Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Hepatol Commun ; 4(7): 983-997, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32626831

ABSTRACT

Despite effective hepatitis B virus (HBV)-DNA suppression, HBV RNA can circulate in patients receiving nucleoside/nucleotide analogues (NAs). Current assays quantify HBV DNA by either real-time polymerase chain reaction (PCR), which uses DNA polymerase, or transcription-mediated amplification, which uses reverse-transcriptase (RT) and RNA polymerase. We assessed the effect of RT capability on HBV-DNA quantification in samples from three cohorts, including patients with quantified HBV RNA. We compared the HBV-DNA levels by real-time PCR (cobas HBV, Roche 6800/8800; Xpert HBV, Cepheid), transcription-mediated amplification (Aptima HBV, Hologic), and real-time PCR with added RT capability (cobas HBV+RT). In the first cohort (n = 45) followed over 192 weeks of NA therapy, on-treatment HBV-DNA levels were higher with cobas HBV+RT than cobas HBV (mean difference: 0.14 log10 IU/mL). In a second cohort (n = 50) followed over 96 weeks of NA therapy, HBV-DNA viral load was significantly higher with the cobas HBV+RT and Aptima HBV compared with the cobas HBV test at all time points after initiation of NA therapy (mean difference: 0.65-1.16 log10 IU/mL). A clinically significant difference was not detected between the assays at baseline. In a third cohort (n = 53), after a median of 2.2 years of NA therapy, we detected HBV RNA (median 5.6 log10 copies/mL) in 23 patients (43.4%). Median HBV-DNA levels by Aptima HBV were 2.4 versus less than 1 log10 IU/mL in samples with HBV RNA and without HBV RNA, respectively (P = 0.0006). In treated patients with HBV RNA, Aptima HBV measured higher HBV-DNA levels than Xpert HBV and cobas HBV. Conclusion: Tests including an RT step may overestimate HBV DNA, particularly in samples with low viral loads as a result of NA therapy. This overestimation is likely due to amplification of HBV RNA and may have an impact on clinical decisions.

2.
Expert Rev Mol Diagn ; 19(10): 951-957, 2019 10.
Article in English | MEDLINE | ID: mdl-31526152

ABSTRACT

Background: Molecular diagnostic tests for HBV, HCV and HIV-1 and other pathogens are widely used for clinical management. Practical issues related to workflow and labor requirements need to be characterized to inform selection of the most appropriate system. Research design and methods: We compared the workflow of two high-throughput systems: cobas 6800 (Roche) and Panther (Hologic), using average mid-size laboratory test volumes for five different assays (HIV-1, HBV, HCV, HPV or TV, and CT/NG). Results: Set-up time, time to first results, time to last results, and total hands-on time for cobas 6800 was 0.40, 2.47, 7.12, and 0.98 hours, respectively; on the Panther system, these times were 0.75, 2.7, 9.1, and 1.48 hours. Fifty-seven samples had results available at the first time point on cobas 6800 compared to 5 samples on the Panther system. The Panther system required more manual steps including several with potential risks of contamination or error. The number of reagents items required was 5 for cobas 6800 and 40 for the Panther system. Conclusions: Both systems provided a high level of automation. The cobas 6800 platform had shorter start up, time to first result, time to last result and hands-on times than the Panther system.


Subject(s)
Molecular Diagnostic Techniques/methods , Virus Diseases/diagnosis , Viruses/genetics , Automation, Laboratory/methods , Humans , Pathology, Molecular , Reagent Kits, Diagnostic , Virus Diseases/virology , Workflow
3.
Expert Rev Mol Diagn ; 19(10): 941-949, 2019 10.
Article in English | MEDLINE | ID: mdl-31159598

ABSTRACT

Background: Viral load (VL) quantification is important for the management of HBV, HCV, and HIV-1-infected patients. Several semi- or fully automated systems and assays are available that can be used to measure VL for these and other targets. Research design and methods: We assessed the accuracy, genotype/subtype inclusivity, and precision of four VL assays for three viral targets: cobas 4800 (Roche), cobas 6800 (Roche), Aptima (Hologic) and VERIS (Beckman), using WHO standards, cell culture supernatants and clinical samples. Results: Most results were close to expected values, except for significant under-quantification of HIV-1 group O, HBV genotype C, and D at high VL, and HCV genotype 3 by Aptima, and of HIV-1 CRF01_AE and group N and HCV genotype 3 by VERIS. Precision was comparable between tests except for VERIS HCV, which showed more variability. Aptima and cobas 6800 results agreed well with each other except HBV VL at lower VL (<10,000 IU/mL) where Aptima results tended to be higher. Conclusions: Results from different VL assays may not always agree in certain subsets of patients. Clinicians should we aware of these findings when making treatment decisions.


Subject(s)
DNA, Viral/genetics , HIV-1/genetics , Hepacivirus/genetics , Hepatitis B virus/genetics , RNA, Viral/genetics , Viral Load/genetics , Automation, Laboratory/methods , Genotype , Humans , Molecular Diagnostic Techniques/methods , Reagent Kits, Diagnostic
SELECTION OF CITATIONS
SEARCH DETAIL
...