1.
Europace ; 18(1): 78-84, 2016 Jan.
Article in English | MEDLINE | ID: mdl-25883082

ABSTRACT

BACKGROUND: Silent cerebral lesions with the multielectrode-phased radiofrequency (RF) pulmonary vein ablation catheter (PVAC(®)) have recently been investigated. However, comparative data on safety in relation to irrigated RF ablation are missing. METHODS AND RESULTS: One hundred and fifty consecutive patients (58 ± 12 years, 56 female) underwent first pulmonary vein isolation (PVI) for atrial fibrillation (61% paroxysmal) using PVAC(®) (PVAC). Procedure data as well as in-hospital complications were compared with 300 matched patients who underwent PVI using irrigated RF (iRF). Procedure duration (148 ± 63 vs. 208 ± 70 min; P < 0.001), RF duration (24 ± 10 vs. 49 ± 25 min; P < 0.001), and fluoroscopy time (21 ± 10 vs. 35 ± 13 min; P < 0.001) were significantly shorter using PVAC. Major complication rates [major bleeding, transitoric ischaemic attack (TIA), and pericardial tamponade] were not significantly different between groups (PVAC, n = 3; 2% vs. iRF n = 17; 6%). Overall complication rate, including minor events, was similar in both groups [n = 21 (14%) vs. n = 48 (16%)]. Most of these were bleeding complications due to vascular access [n = 8 (5.3%) vs. n = 22 (7.3%)], which required surgical intervention in five patients [n = 1 (0.7%) vs. n = 4 (1.3%)]. Pericardial effusion [n = 4 (2.7%) vs. n = 19 (6.3%); pericardial tamponade requiring drainage n = 0 vs. n = 6] occurred more frequently using iRF. Two patients in each group developed a TIA (1.3% vs. 0.6%). Of note, four of five thromboembolic events in the PVAC group (two TIAs and three transient ST elevations during ablation) occurred when all 10 electrodes were used for ablation. CONCLUSION: Pulmonary vein isolation using PVAC as a 'one-shot-system' has a comparable complication rate but a different risk profile. Pericardial effusion and tamponade occurred more frequently using iRF, whereas thromboembolic events were more prevalent using PVAC. Occurrence of clinically relevant thromboembolic events might be reduced by avoidance of electrode 1 and 10 interaction and uninterrupted anticoagulation, whereas contact force sensing for iRF might minimize pericardial effusion.


Subject(s)
Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Catheter Ablation/instrumentation , Postoperative Complications/epidemiology , Pulmonary Veins/surgery , Therapeutic Irrigation/instrumentation , Catheter Ablation/statistics & numerical data , Comorbidity , Electrodes , Equipment Design , Equipment Failure , Equipment Failure Analysis , Female , Heart Conduction System/surgery , Humans , Male , Middle Aged , Prevalence , Retrospective Studies , Risk Factors , Therapeutic Irrigation/statistics & numerical data , Treatment Outcome
2.
Clin Res Cardiol ; 104(3): 234-40, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25336357

ABSTRACT

BACKGROUND: Clinically silent lesions on cerebral magnet resonance imaging have been found in larger numbers after pulmonary vein isolation (PVI) especially with phased radio frequency (pRF) using all ten electrodes. However, the neuropsychological effects of cerebral microembolism during the procedure remain unclear and data regarding this issue so far are inconsistent. METHODS: Between August 2011 and June 2012, 76 patients undergoing their first PVI were randomized to ablation with either phased (40) or irrigated (36) radio frequency (iRF). A comprehensive neuropsychological test battery was performed the day before and after PVI as well as 6 months after ablation. The occurrence of cerebral microemboli during the procedure was performed via a transcranial Doppler ultrasound device. RESULTS: PVI using pRF was associated with increased number of microembolic signals (MES) compared to iRF (1530.0 ± 979.8 vs. 645.7 ± 448.7; p < 0.001). Neuropsychological assessment did not reveal any changes in correlation with the used ablation technique. Besides an age-related effect there was a diffuse, sub-clinical impairment of neurologic function depending on age and the number of MES. CONCLUSIONS: There was no clinical overt cognitive deficit and no significant difference in cognitive function correlating with the used ablation technique. The number of MES correlated with a subtle, diffuse post-procedural impairment of neuropsychological function highlighting the need to reduce microemboli during ablation.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Cognition Disorders/psychology , Cognition , Intracranial Embolism/psychology , Aged , Atrial Fibrillation/diagnosis , Catheter Ablation/methods , Cognition Disorders/diagnosis , Cognition Disorders/etiology , Female , Germany , Humans , Intracranial Embolism/diagnosis , Intracranial Embolism/etiology , Male , Middle Aged , Neuropsychological Tests , Predictive Value of Tests , Prospective Studies , Risk Factors , Therapeutic Irrigation/adverse effects , Time Factors , Treatment Outcome , Ultrasonography, Doppler, Transcranial