Sci Rep ; 14(1): 11539, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773167

ABSTRACT

Blooming artifacts caused by calcifications appearing on computed tomography (CT) images lead to an underestimation of the coronary artery lumen size, and higher X-ray energy levels are suggested to reduce the blooming artifacts with subjective visual assessment. This study aimed to evaluate the effect of higher X-ray energy levels on the quantitative measurement of adjacent pixels affected by calcification using CT images. In this two-part study, CT images were acquired from dual-energy CT scanners by changing the X-ray energy levels such as kilovoltage peak (kVp) and kilo-electron volts (keV). Adjacent pixels affected by calcification were measured using the brightened length, excluding the actual calcified length, as determined by the full width at third maximum. In a separate clinical study, the adjacent affected pixels associated with 23 calcifications across 10 patients were measured using the same method as that used in the phantom study. Phantom and clinical studies showed that the change in kVp (field of view [FOV] 300 mm: p = 0.167, 0.494, and 0.861 for vendors 1, 2, and 3, respectively) and keV levels (p = 0.178 for vendor 2) failed to reduce the adjacent pixels affected by calcification, respectively. Moreover, the change in keV levels showed different aspects of adjacent pixels affected by calcification in the phantom study (FOV 300 mm: no significant difference [p = 0.191], increase [p < 0.001], and decrease [p < 0.001] for vendors 1, 2, and 3, respectively). Quantitative measurements revealed no significant relationship between higher X-ray energy levels and the adjacent pixels affected by calcification.


Subject(s)
Artifacts , Calcinosis , Phantoms, Imaging , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Calcinosis/diagnostic imaging , Male , Female , Middle Aged , Aged , Coronary Vessels/diagnostic imaging , X-Rays
2.
J Korean Soc Radiol ; 85(2): 258-269, 2024 Mar.
Article in Korean | MEDLINE | ID: mdl-38617849

ABSTRACT

Treatment of patients with coronary artery disease commonly involves the use of balloon-expandable stent placements, currently recognized as the most prevalent approach for coronary artery revascularization. Nevertheless, the occurrence of restenosis remains a significant complication following percutaneous coronary interventions. The diagnostic role of coronary CT angiography (CCTA) in detecting stent restenosis has limitations primarily attributable to challenges in accurately discerning the lumen, due to issues such as blooming and motion artifacts. As a result, many cases often necessitate a transition to conventional coronary angiography. However, recent advancements in CT technology have led to notable improvements in both sensitivity and specificity, underscoring the growing significance of CCTA as a diagnostic tool. The consistent reporting of high negative predictive value is particularly noteworthy. This review aims to explore the historical context, current status, and recent trends in diagnosing coronary artery stent restenosis using CCTA.

3.
Article in English | MEDLINE | ID: mdl-38634943

ABSTRACT

Automatic segmentation of the coronary artery using coronary computed tomography angiography (CCTA) images can facilitate several analyses related to coronary artery disease (CAD). Accurate segmentation of the lumen or plaque region is one of the most important factors. This study aimed to analyze the performance of the coronary artery segmentation of a software platform with a deep learning-based location-adaptive threshold method (DL-LATM) against commercially available software platforms using CCTA. The dataset from intravascular ultrasound (IVUS) of 26 vessel segments from 19 patients was used as the gold standard to evaluate the performance of each software platform. Statistical analyses (Pearson correlation coefficient [PCC], intraclass correlation coefficient [ICC], and Bland-Altman plot) were conducted for the lumen or plaque parameters by comparing the dataset of each software platform with IVUS. The software platform with DL-LATM showed the bias closest to zero for detecting lumen volume (mean difference = -9.1 mm3, 95% confidence interval [CI] = -18.6 to 0.4 mm3) or area (mean difference = -0.72 mm2, 95% CI = -0.80 to -0.64 mm2) with the highest PCC and ICC. Moreover, lumen or plaque area in the stenotic region was analyzed. The software platform with DL-LATM showed the bias closest to zero for detecting lumen (mean difference = -0.07 mm2, 95% CI = -0.16 to 0.02 mm2) or plaque area (mean difference = 1.70 mm2, 95% CI = 1.37 to 2.03 mm2) in the stenotic region with significantly higher correlation coefficient than other commercially available software platforms (p < 0.001). The result shows that the software platform with DL-LATM has the potential to serve as an aiding system for CAD evaluation.

4.
Korean J Radiol ; 25(4): 331-342, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38528691

ABSTRACT

The Asian Society of Cardiovascular Imaging-Practical Tutorial (ASCI-PT) is an instructional initiative of the ASCI School designed to enhance educational standards. In 2021, the ASCI-PT was convened with the goal of formulating a consensus statement on the assessment of coronary stenosis and coronary plaque using coronary CT angiography (CCTA). Nineteen experts from four countries conducted thorough reviews of current guidelines and deliberated on eight key issues to refine the process and improve the clarity of reporting CCTA findings. The experts engaged in both online and on-site sessions to establish a unified agreement. This document presents a summary of the ASCI-PT 2021 deliberations and offers a comprehensive consensus statement on the evaluation of coronary stenosis and coronary plaque in CCTA.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Plaque, Atherosclerotic , Humans , Computed Tomography Angiography , Predictive Value of Tests , Coronary Stenosis/diagnostic imaging , Plaque, Atherosclerotic/diagnostic imaging , Coronary Angiography
5.
Article in English | MEDLINE | ID: mdl-38092064

ABSTRACT

BACKGROUND: This study was conducted to evaluate whether myocardial viability assessed with cardiac magnetic resonance (CMR) affected long-term clinical outcomes after coronary artery bypass grafting (CABG) in patients with ischemic cardiomyopathy (ICMP). METHODS: Preoperative CMR with late gadolinium enhancement (LGE) was performed in 103 patients (64.9 ± 10.1 years, male:female = 82:21) with 3-vessel disease and left ventricular dysfunction (ejection fraction ≤ 0.35). Transmural extent of LGE was evaluated on a 16-segment model, and transmurality was graded on a 5-point scale: grades-0, absence; 1, 1 to 25%; 2, 26 to 50%; 3, 51 to 75%; 4, 76 to 100%. Median follow-up duration was 65.5 months (interquartile range = 27.5-95.3 months). Primary endpoint was the composite of all-cause mortality or hospitalization for congestive heart failure. RESULTS: Operative mortality was 1.9%. During the follow-up, all-cause mortality and readmission for congestive heart failure occurred in 29 and 8 patients, respectively. The cumulative incidence of the primary endpoint was 31.3 and 46.8% at 5 and 10 years, respectively. Multivariable analysis demonstrated that the number of segments with LGE grade 4 was a significant risk factor (hazard ratio 1.42, 95% confidence interval 1.10-1.83, p = 0.007) for the primary endpoint among the variables assessed by CMR. Other risk factors included age, dialysis, chronic obstructive pulmonary disease, and EuroSCORE II. CONCLUSION: The number of myocardial segments with transmurality of LGE >75% might be a prognostic factor associated with the composite of all-cause mortality or hospitalization for congestive heart failure after CABG in patients with 3-vessel disease and ICMP.

6.
Eur Radiol ; 2023 Dec 19.
Article in English | MEDLINE | ID: mdl-38114847

ABSTRACT

OBJECTIVES: To compare cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) for the quantitative assessment of the left ventricular (LV) trabeculated layer in patients with suspected noncompaction cardiomyopathy (NCCM). MATERIALS AND METHODS: Subjects with LV excessive trabeculation who underwent both CMR and CCT imaging as part of the prospective international multicenter NONCOMPACT clinical study were included. For each subject, short-axis CCT and CMR slices were matched. Four quantitative metrics were estimated: 1D noncompacted-to-compacted ratio (NCC), trabecular-to-myocardial area ratio (TMA), trabecular-to-endocardial cavity area ratio (TCA), and trabecular-to-myocardial volume ratio (TMV). In 20 subjects, end-diastolic and mid-diastolic CCT images were compared for the quantification of the trabeculated layer. Relationships between the metrics were investigated using linear regression models and Bland-Altman analyses. RESULTS: Forty-eight subjects (49.9 ± 12.8 years; 28 female) were included in this study. NCC was moderately correlated (r = 0.62), TMA and TMV were strongly correlated (r = 0.78 and 0.78), and TCA had excellent correlation (r = 0.92) between CMR and CCT, with an underestimation bias from CCT of 0.3 units, and 5.1, 4.8, and 5.4 percent-points for the 4 metrics, respectively. TMA, TCA, and TMV had excellent correlations (r = 0.93, 0.96, 0.94) and low biases (- 3.8, 0.8, - 3.8 percent-points) between the end-diastolic and mid-diastolic CCT images. CONCLUSIONS: TMA, TCA, and TMV metrics of the LV trabeculated layer in patients with suspected NCCM demonstrated high concordance between CCT and CMR images. TMA and TCA were highly reproducible and demonstrated minimal differences between mid-diastolic and end-diastolic CCT images. CLINICAL RELEVANCE STATEMENT: The results indicate similarity of CCT to CMR for quantifying the LV trabeculated layer, and the small differences in quantification between end-diastole and mid-diastole demonstrate the potential for quantifying the LV trabeculated layer from clinically performed coronary CT angiograms. KEY POINTS: • Data on cardiac CT for quantifying the left ventricular trabeculated layer are limited. • Cardiac CT yielded highly reproducible metrics of the left ventricular trabeculated layer that correlated well with metrics defined by cardiac MR. • Cardiac CT appears to be equivalent to cardiac MR for the quantification of the left ventricular trabeculated layer.

7.
Radiology ; 309(1): e222467, 2023 10.
Article in English | MEDLINE | ID: mdl-37906013

ABSTRACT

Background The recurrence of hypersensitivity reaction (HSR) to low-osmolar iodinated contrast media (LOCM) remains challenging despite premedication and substitution of the LOCM. Purpose To determine the optimal practical preventive strategy for LOCM substitution in patients with a history of prior immediate HSR to LOCM. Materials and Methods In a retrospective study, patients with an immediate HSR to LOCM before February 2020 and who underwent subsequent exposure to LOCM until March 2021 were enrolled in five tertiary referral hospitals in South Korea. The association of recurrence of an HSR after subsequent LOCM exposures was assessed using multivariate general estimating equation analysis according to age, sex, the severity of the index HSR, premedication, and substituting LOCM based on common carbamoyl side chains, including the N-(2,3-dihydroxypropyl)-carbamoyl and N-(2,3-dihydroxypropyl)-N-methyl-carbamoyl moieties. Results The evaluation included 3800 subsequent LOCM exposures in 1066 patients (mean age, 56.2 years ± 13.5 [SD]; 567 [53%] female and 499 [47%] male patients). The general estimating equation analysis, using 1:1 propensity score matched data for age, sex, HSR severity, and LOCM selection, showed that premedication with corticosteroids significantly reduced recurrent HSR (odds ratio [OR], 0.72; 95% CI: 0.52, 1.00; P = .049). The change to another LOCM with a common side chain had a similar recurrence rate as using the same LOCM (OR, 0.98; 95% CI: 0.64, 1.50; P = .93), whereas the use of a different LOCM without a common side chain significantly lowered HSR recurrence (OR, 0.51; 95% CI: 0.37, 0.69; P < .001) in multivariate general estimating equation analysis. Substitution of an LOCM without a common side chain was effective regardless of the index HSR severity but was more pronounced in moderate-to-severe reactions (OR, 0.30; 95% CI: 0.16, 0.55; P < .001). Conclusion For patients with a previous immediate HSR of any severity to LOCM, alternative LOCM without a common carbamoyl side chain reduced recurrent HSR during subsequent exposures. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by McDonald in this issue.


Subject(s)
Hypersensitivity, Immediate , Hypersensitivity , Humans , Female , Male , Middle Aged , Contrast Media/adverse effects , Retrospective Studies , Multivariate Analysis
8.
J Cardiovasc Dev Dis ; 10(4)2023 Mar 28.
Article in English | MEDLINE | ID: mdl-37103022

ABSTRACT

BACKGROUND: We evaluated the accuracy of a deep learning-based automated quantification algorithm for coronary artery calcium (CAC) based on enhanced ECG-gated coronary CT angiography (CCTA) with dedicated coronary calcium scoring CT (CSCT) as the reference. METHODS: This retrospective study included 315 patients who underwent CSCT and CCTA on the same day, with 200 in the internal and 115 in the external validation sets. The calcium volume and Agatston scores were calculated using both the automated algorithm in CCTA and the conventional method in CSCT. The time required for computing calcium scores using the automated algorithm was also evaluated. RESULTS: Our automated algorithm extracted CACs in less than five minutes on average with a failure rate of 1.3%. The volume and Agatston scores by the model showed high agreement with those from CSCT with concordance correlation coefficients of 0.90-0.97 for the internal and 0.76-0.94 for the external. The accuracy for classification was 92% with a 0.94 weighted kappa for the internal and 86% with a 0.91 weighted kappa for the external set. CONCLUSIONS: The deep learning-based and fully automated algorithm efficiently extracted CACs from CCTA and reliably assigned categorical classification for Agatston scores without additional radiation exposure.

9.
Eur Radiol ; 33(6): 3839-3847, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36520181

ABSTRACT

OBJECTIVE: To investigate performance of 1-mm, sharp kernel, low-dose chest computed tomography (LDCT) for coronary artery calcium scoring (CACS) using deep learning (DL)-based denoising technique. METHODS: This retrospective, intra-individual comparative study consisted of four image datasets of 131 participants who underwent LDCT and calcium CT on the same day between January and February 2020; 1-mm LDCT with DL, 1-mm LDCT with iterative reconstruction (IR), 3-mm LDCT, and calcium CT. CACS from calcium CT were considered as reference and CACS were categorized as 0, 1-10, 11-100, 101-400, and > 400. We compared CACS from LDCTs with that from calcium CT. RESULTS: Mean CACS was 104.8 ± 249.1 and proportion of positive CACS was 45% (59/131). CACS from LDCT images tended to be underestimated than those from calcium CT: 1-mm LDCT with DL (93.5 ± 249.6, p = 0.002), 1-mm LDCT with IR (94.7 ± 249.9, p < 0.001), and 3-mm LDCT (90.3 ± 245.3, p = 0.004). All LDCT datasets showed excellent agreement with calcium CT: intraclass correlation coefficient (ICC) = 0.961 (95% confidence interval (CI), 0.945-0.972) for DL, 0.969 (95% CI, 0.956-0.978) for IR, and 0.952 (95% CI, 0.932-0.966) for 3-mm LDCT; weighted kappa for CACS classification, 0.930 (95% CI, 0.893-0.966) for 1-mm LDCT with DL, 0.908 (95% CI, 0.866-0.950) for 1-mm LDCT with IR, and 0.846 (95% CI, 0.780-0.912) for 3-mm LDCT. The accuracy of CACS classification of 1-mm LDCT with DL (90%) tended to be better than 1-mm LDCT with IR (87%) and 3-mm LDCT (84.7%) (p = 0.10). CONCLUSION: DL-based noise reduction algorithm can offer reliable calcium scores in 1-mm LDCT reconstructed with sharp kernel. KEY POINTS: • Deep learning (DL)-based noise reduction enables calcium scoring at 1-mm, sharp kernel reconstructed low-dose chest CT (LDCT). • Both iterative reconstruction and DL-based noise reduction underestimated calcium score, but agreement were excellent with those from calcium CT. • Accuracy of categorical classification of calcium scoring tended to be highest in 1-mm LDCT with DL compared to 1-mm LDCT with IR and 3-mm LDCT (90%, 87%, and 84.7%, p = 0.10).


Subject(s)
Coronary Artery Disease , Deep Learning , Humans , Coronary Artery Disease/diagnostic imaging , Calcium , Retrospective Studies , Tomography, X-Ray Computed/methods , Algorithms , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods
10.
Taehan Yongsang Uihakhoe Chi ; 83(1): 3-27, 2022 Jan.
Article in Korean | MEDLINE | ID: mdl-36237355

ABSTRACT

Cardiac CT has been proven to provide diagnostic and prognostic evaluation of coronary artery disease for cardiovascular risk stratification and treatment decision-making based on rapid technological development and various research evidence. Coronary CT angiography has emerged as a gateway test for coronary artery disease that can reduce invasive angiography due to its high negative predictive value, but the diagnostic specificity is relatively low. However, coronary CT angiography is likely to overcome its limitations through functional evaluation to identify the hemodynamic significance of coronary artery disease by analyzing myocardial perfusion and fractional flow reserve through cardiac CT. Recently, studies have been actively conducted to incorporate artificial intelligence to make this more objective and reproducible. In this review, functional imaging techniques of cardiac computerized tomography are explored.

11.
JTCVS Tech ; 12: 132-142, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35403031

ABSTRACT

Background: Three-dimensional (3D) printed models are widely accepted for use in training of various surgical procedures for congenital heart disease; however, their physical properties have been considered suboptimum for procedures. We created silicone molded models produced using a novel "parting and assembly" strategy and compared their suitability for hands-on training with that of conventional 3D printed models. Methods: Computed tomography imaging data from 2 patients with transposition of the great arteries were used. The heart was divided into multiple parts (atria, ventricles, great arteries, coronary arteries, and valves), and molds of each part were created. The parts reproduced by silicone molding were assembled using an adhesive agent. In an online course, 2 silicone molded models and 1 3D printed model were used for training of 34 surgeons. A questionnaire was distributed to these surgeons aimed at assessing the suitability of the models for the arterial switch operation (ASO). Results: The silicone molded models showed excellent anatomic detail, high elasticity, and high resistance to tearing. The cost per model, based on the production of 50 models, was slightly higher for the silicone molded models compared with the 3D printed models. All 26 surgeons who completed the questionnaire reported that the silicone molded models provided sufficient anatomic information, but only 19% said the same for the 3D printed models. All surgeons also considered the silicone models to be realistic when passing a needle, cutting vessels, suturing, and excision of the coronary buttons, as opposed to <46% for the 3D printed models. Conclusions: Silicone molding of models for the ASO is feasible by applying a "parting and assembly" strategy. Silicone molded models provide excellent physical properties that are far superior to those of 3D printed models for surgical simulation.

12.
Korean J Radiol ; 23(3): 298-307, 2022 03.
Article in English | MEDLINE | ID: mdl-35213094

ABSTRACT

OBJECTIVE: This study aimed to evaluate the effect of implementing the consensus statement from the Asian Society of Cardiovascular Imaging-Practical Tutorial 2020 (ASCI-PT 2020) on the reliability of cardiac MR with late gadolinium enhancement (CMR-LGE) myocardial viability scoring between observers in the context of ischemic cardiomyopathy. MATERIALS AND METHODS: A total of 17 cardiovascular imaging experts from five different countries evaluated CMR obtained in 26 patients (male:female, 23:3; median age [interquartile range], 55.5 years [50-61.8]) with ischemic cardiomyopathy. For LGE scoring, based on the 17 segments, the extent of LGE in each segment was graded using a five-point scoring system ranging from 0 to 4 before and after exposure according to the consensus statement. All scoring was performed via web-based review. Scores for slices, vascular territories, and total scores were obtained as the sum of the relevant segmental scores. Interobserver reliability for segment scores was assessed using Fleiss' kappa, while the intraclass correlation coefficient (ICC) was used for slice score, vascular territory score, and total score. Inter-observer agreement was assessed using the limits of agreement from the mean (LoA). RESULTS: Interobserver reliability (Fleiss' kappa) in each segment ranged 0.242-0.662 before the consensus and increased to 0.301-0.774 after the consensus. The interobserver reliability (ICC) for each slice, each vascular territory, and total score increased after the consensus (slice, 0.728-0.805 and 0.849-0.884; vascular territory, 0.756-0.902 and 0.852-0.941; total score, 0.847 and 0.913, before and after implementing the consensus statement, respectively. Interobserver agreement in scoring also improved with the implementation of the consensus for all slices, vascular territories, and total score. The LoA for the total score narrowed from ± 10.36 points to ± 7.12 points. CONCLUSION: The interobserver reliability and agreement for CMR-LGE scoring for ischemic cardiomyopathy improved when following guidance from the ASCI-PT 2020 consensus statement.


Subject(s)
Cardiomyopathies , Myocardial Ischemia , Cardiomyopathies/diagnostic imaging , Contrast Media , Female , Gadolinium , Heart Ventricles , Humans , Magnetic Resonance Imaging, Cine/methods , Male , Middle Aged , Myocardial Ischemia/diagnostic imaging , Reproducibility of Results
13.
Eur Heart J Cardiovasc Imaging ; 23(8): 1108-1116, 2022 07 21.
Article in English | MEDLINE | ID: mdl-34542591

ABSTRACT

AIMS: We investigated the prognostic role of left ventricular global longitudinal strain (LV-GLS) and its incremental value to established risk models for predicting sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM). METHODS AND RESULTS: LV-GLS was measured with vendor-independent software at a core laboratory in a cohort of 835 patients with HCM (aged 56.3 ± 12.2 years) followed-up for a median of 6.4 years. The primary endpoint was SCD events, including appropriate defibrillator therapy, within 5 years after the initial evaluation. The secondary endpoint was a composite of SCD events, heart failure admission, heart transplantation, and all-cause mortality. Twenty (2.4%) and 85 (10.2%) patients experienced the primary and secondary endpoints, respectively. Lower absolute LV-GLS quartiles, especially those worse than the median (-15.0%), were associated with progressively higher SCD event rates (P = 0.004). LV-GLS was associated with an increased risk for the primary endpoint, independent of the LV ejection fraction, apical aneurysm, and 2014 European Society of Cardiology (ESC) risk score [adjusted hazard ratio (aHR) 1.14, 95% confidence interval (CI) 1.02-1.28] or 2011 American College of Cardiology/American Heart Association (ACC/AHA) risk factors (aHR 1.18, 95% CI 1.05-1.32). LV-GLS was also associated with a higher risk for the composite secondary endpoint (aHR 1.06, 95% CI 1.01-1.12). The addition of LV-GLS enhanced the performance of the ESC risk score (C-statistic 0.756 vs. 0.842, P = 0.007) and the 2011 ACC/AHA risk factor strategy (C-statistic 0.743 vs. 0.814, P = 0.007) for predicting SCD. CONCLUSION: LV-GLS is an important prognosticator in patients with HCM and provides additional information to established risk stratification strategies for predicting SCD.


Subject(s)
Cardiomyopathy, Hypertrophic , Death, Sudden, Cardiac , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Humans , Prognosis , Risk Assessment , Risk Factors , Stroke Volume , Ventricular Function, Left
14.
Eur J Radiol ; 146: 110101, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34952368

ABSTRACT

PURPOSE: To evaluate the incidence and risk factors of late adverse reactions (ARs) to non-ionic low-osmolar contrast media (LOCM). METHODS: The occurrence of late AR was monitored on day 1 and from day 7 to day 28 in all patients who received enhanced computed tomography using LOCM during a 5-week study period in a single tertiary hospital. Patients who experienced late AR were followed up for three years. RESULTS: Among the total 10,540 LOCM exposures, 315 ARs (3.0%) were reported; acute ARs occurred in 108 LOCM exposures (1.0%) and late ARs occurred in 207 LOCM exposures (2.0%) (90.9% within one week, 9.1% developed afterwards by day 20). Previous history of drug allergy (odds ratio [OR] = 4.59; 95% confidence interval [CI] 2.17-9.71) and allergic diseases (OR = 2.54; 95% CI 1.32-4.91) were risk factors of late ARs to LOCM. Although the recurrence rate was lowered with premedication from 8.5% to 1.7% (8/94 vs. 3/178; p = 0.016), LOCM change did not make difference compared to reuse of the culprit LOCM (2/38 vs. 9/234; p = 0.655). In patients with a history of late AR to LOCM, the risk of recurrent reactions decreased with longer time intervals between exposures (OR = 0.86; 95% CI: 0.77-0.97; p = 0.025) and with the use of antihistamine premedication (OR = 0.27; 95% CI: 0.06-0.99; p = 0.049). CONCLUSIONS: Late ARs to LOCM occurred mostly within one week. The use of premedication may be helpful in reducing the recurrence of late ARs.


Subject(s)
Contrast Media , Contrast Media/adverse effects , Humans , Incidence , Osmolar Concentration , Prospective Studies , Risk Factors
15.
Int J Numer Method Biomed Eng ; 38(2): e3555, 2022 02.
Article in English | MEDLINE | ID: mdl-34859615

ABSTRACT

The intraluminal thrombus (ILT) has been shown to negatively impact the progression of the abdominal aortic aneurysms (AAAs). The formation of this thrombus layer has been connected to the local flow environment within AAAs, but the specific mechanisms leading to thrombus formation are still not fully understood. Our study investigated the association between vortical structures, near-wall hemodynamic metrics (e.g., time averaged wall shear stress (TAWSS) and oscillatory shear index (OSI)), and ILT accumulation in a longitudinal cohort of 14 AAAs (53 scans total). Vortices and hemodynamic parameters were estimated using hemodynamic simulations performed to each scan of each patient and compared to local 3D changes of ILT thickness between two consecutive scans (ΔILT). Results showed that vortices formed and remained strong and close to the lumen surface in AAAs without an ILT, while in AAAs with ILTs these detached from the lumen surface and dissipated nearby wall region where an increase in ILT thickness was observed. Although low TAWSS was observed in regions with and without ILT accumulation, an inverse correlation between ∆ILT and TAWSS was observed within the regions that experienced a thrombus growth. Our results support the idea that vortical structures might be playing a role modulating ILT accumulation into specific wall regions. Also, it submits the idea that the low TAWSS will be modulating the growth of thrombus within these preferred ILT accumulated regions.


Subject(s)
Aortic Aneurysm, Abdominal , Thrombosis , Diagnostic Imaging , Hemodynamics , Humans , Stress, Mechanical
16.
J Am Coll Cardiol ; 78(6): 545-558, 2021 08 10.
Article in English | MEDLINE | ID: mdl-34353531

ABSTRACT

BACKGROUND: Cardiovascular magnetic resonance (CMR) is increasingly used for risk stratification in aortic stenosis (AS). However, the relative prognostic power of CMR markers and their respective thresholds remains undefined. OBJECTIVES: Using machine learning, the study aimed to identify prognostically important CMR markers in AS and their thresholds of mortality. METHODS: Patients with severe AS undergoing AVR (n = 440, derivation; n = 359, validation cohort) were prospectively enrolled across 13 international sites (median 3.8 years' follow-up). CMR was performed shortly before surgical or transcatheter AVR. A random survival forest model was built using 29 variables (13 CMR) with post-AVR death as the outcome. RESULTS: There were 52 deaths in the derivation cohort and 51 deaths in the validation cohort. The 4 most predictive CMR markers were extracellular volume fraction, late gadolinium enhancement, indexed left ventricular end-diastolic volume (LVEDVi), and right ventricular ejection fraction. Across the whole cohort and in asymptomatic patients, risk-adjusted predicted mortality increased strongly once extracellular volume fraction exceeded 27%, while late gadolinium enhancement >2% showed persistent high risk. Increased mortality was also observed with both large (LVEDVi >80 mL/m2) and small (LVEDVi ≤55 mL/m2) ventricles, and with high (>80%) and low (≤50%) right ventricular ejection fraction. The predictability was improved when these 4 markers were added to clinical factors (3-year C-index: 0.778 vs 0.739). The prognostic thresholds and risk stratification by CMR variables were reproduced in the validation cohort. CONCLUSIONS: Machine learning identified myocardial fibrosis and biventricular remodeling markers as the top predictors of survival in AS and highlighted their nonlinear association with mortality. These markers may have potential in optimizing the decision of AVR.


Subject(s)
Aortic Valve Stenosis , Fibrosis/diagnostic imaging , Heart Valve Prosthesis Implantation , Magnetic Resonance Imaging, Cine , Myocardium/pathology , Ventricular Remodeling , Aged , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/mortality , Cardiac Imaging Techniques/methods , Female , Heart Function Tests/methods , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Humans , Machine Learning , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Imaging, Cine/statistics & numerical data , Male , Prognosis , Reproducibility of Results , Risk Assessment/methods , Severity of Illness Index , Survival Analysis
17.
Korean J Radiol ; 22(10): 1708-1718, 2021 10.
Article in English | MEDLINE | ID: mdl-34402245

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the magnetic resonance (MR) characteristics and applicability of new, uniform, extremely small iron-based nanoparticles (ESIONs) with 3-4-nm iron cores using contrast-enhanced magnetic resonance angiography (MRA). MATERIALS AND METHODS: Seven types of ESIONs were used in phantom and animal experiments with 1.5T, 3T, and 4.7T scanners. The MR characteristics of the ESIONs were evaluated via phantom experiments. With the ESIONs selected by the phantom experiments, animal experiments were performed on eight rabbits. In the animal experiments, the in vivo kinetics and enhancement effect of the ESIONs were evaluated using half-diluted and non-diluted ESIONs. The between-group differences were assessed using a linear mixed model. A commercially available gadolinium-based contrast agent (GBCA) was used as a control. RESULTS: All ESIONs showed a good T1 shortening effect and were applicable for MRA at 1.5T and 3T. The relaxivity ratio of the ESIONs increased with increasing magnetic field strength. In the animal experiments, the ESIONs showed peak signal intensity on the first-pass images and persistent vascular enhancement until 90 minutes. On the 1-week follow-up images, the ESIONs were nearly washed out from the vascular structures and organs. The peak signal intensity on the first-pass images showed no significant difference between the non-diluted ESIONs with 3-mm iron cores and GBCA (p = 1.000). On the 10-minutes post-contrast images, the non-diluted ESIONs showed a significantly higher signal intensity than did the GBCA (p < 0.001). CONCLUSION: In the phantom experiments, the ESIONs with 3-4-nm iron oxide cores showed a good T1 shortening effect at 1.5T and 3T. In the animal experiments, the ESIONs with 3-nm iron cores showed comparable enhancement on the first-pass images and superior enhancement effect on the delayed images compared to the commercially available GBCA at 3T.


Subject(s)
Contrast Media , Nanoparticles , Animals , Iron , Magnetic Resonance Angiography , Magnetic Resonance Imaging , Rabbits
18.
Korean J Radiol ; 22(11): 1918-1928, 2021 11.
Article in English | MEDLINE | ID: mdl-34431249

ABSTRACT

OBJECTIVE: With the recent development of various MRI-conditional cardiac implantable electronic devices (CIEDs), the accurate identification and characterization of CIEDs have become critical when performing MRI in patients with CIEDs. We aimed to develop and evaluate a deep learning-based algorithm (DLA) that performs the detection and characterization of parameters, including MRI safety, of CIEDs on chest radiograph (CR) in a single step and compare its performance with other related algorithms that were recently developed. MATERIALS AND METHODS: We developed a DLA (X-ray CIED identification [XCID]) using 9912 CRs of 958 patients with 968 CIEDs comprising 26 model groups from 4 manufacturers obtained between 2014 and 2019 from one hospital. The performance of XCID was tested with an external dataset consisting of 2122 CRs obtained from a different hospital and compared with the performance of two other related algorithms recently reported, including PacemakerID (PID) and Pacemaker identification with neural networks (PPMnn). RESULTS: The overall accuracies of XCID for the manufacturer classification, model group identification, and MRI safety characterization using the internal test dataset were 99.7% (992/995), 97.2% (967/995), and 98.9% (984/995), respectively. These were 95.8% (2033/2122), 85.4% (1813/2122), and 92.2% (1956/2122), respectively, with the external test dataset. In the comparative study, the accuracy for the manufacturer classification was 95.0% (152/160) for XCID and 91.3% for PPMnn (146/160), which was significantly higher than that for PID (80.0%,128/160; p < 0.001 for both). XCID demonstrated a higher accuracy (88.1%; 141/160) than PPMnn (80.0%; 128/160) in identifying model groups (p < 0.001). CONCLUSION: The remarkable and consistent performance of XCID suggests its applicability for detection, manufacturer and model identification, as well as MRI safety characterization of CIED on CRs. Further studies are warranted to guarantee the safe use of XCID in clinical practice.


Subject(s)
Deep Learning , Defibrillators, Implantable , Pacemaker, Artificial , Algorithms , Electronics , Humans , Magnetic Resonance Imaging
19.
Comput Methods Programs Biomed ; 208: 106256, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34242864

ABSTRACT

OBJECTIVE: The maximum diameter measurement of an abdominal aortic aneurysm (AAA), which depends on orthogonal and axial cross-sections or maximally inscribed spheres within the AAA, plays a significant role in the clinical decision making process. This study aims to build a total of 21 morphological parameters from longitudinal CT scans and analyze their correlations. Furthermore, this work explores the existence of a "master curve" of AAA growth, and tests which parameters serve to enhance its predictability for clinical use. METHODS: 106 CT scan images from 25 Korean AAA patients were retrospectively obtained. We subsequently computed morphological parameters, growth rates, and pair-wise correlations, and attempted to enhance the predictability of the growth for high-risk aneurysms using non-linear curve fitting and least-square minimization. RESULTS: An exponential AAA growth model was fitted to the maximum spherical diameter, as the best representative of the growth among all parameters (r-square: 0.94) and correctly predicted to 15 of 16 validation scans based on a 95% confidence interval. AAA volume expansion rates were highly correlated (r=0.75) with thrombus accumulation rates. CONCLUSIONS: The exponential growth model using spherical diameter provides useful information about progression of aneurysm size and enables AAA growth rate extrapolation during a given surveillance period.


Subject(s)
Aortic Aneurysm, Abdominal , Thrombosis , Aortic Aneurysm, Abdominal/diagnostic imaging , Disease Progression , Humans , Retrospective Studies , Tomography, X-Ray Computed
20.
Korean J Radiol ; 22(5): 688-696, 2021 05.
Article in English | MEDLINE | ID: mdl-33543843

ABSTRACT

OBJECTIVE: To compare the lumen parameters measured by the location-adaptive threshold method (LATM), in which the inter- and intra-scan attenuation variabilities of coronary computed tomographic angiography (CCTA) were corrected, and the scan-adaptive threshold method (SATM), in which only the inter-scan variability was corrected, with the reference standard measurement by intravascular ultrasonography (IVUS). MATERIALS AND METHODS: The Hounsfield unit (HU) values of whole voxels and the centerline in each of the cross-sections of the 22 target coronary artery segments were obtained from 15 patients between March 2009 and June 2010, in addition to the corresponding voxel size. Lumen volume was calculated mathematically as the voxel volume multiplied by the number of voxels with HU within a given range, defined as the lumen for each method, and compared with the IVUS-derived reference standard. Subgroup analysis of the lumen area was performed to investigate the effect of lumen size on the studied methods. Bland-Altman plots were used to evaluate the agreement between the measurements. RESULTS: Lumen volumes measured by SATM was significantly smaller than that measured by IVUS (mean difference, 14.6 mm³; 95% confidence interval [CI], 4.9-24.3 mm³); the lumen volumes measured by LATM and IVUS were not significantly different (mean difference, -0.7 mm³; 95% CI, -9.1-7.7 mm³). The lumen area measured by SATM was significantly smaller than that measured by LATM in the smaller lumen area group (mean of difference, 1.07 mm²; 95% CI, 0.89-1.25 mm²) but not in the larger lumen area group (mean of difference, -0.07 mm²; 95% CI, -0.22-0.08 mm²). In the smaller lumen group, the mean difference was lower in the Bland-Altman plot of IVUS and LATM (0.46 mm²; 95% CI, 0.27-0.65 mm²) than in that of IVUS and SATM (1.53 mm²; 95% CI, 1.27-1.79 mm²). CONCLUSION: SATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM.


Subject(s)
Computed Tomography Angiography , Coronary Vessels/diagnostic imaging , Aged , Algorithms , Coronary Artery Disease/diagnosis , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Proof of Concept Study , Retrospective Studies , Ultrasonography, Interventional