1.
J Nucl Med ; 65(3): 446-452, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38238040

ABSTRACT

This study evaluated the potential to reduce the scan duration in dopamine transporter (DAT) SPECT when using a second-generation multiple-pinhole (MPH) collimator designed for brain SPECT with improved count sensitivity and improved spatial resolution compared with parallel-hole and fanbeam collimators. Methods: The retrospective study included 640 consecutive clinical DAT SPECT studies that had been acquired in list mode with a triple-head SPECT system with MPH collimators and a 30-min net scan duration after injection of 181 ± 10 MBq of [123I]FP-CIT. Raw data corresponding to scan durations of 20, 15, 12, 8, 6, and 4 min were obtained by restricting the events to a proportionally reduced time interval of the list-mode data for each projection angle. SPECT images were reconstructed iteratively with the same parameter settings irrespective of scan duration. The resulting 5,120 SPECT images were assessed for a neurodegeneration-typical reduction in striatal signal by visual assessment, conventional specific binding ratio analysis, and a deep convolutional neural network trained on 30-min scans. Results: Regarding visual interpretation, image quality was considered diagnostic for all 640 patients down to a 12-min scan duration. The proportion of discrepant visual interpretations between 30 and 12 min (1.2%) was not larger than the proportion of discrepant visual interpretations between 2 reading sessions of the same reader at a 30-min scan duration (1.5%). Agreement with the putamen specific binding ratio from the 30-min images was better than expected for 5% test-retest variability down to a 10-min scan duration. A relevant change in convolutional neural network-based automatic classification was observed at a 6-min scan duration or less. Conclusion: The triple-head SPECT system with MPH collimators allows reliable DAT SPECT after administration of about 180 MBq of [123I]FP-CIT with a 12-min scan duration.


Subject(s)
Dopamine Plasma Membrane Transport Proteins , Tomography, Emission-Computed, Single-Photon , Humans , Dopamine Plasma Membrane Transport Proteins/metabolism , Retrospective Studies , Tomography, Emission-Computed, Single-Photon/methods , Tropanes
2.
EJNMMI Phys ; 10(1): 25, 2023 Mar 29.
Article in English | MEDLINE | ID: mdl-36991245

ABSTRACT

BACKGROUND: The specific binding ratio (SBR) of 123I-FP-CIT in the putamen is widely used to support the interpretation of dopamine transporter (DAT) SPECT. Automatic methods for computation of the putamen SBR often include stereotactical normalization of the individual DAT-SPECT image to an anatomical standard space. This study compared using a single 123I-FP-CIT template image as target for stereotactical normalization versus multiple templates representative of normal and different levels of Parkinson-typical reduction of striatal 123I-FP-CIT uptake. METHODS: 1702 clinical 123I-FP-CIT SPECT images were stereotactically normalized (affine) to the anatomical space of the Montreal Neurological Institute (MNI) with SPM12 either using a single custom-made 123I-FP-CIT template representative of normal striatal uptake or using eight different templates representative of normal and different levels of Parkinson-typical reduction of striatal FP-CIT uptake with and without attenuation and scatter correction. In the latter case, SPM finds the linear combination of the multiple templates that best matches the patient's image. The putamen SBR was obtained using hottest voxels analysis in large unilateral regions-of-interest predefined in MNI space. The histogram of the putamen SBR in the whole sample was fitted by the sum of two Gaussians. The power to differentiate between reduced and normal SBR was estimated by the effect size of the distance between the two Gaussians computed as the differences between their mean values scaled to their pooled standard deviation. RESULTS: The effect size of the distance between the two Gaussians was 3.83 with the single template versus 3.96 with multiple templates for stereotactical normalization. CONCLUSIONS: Multiple templates representative of normal and different levels of Parkinson-typical reduction for stereotactical normalization of DAT-SPECT might provide improved separation between normal and reduced putamen SBR that could result in slightly improved power for the detection of nigrostriatal degeneration.

3.
J Nucl Med ; 64(1): 59-62, 2023 01.
Article in English | MEDLINE | ID: mdl-35835582

ABSTRACT

This case series evaluated the feasibility of prostate-specific membrane antigen (PSMA)-radioguided surgery (RGS) with 99mTc-MIP-1404 in recurrent prostate cancer. Methods: Nine patients with PSMA-positive lesions on PET/CT received 99mTc-MIP-1404 (median, 747 MBq; interquartile range [IQR], 710-764 MBq) 17.2 h (IQR, 16.9-17.5 h) before SPECT/CT and 22.3 h (IQR, 20.8-24.0 h) before RGS. Results: Seventeen PSMA-positive lesions were detected on PET/CT (median short-axis diameter, 4 mm; IQR, 3-6 mm; median SUVmax, 8.9; IQR, 5.2-12.6). Nine of 17 (52.9%) were visible on SPECT/CT (median SUVmax, 13.8; IQR, 8.0-17.9). Except for 2 foci, all PET/CT-positive findings demonstrated intraoperative count rates above the background level (median count, 31; IQR, 17-89) and were lymph node metastases. Moreover, PSMA-RGS identified 2 additional metastases compared with PET/CT. Prostate-specific antigen values decreased after RGS in 6 of 9 patients (67%). Conclusion: PSMA-RGS with 99mTc-MIP-1404 identified lymph node metastases in all patients, including 2 additional lesions compared with PET/CT.


Subject(s)
Prostatic Neoplasms , Surgery, Computer-Assisted , Male , Humans , Positron Emission Tomography Computed Tomography/methods , Lymphatic Metastasis , Feasibility Studies , Neoplasm Recurrence, Local/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Prostatic Neoplasms/pathology , Single Photon Emission Computed Tomography Computed Tomography , Surgery, Computer-Assisted/methods , Gallium Radioisotopes
4.
EJNMMI Res ; 12(1): 1, 2022 Jan 10.
Article in English | MEDLINE | ID: mdl-35006412

ABSTRACT

PURPOSE: [18F]PR04.MZ is a new PET imaging agent for dopamine transporters, providing excellent image quality and allowing for the evaluation of patients with movement disorders such as Parkinson's disease. The objective of this study was to evaluate the biodistribution and radiation dosimetry of [18F]PR04.MZ by serial PET imaging. METHODS: Six healthy subjects (n = 3 males, n = 3 females) were enrolled in this study. A series of 14 whole-body PET/CT scans were acquired until 5.5 h post-injection of 200 ± 11 MBq of [18F]PR04.MZ. After rigid co-registration, volumes of interest were outlined either on CT or PET images. Time-integrated activity coefficients were calculated for selected source organs. Organ absorbed doses, and the effective dose were calculated using IDAC-Dose 2.1. RESULTS: Physiological uptake of [18F]PR04.MZ was mainly observed in the striatum, brain, liver, gall bladder, intestine, red marrow and cortical bone. [18F]PR04.MZ was primarily excreted via hepatobiliary clearance and, to a lower extent, via renal clearance. The normalized absorbed doses were highest in gall bladder wall (32.2 ± 6.4 µGy/MBq), urinary bladder wall (27.2 ± 4.5 µGy/MBq), red marrow (26.5 ± 1.4 µGy/MBq), cortical bone surface (26.3 ± 2.5 µGy/MBq), liver (22.5 ± 1.8 µGy/MBq) and kidneys (21.8 ± 1.1 µGy/MBq). The effective dose according to ICRP 60 and 103 was 16.3 ± 1.1 and 16.6 ± 1.5 µSv/MBq, respectively. CONCLUSION: [18F]PR04.MZ has a favourable dosimetry profile, comparable to those of other 18F-labelled PET tracers, and is suitable for larger clinical applications. Trial registration CEC SSM Oriente, Santiago, Chile, permit 20140520.

5.
J Nucl Med ; 62(8): 1126-1132, 2021 08 01.
Article in English | MEDLINE | ID: mdl-33419945

ABSTRACT

Palliative treatment of bone metastasis using radiolabeled bisphosphonates is a well-known concept proven to be safe and effective. A new therapeutic radiopharmaceutical for bone metastasis is 177Lu-DOTA-zoledronic acid (177Lu-DOTA-ZOL). In this study, the safety and dosimetry of a single therapeutic dose of 177Lu-DOTA-ZOL were evaluated on the basis of a series of SPECT/CT images and blood samples. Methods: Nine patients with exclusive bone metastases from metastatic castration-resistant prostate cancer (mCRPC) (70.8 ± 8.4 y) and progression under conventional therapies participated in this prospective study. After receiving 5,780 ± 329 MBq 177Lu-DOTA-ZOL, patients underwent 3-dimensional whole-body SPECT/CT imaging and venous blood sampling over 7 d. Dosimetric evaluation was performed for main organs and tumor lesions. Safety was assessed by blood biomarkers. Results:177Lu-DOTA-ZOL showed fast uptake and high retention in bone lesions and fast clearance from the bloodstream in all patients. The average retention in tumor lesions was 0.02% injected activity per gram at 6 h after injection and approximately 0.01% at 170 h after injection. In this cohort, the average absorbed doses in bone tumor lesions, kidneys, red bone marrow, and bone surfaces were 4.21, 0.17, 0.36, and 1.19 Gy/GBq, respectively. The red marrow was found to be the dose-limiting organ for all patients. A median maximum tolerated injected activity of 6.0 GBq may exceed the defined threshold of 2 Gy for the red bone marrow in individual patients (4/8). Conclusion:177Lu-DOTA-ZOL is safe and has a favorable therapeutic index compared with other radiopharmaceuticals used in the treatment of osteoblastic bone metastases. Personalized dosimetry, however, should be considered to avoid severe hematotoxicity for individual patients.


Subject(s)
Positron Emission Tomography Computed Tomography , Prostatic Neoplasms, Castration-Resistant , Heterocyclic Compounds, 1-Ring , Humans , Male , Middle Aged , Radiometry
6.
Eur J Nucl Med Mol Imaging ; 48(3): 893-903, 2021 03.
Article in English | MEDLINE | ID: mdl-32949253

ABSTRACT

INTRODUCTION: PSMA-targeted radionuclide therapy with lutetium-177 has emerged as an effective treatment option for metastatic, castration-resistant prostate cancer (mCRPC). Recently, the concept of modifying PSMA radioligands with an albumin-binding entity was demonstrated as a promising measure to increase the tumor uptake in preclinical experiments. The aim of this study was to translate the concept to a clinical setting and evaluate the safety and dosimetry of [177Lu]Lu-PSMA-ALB-56, a novel PSMA radioligand with albumin-binding properties. METHODS: Ten patients (71.8 ± 8.2 years) with mCRPC received an activity of 3360 ± 393 MBq (120-160 µg) [177Lu]Lu-PSMA-ALB-56 followed by whole-body SPECT/CT imaging over 7 days. Volumes of interest were defined on the SPECT/CT images for dosimetric evaluation for healthy tissue and tumor lesions. General safety and therapeutic efficacy were assessed by measuring blood biomarkers. RESULTS: [177Lu]Lu-PSMA-ALB-56 was well tolerated, and no severe adverse events were observed. SPECT images revealed longer circulation of [177Lu]Lu-PSMA-ALB-56 in the blood with the highest uptake in tumor lesions at 48 h post injection. Compared with published data for other therapeutic PSMA radioligands (e.g. PSMA-617 and PSMA I&T), normalized absorbed doses of [177Lu]Lu-PSMA-ALB-56 were up to 2.3-fold higher in tumor lesions (6.64 ± 6.92 Gy/GBq) and similar in salivary glands (0.87 ± 0.43 Gy/GBq). Doses to the kidneys and red marrow (2.54 ± 0.94 Gy/GBq and 0.29 ± 0.07 Gy/GBq, respectively) were increased. CONCLUSION: Our data demonstrated that the concept of albumin-binding PSMA-radioligands is feasible and leads to increased tumor doses. After further optimization of the ligand design, the therapeutic outcomes may be improved for patients with prostate cancer.


Subject(s)
Prostatic Neoplasms, Castration-Resistant , Albumins , Dipeptides , Heterocyclic Compounds, 1-Ring , Humans , Ligands , Male , Prostatic Neoplasms, Castration-Resistant/diagnostic imaging , Prostatic Neoplasms, Castration-Resistant/radiotherapy , Radiopharmaceuticals/therapeutic use , Tissue Distribution
7.
Indian J Nucl Med ; 36(4): 412-421, 2021.
Article in English | MEDLINE | ID: mdl-35125759

ABSTRACT

BACKGROUND: Optimal peptide concentration in treatment with 177Lu-DOTATOC/DOTATATE is a matter of debate. Most of the studies with peptide receptor radionuclide therapy mention peptide dose ranging between 100 and 250 µg. The aim of this is to identify possible differences in radiation-absorbed doses (D/Gy) to tumor and kidney as a function of the peptide mass dose in order to identify the most suitable peptide dose for treatment. The therapeutic index (Dtumor/Dkidneys) was assessed as a key parameter for the treatment response. MATERIALS AND METHODS: Five patients with metastasized Grade 1 to Grade 2 neuroendocrine tumor were analyzed in this study. Patients (n = 4) received two cycles of treatment with intravenously injected 177Lu-DOTATOC containing peptide mass doses of 200 µg and 90 µg, alternatively; one patient was treated with 90 µg peptide mass in both the therapy cycles. Whole-body (head to mid-thigh) three-dimensional single-photon emission computerized tomography (3D SPECT)/CT images were acquired at 1, 4, 24, 48, and 72 h following the injection of 177Lu-DOTATOC. Attenuation correction for 3D SPECT images was performed using CT data acquired and fused with the SPECT data (SPECT/CT). RESULTS: Overall, 28 target lesions (liver n = 17, lung n = 4, lymph nodes n = 1, and bone n = 2) were analyzed after 1st and 2nd therapy cycles. Tumor normalized absorbed doses varied by a factor of 74 between 0.35 and 26 mGy/MBq. Averaged over all patients, a higher normalized mean tumor dose (10.51 mGy/MBq) was achieved for a peptide dose of 200 µg compared to 90 µg (4.58 mGy/MBq). Kidneys doses varied by a factor of up to 4 between patients (0.25-1.0 mGy/MBq) (independent of dose cycle and peptide dose) and by a factor of up to 2 between dose cycles. The mean kidney dose was 13.7% higher for the 90 µg peptide dose compared to 200 µg. Given the higher tumor dose, the mean therapeutic index of a 200 µg mass dose was considerably higher (16.95), compared to a 90 µg mass dose (9.63). This coincided with the observation, that lesion volume reduction was more pronounced after an initial treatment with a 200 µg mass dose. Biologically effective dose was only 5. 1%-19.3% higher than the absorbed dose for individual dose cycles. CONCLUSIONS: Higher peptide dose of 200 µg appears to be more suitable than 90 µg in terms of tumor dose, kidney dose, and therapeutic index for treatment with 177Lu-DOTATOC.

8.
EJNMMI Phys ; 7(1): 34, 2020 May 20.
Article in English | MEDLINE | ID: mdl-32435936

ABSTRACT

BACKGROUND: This study investigated the impact of the size of the normal database on the classification performance of the specific binding ratio (SBR) in dopamine transporter (DAT) SPECT with [123I]FP-CIT in different settings. METHODS: The first subject sample comprised 645 subjects from the Parkinson's Progression Marker Initiative (PPMI), 207 healthy controls (HC), and 438 Parkinson's disease (PD) patients. The second sample comprised 372 patients from clinical routine patient care, 186 with non-neurodegenerative parkinsonian syndrome (PS) and 186 with neurodegenerative PS. Single-photon emission computed tomography (SPECT) images of the clinical sample were reconstructed with two different reconstruction algorithms (filtered backprojection, iterative ordered subsets expectation maximization (OSEM) reconstruction with resolution recovery). The putaminal specific binding ratio (SBR) was computed using an anatomical region of interest (ROI) predefined in standard (MNI) space in the Automated Anatomic Labeling (AAL) atlas or using hottest voxels (HV) analysis in large predefined ROIs. SBR values were transformed to z-scores using mean and standard deviation of the SBR in a normal database of varying sizes (n = 5, 10, 15,…, 50) randomly selected from the HC subjects (PPMI sample) or the patients with non-neurodegenerative PS (clinical sample). Accuracy, sensitivity, and specificity for identifying patients with PD or neurodegenerative PS were determined as performance measures using a predefined fixed cutoff on the z-score. This was repeated for 10,000 randomly selected normal databases, separately for each size of the normal database. Mean and 5th percentile of the performance measures over the 10,000 realizations were computed. Accuracy, sensitivity, and specificity when using the whole set of HC or non-neurodegenerative PS subjects as normal database were used as benchmark. RESULTS: Mean loss of accuracy of the putamen SBR z-score was below 1% when the normal database included at least 15 subjects, independent of subject sample (PPMI or clinical), reconstruction method (filtered backprojection or OSEM), and ROI method (AAL or HV). However, the variability of the accuracy of the putamen SBR z-score decreased monotonically with increasing size of normal database and was still considerable at size 15. In order to achieve less than 5% "maximum" loss of accuracy (defined by the 5th percentile) in all settings required at least 25 to 30 subjects in the normal database. Reduction of mean and "maximum" loss of accuracy of the putamen SBR z-score by further increasing the size of the normal database was very small beyond size 40. CONCLUSIONS: The results of this study suggest that 25 to 30 is the minimum size of the normal database to reliably achieve good performance of semi-quantitative analysis in dopamine transporter (DAT) SPECT, independent of the algorithm used for image reconstruction and the ROI method used to estimate the putaminal SBR.

9.
Eur J Nucl Med Mol Imaging ; 46(5): 1081-1091, 2019 May.
Article in English | MEDLINE | ID: mdl-30603987

ABSTRACT

PURPOSE: The aims of this study were to develop a prostate-specific membrane antigen (PSMA) ligand for labelling with different radioisotopes of lead and to obtain an approximation of the dosimetry of a simulated 212Pb-based alpha therapy using its 203Pb imaging analogue. METHODS: Four novel Glu-urea-based ligands containing the chelators p-SCN-Bn-TCMC or DO3AM were synthesized. Affinity and PSMA-specific internalization were studied in C4-2 cells, and biodistribution in C4-2 tumour-bearing mice. The most promising compound, 203Pb-CA012, was transferred to clinical use. Two patients underwent planar scintigraphy scans at 0.4, 4, 18, 28 and 42 h after injection, together with urine and blood sampling. The time-activity curves of source organs were extrapolated from 203Pb to 212Pb and the calculated residence times of 212Pb were forwarded to its unstable daughter nuclides. QDOSE and OLINDA were used for dosimetry calculations. RESULTS: In vitro, all ligands showed low nanomolar binding affinities for PSMA. CA09 and CA012 additionally showed specific ligand-induced internalization of 27.4 ± 2.4 and 15.6 ± 2.1 %ID/106 cells, respectively. The 203Pb-labelled PSMA ligands were stable in serum for 72 h. In vivo, CA012 showed higher specific uptake in tumours than in other organs, and particularly showed rapid kidney clearance from 5.1 ± 2.5%ID/g at 1 h after injection to 0.9 ± 0.1%ID/g at 24 h. In patients, the estimated effective dose from 250-300 MBq of diagnostic 203Pb-CA012 was 6-7 mSv. Assuming instant decay of daughter nuclides, the equivalent doses projected from a therapeutic activity of 100 MBq of 212Pb-CA012 were 0.6 SvRBE5 to the red marrow, 4.3 SvRBE5 to the salivary glands, 4.9 SvRBE5 to the kidneys, 0.7 SvRBE5 to the liver and 0.2 SvRBE5 to other organs; representative tumour lesions averaged 13.2 SvRBE5 (where RBE5 is relative biological effectiveness factor 5). Compared to clinical experience with 213Bi-PSMA-617 and 225Ac-PSMA-617, the projected maximum tolerable dose was about 150 MBq per cycle. CONCLUSION: 212Pb-CA012 is a promising candidate for PSMA-targeted alpha therapy of prostate cancer. The dosimetry estimate for radiopharmaceuticals decaying with the release of unstable daughter nuclides has some inherent limitations, thus clinical translation should be done cautiously.


Subject(s)
Alpha Particles/therapeutic use , Antigens, Surface/metabolism , Glutamate Carboxypeptidase II/metabolism , Lead Radioisotopes/therapeutic use , Animals , Cell Line, Tumor , Humans , Isotope Labeling , Ligands , Mice , Radiometry
10.
J Nucl Med ; 60(3): 386-392, 2019 03.
Article in English | MEDLINE | ID: mdl-30072500

ABSTRACT

Fibroblast activation protein (FAP) is overexpressed in cancer-associated fibroblasts of several tumor entities. The recent development of quinoline-based PET tracers that act as FAP inhibitors (FAPIs) demonstrated promising results preclinically and already in a few clinical cases. Consequently, these tracers are now applied in our hospital to amend the diagnostics of cancer patients facing the limitations of standard examinations. Here, we analyze the tissue biodistribution and preliminary dosimetry of 2 members of this new class of PET radiopharmaceutical. Methods: A preliminary dosimetry estimate for 68Ga-FAPI-2 and 68Ga-FAPI-4 was based on 2 patients examined at 0.2, 1, and 3 h after tracer injection using the QDOSE dosimetry software suit. Further PET/CT scans of tumor patients were acquired 1 h after injection of either 68Ga-FAPI-2 (n = 25) or 68Ga-FAPI-4 (n = 25); for 6 patients an intraindividual related 18F-FDG scan (also acquired 1 h after injection) was available. For the normal tissue of 16 organs, a 2-cm spheric volume of interest was placed in the parenchyma; for tumor lesions, a threshold-segmented volume of interest was used to quantify SUVmean and SUVmaxResults: Similar to literature values for 18F-FDG, 68Ga-DOTATATE, and 68Ga-PSMA-11, an examination with 200 MBq of 68Ga-FAPI-2 or 68Ga-FAPI-4 corresponds to an equivalent dose of approximately 3-4 mSv. After a fast clearance via the kidneys, the normal organs showed a low tracer uptake with only minimal changes between 10 min and 3 h after injection. In 68Ga-FAPI-2, the tumor uptake from 1 to 3 h after injection decreased by 75%, whereas the tumor retention was prolonged with 68Ga-FAPI-4 (25% washout). Regarding tumor-to-background ratios, at 1 h after injection both 68Ga-FAPI tracers performed equally. In comparison to 18F-FDG, the tumor uptake was almost equal (average SUVmax, 7.41 for 18F-FDG and 7.37 for 68Ga-FAPI-2; not statistically significant); the background uptake in brain (11.01 vs. 0.32), liver (2.77 vs. 1.69), and oral/pharyngeal mucosa (4.88 vs. 2.57) was significantly lower with 68Ga-FAPI. Other organs did not relevantly differ between 18F-FDG and 68Ga-FAPI. Conclusion: FAPI PET/CT is a new diagnostic method in imaging cancer patients. In contrast to 18F-FDG, no diet or fasting in preparation for the examination is necessary, and image acquisition can potentially be started a few minutes after tracer application. Tumor-to-background contrast ratios were equal to or even better than those of 18F-FDG.


Subject(s)
Gallium Radioisotopes , Gelatinases/metabolism , Membrane Proteins/metabolism , Neoplasms/diagnostic imaging , Neoplasms/metabolism , Positron Emission Tomography Computed Tomography/methods , Serine Endopeptidases/metabolism , Serine Proteinase Inhibitors/chemistry , Serine Proteinase Inhibitors/pharmacokinetics , Adult , Aged , Aged, 80 and over , Endopeptidases , Female , Humans , Male , Middle Aged , Radiometry , Radiopharmaceuticals/chemistry , Radiopharmaceuticals/metabolism , Radiopharmaceuticals/pharmacokinetics , Serine Proteinase Inhibitors/metabolism , Tissue Distribution
11.
Neuroimage ; 60(4): 2144-57, 2012 May 01.
Article in English | MEDLINE | ID: mdl-22387126

ABSTRACT

Accurate quantification of PET imaging data is required for a useful interpretation of the measured radioactive tracer concentrations. The partial volume effect (PVE) describes signal dilution and mixing due to spatial resolution and sampling limitations, which introduces bias in quantitative results. In the present study we investigated the magnitude of PVE for volumes of interest (VOIs) in the rat brain and the effect of positron range. In simulated (11)C-raclopride studies we examined the influence of PVE on time activity curves in striatal and cerebellar VOIs and binding potential estimation. The performance of partial volume correction (PVC) was studied using the region-based geometric transfer matrix (GTM) method including the question of whether a spatially variant point spread function (PSF) is necessary for PVC of a rat brain close to the centre of the field of view. Furthermore, we determined the effect of spillover from activity outside the brain. The results confirmed that PVE is significant in rat brain PET and showed that positron range is an important factor that needs to be included in the PSF. There was considerable bias in time activity curves for the simulated (11)C-raclopride studies and significant underestimation of binding potential even for very small centred VOIs. Good activity recovery was achieved with the GTM PVC using a spatially invariant simulated PSF when no activity was present outside the brain. PVC using a simple Gaussian fit point spread function was not sufficiently accurate. Spillover from regions outside the brain had a significant impact on measured activity concentrations and reduced the accuracy of PVC with the GTM method using rat brain regions alone, except for the smallest VOI size but at the cost of increased noise. Voxel-based partial volume correction methods which inherently compensate for spillover from outside the brain might be a more suitable choice.


Subject(s)
Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Positron-Emission Tomography/methods , Algorithms , Animals , Phantoms, Imaging , Raclopride/pharmacology , Radiopharmaceuticals/pharmacology , Rats
12.
Phys Med Biol ; 56(11): 3313-35, 2011 Jun 07.
Article in English | MEDLINE | ID: mdl-21558591

ABSTRACT

Monte Carlo simulation codes that model positron interactions along their tortuous path are expected to be accurate but are usually slow. A simpler and potentially faster approach is to model positron range from analytical annihilation density distributions. The aims of this paper were to efficiently implement and validate such a method, with the addition of medium heterogeneity representing a further challenge. The analytical positron range model was evaluated by comparing annihilation density distributions with those produced by the Monte Carlo simulator GATE and by quantitatively analysing the final reconstructed images of Monte Carlo simulated data. In addition, the influence of positronium formation on positron range and hence on the performance of Monte Carlo simulation was investigated. The results demonstrate that 1D annihilation density distributions for different isotope-media combinations can be fitted with Gaussian functions and hence be described by simple look-up-tables of fitting coefficients. Together with the method developed for simulating positron range in heterogeneous media, this allows for efficient modelling of positron range in Monte Carlo simulation. The level of agreement of the analytical model with GATE depends somewhat on the simulated scanner and the particular research task, but appears to be suitable for lower energy positron emitters, such as (18)F or (11)C. No reliable conclusion about the influence of positronium formation on positron range and simulation accuracy could be drawn.


Subject(s)
Electrons , Models, Theoretical , Monte Carlo Method , Positron-Emission Tomography/methods , Animals , Image Processing, Computer-Assisted , Normal Distribution , Positron-Emission Tomography/instrumentation , Reproducibility of Results
13.
Phys Med Biol ; 51(16): 4003-16, 2006 Aug 21.
Article in English | MEDLINE | ID: mdl-16885620

ABSTRACT

An accurate, low noise estimate of photon attenuation in the subject is required for quantitative microPET studies of molecular tracer distributions in vivo. In this work, several transmission-based measurement techniques were compared, including coincidence mode with and without rod windowing, singles mode with two different energy sources ((68)Ge and (57)Co), and postinjection transmission scanning. In addition, the effectiveness of transmission segmentation and the propagation of transmission bias and noise into the emission images were examined. The (57)Co singles measurements provided the most accurate attenuation coefficients and superior signal-to-noise ratio, while (68)Ge singles measurements were degraded due to scattering from the object. Scatter correction of (68)Ge transmission data improved the accuracy for a 10 cm phantom but over-corrected for a mouse phantom. (57)Co scanning also resulted in low bias and noise in postinjection transmission scans for emission activities up to 20 MBq. Segmentation worked most reliably for transmission data acquired with (57)Co but the minor improvement in accuracy of attenuation coefficients and signal-to-noise may not justify its use, particularly for small subjects. We conclude that (57)Co singles transmission scanning is the most suitable method for measured attenuation correction on the microPET Focus 220 animal scanner.


Subject(s)
Artifacts , Equipment Failure Analysis , Image Enhancement/instrumentation , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Positron-Emission Tomography/instrumentation , Positron-Emission Tomography/veterinary , Algorithms , Equipment Design , Information Storage and Retrieval/methods , Positron-Emission Tomography/methods , Reproducibility of Results , Sensitivity and Specificity