Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
Add more filters










Publication year range
1.
Front Cardiovasc Med ; 11: 1306055, 2024.
Article in English | MEDLINE | ID: mdl-38689859

ABSTRACT

Introduction: Signal-averaged electrocardiography (SAECG) provides diagnostic and prognostic information regarding cardiac diseases. However, its value in other nonischemic cardiomyopathies (NICMs) remains unclear. This study aimed to investigate the role of SAECG in patients with NICM. Methods and results: This retrospective study included consecutive patients with NICM who underwent SAECG, biventricular substrate mapping, and ablation for ventricular arrhythmia (VA). Patients with baseline ventricular conduction disturbances were excluded. Patients who fulfilled at least one SAECG criterion were categorized into Group 1, and the other patients were categorized into Group 2. Baseline and ventricular substrate characteristics were compared between the two groups. The study included 58 patients (39 men, mean age 50.4 ± 15.5 years), with 34 and 24 patients in Groups 1 and 2, respectively. Epicardial mapping was performed in eight (23.5%) and six patients (25.0%) in Groups 1 and 2 (p = 0.897), respectively. Patients in Group 1 had a more extensive right ventricular (RV) low-voltage zone (LVZ) and scar area than those in Group 2. Group 1 had a larger epicardial LVZ than Group 2. Epicardial late potentials were more frequent in Group 1 than in Group 2. There were more arrhythmogenic foci within the RV outflow tract in Group 1 than in Group 2. There was no significant difference in long-term VA recurrence. Conclusion: In our NICM population, a positive SAECG was associated with a larger RV endocardial scar, epicardial scar/late potentials, and a higher incidence of arrhythmogenic foci in the RV outflow tract.

2.
Heliyon ; 10(7): e28111, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38596035

ABSTRACT

This study develops an efficient approach for precise channel frame detection in complex backgrounds, addressing the critical need for accurate drone navigation. Leveraging YOLACT and group regression, our method outperforms conventional techniques that rely solely on color information. We conducted extensive experiments involving channel frames placed at various angles and within intricate backgrounds, training the algorithm to effectively recognize them. The process involves initial edge image detection, noise reduction through binarization and erosion, segmentation of channel frame line segments using the Hough Transform algorithm, and subsequent classification via the K-means algorithm. Ultimately, we obtain the regression line segment through linear regression, enabling precise positioning by identifying intersection points. Experimental validations validate the robustness of our approach across diverse angles and challenging backgrounds, making significant advancements in UAV applications.

3.
Bioorg Chem ; 146: 107291, 2024 May.
Article in English | MEDLINE | ID: mdl-38521011

ABSTRACT

Hyaluronidase is a promising target in drug discovery, given its overexpression in a range of physiological and pathological processes, including tumor migration, skin aging, sagging, and wrinkling, as well as inflammation and bacterial infections. In this study, to identify novel hyaluronidase inhibitors, we applied click chemistry for the modular synthesis of 370 triazoles in 96-well plates, starting with biphenyl azide. Utilizing an optimized turbidimetric screening assay in microplates, we identified Fmoc-containing triazoles 5 and 6, as well as quinoline-containing triazoles 15 and 16, as highly effective hyaluronidase inhibitors. Subsequent research indicated that these triazoles potentially interact with a novel binding site of hyaluronidase. Notably, these inhibitors displayed minimal cytotoxicity and showed promising anti-inflammatory effects in LPS-stimulated macrophages. Remarkably, compound 6 significantly reduced NO release by 74 % at a concentration of 20 µM.


Subject(s)
Biphenyl Compounds , Hyaluronoglucosaminidase , Triazoles , Triazoles/chemistry , Click Chemistry , Binding Sites
4.
Circ J ; 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38355108

ABSTRACT

BACKGROUND: The aim of this study was to build an auto-segmented artificial intelligence model of the atria and epicardial adipose tissue (EAT) on computed tomography (CT) images, and examine the prognostic significance of auto-quantified left atrium (LA) and EAT volumes for AF.Methods and Results: This retrospective study included 334 patients with AF who were referred for catheter ablation (CA) between 2015 and 2017. Atria and EAT volumes were auto-quantified using a pre-trained 3-dimensional (3D) U-Net model from pre-ablation CT images. After adjusting for factors associated with AF, Cox regression analysis was used to examine predictors of AF recurrence. The mean (±SD) age of patients was 56±11 years; 251 (75%) were men, and 79 (24%) had non-paroxysmal AF. Over 2 years of follow-up, 139 (42%) patients experienced recurrence. Diabetes, non-paroxysmal AF, non-pulmonary vein triggers, mitral line ablation, and larger LA, right atrium, and EAT volume indices were linked to increased hazards of AF recurrence. After multivariate adjustment, non-paroxysmal AF (hazard ratio [HR] 0.6; 95% confidence interval [CI] 0.4-0.8; P=0.003) and larger LA-EAT volume index (HR 1.1; 95% CI 1.0-1.2; P=0.009) remained independent predictors of AF recurrence. CONCLUSIONS: LA-EAT volume measured using the auto-quantified 3D U-Net model is feasible for predicting AF recurrence after CA, regardless of AF type.

5.
Front Cardiovasc Med ; 11: 1305485, 2024.
Article in English | MEDLINE | ID: mdl-38292242

ABSTRACT

Introduction: Catheter ablation is an effective and safe strategy for treating atrial fibrillation patients. Nevertheless, studies on the long-term outcomes of catheter ablation in patients with dilated cardiomyopathy are limited. This study aimed to assess the electrophysiological characteristics of atrial fibrillation patients with dilated cardiomyopathy and compare the long-term clinical outcomes between patients undergoing catheter ablation and medical therapy. Method: Patient baseline characteristics and electrophysiological parameters were examined to identify the predictors of atrial fibrillation recurrence following catheter ablation. The clinical outcomes of catheter ablation and medical therapy were compared using the propensity score matched method. Results: A total of 343 patients were enrolled, with 46 in the catheter ablation group and 297 in the medical therapy group. Among the catheter ablation group, 58.7% (n = 27) had persistent atrial fibrillation. The recurrence rate of atrial arrhythmia was 30.4% (n = 14) after an average follow-up duration of 7.7 years following catheter ablation. The only predictive factor for atrial fibrillation recurrence after catheter ablation was the left atrial diameter. When compared to medical therapy, catheter ablation demonstrated significantly better outcomes in terms of overall survival, freedom from heart failure hospitalization, improvement in left ventricular ejection fraction, and a greater reduction in left ventricular diameter and left atrial diameter after propensity score matching. Conclusions: Therefore, catheter ablation proves to be effective in providing long-term control of atrial fibrillation in patients with dilated cardiomyopathy. In addition to standard heart failure care, catheter ablation significantly enhanced both morbidity and mortality outcomes and reversed structural remodeling when compared to heart failure medication alone.

6.
J Cardiol ; 83(5): 306-312, 2024 May.
Article in English | MEDLINE | ID: mdl-37838339

ABSTRACT

BACKGROUND: Modifying the autonomic system after catheter ablation may prevent the recurrence of atrial fibrillation (AF). Evaluation of skin sympathetic nerve activity (SKNA) is a noninvasive method for the assessment of sympathetic activity. However, there are few studies on the effects of different energy settings on SKNA. OBJECTIVE: To investigate the changes in SKNA in different energy settings and their relationship to AF ablation outcomes. METHODS: Seventy-two patients with paroxysmal and persistent AF were enrolled. Forty-three patients received AF ablation with the conventional (ConV) energy setting (low power for long duration), and 29 patients using a high-power, short-duration (HPSD) strategy. The SKNA was acquired from the right arm 1 day before and after the radiofrequency ablation. We analyzed the SKNA and ablation outcomes in the different energy settings. RESULTS: Both groups had a similar baseline average SKNA (aSKNA). We found that the median aSKNA increased significantly from 446.82 µV to 805.93 µV (p = 0.003) in the ConV group but not in the HPSD group. In the ConV group, patients without AF recurrence had higher aSKNA values. However, the 1-year AF recurrence rate remained similar between both groups (35 % vs. 28 %, p = 0.52). CONCLUSION: The post-ablation aSKNA levels increased significantly in the ConV group but did not change significantly in the HPSD group, which may reflect different neuromodulatory effects. However, the one-year AF recurrence rates were similar for both groups. These results demonstrate that the HPSD strategy has durable lesion creation but less lesion depth, which may reduce collateral damage.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Sympathetic Nervous System , Catheter Ablation/methods , Treatment Outcome , Pulmonary Veins/surgery , Recurrence
7.
Front Cardiovasc Med ; 10: 1265890, 2023.
Article in English | MEDLINE | ID: mdl-37953760

ABSTRACT

Background: Atrial fibrillation (AF) and mitral regurgitation (MR) have a complex interplay. Catheter ablation (CA) of AF may be a potential method to improve the severity of MR in AF patients. Methods: Patients with symptomatic AF and moderate to severe MR who underwent catheter ablation from 2011 to 2021 were retrospectively included in the study. Patients' baseline characteristics and electrophysiological features were examined. These patients were classified as group 1 with improved MR and group 2 with refractory MR after CA. Results: Fifty patients (age 60.2 ± 11.6 years, 29 males) were included in the study (32 in group 1 and 18 in group 2). Group 1 patients had a lower CHA2DS2-VASc score (1.7 ± 1.5 vs. 2.7 ± 1.5, P = 0.005) and had a lower incidence of hypertension (28.1% vs. 66.7%, P = 0.007) and diabetes mellitus (3.1% vs. 22.2%, P = 0.031) as compared to group 2 patients. Electroanatomic three-dimensional (3D) mapping showed that group 1 patients demonstrated less scars on the posterior bottom of the left atrium compared to group 2 patients (12.5% vs. 66.7%, P < 0.001). AF recurrence was not different between the two groups. After multivariate logistic regression analysis, a posterior bottom scar in the left atrium independently predicted refractory MR despite successful AF ablation. Conclusion: Most patients with AF and MR showed improvement of MR after AF ablation. A scar involving the posterior bottom of the left atrium is associated with poor recovery of MR.

8.
J Cardiovasc Electrophysiol ; 34(12): 2504-2513, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37822117

ABSTRACT

INTRODUCTION: Despite undergoing an index ablation, some patients progress from paroxysmal atrial fibrillation (PAF) to persistent AF (PersAF), and the mechanism behind this is unclear. The aim of this study was to investigate the predictors of progression to PersAF after catheter ablation in patients with PAF. METHODS: This study included 400 PAF patients who underwent an index ablation between 2015 and 2019. The patients were classified into three groups based on their outcomes: Group 1 (PAF to sinus rhythm, n = 226), Group 2 (PAF to PAF, n = 146), and Group 3 (PAF to PersAF, n = 28). Baseline and procedural characteristics were collected, and predictors for AF recurrence and progression were evaluated. RESULTS: The mean age of the patients was 58.4 ± 11.1 years, with 272 males. After 3 years of follow-up, 7% of the PAF cases recurred and progressed to PersAF despite undergoing an index catheter ablation. In the multivariable analysis, a larger left atrial (LA) diameter and the presence of non-pulmonary vein (PV) triggers during the index procedure independently predicted recurrence. Moreover, a larger LA diameter, the presence of non-PV triggers, and a history of thyroid disease independently predicted AF progression. CONCLUSION: The progression from PAF to PersAF after catheter ablation is associated with a larger LA diameter, history of thyroid disease, and the presence of non-PV triggers. Meticulous preprocedural evaluation, patient selection, and comprehensive provocation tests during catheter ablation are recommended.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Thyroid Diseases , Male , Humans , Middle Aged , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Treatment Outcome , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
9.
Circ J ; 87(12): 1750-1756, 2023 11 24.
Article in English | MEDLINE | ID: mdl-37866912

ABSTRACT

BACKGROUND: Circumferential pulmonary vein isolation (CPVI) has supplanted segmental PVI (SPVI) as standard procedure for atrial fibrillation (AF). However, there is limited evidence examining the efficacy of these strategies in redo ablations. In this study, we investigated the difference in recurrence rates between SPVI and CPVI in redo ablations for PV reconnection.Methods and Results: This study retrospectively enrolled 543 patients who had undergone AF ablation between 2015 and 2017. Among them, 167 patients (30.8%, including 128 male patients and 100 patients with paroxysmal AF) underwent redo ablation for recurrent AF. Excluding 26 patients without PV reconnection, 141 patients [90 patients of SPVI (Group 1) and 51 patients of CPVI (Group 2)] were included. The AF-free survival rates were 53.3% and 56.9% in Group 1 and Group 2, respectively (P=0.700). The atrial flutter (AFL)-free survival rates were 90% and 100% in Group 1 and Group 2, respectively (P=0.036). The ablation time was similar between groups, and there no major complications were observed. CONCLUSIONS: For redo AF ablation procedures, SPVI and CPVI showed similar outcomes, except for a higher AFL recurrence rate for SPVI after long-term follow-up (>2 years). This may be due to a higher probability of residual PV gaps causing reentrant AFL.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Retrospective Studies , Treatment Outcome , Recurrence , Catheter Ablation/adverse effects , Catheter Ablation/methods
10.
J Comput Aided Mol Des ; 37(7): 301-312, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37286854

ABSTRACT

Cell division control protein 42 homolog (Cdc42), which controls a variety of cellular functions including rearrangements of the cell cytoskeleton, cell differentiation and proliferation, is a potential cancer therapeutic target. As an endogenous negative regulator of Cdc42, the Rho GDP dissociation inhibitor 1 (RhoGDI1) can prevent the GDP/GTP exchange of Cdc42 to maintain Cdc42 into an inactive state. To investigate the inhibition mechanism of Cdc42 through RhoGDI1 at the atomic level, we performed molecular dynamics (MD) simulations. Without RhoGDI1, Cdc42 has more flexible conformations, especially in switch regions which are vital for binding GDP/GTP and regulators. In the presence of RhoGDI1, it not only can change the intramolecular interactions of Cdc42 but also can maintain the switch regions into a closed conformation through extensive interactions with Cdc42. These results which are consistent with findings of biochemical and mutational studies provide deep structural insights into the inhibition mechanisms of Cdc42 by RhoGDI1. These findings are beneficial for the development of novel therapies targeting Cdc42-related cancers.


Subject(s)
Molecular Dynamics Simulation , rho Guanine Nucleotide Dissociation Inhibitor alpha , cdc42 GTP-Binding Protein , Cell Differentiation , Guanosine Triphosphate
11.
Front Cardiovasc Med ; 10: 1135230, 2023.
Article in English | MEDLINE | ID: mdl-37252115

ABSTRACT

Background: Catheter ablation (CA) is a treatment strategy for atrial fibrillation (AF) in patients with hypertrophic cardiomyopathy (HCM). We investigated the electrophysiological characteristics of recurrence in a tertiary referral center and compared long-term clinical outcomes after CA therapy with patients who did not undergo CA. Methods: Patients with HCM and AF who underwent CA (group 1, n = 60) or pharmacological treatment (group 2, n = 298) between 2006 and 2021 were enrolled in this study. The baseline characteristics and electrophysiological characteristics of group 1 patients were examined to elucidate the reason for the recurrence of AF after CA therapy. The clinical results of the patients in Group 1 and Group 2 were compared using a propensity score (PS)-matched method. Results: The most common cause of recurrence was pulmonary vein reconnection (86.5%), followed by non-pulmonary vein triggers (40.5%), cavotricuspid isthmus flutter (29.7%), and atypical flutter (24.3%). Thyroid disease (HR, 14.713; P < 0.01), diabetes (HR, 3.074; P = 0.03), and non-paroxysmal AF (HR, 4.012; P = 0.01); these factors independently predicted recurrence. After the first recurrence, patients who underwent repeat CA showed a better arrhythmia-free state (74.1%) than those who underwent drug escalation therapy (29.4%, P < 0.01). After matching, PS-group 1 patients showed significantly better outcomes in all-cause mortality, heart failure hospitalization, and left atrial reverse remodeling than PS-group 2 patients. Conclusions: Patients who underwent CA showed better clinical outcomes than those who underwent drug therapy. The main predictors of recurrence were thyroid disease, diabetes, and non-paroxysmal AF.

12.
Bioorg Med Chem ; 90: 117337, 2023 07 15.
Article in English | MEDLINE | ID: mdl-37253305

ABSTRACT

Rho guanosine triphosphatases (Rho GTPases), as members of the Ras superfamily, are GDP/GTP binding proteins that behave as molecular switches for the transduction of signals from external stimuli. Rho GTPases play essential roles in a number of cellular processes including cell cycle, cell polarity as well as cell migration. The dysregulations of Rho GTPases are related with various diseases, especially with cancers. Accumulating evidence supports that Rho GTPases play important roles in cancer development and progression. Rho GTPases become potential therapeutic targets for cancer therapy. And a number of inhibitors targeting Rho GTPases have been developed. In this review, we discuss their structural features, summarize their roles in cancer, and focus on the recent progress of their inhibitors, which are beneficial for the drug discovery targeting Rho GTPases.


Subject(s)
Neoplasms , rho GTP-Binding Proteins , Humans , rho GTP-Binding Proteins/metabolism , rho GTP-Binding Proteins/therapeutic use , Neoplasms/drug therapy , Drug Discovery , Cell Cycle , Cell Movement
13.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37097046

ABSTRACT

AIMS: This study investigated the epidemiological characteristics of new-onset dementia in patients with atrial fibrillation (AF) and the association of catheter ablation with different subtypes of dementia. METHODS AND RESULTS: We conducted a population-based, retrospective cohort study using data from the Taiwan National Health Insurance Research Database. In total, 136 774 patients without a history of dementia were selected after 1:1 propensity score matching based on age (with AF vs. without AF). A competing risk model was used to investigate the three subtypes of dementia: Alzheimer's disease, vascular dementia, and other/mixed dementia. Inverse probability of treatment weighting (IPTW) was performed to minimize the impact on dementia risk due to the imbalanced baseline characteristics. After a median follow-up period of 6.6 years, 8704 events of new-onset dementia occurred. Among all AF patients developing dementia, 73% were classified as having Alzheimer's disease, 16% as having vascular dementia, and 11% as having other/mixed dementia. The cumulative incidence of dementia in AF patients was higher than those without AF (log-rank test: P < 0.001 for both before and after IPTW). In patients with AF undergoing catheter ablation, the total dementia risk decreased significantly [P = 0.015, hazard ratio (HR): 0.74, 95% confidence interval (CI): 0.58-0.94] after multivariable adjustment, but not for the subtype of vascular dementia (P = 0.59, HR: 0.86, 95% CI: 0.49-1.50). CONCLUSION: Patients with AF have a higher incidence of all types of dementia, including Alzheimer's disease, vascular dementia, and a mixed type of dementia. Alzheimer's disease is less likely to occur in patients with AF undergoing catheter ablation.


Subject(s)
Alzheimer Disease , Atrial Fibrillation , Catheter Ablation , Dementia, Vascular , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Alzheimer Disease/diagnosis , Alzheimer Disease/epidemiology , Alzheimer Disease/complications , Dementia, Vascular/complications , Dementia, Vascular/surgery , Retrospective Studies , Risk Reduction Behavior , Catheter Ablation/adverse effects , Risk Factors , Treatment Outcome , Follow-Up Studies , Recurrence
14.
15.
Acta Biomater ; 161: 226-237, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36898473

ABSTRACT

Cation-associated cytotoxicity limits the systemic administration of RNA delivery in vivo, demanding the development of non-cationic nanosystems. In this study, cation-free polymer-siRNA nanocapsules with disulfide-crosslinked interlayer, namely T-SS(-), were prepared via the following steps: 1) complexation of siRNA with a cationic block polymer cRGD-poly(ethylene glycol)-b-poly[(2-aminoethanethiol)aspartamide]-b-poly{N'-[N-(2-aminoethyl)-2-ethylimino-1-aminomethyl]aspartamide}, abbreviated as cRGD-PEG-PAsp(MEA)-PAsp(C=N-DETA), 2) interlayer crosslinking via disulfide bond in pH 7.4 solution, and 3) removal of cationic DETA pendant at pH 5.0 via breakage of imide bond. The cationic-free nanocapsules with siRNA cores not only showed great performance (such as efficient siRNA encapsulation, high stability in serum, cancer cell targeting via cRGD modification, and GSH-triggered siRNA release), but also achieved tumor-targeted gene silencing in vivo. Moreover, the nanocapsules loaded with siRNA against polo-like kinase 1 (siRNA-PLK1) significantly inhibited tumor growth without showing cation-associated toxicity side effects and remarkably improved the survival rate of PC-3 tumor-bearing mice. The cation-free nanocapsules could potentially serve as a safe and effective platform for siRNA delivery. STATEMENT OF SIGNIFICANCE: Cation-associated toxicity limits the clinical translation of cationic carriers for siRNA delivery. Recently, several non-cationic carriers, such as siRNA micelles, DNA-based nanogels, and bottlebrush-architectured poly(ethylene glycol), have been developed to deliver siRNA. However, in these designs, siRNA as a hydrophilic macromolecule was attached to the nanoparticle surface instead of being encapsulated. Thus, it was easily degraded by serum nuclease and often induced immunogenicity. Herein, we demonstrate a new type of cation-free siRNA-cored polymeric nanocapsules. The developed nanocapsules not only showed capacities including efficient siRNA encapsulation, high stability in serum, and cancer cell targeting via cRGD modification, but also achieved an efficient tumor-targeted gene silencing in vivo. Importantly, unlike cationic carriers, the nanocapsules exhibited no cation-associated side effects.


Subject(s)
Nanocapsules , Animals , Mice , RNA, Small Interfering/chemistry , Nanocapsules/chemistry , RNAi Therapeutics , DEET , Cell Line, Tumor , Polymers/chemistry , Polyethylene Glycols/chemistry
16.
Vaccines (Basel) ; 10(8)2022 Aug 10.
Article in English | MEDLINE | ID: mdl-36016174

ABSTRACT

The association of SARS-CoV-2 messenger ribonucleic acid vaccines with pericarditis in young adults has been reported. However, data regarding other types of vaccines are extremely limited. We presented a 94-year-old man with rapidly progressive dyspnea and fatigue six days after his first ChAdOx1 nCoV-19 vaccination. Impending cardiac tamponade and bilateral pleural effusion were found. Hence, massive yellowish pericardial and pleural effusion were drained. However, the pleural effusion persisted and pigtail catheters were inserted bilaterally. After serial studies including surgical pleural biopsy, acute polyserositis (pericarditis and pleurisy) was diagnosed. Anti-inflammatory treatment with colchicine and prednisolone was administered. All effusions resolved accordingly. This rare case sheds light on the presentation of ChAdOx1 nCoV-19 vaccine-related acute polyserositis. In conclusion, awareness of this potential adverse event may facilitate the diagnosis for unexplained pericardial or pleural effusion after vaccination.

17.
J Clin Med ; 11(11)2022 Jun 04.
Article in English | MEDLINE | ID: mdl-35683600

ABSTRACT

Identification of sinus node dysfunction (SND) before termination of persistent AFL by catheter ablation (CA) is challenging. This study aimed to investigate the characteristics and predictors of acute and delayed SND after AFL ablation. We retrospectively enrolled 221 patients undergoing CA of persistent AFL in a tertiary referral center. Patients with SND who required a temporary pacemaker (TPM) after termination of AFL or a permanent pacemaker (PPM) during follow-up were identified. Acute SND requiring a TPM was found in 14 of 221 (6.3%) patients following successful termination of AFL. A total of 10 of the 14 patients (71.4%) recovered from acute SND. An additional 11 (5%) patients presenting with delayed SND required a PPM during follow-up, including 4 patients recovering from acute SND. Of these, 9 of these 11 patients (81.8%) underwent PPM implantation within 1 year after the ablation. In multivariable analysis, female gender and a history of hypothyroidism were associated with the requirement for a TPM following termination of persistent AFL, while older age and a history of hypothyroidism predicted PPM implantation. This study concluded that the majority of patients with acute SND still require a PPM implantation despite the initial improvement. Therefore, it is reasonable to monitor the patients closely for at least one year after AFL ablation.

18.
Front Cardiovasc Med ; 8: 676897, 2021.
Article in English | MEDLINE | ID: mdl-34336945

ABSTRACT

Background: The clinical significance and outcomes of ventricular tachyarrhythmias (VTa) in patients undergoing valve replacement have rarely been reported. Objective: This study aimed to investigate the incidence and outcome of VTa after surgical valve replacement. Methods: We conducted a population-based retrospective cohort study using data obtained from the Taiwan National Health Insurance Research Database. In total, 10,212 patients were selected after 1:1 propensity-score matching based on the type of prosthetic valve used (mechanical vs. bioprosthetic). Various outcomes during long-term follow-up were analyzed. Results: After a median follow-up period of 59.6 months, the crude incidence rate of VTa after surgical valve replacement was 4.8/1,000 person-years, and the cumulative incidence of VTa persistently increased after surgery. Furthermore, the occurrences of VTa after valve replacement significantly increased the risk of cardiovascular (CV) death (P < 0.001, HR 1.67, 95% CI 1.41-1.96), stroke- (P < 0.001, HR 1.66, 95% CI 1.37-2.01), atrial fibrillation- (P < 0.001, HR 2.80, 95% CI 2.42-3.24), and congestive heart failure-related hospitalization (P < 0.001, HR 2.61, 95% CI 2.30-2.95). Among patients with VTa, all-cause mortality (P = 0.001, HR 0.49, 95% CI 0.32-0.75) and CV death (P = 0.047, HR 0.58, 95% CI 0.34-0.99) in those with implantable cardioverter-defibrillator (ICD) implantation were lower than those without. Conclusion: The crude incidence rate of VTa after surgical valve replacement was 4.8/1,000 person-years, and the cumulative incidence of VTa persistently increased during follow-up. The presence of VTa after surgical valve replacement increases hospitalization and CV death, while ICD implantation reduced the mortality rate in these patients.

19.
Front Cardiovasc Med ; 8: 745370, 2021.
Article in English | MEDLINE | ID: mdl-34977171

ABSTRACT

Background: Valve replacement is associated with worse outcomes in individuals who have end-stage renal disease (ESRD) and require a long-term renal replacement therapy. Prosthetic valve selection in patients with ESRD has remained controversial. Objective: We aimed to investigate long-term outcomes of mechanical and bioprosthetic valve replacement in individuals with ESRD. Methods: We conducted a population-based retrospective cohort study using data obtained from the Taiwan National Health Insurance Research Database. In total, 10,202 patients, including 912 ESRD and 9,290 non-ESRD patients, were selected after a 1:1 propensity-score matching based on the type of prosthetic valve used. The long-term mortality outcomes were then analyzed. Results: During a median follow-up period of 59.6 months, the Kaplan-Meier survival analysis revealed that ESRD patients who underwent mechanical valve replacement had higher rates of all-cause mortality and CV deaths than those who underwent bioprosthetic valve replacement (Log-rank test, p = 0.03 and 0.02, respectively). Multivariable regression analyses demonstrated that ESRD patients who underwent bioprosthetic valve replacement had lower rates of all-cause mortality (p < 0.001, hazard ratio: 0.88, 95% confidence interval: 0.82-0.93) and cardiovascular (CV) death (p < 0.001, hazard ratio: 0.83, 95% confidence interval: 0.76-0.90) than those who had mechanical valve replacement. Conclusion: Bioprosthetic valve replacement is significantly associated with lower rates of all-cause mortality and CV death in the ESRD population.

20.
J Sep Sci ; 31(10): 1819-27, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18481324

ABSTRACT

A novel single-step sol-gel approach for the preparation of beta-CD-bonded silica monolithic electrochromatographic columns is established. The porous silica networks were fabricated inside fused-silica capillaries using sol-gel processing of tetramethoxysilane and an organfunctional silicon alkoxide that contains beta-CD. Scanning electron micrographs and nitrogen adsorption-desorption data showed that these functional monolithic columns have double pores structures with micrometer-size co-continuous through-pores and silica skeletons with open mesopores. The beta-CD monolithic columns have successfully been applied to the separation of several neutral and negatively charged isomers by CEC. The column performance was evaluated by using positional isomers of naphthalenedisulfonic acid as model compounds. A plate height of less than 10 mum for the first eluted isomer of naphthalenedisulfonic acid was obtained at an optimal flow rate (0.47 mm/s) of the mobile phase. Moreover, the columns have been proved to be stable for more than 100 runs during 3 months period and show reasonable column reproducibility.

SELECTION OF CITATIONS
SEARCH DETAIL
...