Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Malar J ; 19(1): 305, 2020 Aug 27.
Article in English | MEDLINE | ID: mdl-32854715

ABSTRACT

BACKGROUND: 125 million women are pregnant each year in malaria endemic areas and are, therefore, at risk of Malaria in Pregnancy (MiP). MiP is the direct consequence of Plasmodium infection during pregnancy. The sequestration of Plasmodium falciparum parasites in the placenta adversely affects fetal development and impacts newborn birth weight. Importantly, women presenting with MiP commonly develop anaemia. In Ethiopia, the Ministry of Health recommends screening symptomatic women only at antenatal care visits with no formal intermittent preventive therapy. Since MiP can display low-level parasitaemia, current tests which include microscopy and RDT are challenged to detect these cases. Loop mediated isothermal Amplification (LAMP) technology is a highly sensitive technique for DNA detection and is field compatible. This study aims to evaluate the impact of active malaria case detection during pregnancy using LAMP technology in terms of birth outcomes. METHODS: A longitudinal study was conducted in two health centres of the Kafa zone, South West Ethiopia. Both symptomatic and asymptomatic pregnant women were enrolled in the first or second trimester and allocated to either Standard of Care (SOC-microscopy and RDT) or LAMP (LAMP, microscopy and RDT). Women completed at least three visits prior to delivery, and the patient was referred for treatment if Plasmodium infection was detected by any of the testing methods. The primary outcome was to measure absolute birth weight, proportion of low birth weight, and maternal/neonatal haemoglobin in each arm. Secondary outcomes were to assess the performance of microscopy and RDT versus LAMP conducted in the field. RESULTS: One hundred and ninety-nine women were included and assigned to either LAMP or SOC. Six were lost to follow up. In this cohort, 66.8% of women did not display any clinical symptoms and 70.9% were multi-parous. A reduced proportion of low birth weight newborns was observed in the LAMP group (0%) compared to standard of care (14%) (p <0.001). Improved neonatal haemoglobin was observed in the LAMP (13.1 g/dL) versus the SOC (12.8 g/dL) (p = 0.024) arm. RDT and microscopy had an analytical sensitivity of 66.7% and 55.6% compared to LAMP as a reference standard. CONCLUSIONS: These results support the use of highly sensitive tools for rapid on-site active case detection of MiP which may improve birth outcomes in the absence of IPT. However, further large-scale studies are required to confirm this finding.


Subject(s)
Malaria, Falciparum/epidemiology , Malaria, Vivax/epidemiology , Molecular Diagnostic Techniques/statistics & numerical data , Nucleic Acid Amplification Techniques/statistics & numerical data , Plasmodium falciparum/isolation & purification , Plasmodium vivax/isolation & purification , Pregnancy Complications, Parasitic/epidemiology , Adult , Diagnostic Tests, Routine , Ethiopia/epidemiology , Female , Humans , Longitudinal Studies , Malaria, Falciparum/diagnosis , Malaria, Falciparum/parasitology , Malaria, Vivax/diagnosis , Malaria, Vivax/parasitology , Pilot Projects , Pregnancy , Pregnancy Complications, Parasitic/diagnosis , Pregnancy Complications, Parasitic/parasitology , Prevalence , Young Adult
2.
Clin Infect Dis ; 69(6): 1003-1010, 2019 08 30.
Article in English | MEDLINE | ID: mdl-30475992

ABSTRACT

BACKGROUND: As the global public-health objectives for malaria evolve from malaria control towards malaria elimination, there is increasing interest in the significance of asymptomatic infections and the optimal diagnostic test to identify them. METHOD: We conducted a cross-sectional study of asymptomatic individuals (N = 562) to determine the epidemiological characteristics associated with asymptomatic malaria. Participants were tested by rapid diagnostic tests (CareStart, Standard Diagnostics [SD] Bioline, and Alere ultrasensitive RDT [uRDT]), loop-mediated isothermal amplification (LAMP), and quantitative reverse transcription polymerase chain reaction (qRT-PCR) to determine malaria positivity. Hemoglobin values were recorded, and anemia was defined as a binary variable, according to World Health Organization guidelines. RESULTS: Compared to reference qRT-PCR, LAMP had the highest sensitivity (92.6%, 95% confidence interval [CI] 86.4-96.5), followed by uRDT Alere Malaria (33.9%, 95% CI 25.5-43.1), CareStart Malaria (14.1%, 95% CI 8.4-21.5), microscopy (5.0%, 95% CI 1.8-10.5), and SD Bioline (5.0%, 95% CI 1.8-10.5). For Plasmodium falciparum specimens only, the sensitivity for uRDT Alere Malaria was 50.0% (95% CI 38.8-61.3) and SD Bioline was 7.3% (95% CI 2.7-15.3). Based on multivariate regression analysis with qRT-PCR as the gold standard, for every 3.2% increase in the prevalence of asymptomatic malaria, hemoglobin decreased by 1 gram per deciliter (prevalence ratio 0.968, 95% CI 0.940-0.997; P = .032). Deletions (4.8%) in hrp2 were noted. CONCLUSIONS: While uRDT Alere Malaria has superior sensitivity to rapid diagnostic tests and microscopy in detecting asymptomatic malaria, LAMP is superior still. Ultrasensitive diagnostics provide the accurate prevalence estimates of asymptomatic malaria required for elimination.


Subject(s)
Asymptomatic Infections/epidemiology , Diagnostic Tests, Routine/standards , Malaria/diagnosis , Malaria/epidemiology , Adolescent , Antigens, Protozoan/genetics , Child , Cross-Sectional Studies , Diagnostic Tests, Routine/methods , Female , Humans , Malaria/parasitology , Male , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , Plasmodium/classification , Plasmodium/genetics , Population Surveillance , Prevalence , Protozoan Proteins/genetics , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...