1.
J Clin Med ; 13(5)2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38592136

ABSTRACT

Background: Atrial fibrillation (AF) catheter ablation in cancer patients has been evaluated in very few studies. We aimed to investigate utilization trends and in-hospital outcomes of AF catheter ablation among cancer patients in a large US inpatient registry. Methods: Utilizing the National Inpatient Sample (NIS) database, patients who underwent AF catheter ablation between 2012 and 2019 were identified. Sociodemographic, clinical data, in-hospital procedures and outcomes were collected. Baseline characteristics and in-hospital outcomes were compared between patients with and without cancer. Results: An estimated total of 67,915 patients underwent AF catheter ablation between 2012 and 2019 in the US. Of them, 950 (1.4%) had a cancer diagnosis. Patients with a cancer diagnosis were older and had higher Charlson Comorbidity Index, CHA2DS2-VASc and ATRIA bleeding indices scores. A higher rate of total complications was observed in cancer patients (10.5% vs. 7.9, p < 0.001), driven mainly by more bleeding and infectious complications. However, no significant differences in cardiac or neurological complications as well as in-hospital mortality rates were observed and were relatively low in both groups. Conclusions: AF catheter ablation in cancer patients is associated with higher bleeding and infectious complication rates, but not with increased cardiac complications or in-hospital mortality in a US nationwide, all-comer registry.

3.
J Am Heart Assoc ; 12(15): e029126, 2023 08.
Article in English | MEDLINE | ID: mdl-37522389

ABSTRACT

Background Routine addition of an atrial lead during an implantable cardioverter-defibrillator (ICD) implantation for primary prevention of sudden cardiac death, in patients without pacing indications, was not shown beneficial in contemporary studies. We aimed to investigate the use and safety of single- versus dual-chamber ICD implantations in these patients. Methods and Results Using the National Inpatient Sample database, we identified patients with no pacing indications who underwent primary-prevention ICD implantation in the United States between 2015 and 2019. Sociodemographic and clinical characteristics, as well as in-hospital complications, were analyzed. Multivariable logistic regression was used to identify predictors of in-hospital complications. An estimated total of 15 940 patients, underwent ICD implantation for primary prevention of sudden cardiac death during the study period, 8860 (55.6%) received a dual-chamber ICD. The mean age was 64 years, and 66% were men. In-hospital complication rates in the dual-chamber ICD and single-chamber ICD group were 12.8% and 10.7%, respectively (P<0.001), driven by increased rates of pneumothorax/hemothorax (4.6% versus 3.4%; P<0.001) and lead dislodgement (3.6% versus 2.3%; P<0.001) in the dual-chamber ICD group. Multivariable analyses confirmed atrial lead addition as an independent predictor for "any complications" (odds ratio [OR], 1.1 [95% CI, 1.0-1.2]), for pneumo/hemothorax (odds ratio, 1.1 [95% CI, 1.0-1.4]), and for lead dislodgement (odds ratio, 1.3 [95% CI, 1.1-1.6]). Conclusions Despite lack of evidence for clinical benefit, dual-chamber ICDs are implanted for primary prevention of sudden cardiac death in a majority of patients who do not have pacing indication. This practice is associated with increased risk of periprocedural complications. Avoidance of routine implantation of atrial leads will likely improve safety outcomes.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Male , Humans , United States/epidemiology , Middle Aged , Female , Defibrillators, Implantable/adverse effects , Atrial Fibrillation/etiology , Hemothorax/etiology , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Primary Prevention/methods , Registries
4.
J Cardiol ; 82(5): 408-413, 2023 11.
Article in English | MEDLINE | ID: mdl-37116647

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) in young adults is an uncommon and not well studied entity. METHODS: Consecutive patients aged 18-45 years admitted to internal or cardiology services in a large tertiary medical center (January 1, 2009 through December 31, 2019) were included. Clinical, electrocardiographic, and echocardiographic data were compared between patients with and without AF at baseline. Predictors of new-onset AF in the young were identified using multivariate Cox regression model among patients free of baseline AF. RESULTS: Final cohort included 16,432 patients with median age of 34 (IQR 26-41) years of whom 8914 (56 %) were men. Patients with AF at baseline (N = 366; 2 %) were older, more likely to be men, and had higher proportion of comorbidities and electrocardiographic conduction disorders. Male sex, increased age, obesity, heart failure, congenital heart disease (CHD) and the presence of left or right bundle branch block were all independently associated with baseline AF in a multivariate model (p < 0.001 for all). Sub-analysis of 10,691 (98 %) patients free of baseline AF identified 85 cases of new-onset AF during a median follow up of 3.5 (IQR 1.5-6.5) years. Multivariate model identified increased age, heart failure, and CHD as independent predictors of new-onset AF. Finally, the CHARGE-AF risk score outperformed the CHA2DS2-VASc score in AF prediction [AUC of ROC 0.75 (0.7-0.8) vs. 0.56 (0.48-0.65)]. CONCLUSIONS: AF among hospitalized young adults is not rare. Screening for new-onset AF in young post hospitalization patients may be guided by specific clinical predictors and the CHARGE-AF risk score.


Subject(s)
Atrial Fibrillation , Heart Failure , Humans , Male , Adult , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/etiology , Risk Assessment , Risk Factors , Heart Failure/complications , Comorbidity
6.
Front Cardiovasc Med ; 9: 1016657, 2022.
Article in English | MEDLINE | ID: mdl-36312249

ABSTRACT

Background: The use of cardiovascular implantable electronic device (CIED) is steadily increasing, and complications include venous occlusion and fractured leads. Transvenous lead extraction (TLE) can facilitate the re-implantation of new leads. Aims: This study aims to explore predictors and complications of non-infectious TLE. Methods: This study involves a retrospective analysis and comparison of characteristics, complications, and outcomes of patients with and without occluded veins (OVs) undergoing TLE at our center. Results: In total, eighty-eight patients underwent TLE for non-infectious reasons. Indications for TLE were lead malfunction (62; 70.5%) and need for CIED upgrade (22; 25%). Fourteen patients referred due to lead malfunction had an OV observed during venography. The OV group (36 patients) were significantly older (65.7 ± 14.1 vs. 53.8 ± 15.9, p = 0.001) and had more comorbidities. Ejection fraction (EF) was significantly lower for the OV group (27.5 vs. 57.5%, p = 0.001) and had a longer lead dwelling time (3,226 ± 2,324 vs. 2,191 ± 1,355 days, p = 0.012). Major complications were exclusive for the OV group (5.5% vs. none, p = 0.17), and most minor complications occurred in the OV group as well (33.3 vs. 4.1%, p < 0.001). Laser sheath and mechanical tools for TLE were frequently used for OV as compared to the non-occluded group (94.4 vs. 73.5%, respectively, p = 0.012). Procedure success was higher in the non-occluded group compared to the OV group (98 vs. 83.3%, respectively, p = 0.047). Despite these results, periprocedural mortality was similar between groups. Conclusion: Among the TLE for non-infectious reasons, vein occlusion appears as a major predictor of complex TLE tool use, complications, and procedural success. Venography should be considered prior to non-infectious TLE to identify high-risk patients.

7.
JACC Clin Electrophysiol ; 8(4): 498-510, 2022 04.
Article in English | MEDLINE | ID: mdl-35450605

ABSTRACT

OBJECTIVES: This study sought to examine the effect of the return electrode's surface area on bipolar RFA lesion size. BACKGROUND: Bipolar radiofrequency ablation (RFA) is typically performed between 2 3.5-mm tip catheters serving as active and return electrodes. We hypothesized that increasing the surface area of the return electrode would increase lesion dimensions by reducing the circuit impedance, thus increasing the current into a larger tissue volume enclosed between the electrodes. METHODS: In step 1, ex vivo bipolar RFA was performed between 3.5-mm and custom-made return electrodes with increasing surface areas (20, 80, 180 mm2). In step 2, ex vivo bipolar RFA was performed between 3.5-mm and 3.5-mm or 8-mm electrode catheters positioned perpendicular or parallel to the tissue. In step 3, in vivo bipolar RFA was performed between 3.5-mm and either 3.5-mm or 8-mm parallel electrode at the: 1) left ventricular summit; 2) interventricular septum; and 3) healed anterior infarction. RESULTS: In step 1, increasing the surface area of the return electrode resulted in lower circuit impedance (R = -0.65; P < 0.001), higher current (R = +0.80; P < 0.001), and larger lesion volume (R = +0.88; P < 0.001). In step 2, an 8-mm return electrode parallel to tissue produced larger and deeper lesions compared with a 3.5-mm return electrode (P = 0.014 and P = 0.02). Similarly, in step 3, compared with a 3.5-mm, bipolar RFA with an 8-mm return electrode produced larger (volume: 1,525 ± 871 mm3 vs 306 ± 310 mm3, respectively; P < 0.001) and more transmural lesions (88% vs 0%; P < 0.001). CONCLUSIONS: Bipolar RFA using an 8-mm return electrode positioned parallel to the tissue produces larger lesions in comparison with a 3.5-mm return electrode.


Subject(s)
Catheter Ablation , Catheter Ablation/methods , Electrodes , Equipment Design , Heart Ventricles/surgery , Humans
8.
J Clin Med ; 12(1)2022 Dec 27.
Article in English | MEDLINE | ID: mdl-36615015

ABSTRACT

(1) Background: Implantable cardioverter defibrillators (ICDs) have become the standard of care in the prevention of sudden cardiac death, yet studies have shown that competing causes of death may limit ICD benefits. The Norton scale is a pressure ulcer risk score shown to have prognostic value in other fields. The purpose of this study was to assess the use of the Norton scale as an aid for ICD patient selection; (2) Methods: The study was comprised of consecutive patients who underwent defibrillator implantation at Sheba Medical Center between 2008 and 2016. A competing risk analysis was performed to assess the likelihood of death prior to device therapy; (3) Results: 695 patients were included. A total of 59 (8.5%) patients had low admission Norton scale score (ANSS) (≤14), 81 (11.7%) had intermediate ANSS (15−17), and the remainder (79.8%) had high (18−20) ANSS. The cumulative probability of all-cause mortality within one year of ICD implantation in patients with low ANSS was 30%, compared with 20% and 7% among the intermediate- and high-ANSS groups, respectively. Moreover, the one-year mortality rate without ICD therapy in low-ANSS patients was over four-fold compared with that of high-ANSS patients (33% versus 7%, p < 0.0001); (4) Conclusions: The Norton scale could be a useful additional tool in predicting the life expectancy of ICD candidates, thereby improving patient selection.

9.
JACC Clin Electrophysiol ; 6(8): 973-985, 2020 08.
Article in English | MEDLINE | ID: mdl-32819533

ABSTRACT

OBJECTIVES: The goal of this study was to compare lesion durability between high-power short-duration (HP-SD) and moderate-power moderate-duration (MP-MD) ablation strategies. BACKGROUND: HP-SD radiofrequency ablation (RFA) was developed to improve pulmonary vein isolation (PVI) by reducing the effect of catheter instability inherent to MP-MD ablation strategies. However, its long-term effect on lesion durability for the treatment of atrial fibrillation is unknown. METHODS: Patients with atrial fibrillation (n = 112) underwent PVI using HP-SD ablation (45 to 50 W, 8 to 15 s) with contact force-sensing open irrigated catheter. Cavotricuspid isthmus, mitral annular, and roof lines were permitted. A control group (n = 112) underwent ablation using MP-MD ablation (20 to 40 W, 20 to 30 s) with similar technology. Chronic PV reconnection was examined in patients who required a redo procedure (HP-SD ablation, n = 18; MP-MD ablation, n = 23). RESULTS: The rate of PVI at the completion of the initial encirclement was similar between the HP-SD and MP-MD ablation strategies (90.2% vs. 83.0%; p = 0.006). The HP-SD strategy required shorter RFA time (17.2 ± 3.4 min vs. 31.1 ± 5.6 min; p < 0.001). The incidence of chronic PV reconnection was lower with HP-SD ablation (16.6% vs. 52.2%; p = 0.03). Areas of chronic reconnection were associated with catheter motion ≥1 mm for ≥50% application duration. In a higher proportion of HP-SD applications, catheter motion was <1 mm during ≥50% duration (88.6% vs. 72.8%; p < 0.001), allowing energy delivery with greater stability. Both ablation strategies were effective for cavotricuspid isthmus; however, the HP-SD strategy was less effective for mitral annular lines, requiring ablation at lower power for longer duration to avoid steam pops. CONCLUSIONS: HP-SD ablation may improve PVI durability, and it shortens RFA time. However, ablation in thicker myocardium often requires lower power applied for longer duration, allowing deeper lesions without tissue overheating.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Radiofrequency Ablation , Atrial Fibrillation/surgery , Humans , Pulmonary Veins/surgery , Treatment Outcome
10.
Circ Arrhythm Electrophysiol ; 13(6): e008625, 2020 06.
Article in English | MEDLINE | ID: mdl-32372657

ABSTRACT

BACKGROUND: The optimal method to identify the arrhythmogenic substrate of scar-related ventricular tachycardia (VT) is unknown. Sites of activation slowing during sinus rhythm (SR) often colocalize with the VT circuit. However, the utility and limitations of such approach for guiding ablation are unknown. METHODS: We conducted a multicenter study in patients with infarct-related VT. The left ventricular (LV) was mapped during activation from 3 directions: SR (or atrial pacing), right ventricular, and LV pacing at 600 ms. Ablation was applied selectively to the cumulative area of slow activation, defined as the sum of all regions with activation times of ≥40 ms per 10 mm. Hemodynamically tolerated VTs were mapped with activation or entrainment. The primary outcome was a composite of appropriate implanted cardioverter-defibrillator therapies and cardiovascular death. RESULTS: In 85 patients, the LV was mapped during activation from 2.4±0.6 directions. The direction of LV activation influenced the location and magnitude of activation slowing. The spatial overlap of activation slowing between SR and right ventricular pacing was 84.2±7.1%, between SR and LV pacing was 61.4±8.8%, and between right ventricular and LV pacing was 71.3±9.6% (P<0.05 between all comparisons). Mapping during SR identified only 66.2±8.2% of the entire area of activation slowing and 58% critical isthmus sites. Activation from other directions by right ventricular and LV stimulation unmasked an additional 33% of slowly conducting zones and 25% critical isthmus sites. The area of maximal activation slowing often corresponded to the site where the wavefront first interacted with the infarct. During a follow-up period of 3.6 years, the primary end point occurred in 14 out of 85 (16.5%) patients. CONCLUSIONS: The spatial distribution of activation slowing is dependent on the direction of LV activation with the area of maximal slowing corresponding to the site where the wavefront first interacts with the infarct. This data may have implications for VT substrate mapping strategies.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular/surgery , Action Potentials , Aged , Catheter Ablation/adverse effects , Catheter Ablation/mortality , Electrophysiologic Techniques, Cardiac , Europe , Female , Heart Rate , Humans , Male , Middle Aged , Prospective Studies , Republic of Korea , Risk Factors , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome , United States
11.
JACC Clin Electrophysiol ; 6(1): 83-93, 2020 01.
Article in English | MEDLINE | ID: mdl-31971910

ABSTRACT

OBJECTIVES: The goal of this study was to examine the safety and efficacy of radiofrequency ablation (RFA) with irrigated catheters operated in a temperature-controlled mode for ventricular ablation. BACKGROUND: Techniques to increase RFA dimensions are associated with higher risk for steam-pops. A novel irrigated catheter with circumferential thermocouples embedded in its ablation surface provides real-time surface temperature data. This study hypothesized that RFA operated in a temperature-controlled mode may allow maximizing lesion dimensions while reducing the occurrence of steam-pops. METHODS: RFA with an irrigated catheter incorporating surface thermocouples was examined in 6 swine thigh muscle preparations and 15 beating ventricles at higher (50 W/60 s, Tmax50oC) and lower (50 W/60 s, Tmax45oC) temperature limits. Biophysical properties, lesion dimensions, and steam-pop occurrence were compared versus RFA with a standard catheter operated in power-control mode at higher (50 W/60 s) and lower (40W/60 s) power, and additionally at high power with half-normal saline (50 W/60 s). RESULTS: In the thigh muscle preparation, lesion depth and width were similar between all groups (p = 0.90 and p = 0.17, respectively). Steam-pops were most frequent with power-controlled ablation at 50 W/60 s (82%) and least frequent with temperature-controlled ablation at 50 W/60 s, Tmax45oC (0%; p < 0.001). In the beating ventricle, lesion depth was comparable between all RFA settings (p = 0.09). Steam-pops were most frequent using power-controlled ablation at 50 W/60 s (37%) and least frequent with temperature-controlled ablation at 50 W/60 s, Tmax45oC (7%; p < 0.001). Half-normal saline had no incremental effect on lesion dimensions at 50 W in either the thigh muscle or the beating heart. CONCLUSIONS: RFA using a novel irrigated catheter with surface thermocouples operated in a temperature-controlled mode can maximize lesion dimensions while reducing the risk for steam-pops.


Subject(s)
Catheter Ablation , Catheters , Heart Ventricles/surgery , Therapeutic Irrigation/instrumentation , Animals , Catheter Ablation/adverse effects , Catheter Ablation/instrumentation , Catheter Ablation/methods , Catheter Ablation/standards , Equipment Design , Heart Ventricles/pathology , Swine , Temperature
12.
Circ Arrhythm Electrophysiol ; 12(10): e007879, 2019 10.
Article in English | MEDLINE | ID: mdl-31597477

ABSTRACT

BACKGROUND: In infarct-related ventricular tachycardia (VT), the circuit often corresponds to a location characterized by activation slowing during sinus rhythm (SR). However, the relationship between activation slowing during SR and vulnerability for reentry and correlation to components of the VT circuit are unknown. This study examined the relationship between activation slowing during SR and vulnerability for reentry and correlated these areas with components of the circuit. METHODS: In a porcine model of healed infarction, the spatial distribution of endocardial activation velocity was compared between SR and VT. Isthmus sites were defined using activation and entrainment mapping as areas exhibiting diastolic activity within the circuit while bystanders were defined as areas displaying diastolic activity outside the circuit. RESULTS: Of 15 swine, 9 had inducible VT (5.2±3.0 per animal) while in 6 swine VT could not be induced despite stimulation from 4 RV and LV sites at 2 drive trains with 6 extra-stimuli down to refractoriness. Infarcts with VT had a greater magnitude of activation slowing during SR. A minimal endocardial activation velocity cutoff ≤0.1 m/s differentiated inducible from noninducible infarctions (P=0.015). Regions of maximal endocardial slowing during SR corresponded to the VT isthmus (area under curve=0.84 95% CI, 0.78-0.90) while bystander sites exhibited near-normal activation during SR. VT circuits were complex with 41.7% exhibiting discontinuous propagation with intramural bridges of slow conduction and delayed quasi-simultaneous endocardial activation. Regions forming the VT isthmus borders had faster activation during SR while regions forming the inner isthmus were activated faster during VT. CONCLUSIONS: Endocardial activation slowing during SR may differentiate infarctions vulnerable for VT from those less vulnerable for VT. Sites of slow activation during SR correspond to sites forming the VT isthmus but not to bystander sites.


Subject(s)
Cicatrix/physiopathology , Endocardium/physiopathology , Heart Conduction System/physiopathology , Heart Rate/physiology , Heart Ventricles/diagnostic imaging , Myocardial Infarction/physiopathology , Tachycardia, Ventricular/etiology , Animals , Body Surface Potential Mapping/methods , Disease Models, Animal , Heart Ventricles/physiopathology , Myocardial Infarction/complications , Myocardial Infarction/diagnosis , Swine , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology
13.
JACC Clin Electrophysiol ; 5(8): 920-931, 2019 08.
Article in English | MEDLINE | ID: mdl-31439293

ABSTRACT

OBJECTIVES: This study sought to characterize the histopathological features of radiofrequency ablation (RFA) in heterogeneous ventricular scar in comparison to those in healthy myocardium. BACKGROUND: The histopathological features of RFA have been studied largely in normal myocardium. However, its effect on clinically relevant heterogeneous scar is not well understood. METHODS: Five swine with chronic infarction underwent RFA using 35-W, 45-s, 10-20 g (Biosense Webster, Irwindale, California) in heterogenous scar tissue (voltage ≤1.5 mV) and healthy myocardium (≥3.0 mV). The location of each application was marked using the electroanatomical mapping system. Histological sections at intervals of 0.5 mm with hematoxylin and eosin and Masson's trichrome stained intervals were created. A pathologist blinded to the myocardium type characterized the extent of RF injury in cellular, extracellular, and vascular structures. RESULTS: In healthy myocardium, 23 of 23 lesions (100%) were well demarcated and could be precisely measured (width: 11.3 ± 3.3 mm; depth: 7.3 ± 2.0 mm). In scar tissue, only 3 of 30 lesions (10%) were identified, and none could be measured due to a lack of defined borders. Lesions in healthy myocardium had a distinctive architecture showing a coagulative necrosis core surrounded by an outer rim of contraction band necrosis. Lesions in scar had ill-defined tissue injury without a distinct architecture. In all ablated regions, viable myocytes remained interspersed between necrotic myocytes exhibiting characteristics of both coagulative and contraction band necrosis. Connective tissue was more resistant to thermal injury in comparison to cardiomyocytes. CONCLUSIONS: RFA in scarred myocardium results in irregular tissue injury and unpredictable effect on surviving cardiomyocytes. This may be related to biophysical differences between healthy and scarred myocardium.


Subject(s)
Catheter Ablation , Cicatrix/pathology , Heart Ventricles , Animals , Heart Ventricles/pathology , Heart Ventricles/surgery , Male , Myocardial Infarction/pathology , Myocardial Infarction/surgery , Myocardium/pathology , Swine , Tachycardia, Ventricular/pathology , Tachycardia, Ventricular/surgery
15.
Heart Rhythm ; 16(10): 1468-1474, 2019 10.
Article in English | MEDLINE | ID: mdl-31284050

ABSTRACT

BACKGROUND: There is limited information on ethnic differences between patients with Brugada syndrome (BrS) and arrhythmic events (AEs). OBJECTIVE: The purpose of this study was to compare clinical, electrocardiographic (ECG), electrophysiological, and genetic characteristics between white and Asian patients with BrS and AEs. METHODS: The Survey on Arrhythmic Events in Brugada Syndrome is a multicenter survey from Western and Asian countries, gathering 678 patients with BrS and first documented AE. After excluding patients with other (n = 14 [2.1%]) or unknown (n = 30 [4.4%]) ethnicity, 364 (53.7%) whites and 270 (39.8%) Asians comprised the study group. RESULTS: There was no difference in AE age onset (41.3 ± 16.1 years in whites vs 43.3 ± 12.3 years in Asians; P = .285). Higher proportions of whites were observed in pediatric and elderly populations. Asians were predominantly men (98.1% vs 85.7% in whites; P < .001) and frequently presented with aborted cardiac arrest (71.1% vs 56%; P < .001). Asians tended to display more spontaneous type 1 BrS-ECG pattern (71.5% vs 64.3%; P = .068). A family history of sudden cardiac death was noted more in whites (29.1% vs 11.5%; P < .001), with a higher rate of SCN5A mutation carriers (40.1% vs 13.2% in Asians; P < .001), as well as more fever-related AEs (8.5% vs 2.9%; P = .011). No difference was observed between the 2 groups regarding history of syncope and ventricular arrhythmia inducibility. CONCLUSION: There are important differences between Asian and white patients with BrS. Asian patients present almost exclusively as male adults, more often with aborted cardiac arrest and spontaneous type 1 BrS-ECG. However, they have less family history of sudden cardiac death and markedly lower SCN5A mutation rates. The striking difference in SCN5A mutation rates should be tested in future studies.


Subject(s)
Arrhythmias, Cardiac/ethnology , Asian People/genetics , Brugada Syndrome/ethnology , Death, Sudden, Cardiac/ethnology , Electrocardiography/methods , White People/genetics , Adult , Age Distribution , Age of Onset , Aged , Arrhythmias, Cardiac/diagnostic imaging , Asian People/statistics & numerical data , Brugada Syndrome/diagnostic imaging , Comorbidity , Cross-Sectional Studies , Female , Humans , Incidence , Internationality , Male , Middle Aged , Prognosis , Risk Assessment , Severity of Illness Index , Sex Distribution , White People/statistics & numerical data
16.
J Am Coll Cardiol ; 73(14): 1756-1765, 2019 04 16.
Article in English | MEDLINE | ID: mdl-30975291

ABSTRACT

BACKGROUND: Information on young patients with Brugada syndrome (BrS) and arrhythmic events (AEs) is limited. OBJECTIVES: The purpose of this study was to describe their characteristics and management as well as risk factors for AE recurrence. METHODS: A total of 57 patients (age ≤20 years), all with BrS and AEs, were divided into pediatric (age ≤12 years; n = 26) and adolescents (age 13 to 20 years; n = 31). RESULTS: Patients' median age at time of first AE was 14 years, with a majority of males (74%), Caucasians (70%), and probands (79%) who presented as aborted cardiac arrest (84%). A significant proportion of patients (28%) exhibited fever-related AE. Family history of sudden cardiac death (SCD), prior syncope, spontaneous type 1 Brugada electrocardiogram (ECG), inducible ventricular fibrillation at electrophysiological study, and SCN5A mutations were present in 26%, 49%, 65%, 28%, and 58% of patients, respectively. The pediatric group differed from the adolescents, with a greater proportion of females, Caucasians, fever-related AEs, and spontaneous type-1 ECG. During follow-up, 68% of pediatric and 64% of adolescents had recurrent AE, with median time of 9.9 and 27.0 months, respectively. Approximately one-third of recurrent AEs occurred on quinidine therapy, and among the pediatric group, 60% of recurrent AEs were fever-related. Risk factors for recurrent AE included sinus node dysfunction, atrial arrhythmias, intraventricular conduction delay, or large S-wave on ECG lead I in the pediatric group and the presence of SCN5A mutation among adolescents. CONCLUSIONS: Young BrS patients with AE represent a very arrhythmogenic group. Current management after first arrhythmia episode is associated with high recurrence rate. Alternative therapies, besides defibrillator implantation, should be considered.


Subject(s)
Arrhythmias, Cardiac , Brugada Syndrome , Heart Arrest , Quinidine/therapeutic use , Risk Assessment/methods , Secondary Prevention/methods , Ablation Techniques/methods , Adolescent , Anti-Arrhythmia Agents/therapeutic use , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/genetics , Arrhythmias, Cardiac/prevention & control , Brugada Syndrome/diagnosis , Brugada Syndrome/epidemiology , Brugada Syndrome/physiopathology , Brugada Syndrome/therapy , Child , Defibrillators, Implantable/statistics & numerical data , Electrocardiography/methods , Electrophysiologic Techniques, Cardiac/methods , Female , Heart Arrest/diagnosis , Heart Arrest/prevention & control , Humans , Male , Medical History Taking/statistics & numerical data , Risk Factors , Syncope/diagnosis , Syncope/epidemiology , Syncope/etiology , Young Adult
17.
Circ Arrhythm Electrophysiol ; 12(5): e007175, 2019 05.
Article in English | MEDLINE | ID: mdl-31006313

ABSTRACT

BACKGROUND: Conduction velocity (CV) is an important property that contributes to the arrhythmogenicity of the tissue substrate. The aim of this study was to investigate the association between local CV versus late gadolinium enhancement (LGE) and myocardial wall thickness in a swine model of healed left ventricular infarction. METHODS: Six swine with healed myocardial infarction underwent cardiovascular magnetic resonance imaging and electroanatomic mapping. Two healthy controls (one treated with amiodarone and one unmedicated) underwent electroanatomic mapping with identical protocols to establish the baseline CV. CV was estimated using a triangulation technique. LGE+ regions were defined as signal intensity >2 SD than the mean of remote regions, wall thinning+ as those with wall thickness <2 SD than the mean of remote regions. LGE heterogeneity was defined as SD of LGE in the local neighborhood of 5 mm and wall thickness gradient as SD within 5 mm. Cardiovascular magnetic resonance and electroanatomic mapping data were registered, and hierarchical modeling was performed to estimate the mean difference of CV (LGE+/-, wall thinning+/-), or the change of the mean of CV per unit change (LGE heterogeneity, wall thickness gradient). RESULTS: Significantly slower CV was observed in LGE+ (0.33±0.25 versus 0.54±0.36 m/s; P<0.001) and wall thinning+ regions (0.38±0.28 versus 0.55±0.37 m/s; P<0.001). Areas with greater LGE heterogeneity ( P<0.001) and wall thickness gradient ( P<0.001) exhibited slower CV. CONCLUSIONS: Slower CV is observed in the presence of LGE, myocardial wall thinning, high LGE heterogeneity, and a high wall thickness gradient. Cardiovascular magnetic resonance may offer a valuable imaging surrogate for estimating CV, which may support noninvasive identification of the arrhythmogenic substrate.


Subject(s)
Action Potentials , Arrhythmias, Cardiac/diagnostic imaging , Contrast Media/administration & dosage , Heart Conduction System/physiopathology , Heart Rate , Magnetic Resonance Imaging , Meglumine/analogs & derivatives , Myocardial Infarction/complications , Myocardium/pathology , Organometallic Compounds/administration & dosage , Animals , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Disease Models, Animal , Electrophysiologic Techniques, Cardiac , Female , Male , Meglumine/administration & dosage , Myocardial Infarction/pathology , Myocardial Infarction/physiopathology , Predictive Value of Tests , Sus scrofa , Time Factors , Ventricular Function, Left , Ventricular Remodeling
18.
Circ Arrhythm Electrophysiol ; 12(4): e007090, 2019 04.
Article in English | MEDLINE | ID: mdl-30943762

ABSTRACT

BACKGROUND: High-current short-duration radiofrequency energy delivery has potential advantages for cardiac ablation. However, this strategy is limited by high current density and narrow safety-to-efficacy window. The objective of this study was to examine a novel strategy for radiofrequency energy delivery using a new electrode design capable of delivering high power at a low current density to increase the therapeutic range of radiofrequency ablation. METHODS: The Sphere9 is an expandable spheroid-shaped lattice electrode design with an effective surface area 10-fold larger than standard irrigated electrodes (lattice catheter). It incorporates 9 surface temperature sensors with ablation performed in a temperature-controlled mode. Phase I: in 6 thigh muscle preparations, 2 energy settings for atrial ablation were compared between the lattice and irrigated-tip catheters (low-energy: Tmax75°C/5 s versus 25 W/20 s; high-energy: Tmax75°C/7 s versus 30 W/20 s). Phase II: in 8 swine, right atrial lines were created in the posterior and lateral walls using low- and high-energy settings, respectively. Phase III: the safety, efficacy, and durability at 30 days were evaluated by electroanatomical mapping and histopathologic analysis. RESULTS: In the thigh model, the lattice catheter resulted in wider lesions at both low- and high-energy settings (18.7±3.3 versus 12.2±1.7 mm, P<0.0001; 19.4±2.4 versus 12.3±1.7 mm, P<0.0001). Atrial lines created with the lattice were wider (posterior: 14.7±3.4 versus 9.2±4.0 mm, P<0.0001; lateral: 15.8±4.2 versus 5.7±4.2 mm, P<0.0001) and required 85% shorter ablation time (12.4 versus 79.8 s/cm-line). While current squared (I2) was higher with Sphere9 (7.0±0.04 versus 0.2±0.002 A2; P<0.0001), the current density was lower (9.6±0.9 versus 16.9±0.09 mA/mm2; P<0.0001). At 30 days, 100% of ablation lines created with the lattice catheter remained contiguous compared with only 14.3% lines created with a standard irrigated catheter. This was achieved without steam pops or collateral tissue damage. CONCLUSIONS: In this preclinical model, a novel, high-current low-density radiofrequency ablation strategy created contiguous and durable ablation lines in significantly less ablation time and a comparable safety profile.


Subject(s)
Electrodes , Heart Atria/surgery , Radiofrequency Ablation/instrumentation , Animals , Equipment Design , Equipment Safety , Models, Animal , Prospective Studies , Swine , Thigh/surgery
19.
J Cardiovasc Electrophysiol ; 30(5): 749-757, 2019 05.
Article in English | MEDLINE | ID: mdl-30723994

ABSTRACT

INTRODUCTION: Multielectrode mapping catheters improve the ability to map within the heterogeneous scar. A novel Octaray catheter with eight spines and 48 electrodes may further improve the speed and resolution of atrial mapping. The aims of this study were to (1) establish the Octaray's baseline mapping performance and electrogram (EGM) characteristics in healthy atria and to (2) determine its utility for identifying gaps in a swine model of atrial ablation lines. METHODS AND RESULTS: The right atria of eight healthy swine were mapped with Octaray and Pentaray catheters (Biosense Webster, Irvine, CA) before and after the creation of ablation lines with intentional gaps. Baseline mapping characteristics including EGM amplitude, duration, number of EGMs, and mapping time were compared. Postablation maps were created and EGM characteristics of continuous lines and gaps were correlated with pathology. Compared with Pentaray, the Octaray collected more EGMs per map (2178 ± 637 vs 1046 ± 238; P < 0.001) at a shorter mapping duration (3.2 ± 0.79 vs 6.9 ± 2.67 minutes; P < 0.001). In healthy atria, the Octaray recorded lower bipolar voltage amplitude (1.96 ± 1.83 mV vs 2.41 ± 1.92 mV; P < 0.001) while ablation gaps were characterized by higher voltage amplitude (1.24 ± 1.12 mV vs 1.04 ± 1.27 mV; P < 0.001). Ablation gaps were similarly identified by both catheters (P = 1.0). The frequency of "false gaps," defined as intact ablation lines with increased voltage amplitude was more common with Pentaray (6 vs 2) and resulted from erroneous annotation of far-field EGMs. CONCLUSION: The Octaray increases the mapping speed and density compared with the Pentaray catheter. It is as sensitive for identifying ablation gaps and more specific for mapping intact ablation lines.


Subject(s)
Action Potentials , Cardiac Catheters , Catheter Ablation , Electrophysiologic Techniques, Cardiac/instrumentation , Heart Atria/surgery , Heart Rate , Microelectrodes , Animals , Equipment Design , Heart Atria/physiopathology , Predictive Value of Tests , Sus scrofa , Time Factors
20.
Sci Rep ; 9(1): 2746, 2019 02 26.
Article in English | MEDLINE | ID: mdl-30808906

ABSTRACT

We characterized the f-waves in atrial fibrillation (AF) in the surface ECG by quantifying the amplitude, irregularity, and dominant rate of the f-waves in leads II, aVL, and V1, and investigated whether those parameters of the f-waves could discriminate long-standing persistent AF (LPeAF) from non-LPeAF. A total of 224 AF patients were enrolled: 112 with PAF (87 males), 48 with PeAF (38 males), and 64 with LPeAF (47 males). The f-waves in surface ECG leads V1, aVL, and II, which reflect well electrical activity in the right atrium (RA), the left atrium (LA), and both atria, respectively, were analyzed. The f-waves for LPeAF had lower amplitudes in II and aVL, increased irregularity and a higher dominant rate in II and V1 compared to PAF and PeAF (all p < 0.02). In a multivariate analysis, a low amplitude in lead II (<34.6 uV) and high dominant rate in lead V1 (≧390/min) (p < 0.001) independently discriminated LPeAF from the other AF types. The f-waves combined with both a low amplitude in lead II and high dominant rate in lead V1 were significantly associated with LPeAF (OR 6.27, p < 0.001). Characteristics of the f-waves on the surface ECG could discriminate LPeAF from other types of AF.


Subject(s)
Atrial Fibrillation/physiopathology , Electrocardiography/methods , Heart Conduction System/physiopathology , Female , Heart Rate , Humans , Male , Middle Aged