Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
Diagnostics (Basel) ; 14(11)2024 May 31.
Article in English | MEDLINE | ID: mdl-38893692

ABSTRACT

BACKGROUND: Numerous immunoassays have been commercialized to determine pancreatic elastase (PE) in feces in screening for exocrine pancreatic insufficiency (EPI), but how the different assays compare to one another is controversial, especially in the context that all methods use the same cut-off values for interpreting the results obtained on the presence or absence of EPI or the degree of insufficiency if it is present. Our aim was to analytically verify a new method for determining PE, compare the results with a previous method, and verify the declared cut-off values for interpretation of the results. METHODS: PE in the stool was assayed using a previous monoclonal enzyme-linked immunosorbent assay ("ScheBo ELISA") and a new polyclonal particle-enhanced turbidimetric immunoassay ("Bühlmann PETIA"). The direct method comparison of two immunoassays was performed in 40 samples. Clinical comparisons were conducted against each other for the binary determination of "abnormal/normal" elastase levels and the three-way determination of "severe/moderate/no" EPI in 56 samples. The indirect comparison method used external quality assessment (EQA) data to compare the monoclonal and polyclonal immunoassays for PE, and additionally compare the monoclonal ScheBo ELISA to a monoclonal chemiluminescence immunoassay ("DiaSorin CLIA"). RESULTS: Precision in the series and intra-laboratory precision for Bühlmann PETIA met the manufacturer's specifications for the concentration range of limit/lower values and the range of normal values. The Bühlmann PETIA immunoassay on different analytical platforms yielded comparable results and nearly perfect agreement in the case of three-way classification (kappa = 0.89 with 95%CI from 0.79 to 1.00. ScheBo ELISA tends to generate higher values of pancreatic elastase than the Bühlmann PETIA; agreement between the methods was moderate in the case of binary classification (kappa = 0.43; 95% CI 0.25 to 0.62), and substantial in the case of three-way classification (kappa = 0.62; 95% CI 0.50 to 0.75). EQA data analysis showed a statistically significant difference between ScheBo ELISA and Bühlmann PETIA peer groups (p = 0.031), as well as the DiaSorin CLIA and ScheBo ELISA peer groups (p = 0.010). CONCLUSION: The ScheBo ELISA and Bühlmann PETIA do not appear to be commutable in the analytical and clinical context. Our data address a discordance between different mono- and polyclonal immunoassays for pancreatic elastase and the potential of misclassification using its universal cut-off values in screening suspected patients for exocrine pancreatic insufficiency.

2.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38535043

ABSTRACT

BACKGROUND: Among malignant diseases which develop during childhood, hematological cancers, such as leukemias and lymphomas, are the most common. Outcomes have greatly improved due to the refinement of multiagent chemotherapy regimens that include enhanced asparaginase therapy. In this study, we aimed to evaluate our experiences related to the analytical and clinical significance of determining l-Asparaginase activity. METHODS: Since 2016, the Laboratory of the Children's Hospital Zagreb has routinely measured l-Asparaginase activity and to date, has measured more than 280 examples of activity in a total of 57 children with hematological malignancy treated at the Pediatric Oncology Department of the Children's Hospital Zagreb. Three asparaginase products were available: native E. colil-Asparaginase; a pegylated form of this enzyme; and a native product from Erwinia chrysanthemi. A retrospective data analysis was performed. RESULTS: Out of the fifty-seven children, seven had an allergic reaction (12.3%), five (8.8%) had silent inactivation, and seven (12.3%) developed acute pancreatitis. Allergic reactions and silent inactivation were more common in children treated with native E. colil-Asparaginase, while pancreatitis was more common in children treated with the pegylated form. CONCLUSIONS: The monitoring of l-Asparaginase activity may help to optimize therapy by identifying patients with 'silent inactivation', and/or by dose correction when l-Asparaginase activity is too high (slow elimination).

3.
Biochem Med (Zagreb) ; 33(2): 020703, 2023 Jun 15.
Article in English | MEDLINE | ID: mdl-37324112

ABSTRACT

Introduction: The aim of this study was to perform a verification of the Dymind D7-CRP automated analyser and compare it with established analysers. Materials and methods: Analytical verification included estimation of repeatability, between run precision, within-laboratory precision, and bias in control samples with low, normal and high levels. The acceptance criteria for analytical verification were defined using the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) 2019 Biological Variation Database. Method comparison between the Dymind D7-CRP and the Sysmex XN1000 for haematological parameters and the Dymind D7-CRP and the Beckman Coulter AU680 for CRP values was performed on 40 patient samples. Results: Analytical verification criteria were adequately met with the exception of monocyte count for repeatability and within-laboratory precision (13.4% and 11.5%, respectively, acceptance criteria 10.1%) and measurement uncertainty (23.0, acceptance criteria 20.0%) at low level, eosinophil count for BIAS at the low level (37.7%, acceptance criteria 25.2%), basophil count (BAS) for BIAS at the high level (14.2%, acceptance criteria 10.9%), and mean platelet volume (MPV) for repeatability (4.2% and 6.8%), between run precision (2.2% and 4.7%), within-laboratory precision (4.0% and 7.3%) (acceptance criteria 1.7%), and measurement uncertainty (8.0 and 14.6%, acceptance criteria 3.4%) at both the low and high concentrations. Method comparison showed no clinically significant constant or proportional differences for all parameters except BAS and MPV. Conclusion: The analytical verification of the Dymind D7-CRP showed adequate analytical characteristics. The Dymind D7-CRP can be used interchangeably with the Sysmex XN-1000 for all parameters tested, except BAS and MPV, and with the Beckman Coulter AU-680 for the determination of CRP.


Subject(s)
Mean Platelet Volume , Humans , Leukocyte Count
4.
Biochem Med (Zagreb) ; 32(3): 030706, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-36277428

ABSTRACT

Introduction: Overactive bladder (OAB) is the most common urinary disorder and the leading cause of functional daytime intermittent urinary incontinence in children. The aim of this study was to determine whether urinary brain-derived neurotrophic factor (BDNF) and nerve growth factor (NGF) concentrations, normalized to urine creatinine, could be used as biomarkers for diagnosis and treatment monitoring of OAB in children. Materials and methods: Urine samples of 48 pediatric patients with OAB were collected at the start of anticholinergic therapy (baseline), at follow-up visits (3 and 6 months), and from 48 healthy controls. Urinary BDNF and NGF concentrations were determined by ELISA method (Merck, Darmstadt, Germany) and Luminex method (Thermo Fisher Scientific, Waltham, USA). Differences of frequency between quantifiable analyte concentrations between subject groups were determined using Fisher's exact test. Results: There was no statistically significant difference between quantifiable analyte concentrations between patients at baseline and the control group for BDNF and NGF by either the ELISA or Luminex method (P = 1.000, P = 0.170, P = 1.000, and P = N/A, respectively). There was a statistically significant difference between quantifiable BDNF by the ELISA method between patients at baseline and complete success follow-up (P = 0.027), while BDNF by Luminex method and NGF by both methods were not statistically significant (P = 0.078, P = 0.519, and P = N/A, respectively). Conclusions: This study did not demonstrate that urinary BDNF and NGF concentrations, can be used as biomarkers for diagnosis and therapy monitoring of OAB in children.


Subject(s)
Urinary Bladder, Overactive , Humans , Child , Urinary Bladder, Overactive/diagnosis , Urinary Bladder, Overactive/therapy , Nerve Growth Factor/urine , Brain-Derived Neurotrophic Factor/urine , Creatinine/urine , Biomarkers/urine , Cholinergic Antagonists
5.
Biochem Med (Zagreb) ; 32(3): 030702, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-35966262

ABSTRACT

Introduction: Laboratory plays important part in screening, diagnosis, and management of thyroid disorders. The aim of this study was to estimate current laboratory preanalytical, analytical and postanalytical practices and policies in Croatia. Materials and methods: Working Group for Laboratory Endocrinology of the Croatian Society of Medical Biochemistry and Laboratory Medicine designed a questionnaire with 27 questions and statements regarding practices and protocols in measuring thyroid function tests. The survey was sent to 111 medical biochemistry laboratories participating in external quality assurance scheme for thyroid hormones organized by Croatian Centre for Quality Assessment in Laboratory Medicine. Data is presented as absolute numbers and proportions. Results: Fifty-three participants returned the questionnaire. Response rate varied depending on question, yielding a total survey response rate of 46-48%. All respondents perform thyroid stimulating hormone (TSH). From all other thyroid tests, most performed is free thyroxine (37/53) and least TSH-stimulating immunoglobulin (1/53). Laboratories are using nine different immunoassay methods. One tenth of laboratories is verifying manufacturer's declared limit of quantification for TSH and one third is verifying implemented reference intervals for all performed tests. Most of laboratories (91%) adopt the manufacturer's reference interval for adult population. Reference intervals for TSH are reported with different percentiles (90, 95 or 99 percentiles). Conclusion: This survey showed current practices and policies in Croatian laboratories regarding thyroid testing. The results identified some critical spots and will serve as a foundation in creating national guidelines in order to harmonize laboratory procedures in thyroid testing in Croatia.


Subject(s)
Laboratories , Thyroid Function Tests , Croatia , Humans , Policy , Surveys and Questionnaires , Thyrotropin
6.
Cureus ; 14(1): e21711, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35242477

ABSTRACT

Achromobacter xylosoxidans is an aerobic, Gram-negative rod with a broad intrinsic and acquired antimicrobial resistance, usually isolated in patients with cystic fibrosis (CF), immunodeficiencies, or those undergoing invasive procedures. We report a case of a previously healthy 14-year-old girl who was hospitalized in our institution due to a prolonged, progressive cough and exertional dyspnea, which started after a mild viral respiratory tract infection. To elucidate the cause of her symptoms, a bronchoscopy was finally performed, showing bilateral purulent bronchitis caused by A. xylosoxidans, isolated from bronchoalveolar lavage (BAL) sample. Since the patient had positive serological testing for coronavirus disease 2019 (COVID-19), we concluded that it was the initial viral infection, although of a mild clinical course, the one that created favorable conditions for proliferation and further inflammation caused by A. xylosoxidans.

7.
Biochem Med (Zagreb) ; 32(1): 010501, 2022 Feb 15.
Article in English | MEDLINE | ID: mdl-35210925

ABSTRACT

The sweat test (ST) is a cornerstone in the diagnosis of cystic fibrosis (CF), together with newborn screening and genetic testing. However, the performance of the ST can depend on the operator's skill, so several international guidelines have been published to standardise the ST, but inconsistencies remain. The joint Working Group for ST Standardisation (WG STS) of the Croatian Society of Medical Biochemistry and Laboratory Medicine, in association with cistic fybrosis health professional and the Cistic Fibrosis Centre for Paediatrics and Adults, have issued National Guidelines for the Performance of the Sweat Test in order to ensure consistency in ST performance and accuracy of reported results. Many of the standards were taken from the 2nd Edition of the UK Guidelines for Performance of the ST for the Diagnosis of CF, while others were taken from independent consensus statements from the WG STS based on local ST equipment and practices. The standards cover every step of the ST, from the indications for testing to reporting of results and their interpretation, including the analytical phase and quality control. In addition, National Guidelines include appendices with practical examples in order to aid implementation of the recommendations in routine practice.


Subject(s)
Cystic Fibrosis , Pediatrics , Child , Cystic Fibrosis/diagnosis , Hospitals, University , Humans , Infant, Newborn , Laboratories , Sweat
8.
Biochem Med (Zagreb) ; 32(1): 010901, 2022 Feb 15.
Article in English | MEDLINE | ID: mdl-34955674

ABSTRACT

INTRODUCTION: Interpretation of laboratory test results is a complex post-analytical activity that requires not only understanding of the clinical significance of laboratory results but also the analytical phase of laboratory work. The aims of this study were to determine: 1) the general opinion of Croatian medical biochemistry laboratories (MBLs) about the importance of interpretative comments on laboratory test reports, and 2) to find out whether harmonization of interpretative comments is needed. MATERIALS AND METHODS: This retrospective study was designed as a survey by the Working Group for Post-analytics as part of national External Quality Assessment (EQA) program. All 195 MBLs participating in the national EQA scheme, were invited to participate in the survey. Results are reported as percentages of the total number of survey participants. RESULTS: Out of 195 MBLs, 162 participated in the survey (83%). Among them 59% MBLs implemented test result comments in routine according to national recommendations. The majority of laboratories (92%) state that interpretative comments added value to the laboratory reports, and a substantial part (72%) does not have feedback from physicians on their significance. Although physicians and patients ask for expert opinion, participants stated that the lack of interest of physicians (64%) as well as the inability to access patient's medical record (62%) affects the quality of expert opinion. CONCLUSION: Although most participants state that they use interpretative comments and provide expert opinions regarding test results, results of the present study indicate that harmonization for interpretative comments is needed.


Subject(s)
Biochemistry , Laboratories , Humans , Medical Records , Retrospective Studies , Surveys and Questionnaires
9.
Biochem Med (Zagreb) ; 31(3): 030704, 2021 Oct 15.
Article in English | MEDLINE | ID: mdl-34658645

ABSTRACT

INTRODUCTION: The detection and prevention of errors in the postanalytical phase can be done through the harmonization and standardization of constituent parts of this phase of laboratory work. The aim was to investigate how well the ongoing management of the postanalytical phase corresponds to the document "Post-analytical laboratory work: national recommendations" in Croatian medical biochemistry laboratories (MBLs). MATERIALS AND METHODS: All 195 MBLs participating in the national external quality assessment scheme, were invited to undertake a part in a survey. Through 23 questions the participants were asked about management of the reference intervals (RI), delta check, reflex/reflective testing, postanalytical quality indicators and other parts of the postanalytical phase recommended in the national recommendations. The results are presented in numbers and percentages. RESULTS: Out of 195 MBLs, 119 participated in the survey, giving a response rate of 61%. Not all of the respondents provided answers to all the questions. Delta check has not been used in 59% (70/118) of the laboratories. Only 22/113 (20%) laboratories use reflex and/or reflective testing. In 53% of the laboratories, critical results were reported within 30 minutes of the confirmation of the results. In 34% (40/118) of the laboratories, turnaround time and reporting of critical results are two most often monitored postanalytical quality indicators. CONCLUSION: The results showed the critical results reporting and monitoring of postanalytical quality indicators are in the line with the recommendations. However, the management of RI verification, the use of delta check and reflex/reflective testing still must be harmonized among Croatian MBLs.


Subject(s)
Biochemistry , Laboratories , Clinical Laboratory Techniques , Humans , Longitudinal Studies , Surveys and Questionnaires
10.
Biochem Med (Zagreb) ; 31(2): 020708, 2021 Jun 15.
Article in English | MEDLINE | ID: mdl-34140831

ABSTRACT

INTRODUCTION: Activated partial thromboplastin time (aPTT) is determined and reported as clotting time in seconds aPTT(s), but it is presumed that reporting results as patient-to-normal clotting time ratio, aPTT(r), could minimize within-laboratory variability. The aim of study was to investigate differences in reporting aPTT results that can affect comparability of the results among Croatian laboratories and suggest further steps for its harmonization. MATERIALS AND METHODS: The questionnaire on aPTT reporting practice was distributed to 83 laboratories through Survey Monkey application in March 2019 as the part of the first regular round of Croatian Centre for Quality Assessment in Laboratory Medicine proficiency testing. RESULTS: The survey response rate was 0.49. Majority of laboratories report aPTT results as both, seconds and ratio. Participants reported use of 23 different aPTT(s) reference intervals along with 17 different combinations of reagent/coagulometer and 25 aPTT(s) denominators of different origin for aPTT(r) calculation. Despite the same aPTT(s) results, the use of different denominators caused a dispersion of aPTT(r) results that can lead to exceeding external quality assessment performance criteria of 7%, particularly when results were compared for the same reagent group only. By applying aPTT(s) reference interval mean as denominator for calculation of aPTT(r) reference interval better concordance to harmonized one was obtained (17 vs. 27; χ2 = 3.972; P = 0.046). CONCLUSION: In order to improve comparability of the results, laboratories are advised to use mean of aPTT(s) reference interval as denominator for aPTT(r) calculation. Type of coagulometer need to be considered when evaluating aPTT proficiency test results and its currently acceptable limit of performance evaluated accordingly.


Subject(s)
Partial Thromboplastin Time , Surveys and Questionnaires , Croatia , Humans , Reference Values
11.
Biochem Med (Zagreb) ; 31(2): 020706, 2021 Jun 15.
Article in English | MEDLINE | ID: mdl-33927556

ABSTRACT

INTRODUCTION: The study aimed to investigate the prevalence and titres of anti-SARS-CoV-2 antibodies in children treated at the Children's Hospital Zagreb in the first and the second wave of the COVID-19 pandemic. Statistical significance of difference at two time points was done to determine how restrictive epidemiological measures and exposure of children to COVID-19 infection affect this prevalence in different age groups. MATERIALS AND METHODS: At the first time point (13th to 29th May 2020), 240 samples and in second time point (24th October to 23rd November 2020), 308 serum samples were tested for anti-SARS-CoV-2 antibodies by enzyme-linked immunosorbent assay (ELISA) and electrochemiluminescence immunoassay (ECLIA). Confirmation of results and titre determination was done using virus micro-neutralization test. Subjects were divided according to gender, age and epidemiological history. RESULTS: Seroprevalence of anti-SARS-CoV-2 antibodies differs significantly in two time points (P = 0.010). In first time point 2.9% of seropositive children were determined and in second time point 8.4%. Statistically significant difference (P = 0.007) of seroprevalence between two time points was found only in a group of children aged 11-19 years. At the first time point, all seropositive children were asymptomatic with titre < 8. At the second time point, 69.2% seropositive children were asymptomatic with titre ≥ 8. CONCLUSIONS: The prevalence of anti-SARS-CoV-2 antibodies was significantly lower at the first time point than at the second time point. Values of virus micro-neutralization test showed that low titre in asymptomatic children was not protective at the first time point but in second time point all seropositive children had protective titre of anti-SARS-CoV-2 antibodies.


Subject(s)
Antibodies, Viral/blood , COVID-19/diagnosis , SARS-CoV-2/immunology , Adolescent , COVID-19/epidemiology , COVID-19/virology , Child , Child, Preschool , Croatia/epidemiology , Enzyme-Linked Immunosorbent Assay , Female , Hospitals , Humans , Infant , Male , Pandemics , SARS-CoV-2/isolation & purification
12.
J Med Biochem ; 40(2): 138-149, 2021 Mar 12.
Article in English | MEDLINE | ID: mdl-33776563

ABSTRACT

BACKGROUND: In the final phase of clot formation, fibrinogen constitutes frame, whereas factor XIII (FXIII) active form is responsible for the covalent cross-linking of fibrin fibres and plasmin inhibitor (PI), thus contributing to clot stability. It could be expected that any change of coagulation factors' structure affects the clot formation and modulates the atherothrombotic risk. The aim was to determine the frequency of four single nucleotide polymorphisms: (i) A > G in codon 312 of the fibrinogen α-chain gene (rs6050, Thr312AlaFGA), (ii) C > T at position 10034 of the 3 - untranslated region in the fibrinogen γ-chain gene (rs2066865, 10034C > T FGG), (iii) C > T in codon 564 of the FXIII-A subunit gene (rs5982, Pro564LeuFXIII-A), and (iv) C > T in codon 6 of the plasmin inhibitor gene (rs2070863, Arg6TrpPI) in Croatian patients and their association with coronary artery disease (CAD). METHODS: We performed the unrelated case-control association study on the consecutive sample of patients 18 years old, who had undergone coronary angiography for investigation of chest pain and suspected CAD. The cases were patients with confirmed CAD (N=201), and the controls were the subjects with no CAD (N=119). Samples were genotyped using PCR-RFLP analysis. RESULTS: Observed frequencies of the rare alleles of Thr312Ala FGA, 10034C > T FGG, Leu564Pro FXIII-A and Arg6Trp PI polymorphisms were 21%, 17%, 14%, 20%, respectively. Patients with 10034C > T FGG CC genotype had 3.5 times (95% CI 1.02-12.03) higher adjusted odds for CAD than patients with 10034C > T FGG TT genotype. Patients with Arg6Trp PI CC genotype had 3.86 times (95% CI 1.23-12.12) higher odds for CAD than patients with Arg6Trp PI TT genotype. It seems that those genotype-related higher odds are also male-gender related. No difference was observed regarding any other investigated polymorphism. CONCLUSIONS: Our finding suggests that 10034C > T FGG and Arg6Trp PI are associated with CAD.

13.
Acta Dermatovenerol Croat ; 29(4): 175-183, 2021 Nov.
Article in English | MEDLINE | ID: mdl-36896687

ABSTRACT

Fecal calprotectin (FCP) is a biomarker of intestinal inflammation and has recently been proposed as a diagnostic biomarker of food allergy (FA) in children. The aim of this study was to compare FCP level in infants and children under 4 years old with 1) atopic dermatitis (AD) with food allergy (FA) and 2) children with AD and without FA with the results in healthy controls. In total, 46 infants and children (mean age 14 months ± 12) diagnosed with AD were divided into two groups: G1, children with atopic AD with FA (n=28) and G2, children with AD without FA (n=18). The control group (G3) was made up of healthy children of the same age (n=18). The median FCP was significantly higher in G1 compared with G2 (G1: median 154, IQR 416 µg/g vs G2: median 41.3, IQR 59 µg/g; P=0.0096). The median FCP in children with AD and FA was significantly higher before elimination diet in comparison with FCP after 3 months of elimination diet (median 154, IQR 416 µg/g vs median 35, IQR 23 µg/g; P=0.0039). The level of FCP was significantly positively correlated with the SCORAD score (r=0.5544, P=0.0022). Our study showed a significant difference in level of FCP in patients with AD without FA compared with patients with AD and FA. We also found a positive correlation of FCP with SCORAD score, a biomarker of AD severity. New studies are needed to investigate the role of FCP as a biomarker of FA in children with AD.


Subject(s)
Dermatitis, Atopic , Food Hypersensitivity , Infant , Child , Humans , Child, Preschool , Dermatitis, Atopic/diagnosis , Leukocyte L1 Antigen Complex , Food Hypersensitivity/complications , Food Hypersensitivity/diagnosis , Patient Acuity , Biomarkers
14.
Biochem Med (Zagreb) ; 30(2): 020710, 2020 Jun 15.
Article in English | MEDLINE | ID: mdl-32550818

ABSTRACT

INTRODUCTION: The aim of this study was to examine whether the Canadian Laboratory Initiative on Paediatric Reference Intervals (CALIPER) could be applied to Croatian children and adolescents. MATERIALS AND METHODS: A total of 295 outpatient healthy children and adolescents of age 1 to 18 were selected using the direct a posteriori sampling method. According to current guidelines, 20 samples were tested for each of a total of 51 reference intervals for ferritin, cortisol, dehydroepiandrosterone sulfate, follicle stimulating hormone, lutein stimulating hormone, prolactin, progesterone, sex hormone binding globulin, thyroid stimulating hormone, total testosterone, total thyroxine and total triiodothyronine. Serum samples were analysed on the Beckman Coulter DxI600 immunoassay analyser by chemiluminescence immunoassay method. A reference interval was adopted if < 10% of the results fall outside CALIPER reference interval range. For analytes in which this criterion is not met in the first set of samples, a new set of 20 samples were collected. RESULTS: After the first set of measurements, 96% of all tested reference intervals were adopted for use. The additional sets of 20 reference subjects were tested for only two reference intervals; follicle stimulating hormone for female aged 1 to 9 years, and irrespective of the gender, sex hormone binding globulin for children aged 8 to 11 years. All results of additional samples were within the specified interval limits. CONCLUSIONS: CALIPER reference intervals for ferritin and 11 hormones defined for Beckman Coulter DxI600 immunoassay analyser can be implemented into the Croatian laboratories and clinical practice.


Subject(s)
Biomarkers/blood , Blood Chemical Analysis/standards , Pediatrics/standards , Adolescent , Child , Child, Preschool , Croatia , Diagnostic Tests, Routine , Female , Humans , Immunoassay/standards , Infant , Luminescence , Luminescent Measurements/standards , Male , Outpatients , Reference Values , Reproducibility of Results , Sex Factors
15.
Biochem Med (Zagreb) ; 30(2): 020702, 2020 Jun 15.
Article in English | MEDLINE | ID: mdl-32292280

ABSTRACT

INTRODUCTION: Autovalidation (AV) is an algorithm based on predefined rules designed, among others, to automate and standardize the postanalytical phase of laboratory work. The aim of this study was to examine the overall opinion of Croatian medical biochemistry laboratories regarding various aspects of AV. MATERIAL AND METHODS: This retrospective study is an analysis of the responses of a survey about AV comprised of 18 questions, as part of Module 10 ("Postanalytical phase of laboratory testing") of national External Quality Assessment program, administered by the Croatian Centre for Quality Assessment in Laboratory Medicine. Results were reported as percentages of total number of participants in survey or as proportions of observed data if the overall number of data was <100. RESULTS: 121 laboratories responded to the survey, of which 76% do not use AV, while 11% of laboratories use AV in routine laboratory work. 16/29 laboratories implemented semi-automated AV for general biochemistry (7/29), haematology (5/29), and coagulation (4/29) tests. Analytical measurement ranges, critical values, flags from analysers, interference indices and delta check were the most commonly used rules in the algorithm. 12/29 laboratories performed validation of AV with less than 500 samples (8/29). 7/13 laboratories report the percentage of AV being 20-50%, while 10/13 answered that introduction of AV significantly reduced turnaround time (TAT) (for 20 - 25%), especially for biochemistry tests. CONCLUSIONS: Despite of its numerous benefits (i.e. shorter TAT, less manual validation, standardization of the postanalytical phase), only a small number of Croatian laboratories use AV.


Subject(s)
Automation , Blood Chemical Analysis/standards , Laboratories, Hospital/standards , Medical Laboratory Science/standards , Algorithms , Humans , Reproducibility of Results , Retrospective Studies , Surveys and Questionnaires
17.
Croat Med J ; 61(1): 18-27, 2020 Feb 29.
Article in English | MEDLINE | ID: mdl-32118374

ABSTRACT

AIM: To assess the role of human platelet antigens (HPA), P-selectin gene (SELP) polymorphisms, and HPA and SELP haplotypes with factor V (FV) R506Q in ischemic pediatric stroke (IPS) subtypes: cerebral sinovenous thrombosis (CSVT), perinatal (PAIS), and childhood (CAIS) arterial ischemic stroke. METHODS: This case-control study enrolled 150 children with confirmed IPS and 150 age- and sex-matched controls. FV R506Q and HPA-1 were genotyped with CVD StripAssay®, HPA-2 and HPA-3 with real-time polymerase chain reaction, SELP S290N, V599L, and T715P with high resolution melting analysis, and SELP N562D with sequence-specific polymerase chain reaction. RESULTS: HPA-1b allele (odds ratio [OR] 2.75, 95% confidence interval [CI] 1.02-7.42, P=0.048) and HPA-1a2a3b (OR 5.46, 95% CI 1.51-19.76, P=0.011), HPA-1b2a3a (OR 7.00, 95% CI 1.25-39.13, P=0.028), and HPA-1b2b3a (OR 11.39, 95% CI 1.39-92.95, P=0.024) haplotypes increased the risk for CSVT. HPA-3b allele was significantly associated with 2-fold lower risk for PAIS (OR 0.49, 95% CI 0.26-0.89, P=0.020) and CAIS (OR 0.47, 95% CI 0.26-0.86, P=0.014) and non-significantly associated with increased risk for CSVT (OR 6.43, 95% CI 0.83-50.00, P=0.022). HPA-1a2b3a haplotype was significantly associated with CAIS (OR 6.76, 95% CI 2.13-21.44, P=0.001). The inclusion of FV R506Q in SELP haplotype analysis increased the risk for PAIS 4-fold in QNDVT carriers (OR 8.14, 95% CI 0.93-71.33, P=0.060) compared with NDVT haplotype (OR 2.45, 95% CI 0.98-6.18, P=0.058), but the result was not significant. CONCLUSION: Individual HPAs, and particularly HPA haplotypes, are involved in IPS subtypes pathogenesis. A possible risk-inducing synergistic effect of SELP haplotypes with FV R506Q is restricted to PAIS only.


Subject(s)
Antigens, Human Platelet/genetics , Brain Ischemia/genetics , Polymorphism, Single Nucleotide , Stroke/genetics , Adolescent , Alleles , Brain Ischemia/diagnosis , Case-Control Studies , Child , Child, Preschool , Factor V/genetics , Female , Genotype , Haplotypes , Heterozygote , Humans , Infant , Infant, Newborn , Male , Odds Ratio , P-Selectin/genetics , Real-Time Polymerase Chain Reaction , Stroke/diagnosis
18.
Biochem Med (Zagreb) ; 29(2): 020502, 2019 Jun 15.
Article in English | MEDLINE | ID: mdl-31223256

ABSTRACT

The post-analytical phase is the final phase of the total testing process and involves evaluation of laboratory test results; release of test results in a timely manner to appropriate individuals, particularly critical results; and modification, annotation or revocation of results as necessary to support clinical decision-making. Here we present a series of recommendations for post-analytical best practices, tailored to medical biochemistry laboratories in Croatia, which are intended to ensure alignment with national and international norms and guidelines. Implementation of the national recommendations is illustrated through several examples.


Subject(s)
Biomedical Research/standards , Clinical Medicine/standards , Medical Laboratory Science/standards , Humans
19.
Biochem Med (Zagreb) ; 29(2): 020709, 2019 Jun 15.
Article in English | MEDLINE | ID: mdl-31223263

ABSTRACT

INTRODUCTION: In line with the national recommendations, Croatian medical laboratories report urine test strip qualitative analysis results using a categorized scale with defined number of categories. Since concentration ranges for measured analytes have not been provided by national professional authority, it is up to the laboratories to define their own categories. The aim of study was to assess the comparability of concentrations assigned to different categories used in reporting the results of dipstick urinalysis in Croatian laboratories. MATERIAL AND METHODS: A questionnaire was e-mailed to all Croatian medical laboratories (N = 195). They were asked to provide the number of categories and respective concentrations for each parameter. Data were described as numbers and percentages. Values above the upper reference range limit, which were assigned as normal and/or trace category, were considered as false negative. RESULTS: Response rate was 71% (139/195). Seventy percent (98/139) of laboratories report their results with either higher (77/98; 79%) or lower (2/98; 2%) number of categories, relative to the national recommendation, whereas 19/98 (19%) report their results as concentrations. Great heterogeneity of reporting categories was observed. Multiple categories were assigned to same concentrations and there was a large overlap of concentrations for most categories. Considerable proportion of laboratories reported false negative results for ketones (42%), leukocytes (30%) and glucose (21%). CONCLUSIONS: The concentrations assigned to categories used to report the results of dipstick urinalysis are not comparable among Croatian medical laboratories. There is an urgent need for harmonization and standardization of reporting the results of urine dipstick analysis in Croatia.


Subject(s)
Clinical Laboratory Techniques , Reagent Strips/analysis , Surveys and Questionnaires , Urinalysis , Humans
20.
Biochem Med (Zagreb) ; 29(1): 010708, 2019 Feb 15.
Article in English | MEDLINE | ID: mdl-30799977

ABSTRACT

INTRODUCTION: Variability among manufacturers of urine dipsticks, respective to their accuracy and measurement range, may lead to diagnostic errors and thus create a serious risk for the patient. Our aims were to determine the level of agreement between 12 most commonly used urine dipsticks in Croatia, examine their accuracy for glucose and total protein and to test their repeatability. MATERIALS AND METHODS: A total of 75 urine samples were used to examine comparability and accuracy of 12 dipstick brands (Combur 10 TestM, ChoiceLine 10, Combur 10 TestUX, ComboStik 10M, ComboStik 11M, CombiScreen 11SYS, CombiScreen 10SL, Combina 13, Combina 11S, Combina 10M, UriGnost 11, Multistix 10SG). Agreement between each dipstick and the reference (Combur 10 TestM) was expressed as kappa coefficient (acceptable κ ≥ 0.80). Accuracy for glucose and total protein was tested by comparison with quantitative measurements on analysers: AU400 (Beckman Coulter, USA), Cobas 6000 c501 (Roche Diagnostics, Germany) and Architect plus c4000 (Abbott, USA). Repeatability was assessed on 20 replicates (acceptable > 90%). RESULTS: Best agreement was achieved for glucose, total protein and nitrite (11/11, k > 0.80) and the lowest for bilirubin (5/5, k < 0.60). Sensitivities for total protein were 41-75% (AU400) and 56-92% (Cobas and Architect); while specificities were 41-75% (AU400, Cobas, Architect). Dipsticks' sensitivity and specificity for glucose were 68-98%. Most of the dipsticks showed unacceptable repeatability (6/12, < 90%) for one parameter, most prominently for pH (3/12, < 90%). CONCLUSIONS: Most commonly used dipsticks in Croatia showed low level of agreement between each other. Moreover, their repeatability varies among manufacturers and their accuracy for glucose and proteins is poor.


Subject(s)
Bilirubin/urine , Glucose/analysis , Nitrites/urine , Proteins/analysis , Urinalysis/instrumentation , Urinalysis/standards , Croatia , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...