal or intraperitoneal bladder rupture needed emergent repair surgery. CASE PRESENTATION: We present a case of a 75-year-old man who suffered an intravesical gas explosion during TURP. The patient underwent an emergent exploratory laparotomy for bladder repair and was transferred to the intensive care unit for further observation and treatment. Under the medical team's care for up to sixty days, the patient recovered smoothly without clinical sequelae. CONCLUSIONS: This case report presents an example of a rare complication of intravesical gas explosion during TURP, utilizing root cause analysis (RCA) to comprehend causal relationships and team strategies and tools to improve performance and patient safety (TeamSTEPPS) method delivers four teamwork skills that can be utilized during surgery and five recommendations to avoid gas explosions during TURP to prevent the recurrence of medical errors. In modern healthcare systems, promoting patient safety is crucial. Once complications appear, RCA and TeamSTEPPS are helpful means to support the healthcare team reflect and improve as a team.


Subject(s)
Explosions , Root Cause Analysis , Transurethral Resection of Prostate , Urinary Bladder , Humans , Male , Aged , Transurethral Resection of Prostate/adverse effects , Urinary Bladder/surgery , Urinary Bladder/injuries , Gases , Patient Care Team , Intraoperative Complications/etiology
2.
IEEE Trans Neural Syst Rehabil Eng ; 24(11): 1199-1209, 2016 11.
Article in English | MEDLINE | ID: mdl-26929055

ABSTRACT

This paper presents an assistive control system with a special kinematic structure of an upper limb rehabilitation robot embedded with force/torque sensors. A dynamic human model integrated with sensing torque is used to simulate human interaction under three rehabilitation modes: active mode, assistive mode, and passive mode. The hereby proposed rehabilitation robot, called NTUH-ARM, provides 7 degree-of- freedom (DOF) motion and runs subject to an inherent mapping between the 7 DOFs of the robot arm and the 4 DOFs of the human arm. The Lyapunov theory is used to analyze the stability of the proposed controller design. Clinical trials have been conducted with six patients, one of which acts as a control. The results of these experiments are positive and STREAM assessment by physical therapists also reveals promising results.


Subject(s)
Biofeedback, Psychology/instrumentation , Models, Biological , Motion Therapy, Continuous Passive/instrumentation , Movement Disorders/rehabilitation , Robotics/instrumentation , Therapy, Computer-Assisted/instrumentation , Arm , Biofeedback, Psychology/methods , Equipment Design , Equipment Failure Analysis , Exoskeleton Device , Humans , Motion Therapy, Continuous Passive/methods , Neurological Rehabilitation/instrumentation , Neurological Rehabilitation/methods , Robotics/methods , Therapy, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...