Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38561141

ABSTRACT

BACKGROUND: Allergic rhinitis (AR) and asthma may affect health-related quality of life. However, national estimates on the quality of life of patients with AR or asthma are lacking. OBJECTIVE: To provide estimates for utility scores and EuroQoL five-dimension (EQ-5D) visual analog scale (VAS) for patients with AR or asthma. METHODS: We conducted a cross-sectional study using direct patient data from the MASK-air app on European MASK-air users with self-reported AR or asthma. We used a multi-attribute instrument (EQ-5D) to measure quality of life (as utility scores and EQ-5D VAS values). Mean scores were calculated per country and disease control level using multilevel regression models with poststratification, accounting for age and sex biases. RESULTS: We assessed data from 7905 MASK-air users reporting a total of up to 82,737 days. For AR, utilities ranged from 0.86 to 0.99 for good control versus 0.72 to 0.85 for poor control; EQ-5D VAS levels ranged from 78.9 to 87.9 for good control versus 55.3 to 64.2 for poor control. For asthma, utilities ranged from 0.84 to 0.97 for good control versus 0.73 to 0.87 for poor control; EQ-5D VAS levels ranged from 68.4 to 81.5 for good control versus 51.4 to 64.2 for poor control. Poor disease control was associated with a mean loss of 0.14 utilities for both AR and asthma. For the same control levels, AR and asthma were associated with similar utilities and EQ-5D VAS levels. However, lower values were observed for asthma plus AR compared with AR alone. CONCLUSIONS: Poor AR or asthma control are associated with reduced quality of life. The estimates obtained from mobile health data may provide valuable insights for health technology assessment studies.

2.
World J Urol ; 39(4): 1115-1119, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32638084

ABSTRACT

OBJECTIVE: To compare cancer control in anterior compared to posterior prostate cancer lesions treated with a focal HIFU therapy approach. MATERIALS AND METHODS: In a prospectively maintained national database, 598 patients underwent focal HIFU (Sonablate®500) (March/2007-November/2016). Follow-up occurred with 3-monthly clinic visits and PSA testing in the first year with PSA, every 6-12 months with mpMRI with biopsy for MRI-suspicion of recurrence. Treatment failure was any secondary treatment (ADT/chemotherapy, cryotherapy, EBRT, RRP, or re-HIFU), tumour recurrence with Gleason ≥ 3 + 4 on prostate biopsy without further treatment or metastases/prostate cancer-related mortality. Cases with anterior cancer were compared to those with posterior disease. RESULTS: 267 patients were analysed following eligibility criteria. 45 had an anterior focal-HIFU and 222 had a posterior focal-HIFU. Median age was 64 years and 66 years, respectively, with similar PSA level of 7.5 ng/ml and 6.92 ng/ml. 84% and 82%, respectively, had Gleason 3 + 4, 16% in both groups had Gleason 4 + 3, 0% and 2% had Gleason 4 + 4. Prostate volume was similar (33 ml vs. 36 ml, p = 0.315); median number of positive cores in biopsies was different in anterior and posterior tumours (7 vs. 5, p = 0.009), while medium cancer core length, and maximal cancer percentage of core were comparable. 17/45 (37.8%) anterior focal-HIFU patients compared to 45/222 (20.3%) posterior focal-HIFU patients required further treatment (p = 0.019). CONCLUSION: Treating anterior prostate cancer lesions with focal HIFU may be less effective compared to posterior tumours.


Subject(s)
Prostatic Neoplasms/pathology , Prostatic Neoplasms/surgery , Ultrasound, High-Intensity Focused, Transrectal , Aged , Humans , Male , Middle Aged , Retrospective Studies
3.
J Endourol ; 34(6): 641-646, 2020 06.
Article in English | MEDLINE | ID: mdl-32253928

ABSTRACT

Objective: Analysis of treatment success regarding oncological recurrence rate between standard and dose escalation focal high-intensity focused ultrasound (HIFU) of prostate cancer. Materials and Methods: In this analysis of our prospectively maintained HIFU (Sonablate® 500) database, 598 patients were identified who underwent a focal HIFU (Sonablate 500) between March 2007 and November 2016. Follow-up occurred with 3-monthly clinic visits and prostate specific antigen (PSA) testing in the first year. Thereafter, PSA was measured 6-monthly or annually at least. Routine and for-cause multiparametric MRI (mpMRI) was conducted with biopsy for MRI suspicion of recurrence. Treatments were delivered in a quadrant or hemiablation fashion depending on the gland volume as well as tumor volume and location. Before mid-2015, standard focal HIFU was used (two HIFU blocks); after this date, some urologists conducted dose escalation focal HIFU (three overlapping HIFU blocks). Propensity matching was used to ensure two matched groups, leading to 162 cases for this analysis. Treatment failure was defined by any secondary treatment (systemic therapy, cryotherapy, radiotherapy, prostatectomy, or further HIFU), metastasis from prostate cancer without further treatment, tumor recurrence with Gleason score ≥7 (≥3 + 4) on prostate biopsy without further treatment, or prostate cancer-related mortality. Complications and side-effects were also compared. Results: Median age was 64.5 years (interquartile range [IQR] 60-73.5) in the standard focal-HIFU group and 64.5 years (IQR 60-69) in the dose-escalation group. Median prostate volume was 37 mL (IQR 17-103) in the standard group and 47.5 mL (IQR 19-121) in the dose-escalation group. As tumor volume on mpMRI and Gleason score were major matching criteria, these were identical with 0.43 mL (IQR 0.05-2.5) and Gleason 3 + 3 = 6 in 1 out of 32 (3%), 3 + 4 = 7 in 27 out of 32 (84%), and 4 + 3 = 7 in 4 out of 32 (13%). Recurrence in treated areas was found in 10 out of 32 (31%) when standard treatment zones were applied, and in 6 out of 32 (19%) of dose-escalation focal HIFU (p = 0.007). Conclusion: This exploratory study shows that dose escalation focal HIFU may achieve higher rates of disease control compared with standard focal HIFU. Further prospective comparative studies are needed.


Subject(s)
Prostatic Neoplasms , Ultrasound, High-Intensity Focused, Transrectal , Aged , Humans , Male , Middle Aged , Neoplasm Recurrence, Local , Prostate-Specific Antigen , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Reference Standards , Treatment Outcome
4.
J Urol ; 203(4): 734-742, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31928408

ABSTRACT

PURPOSE: We determined whether prostate specific antigen criteria after focal high intensity focused ultrasound to treat prostate cancer could diagnose treatment failure. MATERIALS AND METHODS: A total of 598 patients in a prospectively maintained national database underwent focal high intensity focused ultrasound with a Sonablate® 500 device from March 2007 to November 2016. Followup consisted of 3-month clinic visits and prostate specific antigen testing in year 1 with prostate specific antigen measurement every 6 to 12 months and multiparametric magnetic resonance imaging with biopsy for magnetic resonance imaging suspicious for recurrence. Treatment failure was considered any secondary treatment, tumor recurrence with Gleason 3 + 4 or greater disease on prostate biopsy without further treatment or metastasis and/or prostate cancer related mortality. To diagnose failure we evaluated a series of nadir + x thresholds with x values of 0.1 to 2.0 ng/ml. RESULTS: Median patient age was 65 years (IQR 60-71) and the median Gleason score was 7 (range 6-9). Gleason 3 + 4 or greater disease was present in 80% of cases. Tumors were radiologically staged as T1c-T2c in 522 of the 596 patients (88%) and as T3a/b in 74 (12.4%). Baseline median prostate specific antigen was 7.80 ng/ml (IQR 5.96-10.45) in failed cases and 6.77 ng/ml (IQR 2.65-9.71) in cases without failure. Optimal performance according to the Youden index to indicate the most appropriate nadir + x at all analyzed time points at 3-month intervals showed that nadir + 1.0 ng/ml would have 27.3% to 100% sensitivity and 39.4% to 85.6% specificity depending on the time of evaluation in the first 3 years. Nadir + 1.5 ng/ml showed 18.2% to 100% sensitivity and 60.6% to 91.8% specificity with nadir + 2.0 ng/ml leading to similar sensitivity and specificity ranges. Nadir + 1.0 ng/ml at 12 months and nadir + 1.5 ng/ml at 24 and 36 months had 100% sensitivity and 96.1% to 100% negative predictive value. CONCLUSIONS: Following focal high intensity focused ultrasound a prostate specific antigen nadir of 1.0 ng/ml at 12 months and 1.5 ng/ml at 24 to 36 months might be used to triage men requiring magnetic resonance imaging and biopsy. These data need prospective validation.


Subject(s)
Androgen Antagonists/therapeutic use , Kallikreins/blood , Neoplasm Recurrence, Local/diagnosis , Prostate-Specific Antigen/blood , Prostatic Neoplasms/therapy , Ultrasound, High-Intensity Focused, Transrectal , Aged , Feasibility Studies , Follow-Up Studies , Humans , Male , Middle Aged , Multiparametric Magnetic Resonance Imaging , Neoadjuvant Therapy/methods , Neoplasm Recurrence, Local/blood , Neoplasm Recurrence, Local/prevention & control , Prospective Studies , Prostate/diagnostic imaging , Prostate/pathology , Prostate/radiation effects , Prostatic Neoplasms/blood , Prostatic Neoplasms/diagnosis , Sensitivity and Specificity , Treatment Failure
SELECTION OF CITATIONS
SEARCH DETAIL
...