Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Language
Publication year range
1.
Clinics (Sao Paulo) ; 69(12): 804-8, 2014.
Article in English | MEDLINE | ID: mdl-25627991

ABSTRACT

OBJECTIVE: To analyze the clinical results of a partial vertebrectomy with titanium mesh implantation and pedicle screw fixation using a posterior approach to reconstruct the spine in the treatment of thoracolumbar burst fractures. METHOD: From January 2006 to August 2008, 20 patients with severe thoracolumbar fractures were treated.For vertebral bodies associated with one injured intervertebral disk, subtotal vertebrectomy surgery and single-segment fusion were performed. For vertebral bodies with two injured adjacent intervertebral disks, partial vertebrectomy surgery and two-segment fusion were performed. RESULTS: All 20 patients were followed up for 12 to 24 months (average of 18 months). There were no complications such as wound infections, hemopneumothorax or abdominal infections in any of the patients. The neurological status of all of the patients was improved by at least one American Spinal Injury Association grade by the last follow-up. The anterior vertebral body height was an average of 50.77% before surgery, 88.51% after surgery and 87.86% at the last follow up; the sagittal Cobb angle was improved, on average, from 26.15° to 5.39° and was 5.90° at the last follow up. The percentage of spinal stenosis was improved, on average, from 26.07% to 4.93%° and was 6.15% at the last follow up. There were significant differences in the anterior vertebral body height pre- and post-surgery and in the sagittal Cobb angle and the percentage of spinal stenosis (p<0) in all patients. CONCLUSIONS: This surgical procedure is simple and can accomplish decompression, reduction, fixation and fusion of the spine in one stage. This approach could be widely used in orthopedics.


Subject(s)
Fracture Fixation, Internal/methods , Lumbar Vertebrae/injuries , Pedicle Screws , Spinal Fractures/surgery , Surgical Mesh , Thoracic Vertebrae/injuries , Titanium/therapeutic use , Adult , Female , Follow-Up Studies , Humans , Lumbar Vertebrae/diagnostic imaging , Male , Middle Aged , Operative Time , Reproducibility of Results , Severity of Illness Index , Spinal Fractures/diagnostic imaging , Thoracic Vertebrae/diagnostic imaging , Time Factors , Tomography, X-Ray Computed , Treatment Outcome , Young Adult
2.
Clinics ; Clinics;69(12): 804-808, 2014. tab, graf
Article in English | LILACS | ID: lil-732394

ABSTRACT

OBJECTIVE: To analyze the clinical results of a partial vertebrectomy with titanium mesh implantation and pedicle screw fixation using a posterior approach to reconstruct the spine in the treatment of thoracolumbar burst fractures. METHOD: From January 2006 to August 2008, 20 patients with severe thoracolumbar fractures were treated.For vertebral bodies associated with one injured intervertebral disk, subtotal vertebrectomy surgery and single-segment fusion were performed. For vertebral bodies with two injured adjacent intervertebral disks, partial vertebrectomy surgery and two-segment fusion were performed. RESULTS: All 20 patients were followed up for 12 to 24 months (average of 18 months). There were no complications such as wound infections, hemopneumothorax or abdominal infections in any of the patients. The neurological status of all of the patients was improved by at least one American Spinal Injury Association grade by the last follow-up. The anterior vertebral body height was an average of 50.77% before surgery, 88.51% after surgery and 87.86% at the last follow up; the sagittal Cobb angle was improved, on average, from 26.15° to 5.39° and was 5.90° at the last follow up. The percentage of spinal stenosis was improved, on average, from 26.07% to 4.93%° and was 6.15% at the last follow up. There were significant differences ...


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Fracture Fixation, Internal/methods , Lumbar Vertebrae/injuries , Pedicle Screws , Surgical Mesh , Spinal Fractures/surgery , Thoracic Vertebrae/injuries , Titanium/therapeutic use , Follow-Up Studies , Lumbar Vertebrae , Operative Time , Reproducibility of Results , Severity of Illness Index , Spinal Fractures , Time Factors , Tomography, X-Ray Computed , Treatment Outcome , Thoracic Vertebrae
SELECTION OF CITATIONS
SEARCH DETAIL