Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 56
Filter
1.
Radiologie (Heidelb) ; 2024 May 07.
Article in German | MEDLINE | ID: mdl-38713222

ABSTRACT

BACKGROUND: Globally, stroke is considered the second most common cause of death. According to the German Federal Statistical Office, 33.6% of mortality was due to cardiovascular diseases, making them the most prevalent cause of death. PROBLEM: Specifically, cerebral infarctions were recorded as the cause in over 16,000 cases. These figures underscore the significant role that cerebrovascular diseases play in Germany's mortality statistics. Notably, about 80% of strokes are ischemic. Moreover, one-fifth of all strokes result from extracranial carotid stenosis. The increase in stroke risk with advancing age, especially among men, is particularly striking. This trend highlights the growing importance of efficient stroke prevention and treatment in an aging society. CONCLUSION: Open surgical therapy, as a crucial treatment method, is increasingly important, especially as an emergency intervention. Its role in modern medicine emphasizes the urgency of prioritizing this life-saving procedure in healthcare and making it widely available.

4.
CVIR Endovasc ; 7(1): 23, 2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38416319

ABSTRACT

BACKGROUND: The Viabahn stent graft has emerged as an integral tool for managing vascular diseases, but there is limited long-term data on its performance in emergency endovascular treatment. This study aimed to assess safety, technical success, and long-term efficacy of the Viabahn stent graft in emergency treatment of arterial injury. METHODS: We conducted a retrospective single tertiary centre analysis of patients who underwent Viabahn emergency arterial injury treatment between 2015 and 2020. Indication, intraoperative complications, technical and clinical success, and major adverse events at 30 days were evaluated. Secondary efficacy endpoints were the primary and secondary patency rates assessed by Kaplan-Meier analysis. RESULTS: Forty patients (71 ± 13 years, 19 women) were analyzed. Indications for Viabahn emergency treatment were extravasation (65.0%), arterio-venous fistula (22.5%), pseudoaneurysm (10.0%), and arterio-ureteral fistula (2.5%). No intraoperative adverse events occurred, technical and clinical success rates were 100%. One acute stent graft occlusion occurred in the popliteal artery on day 9, resulting in a 30-day device-related major-adverse-event rate of 2.5%. Median follow-up was 402 days [IQR, 43-1093]. Primary patency rate was 97% (95% CI: 94-100) in year 1, and 92% (95% CI: 86-98) from years 2 to 6. One stent graft occlusion occurred in the external iliac artery at 18 months; successful revascularization resulted in secondary patency rates of 97% (95% CI: 94-100) from years 1 to 6. CONCLUSION: Using Viabahn stent graft in emergency arterial injury treatment had 100% technical and clinical success rates, a low 30-day major-adverse-event rate of 2.5%, and excellent long-term patency rates.

5.
Front Cardiovasc Med ; 10: 1279830, 2023.
Article in English | MEDLINE | ID: mdl-38054092

ABSTRACT

Introduction: To assess the outcomes after thoracic endovascular aneurysm repair (TEVAR) in the presence of intramural hematoma (IMH) in the proximal sealing zone. Material and methods: Patient data were retrospectively extracted from the hospital records of patients treated with TEVAR for acute and chronic aortic dissection type B in one single center. The initial, preoperative, first postoperative, and last follow-up CT scans were evaluated in the aortic 3D multiplanar reformats and the centerline regarding IMH presence in the proximal sealing zone, anatomical preconditions, and the morphological TEVAR complications including migration and bird-beak. Groups with (IMH) and without IMH (no-IMH) were compared. Results: Overall, 84 patients (IMH:42; no-IMH:42) were treated at the age of 63(55; 72) years, of whom 23/84 (27%), 34/84 (40%), and 27/84 (32%) were in the hyperacute, acute and subacute dissection phases, respectively. The bovine arch was found in 10/84(12%) and the type III arch was most common (43/84;51%). IMH maximum extent was found in zones 0, 1, 2, and 3 in 14/84 (17%), 17/84 (20%), 18/84 (21%), and 6/84 (7%), respectively. Sealing was achieved in zone II in 71/84 (85%) and LSA was revascularized in 66/84 (79%) of the overall cohort. Early mortality and paraplegia were 2/84 (2%) each; stroke rate was 3/84 (4%). During the 22 months median follow-up (22;4;43) no RTAD was observed. Migration ≥10 mm (IMH: 11/82; no-IMH: 10/82; P = 1.0) and bird-beaks (IMH: 10/82; no-IMH: 12/82; P = 0.8036) were comparable in both groups and accompanied by a low aorta related mortality (1/82) in both groups. Conclusion: The presence of the IMH in the proximal TEVAR sealing zone is frequent and may not be relevant for the occurrence of the RTAD, stent-graft migration, or bird-beak formation.

6.
J Clin Med ; 12(19)2023 Oct 07.
Article in English | MEDLINE | ID: mdl-37835039

ABSTRACT

The aim was to assess the mid-term results of the E-iliac branched device. Baseline and follow-up data of this monocentric retrospective cohort study including all consecutive patients with aortoiliac aneurysms treated with iliac branched devices between 2016 and 2023 were extracted from the hospital records. Preoperative and follow-up CT scans were analyzed regarding endoleaks, migration, aneurysm sac remodeling, and device patency. Overall, 50 devices were implanted in 38 patients with a median age of 69 (IQR 62-78) years, and 1.6 bridging stent grafts per vessel were implanted through transfemoral (22/50; 44%) or upper extremity access (28/50; 56%). Primary technical success and assisted technical success were 97% (37/38) and 100% (38/38), respectively. No migration, no type I or III endoleaks, no stroke, colonic ischemia, aneurysm rupture, or conversion during the early and mid-term follow-ups (11 months, IQR 5-26) were observed. Aneurysm sac enlargement or shrinkage was observed in 0% (0/38) and 16% (6/38) patients, respectively. E-iliac-related re-interventions were seen only during the early follow-up: two thrombectomies with bare-metal stent relining after thrombosis of the iliac limb. Bridging stent graft and E-iliac patency during the mid-term follow-up were 100%. E-iliac showed encouraging mid-term results in the treatment of aortoiliac aneurysms with high technical success and a low re-intervention rate.

9.
J Endovasc Ther ; : 15266028231170114, 2023 May 02.
Article in English | MEDLINE | ID: mdl-37128868

ABSTRACT

PURPOSE: The aim was to assess the mid-term aortic remodeling and bare-metal stent (BMS) integrity of the restricted bare stent (RBS) technique reconstruction in aortic dissections. MATERIALS AND METHODS: This retrospective cohort study included prospectively collected patients treated with the modified RBS technique between 2017 and 2020. The preoperative, postoperative, and last follow-up computed tomographic (CT) scans were analyzed in the centerline at the mid-descending, celiac trunk (CeT), and the mid-abdominal levels for false lumen (FL) patency, aortic diameter, and true lumen (TL) diameter changes. Bare-metal stent integrity was assessed in the 3-dimensional multiplanar reformats. RESULTS: The median follow-up of the cohort (n=17) was 26 (11, 45) months. The procedure was mainly performed with the Relay NBS endograft (15/17; 88%) + E-XL BMS (17/17; 100%). Postoperative mortality, paraplegia, stroke, renovisceral vessel loss, and type I and III endoleaks were not observed. BMS fractured in 6 patients (6/17; 36%), damaged the dissection flap in 4/17 (24%), and led to the reperfusion of the FL and re-interventions with TEVAR (4/17; 24%). Two patients without FL reperfusion showed stable CT follow-ups 13 and 17 months after the fracture diagnosis. The TL expansion was seen at all landmarks and peaked in the thoracic aorta (+10; 6, 15; p<0.001). The FL thrombosis after modified RBS was only relevant in the thoracic aorta (p<0.001) and at CeT (p=0.003). The aortic diameter was stable in the thoracic aorta and increased at distal landmarks (CeT [+5; 1, 10; p=0.001]; mid-abdominal [+3; 1, 5; p=0.004]). CONCLUSION: The modified RBS technique could not stop aortic growth below the diaphragm and prevent new membrane rupture due to the fractures of the BMS and consecutive flap damage with the reperfusion of the FL. CLINICAL IMPACT: The treatment of complicated type B aortic dissections with TEVAR has become a standard. Particularly, patients with true lumen collapse and malperfusion may benefit from a more aggressive treatment strategy including proximal TEVAR and distal bare-metal stent implantation to re-open the true lumen and to prevent distal stent-induced new entry. However, this study reports the challenges of this approach with a high rate of bare-metal stent fractures during the follow-up. The fractures that occurred at the site of vertical nitinol bridges led to the dissection membrane ruptures and the reperfusion of the false lumen with consecutive dilatation. A close follow-up is mandatory to detect this complication and to treat the patients with TEVAR extension.

10.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Article in English | MEDLINE | ID: mdl-37104742

ABSTRACT

OBJECTIVES: Age-related atherosclerosis has been shown to cause aortic stiffness and wall rigidification. This analysis aimed to correlate age and dissection extension length in a large contemporary multicentre study. We hypothesize that younger patients suffer more extensive DeBakey type I dissection due to aortic wall integrity, allowing unhindered extension within the layers. METHODS: The perioperative data of 3385 patients from the German Registry for Acute Aortic Dissection Type A were retrospectively analyzed with regard to postoperative outcomes and dissection extension. Patients with DeBakey type I aortic dissection (n = 2510) were retrospectively identified and divided into 2 age groups for comparison: ≤69 years (n = 1741) and ≥70 years (n = 769). Patients with DeBakey type II dissection or connective tissue disease were excluded from the analysis. RESULTS: In younger patients (≤69 years), aortic dissection involved the supra-aortic vessels significantly more often (52.0% vs 40.1%; P < 0.001) and extended significantly further downstream the aorta: descending aorta (68.4% vs 57.1%; P < 0.001), abdominal aorta (54.6% vs 42.1%; P < 0.001) and iliac bifurcation (36.6% vs 26.0%; P < 0.001). Consequently, younger patients also presented with significantly higher incidences of preoperative cerebral (P < 0.001), spinal (P < 0.001), visceral (P < 0.001), renal (P = 0.013) and peripheral (P < 0.001) malperfusion. In older patients (≥70 years), dissection extent was significantly more often limited to the level of the aortic arch (40.9% vs 29.2%; P < 0.001). No significant difference was found with regard to 30-day mortality (20.7% vs 23.6%; P = 0.114). CONCLUSIONS: Extensive DeBakey type I aortic dissection is less frequent in older patients ≥70 years than in younger patients. In contrast, younger patients suffer more often from preoperative organ malperfusion and associated complications. Postoperative mortality remains high irrespective of age groups.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Humans , Aged , Retrospective Studies , Blood Vessel Prosthesis Implantation/adverse effects , Stents , Treatment Outcome , Aorta, Abdominal , Aortic Aneurysm, Thoracic/surgery , Acute Disease , Postoperative Complications
11.
Rofo ; 195(5): 406-415, 2023 05.
Article in English | MEDLINE | ID: mdl-36261069

ABSTRACT

PURPOSE: To evaluate the safety and efficacy of rotational thrombectomy (RT) in a large single-center real-world cohort for total vascular occlusions of the lower extremity. MATERIALS AND METHODS: The clinical records and images of all patients between 2010 and 2020 treated via RT (Rotarex, BD) were assessed. Patient demographics, clinical data, procedural characteristics, and outcome parameters were documented. In total, 397 procedures in 293 patients were included (mean age 69.8 ±â€Š12.0 years; 64.8 % male). Occlusions were acute (47.5 %), subacute and acute-on-chronic (22.2 %), and chronic (30.3 %). The target lesions were the iliac artery (7.1 %), iliac/femoropopliteal (5.0 %), femoropopliteal (59.4 %), femoropopliteal/below-the-knee (27.0 %), below-the-knee (1.5 %), and after bypass surgery (14.9 %). Lesion length was > 20 cm in 61.5 % of cases. RESULTS: Clinically successful revascularization was achieved in 90.4 % of cases. Additional thrombolysis was necessary for 32.0 % of procedures. The arithmetic mean ankle-brachial index increased from 0.33 ±â€Š0.29 to 0.81 ±â€Š0.25 (p < 0.0001). Bypass grafts were less likely to be fully treatable and required additional lysis (p < 0.001). The overall primary patency (no clinically driven target lesion revascularization) was 93.2 %, 88.8 %, 79.1 %, and 72.4 % at 1, 3, 6, and 12 months, respectively. Adverse events occurred in 46.1 % of cases, of which peripheral embolization (22.4 %) was most frequent, requiring interventional treatment in 67.4 % of cases. RT was directly associated with 7.1 % (n = 28) of complications, which consisted of perforations 2.8 %, arteriovenous fistula 1.3 %, and dissections 2.0 %. CONCLUSION: Rotational thrombectomy is a safe and efficient method for the treatment of occlusions of the arterial circulation of the lower extremity with bypass occlusions having a higher propensity for residual thrombi requiring further lysis therapy. KEY POINTS: · Rotational thrombectomy was safe and efficacious for treating occlusions of the lower extremities.. · Rotational thrombectomy was associated with 7.1 % of complications.. · Distal embolization occurred in 22.4 % of cases with 67.4 % requiring interventional treatment.. · Primary patency was 93.2 %, 88.8 %, 79.1 %, 72.4 % after 1, 3, 6, and 12 months, respectively.. CITATION FORMAT: · Artzner C, Martin I, Hefferman G et al. Safety and Efficacy of Rotational Thrombectomy for Treatment of Arterial Occlusions of the Lower Extremities: A Large Single-Center Retrospective Study. Fortschr Röntgenstr 2023; 195: 406 - 415.


Subject(s)
Arterial Occlusive Diseases , Popliteal Artery , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Female , Retrospective Studies , Popliteal Artery/surgery , Thrombectomy/methods , Femoral Artery/surgery , Arterial Occlusive Diseases/therapy , Arterial Occlusive Diseases/surgery , Lower Extremity , Treatment Outcome , Vascular Patency
12.
J Endovasc Ther ; 30(2): 185-193, 2023 04.
Article in English | MEDLINE | ID: mdl-35209760

ABSTRACT

PURPOSE: The objective of this study was to compare the outcomes of patients treated with tube grafts and AFX stent-graft in the narrow infrarenal aortic anatomy. MATERIALS AND METHODS: Patients with penetrating aortic ulcers (PAUs) or sacciform aneurysms of the infrarenal aorta and an aortic bifurcation diameter ≤20 mm who underwent endovascular aneurysm repair (EVAR) with bifurcated AFX or tube stent-grafts (TUBE) between 2012 and 2020 were included. Demographic data and the outcome of the AFX group were compared with the TUBE group. All morphological measurements in the preoperative and postoperative computed tomography scans were performed in the aortic centerline. RESULTS: Fifty-one patients (female: 12/51; 29%; median age: 72 years [63, 77]) with a median follow-up of 10 (3, 39) months, were included, of whom 35/51 (69%) had PAUs and 11/51 were symptomatic (22%). The aortic bifurcation diameter was 17 mm (15, 18) with severe calcifications in 25/51 (49%). The distal aortic landing zone was longer in the TUBE group (9 mm vs 24 mm; p<0.001). The technical success was 96% with a median aneurysm shrinkage of 8% (3, 13), which was comparable between the groups (p=0.264). Periprocedural mortality, conversion to open surgery, myocardial infarction, and stroke were not observed. Two type Ia endoleaks (EL) and 2 type Ib EL occurred, all in the TUBE group (Type 1 EL; 19 vs 0%; p=0.013). The limb patency in the AFX group was 100%. One patient with a tube graft developed an infrarenal aortic thrombosis 40 months after the intervention. The reintervention rate in the TUBE group was higher (14 vs 0%; p=0.032) and included 3 aortic cuff implantations and 1 covered endovascular aortic reconstruction of aortic bifurcation (CERAB). CONCLUSION: AFX stent-graft showed a lower rate of type I endoleaks and reinterventions in sacciform infrarenal aortic pathologies during the early and midterm follow-up.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Female , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Endovascular Aneurysm Repair , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Stents/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Treatment Outcome , Endovascular Procedures/adverse effects , Retrospective Studies , Blood Vessel Prosthesis , Aorta, Abdominal/surgery , Prosthesis Design
13.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Article in English | MEDLINE | ID: mdl-36477549

ABSTRACT

OBJECTIVES: The aim of this study was to assess the endograft position and aortic geometry changes after thoracic endovascular aortic repair (TEVAR) and frozen elephant trunk (FET) in distal stent-induced new entry (dSINE) patients. METHODS: In this retrospective cohort study, the baseline demographic and the follow-up data were extracted from the hospital records, and computed tomography scans of dSINE patients after TEVAR or FET between 2011 and 2021 were analysed regarding endograft oversizing, length and migration, taper ratio, aortic diameter at the endograft end, aortic elongation (thoracic inner and outer curvature), wedge apposition angle and tortuosity angle in the distal landing zone. RESULTS: dSINE was found in 22/213 (10%) of TEVAR and 10/31 (32%) of FET patients. The total follow-up time was 45 (27; 59) months. TEVAR was mainly performed with Relay NBS endograft (77%) and FET with Evita open prosthesis (80%). Paraplegia and stroke rates were 3%. dSINE occurred 17 (7; 35) months post-TEVAR and was instantly treated in 18 patients (56%) or followed up for 21 (11; 34) months (n = 14). Migration [+5 mm (1; 11; P < 0.001)], birdbeak angle [+9° (0; 27; P = 0.039)] and aortic diameter +5 mm (1; 11; P < 0.001) increased after dSINE, whereas aortic elongation increased already before [+12 mm (0; 27; P = 0.015)] and peaked after dSINE [+30 mm (9; 38; P < 0.001)]. The aortic elongation was more pronounced in the outer aortic curvature before and after dSINE (before: P = 0.039, after: P = 0.024). Postoperative wedge apposition [17° (12; 20)] increased before dSINE [21° (16; 35; P < 0.001)] and peaked thereafter [31° (21; 40; P < 0.001)]. CONCLUSIONS: Aortic elongation may influence the endograft position and provoke TEVAR failure in the distal and proximal landing zones.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Treatment Outcome , Endovascular Procedures/adverse effects , Stents/adverse effects , Aortic Dissection/surgery , Aorta/surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Prosthesis Design
14.
Medicina (Kaunas) ; 58(10)2022 Oct 09.
Article in English | MEDLINE | ID: mdl-36295575

ABSTRACT

Background and Objectives: The strategy of revascularization may be constrained in patients with insufficient bypass grafts and with increased risk of wound healing disorders. Among those with complex left-sided double-vessel disease in whom a percutaneous coronary intervention (PCI), as well as the surgical procedure of minimally invasive coronary artery bypass grafting via left minithoracotomy (MICS CABG), is not a treatment option, CABG using the left internal mammary artery as a T-graft with itself may be an effective treatment strategy. Materials and Methods: We reviewed the data from patients treated in Cologne and Tuebingen from 2019 to 2022. We included 40 patients who received left internal mammary artery (LIMA) grafting, and additional T-graft with the LIMA itself. The objective was focused on intraoperative and short-term outcomes. Results: A total of 40 patients were treated with the LIMA-LIMA T-graft procedure with a Fowler score calculated at 20.1 ± 3.0. A total of 37.5% of all patients had lacking venous graft material due to prior vein stripping, and 21 patients presented severe vein varicosis. An overall of 2.6 ± 0.5 distal anastomoses (target vessels were left anterior descending, diagonal, intermediate branch, and/or left marginal ramus) were performed, partly sequentially. Mean flow of LIMA-Left anterior descending (LAD) anastomosis was 59.31 ± 11.04 mL/min with a mean PI of 1.21 ± 0.18. Mean flow of subsequent T-Graft accounted for 51.31 ± 3.81 mL/min with a mean PI of 1.39 ± 0.47. Median hospital stay was 6.2 (5.0; 7.5) days. No incidence of postoperative wound healing disorders was observed, and all patients were discharged. There was one 30-day readmission with a diagnosis of pericardial effusion (2.5%). There was no 30-day mortality within the cohort. Conclusions: Patients requiring surgical myocardial revascularization due to complex two-vessel coronary artery disease (CAD) can be easily managed with LIMA alone, despite an elevated Fowler score and a promising outcome. A prospective study needs to be conducted, as well as longer term surveillance, to substantiate and benchmark the long-term results, as well as the patency rates.


Subject(s)
Coronary Artery Disease , Mammary Arteries , Percutaneous Coronary Intervention , Humans , Mammary Arteries/transplantation , Coronary Artery Disease/surgery , Retrospective Studies , Coronary Artery Bypass/methods , Treatment Outcome
15.
Zentralbl Chir ; 147(5): 447-452, 2022 Oct.
Article in German | MEDLINE | ID: mdl-36220065

ABSTRACT

Complex endovascular therapy of the aorta with fenestrated and branched endografts plays an essential role in modern vascular medicine. Innovative solutions for demanding aortic pathologies are therefore being constantly developed by the medical industry. The aim of this manuscript is to illustrate the growing importance of the inner branches in complex aortic repair and to show the advantages and limits of this technique with an overview of the current literature. The inner branches (iBEVAR) were therefore compared to the standard treatment options (fenestrations; [FEVAR], outer branches [BEVAR]) and the technical advantages of all platforms were evaluated. The widespread use of iBEVAR in the aortic arch stands in contrast to the thoracoabdominal aorta, which is mirrored by the scarce evidence for the thoracoabdominal inner branches. The published experience is based on smaller retrospective studies with a 1-year follow-up. The E-nside (Artivion, Hechingen, Germany) thoracoabdominal off-the-shelf inner-branch-based endograft was released 2 years ago. Its widespread deployment may increase the use of the inner branches in the thoracoabdominal aorta. Moreover, an ongoing industry-funded registry may provide new insights into the long-term durability of this innovative technique.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Humans , Postoperative Complications , Prosthesis Design , Retrospective Studies , Stents , Treatment Outcome
18.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Article in English | MEDLINE | ID: mdl-35257145

ABSTRACT

Branched endovascular aneurysm repair (BEVAR) is increasingly being performed with the off-the-shelf devices. We evaluated the use of the wire-assisted sheath stabilization technique for the new inner branch-based (iBEVAR), off-the-shelf E-nside endograft in 2 patients. The cannulation of the 8 reno-visceral target vessels and the BSG implantation were successfully performed using the total transfemoral approach. Complications were not observed during the 3-month follow-up. The wire-assisted sheath stabilization technique was shown feasible in an off-the-shelf iBEVAR.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Humans , Prosthesis Design , Retrospective Studies , Stents , Treatment Outcome
20.
Eur J Cardiothorac Surg ; 61(4): 869-876, 2022 03 24.
Article in English | MEDLINE | ID: mdl-34747437

ABSTRACT

OBJECTIVES: The aim of this study was to assess preoperative dissection flap motility and to evaluate its impact on the aortic remodelling and the development of distal stent-induced new entry after thoracic endovascular aneurysm repair (TEVAR)/frozen elephant trunk (FET). METHODS: Patients with primary or residual type B dissections were included in a retrospective study with transoesophageal echocardiography analysis of the preoperative dissection flap motility assessed by the true lumen (TL) strain. Three-dimensional computing tomography centreline reconstructions before TEVAR/FET and during the follow-up were conducted to measure aortic remodelling: false lumen thrombosis, TL expansion and aortic diameters at 10 and 20 cm downstream the left subclavian artery, at the coeliac trunk and in the infrarenal aorta. All continuous variables are reported as median with first and third quartiles. RESULTS: Fifty-six consecutive patients were treated with TEVAR (n = 45) or FET (n = 11) in the acute (n = 16), subacute (n = 16) and chronic (n = 24) dissection phase. At a median follow-up of 6 (3-12) months, they showed a favourable TL expansion in the descending aorta, significantly higher in the acute [+9 mm (5-12); P < 0.001] and subacute groups [+5 mm (3-8); P = 0.039] than in the chronic group [+2 mm (0-5)]. The dissection flap motility parameter TL strain was superior in the acute (P = 0.006) and subacute (P = 0.035) groups in comparison to the chronic group. The motile flap [TL strain >22.5% (median)] was associated with a higher TL expansion rate in the thoracic aorta (P = 0.009) and a comparable distal stent-induced new entry incidence (overall: 16%) in comparison to the immobile flap (P = 0.89). CONCLUSIONS: The intraoperative assessment and the inclusion of the dissection flap motility parameters in the decision-making during TEVAR/FET may refine the distal endograft sizing for an improved remodelling of the TL.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Dissection/etiology , Aortic Dissection/surgery , Aorta/surgery , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Thoracic/etiology , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Humans , Retrospective Studies , Stents/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...