Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Colloid Interface Sci ; 652(Pt A): 692-704, 2023 Dec 15.
Article in English | MEDLINE | ID: mdl-37453873

ABSTRACT

With the current upsurge in hydrogen economies all over the world, an increased demand for improved chemiresistive H2 sensors that are highly responsive and fast acting when exposed to gases is expected. Owing to safety concerns about explosive and highly flammable H2 gas, it is important to develop resistive sensors that can detect the leakage of H2 gas swiftly and selectively. Currently, interest in metal-organic frameworks (MOFs) for gas-sensor applications is increasing due to their open-metal sites, large surface area, and unique surface morphologies. In this research, a highly selective and sensitive H2-sensor was established based on graphitic carbon (GC) anchored spherical Pd@PdO core-shells over γ-Fe2O3 microcube (Pd@PdO/γ-Fe2O3@GC which is termed as S3) heterostructure materials. The combined solvothermal followed by controlled calcination-assisted S3 exhibited a specific morphology with the highest surface area of 79.12 m2 g-1, resulting in fast response and recovery times (21 and 29 s, respectively), and excellent sensing performance (ΔR/R0∼ 96.2 ± 1.5), outstanding long-term stability, and a 100 ppb detection limit when detecting H2-gas at room temperature (mainly in very humid surroundings). This result proves that adsorption sites provided by S3 can promote surface reactions (adsorption and desorption) for ultrasensitive and selective H2gas sensors.

2.
J Med Virol ; 95(8): e28978, 2023 08.
Article in English | MEDLINE | ID: mdl-37515534

ABSTRACT

Dengue virus, which belongs to the Flaviviridae family, can induce a range of symptoms from mild to severe, including dengue fever, dengue hemorrhagic fever, and dengue shock syndrome. While infectious cloning technology is a useful tool for understanding viral pathogenesis and symptoms, it exhibits limitations when constructing the entire Flavivirus genome. The instability and toxicity of the genome to bacteria make its full-length construction in bacterial vectors a time-consuming and laborious process. To address these challenges, we employed the modified infectious subgenomic amplicon (ISA) method in this study, which can potentially be a superior tool for reverse genetic studies on the dengue virus. Using ISA, we generated recombinant dengue viruses de novo and validated their robust replication in both human and insect cell lines, which was comparable to that of the original strains. Moreover, the efficiency of ISA in genetically modifying the dengue virus was elucidated by successfully inserting the gene for green fluorescence protein into the genome of dengue virus serotype 4. Overall, this study highlighted the effectiveness of ISA for genetically engineering the dengue virus and provided a technical basis for a convenient reverse genetics system that could expedite investigations into the dengue virus.


Subject(s)
Dengue Virus , Dengue , Flaviviridae , Flavivirus , Humans , Dengue Virus/genetics , Reverse Genetics/methods , Flavivirus/genetics , Flaviviridae/genetics , Virus Replication/genetics
3.
Sensors (Basel) ; 23(3)2023 Feb 02.
Article in English | MEDLINE | ID: mdl-36772688

ABSTRACT

In this study, a 0-3 piezoelectric composite based on lead zirconate-titanate (PZT)/polyvinyl-butyral (PVB) was fabricated and characterized for its potential application in tactile sensing. The 0-3 composite was developed to incorporate the advantages of both ceramic and polymer. The paste of 0-3 PZT-PVB composite was printed using a conventional screen-printing technique on alumina and mylar substrates. The thickness of the prepared composite was approximately 80 µm. After printing the top electrode of the silver paste, 10 kV/mm of DC field was applied at 25 °C, 120 °C, and 150 °C for 10 min to align the electric dipoles in the composite. The piezoelectric charge coefficient of d33 and the piezoelectric voltage coefficient of g33 were improved by increasing the temperature of the poling process. The maximum values of d33 and g33 were 14.3 pC/N and 44.2 mV·m/N, respectively, at 150 °C. The sensor's sensitivity to the impact force was measured by a ball drop test. The sensors showed a linear behavior in the output voltage with increasing impact force. The sensitivity of the sensor on the alumina and mylar substrates was 1.368 V/N and 0.815 V/N, respectively. The rising time of the sensor to the finger touch was 43 ms on the alumina substrate and 35 ms on the mylar substrate. Consequently, the high sensitivity and fast response time of the sensor make the 0-3 PZT-PVB composite a good candidate for tactile sensors.

SELECTION OF CITATIONS
SEARCH DETAIL
...